Tender For Repair Maintenance Of Summer Cooling Appliances Ac Refrigerator And Water Coolers Of Various Sizes In Zone A Under Ge Af Tech Area Agra At Af Stn Agra, agra-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance Of Summer Cooling Appliances Ac Refrigerator And Water Coolers Of Various Sizes In Zone A Under Ge Af Tech Area Agra At Af Stn Agra. Submission Date for this Tender is 29-02-2024. Air Conditioner Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41963830
Corrigendum : Tender For Repair Maintenance Of Summer Cooling Appliances Ac Refrigerator And Water Coolers Of Various Sizes In Zone A Under Ge Af Tech Area Agra At Af Stn Agra
Open Tender
Indian
Uttar Pradesh
agra
29-02-2024

Tender Details

Tender For Repair Maintenance Of Summer Cooling Appliances Ac Refrigerator And Water Coolers Of Various Sizes In Zone A Under Ge Af Tech Area Agra At Af Stn Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 46000.0 /-
Tender Value
INR 23 Lakhs /-

BOQ Items

NAME OF WORK :REPAIR /MAINT OF SUMMER / COOLING APPLIANCES AC, REFRIGERATOR AND WATER COOLERS OF VARIOUS SIZES IN ZONE ‘A’UNDERGE (AF) TECH AREA AGRA AT AF STN AGRA
Sl. No. Item Description
1M&L for servicing of both (indoor & outdoor) unit of split type ACs of capacity 1.5/ 2.0TR by cleaning filters, removing internal dust by using vaccum cleaner and air blower, oiling & greasing wherever required and checking for proper cooling etc complete all as specified and directed. Note:- Th quoted rate shall be deemed to be inclusive of following:- (i) All tools and machinary required (ii) Servicing kit for indoor and outdoor unit with air compressor (iii)Servicing pump for removal of any foreign material from indoor/outdoor unit all as specified and directed by Engr-in-charge.
2M&L for taking down window type AC 1.5 TR & 2 TR capacity for servicing,cleaning the inner side of air conditioners with the help of air blower, taking out the blower motor and re-fitting the same after washing with kerosene oil and oiling, repair of the unserviceable bushes, including cleaning the condenser thoroughly with water and MAIC-DS solution with the help of wire brush by cleaningrepair of the air filter including cleaning testing after complete servicing to the entire satisfaction of Engineer-in-Charge and refixing in same position etc complete all as specified and directed.
3M&L for writing of SM/MES No etc as persample given by Engr-in-Charge on window AC with the help of stencil with synthetic enamel paint complete all as specified and directed.
4M&L for writing of SM/MES No etc as per sample given by Engr-in-Charge on Split AC with the help of stencil with synthetic enamel paint complete all as specified and directed.
5M&L for carryout day to day repair/rectification of AC & refrigeration complaints such as repair, rectify and replacement of unservicable parts of AC & refrigeration in air force station Agra area all as directed by Engr in Charge. Note:- (a) Fixing cost for ser Item No-06 to item No-25 listed below shall be deemed to included in quoted rates in this item. (b) 01 x ref mech and 01 x helper will be detailed by the contractor for attendingabove complaints on daily basis. Cost of which shall be deemed to be included in quoted rates. (c) Replacement of major items shall be measured and paid under relevant items of this schedule. (c) Ref mech and helper so detailed by the contractor will report to MES complaint cell at 0845 hrs morning to receive complaint slip from department and complaints shall be rectified within 08 Hours. If contractor fails to detail above tradesmen a panel recovery @ Rs. 500.00 per day shall be made to contractor and shall be recovered from RAR/Final bill.(d) Repairing upto 06 Complaints at different locations within AF stn location with minor fittings/ fixtures materials will be considered as one job.
6Supply only starting capacitor of 2.25/3.15 mfd suitable for blower motor of split type ACs of capacity 1.5/ 2.0TR etc complete all as specified and directed. Make:-Texla/ Asian/ Keltron/ Unistar/ Sarada/ Syscap as approved by GE.
7Supply only over load protector suitable for window type ACs of capacity 1.5/ 2.0TR including connections complete all as specified and directed. Make:- Renutrol/ Shri Ram/ Denfoss/ LG as approved by GE.
8Supply only selector/ rotary switch with knob 30 Amps, 250 volts etc complete all as specified and directed. Make:AGI model 254 B or equivalent model of other make as approved by GE.
