Tender For Supply Of Equipment/Material, Design, Erctiontesting & Commissioning For Providing Sop To Public Electrical Vehicle Charging Station Proposed At Mhshd Nayyar Fillingstation At Sultanpur Chowk By Providing 11/0.4 Kv 100 Kva Sub-Station In (E) Se, chamba-Himachal Pradesh

Himachal Pradesh State Electricity Board-HPSEB has published Tender For Supply Of Equipment/Material, Design, Erctiontesting & Commissioning For Providing Sop To Public Electrical Vehicle Charging Station Proposed At Mhshd Nayyar Fillingstation At Sultanpur Chowk By Providing 11/0.4 Kv 100 Kva Sub-Station In (E) Se. Submission Date for this Tender is 08-02-2024. Electrification Work Tenders in chamba Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41962203
Tender For Supply Of Equipment/Material, Design, Erctiontesting & Commissioning For Providing Sop To Public Electrical Vehicle Charging Station Proposed At Mhshd Nayyar Fillingstation At Sultanpur Chowk By Providing 11/0.4 Kv 100 Kva Sub-Station In (E) Se
Open Tender
Indian
Himachal Pradesh
chamba
08-02-2024

Tender Details

Tender For Supply Of Equipment / Material, Design, Erctiontesting & Commissioning For Providing Sop To Public Electrical Vehicle Charging Station Proposed At Mhshd Nayyar Fillingstation At Sultanpur Chowk By Providing 11 / 0.4 Kv 100 Kva Sub-Station In ( E ) Section Sultanpur Under Esd Hpsebl Chamba No-I.-Sop To Public Electrical Vehicle Charging Station Proposed At Mhshd Nayyar Fillingstation [ ( P ) 11 / 0.4Kv 100 Kva S / Stn -Supply Part ] 2 11 / 0.4 Kv 100 Kva Dtr ( Rec Sep. Ord 11 / 1976 ) 3 Prov. St Pole 9 Mtr Long W / L 200 Kgs 4 Muff For Steel Tubular Pole With Concrete Filling 5 X-Arm ( Channel Iron 100X50x5 Mm, Length 2800Mmx2 Nos. ) 6 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx1 Nos. For Las 7 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length 2800Mmx4 Nos. ] For Supporting Do Fuse Unit & Go Switch 8 X-Arm ( Channel Iron 100X50x6 Mm, Length 2800Mmx2 Nos. ) For Transformer Bed 9 X-Arm ( Channel Iron 100X50x6 Mm, Length 460 Mmx2 Nos. ) For Supporting Main Channel Of Transformer 10 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx2 Nos. 11 M.S Angle Iron ( 35X35x5 Mm ) Length :460 Mm X 2 Nos. For Bed Knee Bracing 12 M.S A.I ( 50X50x6 Mm ) Length 950 Mmx2 Nos. 13 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx2 Nos. For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 14 M.S A.I ( 50X50x6 Mm ) Length 450 Mmx1 Nos. For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 15 G.O Switch Handling Supporting: [ C.I ( 75X40x6mm ) ; Length 460 Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 16 G.O Ab Swicth Unit ( 11 Kv, 400 A, 63Ka ) Triple Pole O / D Type 17 D.O Fuse Unit Assembly 18 Surge Arrestor, 9Kv ( Station Class ) 19 Disc Insulator Sets ( Comprising 1 No. Disc ^^ ( Porcelain, Bs, 12Kv, 90 Kn ) I / C Dead End Clamp, Ball Cleave Eye Socket