9Supply only starting capacitor 100-120mfd, 275 volts suitable for ACs of capacity 1.5/ 2.0TR and making connections with & including PVC insulated copper wire and thimbles etc complete all as specified and directed. Make:-Texla/ Asian/ Keltron/ Unistar/ Sarada/ Syscap as approved by GE.
10Supply only running capacitor of capacity 50+6mfd, 230 volts suitable for ACs and making connections with & including PVC insulated copper wire and thimbles complete all as specified and directed. Make:-Texla/ Asian/ Keltron/ Unistar/ Sarada/ Syscap as approved by GE.
11Supply only starting relays suitable for compressors of window type ACs of capacity 1.5/ 2.0TRincluding connections complete all as specified and directed. Make:- Kirloskar/Renulator/ Denfoss as approved by GE.
12Supply only rewiring (wiring kit) of window type air conditioners of capacity 1.5/ 2.0TR with using best quality PVC insulated copper conductor cable including thimbles sleaves of suitable size & shape complete all as specified and directed. Make of wire:-Plaza/ Havells/ Paragon/ Finolex as approved by GE.
13Supply only thermostat switch suitable for window type ACs of capacity 1.5/ 2.0TR including necessary connection with and includingsuitable size of PVC copper conductor cable and thimbles sleeves of suitable shape & size complete all as specified and directed. Make:- Renutrol/ Indofoss/ Denfoss/ LG as approved by GE.
14Supply only prescribed control board panel (PCB)of existing make/ model suitable for window ACs of capacity 1.5/2.0TR complete all as specified and directed. Make:- Blue Star/ Voltas/ Carrier as approved by GE.
15Supply only prescribed control board panel (PCB)of existing make/ model suitable for split type ACs of capacity 1.5/2.0TR complete all as specified and directed. Make:- Blue Star/ Voltas/ Carrier as approved by GE.
16Supply only battery operated cordless remote control of existing make/ model suitable for split type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
17Supply only swing motor with flapper suitable for split type ACs of existing make/model capacity 1.5/ 2.0TR complete all as specified and directed. Make:- Blue Star/ Voltas/ Carrier/ Hitachi as approved by GE.
18Supply only blower motor of indoor unit suitable for split type ACs of capacity 1.5TR complete all as specified and directed. Make:- Blue Star/ Voltas/ Carrier/ Hitachi as approved by GE.
19Supply only AC electric blower motor of 1/7 HP to 1/5 HP, 230 volts, 930 RPM, 3 speed suitable for split type ACs of capacity 1.5/2.0 TR complete all as specified and directed. Make:- AUE/ GEC/ Blue Star/ Voltas/Carrier/ Usha/ Khaitan as approved by GE.
20Supply only AC electric blower motor of double shaft type of 1/7 HP to 1/5 HP, 230 volts 930 RPM, 3 speed suitable for window/ split type ACs of capacity 1.5 TR/ 2.0TR complete all as specified and directed. Make:- AUE/ GEC/ Blue Star/ Voltas/ Carrier/ Usha/ Khaitan as approved by GE.
21Supply only condenser fan motor suitable for outside condensing unit of split type ACs of capacity 1.5/ 2.0TR having minimum air displacement 400 cft per minutecomplete all as specified and directed. Make of motor:- American/ Universal/ Khaitan/ Usha as approved by GE.
22Supply only Blower/ Condenser fan blade (PVC) assembly of existing make & size suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
23Supply only PVC front grills ofexisting make, shape & size suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
24Supply only air sweep louvers with motor complete set suitable for window type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
25Supply only starting capacitor of 4.0/6.0 mfd suitable for blower motor of split type ACs of capacity 1.5/ 2.0TR complete all as specified and directed. Make:-Texla/ Asian/ Keltron/ Unistar/ Sarada/ Syscap as approved by GE. Note :- (i) The contractor will ensure that the unserviceable ACs are rectified within 24 hours of receiving of complaints. (ii) If contractor fails to make ACs serviceable within stipulated time then panelrecovery of 500/- per day for each complaint will be made from contrator dues.
26Supply and fix in repair, 1/4” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
27Supply and fix in repair, 5/8” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
28Supply and fix in repair, 1/2” dia copper tube suitable for split ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
29Supply & fix in repair of 20mm dia transparent PVC heavy duty flexible pipe ISI marked with and including necessary clamps & nails for fixing the drain pipe for drainage of swetting water of indoor unit of split type ACs complete all as specified and directed.
30Disconnecting, dismantling and taking out existing defective/ unserviceable fins and tube type cooling coil of any description & in any position and supply & fix new cooling coil 2 Row x 1/2,,5/8dia copper tube and aluminum fins suitable for split type ACs of capacity 1.5/2.0 TR complete all as specified and directed. Make:- Blue Star/ Voltas/ Carrier as approved by GE. Note:- Charging of refrigerant gas R-22/ M-22 shall be measured and paid separately under respective item of BOQ/ Sch`A" as "material and labour" complete.
31Supply and fixing in repair of sealed reciprocating type compressor for 1.5 TR of existing size and make and capacity at site including necessary brazing, soldering, pressure testing, R-22 refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed. Make : Kirloskar/ GEE/ TECUMSEH / HITACHI/ LG/ VOLTAS/ CARRIERas approved by GE.
32Supply and fixing in repair of sealed reciprocating type compressor for 2.0 TR of existing size and makeand capacity at siteincluding necessary brazing, soldering, pressure testing, R-22 refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed. Make : Kirloskar/ GEE/ TECUMSEH / HITACHI/ LG/ VOLTAS/ CARRIERas approved by GE.
33Supply and fixing in repair of sealed rotary type compressorsuitable for ACs of 1.5TR of existing size and makeand capacity at site including necessary brazing, soldering, pressure testing, R-22 refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed. Make : Kirloskar/ GEE/ TECUMSEH / HITACHI/ LG/ VOLTAS/ CARRIERas approved by GE.
34Supply and fixing in repair of sealed rotary type compressorsuitable for ACs of 2.0TR of existing size and makeand capacity at site including necessary brazing, soldering, pressure testing, R-22 refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed. Make : Kirloskar/ GEE/ TECUMSEH / HITACHI/ LG/ VOLTAS/ CARRIERas approved by GE.
35Supply and fixing in repair of sealed rotary type 3 phase compressor suitable for tower ACs of 4.0TR of existing size and makeand capacity at site including necessary brazing, soldering, pressure testing, R-22 refrigerant gas charging in appropriate quantity and leakage testing on completion complete all as specified and directed. Make : Kirloskar/ GEE/ TECUMSEH / HITACHI/ LG/ VOLTAS/ CARRIERas approved by GE.
36S&F in repair voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v to 250V with output voltage stablized at 230 V with accuracy of plusminus 2.5% and cap of5.0 KVA.complete all as specified and directed. Make : V Guard / Microtex/ Voltas / Everest or as approved by GE.
37S&F in repairvoltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v to 250V with output voltage stablized at 230 V with accuracy of plusminus 2.5% and cap of4.0 KVA complete all as specified and directed. Make : V Guard / Microtex/ Voltas / Everest or as approved by GE.
38Supply and fix in repair, PVC sheathed, 3 core copper conductor flexible cable of size 2.5sqmm with thimbles of suitable size & shape complete all as specified and directed. Make:- PLAZA/ FINOLEX/ HAVELLS/ NATIONAL/SHALABH as approved by GE.
39Supply and fix in repair, socket outlet 2 in 1, 3 pin 5 Amps and 3 pin 15 Amps, flush universal type complete all as specified & directed. Make:- Anchor/ Key/ Cona as approved by GE.
40.S&F in repairAC box modular typewith 25 Amps socket plug top and MCB single pole with a two pin and earth plug and socket complete25 Amp MCB ,240 volts making good disturbed surfaces to match with existing surfaces etc complete all as directed. Make Havells model No DBOXx MCBProtected/legrand/ Indo Asian
41Supply and fix in repair, sheet metal enclosure (AC box) including a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 Volts complete all as specified & directed. Make:- legrand /L & T /havells
42Supply and fix in repair, compressors of refrigerators of following models including cutting the suction and discharge line for removing of un-serviceable compressors and fixing of new compressors by jointing suction & discharge line, welding,brazing/ soldering, vaccumising and charging of gas with required quantity of R-134(a) gas to achieve the efficient cooling & smooth functioning and testing on completion complete all as specified and directed:- Note:- Gas charging of refrigerators shall be measured and paid separately under respective items of BOQ/ Sch"A" as "material and labour" complete.
43Supply and fix in repair refrigerators compressor of make Kirloskar for single door refrigerator of 100 to 180 Ltrs capacity complete all as specified and directed.
44Supply and fix in repair refrigerators compressor of make Kirloskar for single door refrigerator of 240 & 310 Ltrs capacity complete all as specified and directed.
45Supply and fix in repair refrigerators compressor of make Kirloskar for double door refrigerator of 310 & 330 Ltrs capacity complete all as specified and directed.
46Supply and fix in repair refrigerators compressor of make Kirloskar for double door refrigerator of 400 & 420 Ltrs capacity complete all as specified and directed.
47Supply and fix in repair, thermostat switch suitable for refrigerators of any capacity complete all as specified and directed. Make:- Renutral/ Indofoss/ Denfoss/ LG as approved by GE.
48Supply and fix in repair, condenser unit of existing make suitable for refrigerator of capacity 100 to 320 Ltrs including jointing of tubes and testing complete all as specified and directed. Make:- LG/ Kelvinator/ Whirlpool/ Cool point/ Godrej as approved by GE. Note:- Charging of refrigerant gas shall be measured and paid separately under respective item of BOQ/ Sch"A" as "material and labour" complete.
49M&L for gas charging with required quantity of refrigerant gas R-134/R-410 in refrigerators/ deep freezers of any capacity and make as directed by AGE for smooth functioning of refrigerators/ deep freezers after carryout vaccum and pressure test and including necessary sealing/ brazing to prevent the leakage, if any, complete all as specified and directed.
50M&L for gas charging with required quantity of refrigerant gas R-22/R-407 in window/ split type ACs of any capacity and model as directed by AGE for smooth functioning of ACs including necessary sealing/ brazing to prevent of leakage, if any, complete all as specified and directed.
51M&L for 3.0mm thick water proof plywood in repair including cutting to shape as required, fixed with screws to timber frame work/ walls etc and making good the disturbed surfaces as per existing complete all as specified and directed.
52Taking down existing window type ACs of 1.5/ 2.0TR capacity after disconnecting all electric connections and re-installation of the same at new location of work site after making the hole/ space in the wall including all other necessary materials as required to accommodate the AC and making good wall surfaces & hole as per existing and making all necessary electric connection and testing on completion complete all as specified and directed.
53Taking down & shifting of existing split type air conditioner of capacity 1.5/2.0TR to new location as direted including re-installation/ re-fixing the same at new location i.e outdoor and indoor units at new locations and making all necessary electric/ charging pipe line connections, commissioning and testing on completion and making good the disturbed surfaces of wall/ floor as per existing including comprising of the following accessories/ works complete all as specified and directed:- Note:- Contractor shall deposit the old/ existing bracket to MES store yard. (a) Fixing only cooling unit (indoor) with and including grouting nuts & bolts of required size and shape on wall complete all as specified and directed. (b) Fixing only condensing unit (outdoor) on wall with and including mild steel brackets & fasteners of required size and shape and provn of 100mm thick PCC platform of approx size 1.20x0.75M in PCC 1:2:4 type B1 using 20mm graded stone aggregate with and including grouting nuts & bolts of required size and shape on platform complete all as specified and directed. (c) Making holes/ cutting of grooves of suitable size & shape on wall/ floor and making good the same as per existing complete for fixing the gas and drainage pipes complete all as specified and directed. (d) Fixing only of copper pipes as obtained from taking down/ shifting of AC (Approx length 5.0M) including necessary cuttings & bent to shapes as required from indoor unit to outdoor unit including brazing the copper pipes complete all as specified and directed. (e) Fixing of 20mm dia transparent PVC heavy duty flexible pipe (Approx length 2.0M) for drainage complete all as specified and directed. (f) M&L for insulation of copper pipes with insulating materials including covering the same with and including PVC casing and caping of size 75x75mm for mechanical protection of copper pipes complete all as specified and directed (Approx length 5.0M). (g) Charging with required quantity of refrigerant gas R-22/M-22 as directed by AGE for smooth functioning of ACs after carryout vaccum and pressure test including necessary sealing/ brazing to prevent of leakage, if any, complete all as specified and directed. Note:- Refrigeant gas R-22/ M-22 quantity to be measured and paid for separately under appropriate item of sch "A"
54Supply and fix in repair, reverse valve (heating/ cooling) of existing make suitable for window/ split type ACs of capacity 1.5/ 2.0TR complete all as specified and directed.
55M&L for insulation of copper pipes (refrigerant gas pipes) with insulating materials of approved quality for better cooling effects of split type ACs or heat resistance/ protection of copper pipes from atmosphere including sealing/ covering the same with packing tape complete all as specified and directed. Note:- Length of copper pipes for insulation purpose shall be more than 4.5M and less than 6.0M for each job.
56Supply & fix in repair of new compressor for water coolersuitable for 40/80 Ltrs capacity water cooler of any make and model complete all as specified and directed.Make:- kirloskar model KCE-444 HAG/ Tecumseh AE Model No 4440G.
57Supply & fix in repair of new compressor for water coolersuitable for 60/120 Ltrs capacity water coolers compete all as specified and directed.Make:- Kirloskar model KCJ 461/467.
58Supply & fix in repair of new compressor for water coolersuitable for 120/150/150 Ltrs capacity water coolers compete all as specified and directed. Make:- Tecumseh No AW-1000/AHR-13/ Kirloskar model KCJ 513 HAE-B-420/ 422 or KCJ 511 HAE B-420/ 440.
59Supply & fix in repair of unserviceable PVC connection 15mm bore of 450 mm long with brass coupling with washers at both ends and connection to water cooler and water main complete all as specified and directed.
60Supply & fix in repair of unserviceable 15mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe or brass ferrule complete all as specified & directed. (Note-Min weight should not be less than 142 gms)Make:-Prayag /Jyoti
61Supply & fix in repair of unserviceable 15mm dia push button tap, cast copper alloy, screwed down for iron pipe or brass ferrule complete all as specified & directed.
62Supply & fix in repair of unserviceable aluminium blade for condensing fan motor of water coolers of any model/ size as per existing complete all as specified and directed.
63Supply & fix in repair of unserviceable plug top 3 pin 15 Amps complete all as specified and directed.
64Disconnecting and taking out the defective/ non-functional desert cooler of any description and in any position/ installed at any floor (where any ladders and other T&P are not suppose to use to remove the desert cooler from the position), strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable/ defective parts and including replacement of unserviceable spares/ parts i.e condenser, internal wiring, re-assembling & testing of the desert cooler complete all as specified and directed. Note:- Replacement/repair of defective/ wornout spares/ parts of desert cooler i.e condenser & internal wiring shall be measured and paid separately under respective items as ""S&Fin repair"
65M&L for painting after scraping/cleaning surfaces of desert cooler off sizes, applying one coat of black bituminous paint internally and one coat of synthetic enamel paint of approved colour on external surface of desert cooler of any make /type and capacity including writing of SM/ MES No and unit name complete all as specified and directed.
66S&F wood wool pads (set of three) in repair includingPVCpipe pieces 03 Nos of required length & dia for connection of water distribution PVC elbo 03 Nos of desert coolers of (Approx) complete all as specified and directed.
67S&Fsubmersible pump for desert coolerheavy duty, single phase including commissioning and testingcomplete all as specified and directed. Make:- Everest/ Shakti/ Crompton Greaves
68M&L for rewinding of existing burnt/ unserviceable exhaust fan motor of desert coolers of any description & in any position of capacity 450mm sweep, 900 RPM, opening of strip and rewinding with & including appropriate size copper super enameled wire of make Atlas/ Finolex / Devi Dayal as approved by the engineer-in-charge including insulating material such as illuminous paper, leatherized paper, cotton tape, glass sleeving, insulating varnish etc complete to the entire satisfaction of Engineer-in-charge including transportation from site to workshop & back to siteafter repair including necessary connections & testing on completion complete all as specified and directed.
69S&F of exhaust fan motor of desert coolers ,copper winding heavy duty,380mm sweep, 1400 RPM with all accessories complete all as specified and directed. Make:- Everest/ Khaitan/ GEC/ Crompton Greaves
70M&L for removing of perished body of desert cooler over all size 0.750x0.750x0.910 mtr from existing site andreplace the same with new body made out of 22 gauge PGI sheet by means of fabrication welding/ jointing having tank size Approximet 0.750x0.750x0.230mtr and front grillmade out of 26 gauge PGI sheet 0.460x 0.460mtr size for air flow direction,03 Nos perforated sheet side panels size Approximet 0.680x0.610mtr of each and also having electric control panel consisting two nos 5amp switch piano type single pole one way and one rotary speed regulator switch complete and duly painted with two coats of synthetic enamel paint over one coat of primer internally and externally complete all as specified and directed.
71"S&F""of detachable type perforated side panel in repair made out 26 gauge PGI sheet including wood pads of desert coolers of size 90cmX90cmX75cm complete all as specified and directed.
72S&F of front grills desert coolers in repair, size 18"x18" of each made out of 26 gauge sheet as per sample and including piano type switch complete all as specified and directed.
73S&F of front grills of desert coolers in repair, size 24"x24" each made out of 26 gauge sheet as per sample and including piano type switch complete all as specified and directed.
74M&L for rewinding of burnt ceiling fan 1200/1400mm sweep, 230 Volts, AC (after opening and taking out burnt winding) with suitable size of super enameled copper winding wire as per existing/ original specification of fan including proper insulation with material & insulating varnish etc and testing on full load complete all as specified and directed.
75M&L for rewinding of burnt exaust fan (after opening and taking out burnt winding) with suitable size of super enameled copper winding wire as per existing/ original specification of exaust fan including proper insulation with material & insulating varnish etc and testing on full load complete all as specified and directed for the following sizes:-
76380mm sweep, 230 Volt, AC 900 RPM.
77450mm sweep, 230 Volt, AC 1400 RPM.
78Taking down of ceiling fan/wall mounted/cabin fan/exhaust fans/Air circulator fan/pedestal fan of any size/ sweep/make from any height of building & dismantling/ opening of blade, stator rotor of ceiling fan for cleaning and servicing/ over hauling by providing oil /grease to the bearings/ bushes and replacement of defective/wornout parts/ spares i.e condenser, bearing, bush, canopy, rubeer reel, MS clamp with nut, bolt & washers and locking split pin and reassembling, commissioning testing of ceiling fan including hanging the same on existing location/ place complete all as specified and directed. Note:-Replacement/repair of defective/ wornout parts/ spares of fan i.e condenser, bearing, bush, canopy rubber reel, MS clamp and nut, bolt, washers & locking split pin shall be measured and paid separately under respective items as "S&F ".
79S&F bush/ bearing suitable for ceiling fans, exhaust fans, wall mounted and pedestal fans of any size & type complete all as specified and directed.
80S&Fball bearing suitable for exhaust fans, air circulating fan, wall mounted and pedestal fans of size/ Nos. 6201/ 6202 complete all as specified and directed. Make:- SKF/ NBC/ TATA.
81S&Fball bearing suitable for exhaust fans, air circulating fan, wall mounted and pedestal fans of size/ Nos. 6103/6204 complete all as specified and directed. Make:- SKF/ NBC/ TATA.
82S&Frubber reel of suitable sizes for ceiling fans of any size complete all as specified and directed.
83S&FMS clamps suitable size as per sample for hanging the ceiling fans complete all as specified and directed.
84S&F in repairof 15mm bore heavy duty MS down rod of 300mm long for hanging ceiling fans complete all as specified and directed.
85S&Fin repair of 15mm bore heavy duty MS down rod of 450mm long for hanging ceiling fans complete all as specified and directed.
86S&F canopy off sizes suitable for celing fans of 1200/ 1400mm sweep complete all as specified and directed.
87S&Fcondenser 2.5-4.0 mfd suitable for ceiling fans, desert cooler fans, exhaust fans, wall mounted and pedustrial fans of any type & size complete all as specified and directed.
88S&F in repair of ceiling fan mini regulator electronic type (5 step) complete all as specified & directed.
89M&L for two coat of spray painting with and including synthetic enamel paint of approved colour on all exposed surfaces of ceiling/ air circulator/ pedestal/ exhaust fan after filling of cavities with filler, surface cleaning and preparing of surfaces by using emery paper on around body with bladescomplete all as specified and directed.
90Taking down old u/s sub main wiring 2.5/4.0/6.0 Sqmm copper including batten/ conduit and making good disturbed surface to match the existing surface complete all as directed.
91S&F "C" series MCB SP, 6 to 32 Amps, 240volts, 50Hz , 10kA complete all as specified &directed.
92S&F "C" series MCB SPN, 40 to 63 Amps, 240volts, 50Hz , 10kA complete all as specified &directed.
93M&Lfor sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FR PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 4.0 sqmm drawn in and including PVC conduit not less than 25mm dia with its accessories all as specifiedand directed.
94M&Lfor sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with two runs of single core FR PVC insulated, unsheathed, mutistranded copper conductor cable (Red&Black colour) of size 6.0 sqmm drawn in and including PVC conduit not less than 25mm dia with its accessories all as specified and directed.
95Taking out existing defective/unserviceable and renewal with new out door unit of split type 1.5 TR complete with all accessories all as per existing size and make complete all as specified and directed by Engr-in-charge.
96Taking out existing defective/unserviceable and renewal with new out door unit of split type 2.0 TR complete with all accessories all as per existing size and make complete all as specified and directed by Engr-in-charge.
97Taking out existing defective/unserviceable and renewal with new indoor unit split type 1.5 TR complete with all accessoriesall as per existing size and make complete all as specified and directed by Engr-in-charge.
98Taking out existing defective/unserviceable and renewal with new indoor unit split type 2.0 TR complete with all accessory all as per existing size and make complete all as specified and directed by Engr-in-charge. Note for item No 89 to 92:- Charging of refrigerant gas R-22/ M-22 shall be measured and paid separately under respective item of BOQ/ Sch`A" as "material and labour"
99M&L for repair of unsv PCB including replacement of unsv IC/diode or connected items and refixing the same to same location including commissioning and testing all as specified and directed by Engr-in-charge.
100M&L for repairing of air curtain including replacement of unserviceable parts and control wiring, limit switch,/sensor or any wiring/circuitory, IC/diode etc all as specified and directed by Engr-in-charge.
101M&L for fixing of outdoor unit of split AC of any capacity on existing surface with fastner/nut bolts and making good surfacecommissioning and testingg all as specified and directed by Engr-in-charge.
102Disconnecting of the unserviceable voltage stabilizers capacity upto 10 KVA from the site and removing to workshop for repair and re-fixing/testing/commissioning at the original position after rewinding / replacement of parts/spares to the extent required /reassembling complete all as specified and directed. Note :- Spares/parts shall be measured and paid seperately under respective items of BOQ as " Supply only".
103Supply only main transformer with super enameled copper wire proper insulated upto 5 KVA capacity for volatage stabilizer complete as specified and directed.
104Supply only control transformer with super enameled copper wire proper insulated upto10 KVA capacity for volatage stabilizer complete as specified and directed.
105Supply only operating/control relay for stabilizer capacity upto 10 KVA complete as specified and directed.
106Supply only low/high voltage cut off and TDR system for stabilizer capacity upto 10 KVA complete as specified and directed.
107Supply only IC controlled circuit for stabilizer capacity upto 10 KVA complete as specified and directed.
108Supply only volt meter suitable for voltage stabilizer 0 to 300 volts analog/digital type complete all as specified and directed
109S&F in repair contactor suitable for split type ACs of capacity 3.0/ 4.0TR including connections complete all as specified and directed.
110S&F in repair phase preventor suitable for split type ACs of capacity 3.0/ 4.0TR including connections complete all as specified and directed.
111S&F in repair of printed control board of indoor unit and outdoor unit both of SplitAC (inverter type) Cap 1.5/2.0 TR as per sample complete all as specified and as directed
112Taking outof old, unserviceable worn out existing mild steel stand of any size and S&F in new factory made MS stand of suitable size for mounitng of split AC 1.5/2.0 TR duly grouted on wallsby using PCC 1:2:4 Bo (using 12.5mm graded aggregate)painted the steel surfaces with two coat of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed.
113Supply only suction valve with dead end cap for outdoor unit of split type air conditioner 1.5/2.0 TR as per existing at site all as specified and as directed.
114Supply only discharge valve with dead end cap for outdoor unit of split type air conditioner 1.5/2.0 TR as per existing at site all as specified and as directed.
115S&F exhaust Fan steel body AC single phase 380mm sweep 900 RPMturbo force SP with blades, frame and louvers complete including taking doun of unserviceable exhaust fans any capacity and depositing to MES store yard all as specified and directed.Make Havells/Bajaj or equivalent.