Etc. 20 11 Kv Pin Insulator 21 Stay Set Complete 22 Stay Wire ( 7 / 3.15 Mm ) ( 10 Kg Per Set ) 23 Pipe Earthing With Gi, Charcoal & Salt 24 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 25A, 4 No. Rewirable ) For 100 Kva Trf As Per Specification 25 Half Clamp ( Ms Flat 50X6 ) 26 Full Clamp ( Ms Flat 50X6 ) 27 Stay Clamp 28 Ms Nuts And Bolts Off Sizes ( Galvanized Coated ) ( Preferably 16 Mm Or More ( With Flat And Spring Washer ) 29 Aluminium Thimbles 30 Copper Thimbles 31 Danger Plate 32 Barbed Wire ( Rec Spf 3 / 1981 ) 33 Lt Cable 3-1 / 2 Core-120 Mm Sq. 34 Ab Cable 3X120x+90 Sq. Mm ( Lt Distribution To Panel Box ) 35 Aluminium Paint 36 Red Oxide Paint 37 Prov. Acsr Conductor 6 / 1 / 3.35 38 Lt Switched Capacitors For 100 Kva Dtr ( 36 Kvar ) 39 Prov. Transformer Bed Plinth For 100 Kva S / Stn Structure Complete With Cc 1:6:12 R.R Masonry & Plastering Etc. A / W Chain Link Fencing, Angle Iron Gate Etc. For Dtr Fencing 40 [ ( P ) 11 / 0.4Kv 100 Kva S / Stn -Erection Part ] 41 11 / 0.4 Kv 100 Kva Dtr ( Rec Sep. Ord 11 / 1976 ) 42 Prov. St Pole 9 Mtr Long W / L 200 Kgs 43 Muff For Steel Tubular Pole With Concrete Filling 44 X-Arm ( Channel Iron 100X50x5 Mm, Length 2800Mmx2 Nos. ) 45 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx1 Nos. For Las 46 X-Arm: [ Channel Iron ( 75X40x5 Mm ) , Length 2800Mmx4 Nos. ] For Supporting Do Fuse Unit & Go Switch 47 X-Arm ( Channel Iron 100X50x6 Mm, Length 2800Mmx2 Nos. ) For Transformer Bed 48 X-Arm ( Channel Iron 100X50x6 Mm, Length 460 Mmx2 Nos. ) For Supporting Main Channel Of Transformer 49 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx2 Nos. 50 M.S Angle Iron ( 35X35x5 Mm ) Length :460 Mm X 2 Nos. For Bed Knee Bracing 51 M.S A.I ( 50X50x6 Mm ) Length 950 Mmx2 Nos. 52 M.S A.I ( 50X50x6 Mm ) Length 2800 Mmx2 Nos. For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 53 M.S A.I ( 50X50x6 Mm ) Length 450 Mmx1 Nos. For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 54 G.O Switch Handling Supporting: [ C.I ( 75X40x6mm ) ; Length 460 Mm For Transformer Lt Distribution Box And G.O Switch Fixing Assembly 55 G.O Ab Swicth Unit ( 11 Kv, 400 A, 63Ka ) Triple Pole O / D Type 56 D.O Fuse Unit Assembly 57 Surge Arrestor, 9Kv ( Station Class ) 58 Disc Insulator Sets ( Comprising 1 No. Disc ^^ ( Porcelain, Bs, 12Kv, 90 Kn ) I / C Dead End Clamp, Ball Cleave Eye Socket Etc. 59 11 Kv Pin Insulator 60 Stay Set Complete 61 Stay Wire ( 7 / 3.15 Mm ) ( 10 Kg Per Set ) 62 Pipe Earthing With Gi, Charcoal & Salt 63 Prov. Lt Distribution Panel With Mccb ( 100 A, 10 Ka, 4P, 1 No. ) & Sfu ( 25A, 4 No. Rewirable ) For 100 Kva Trf As Per Specification 64 Half Clamp ( Ms Flat 50X6 ) 65 Full Clamp ( Ms Flat 50X6 ) 66 Stay Clamp 67 Ms Nuts And Bolts Off Sizes ( Galvanized Coated ) ( Preferably 16 Mm Or More ( With Flat And Spring Washer ) 68 Aluminium Thimbles 69 Copper Thimbles 70 Danger Plate 71 Barbed Wire ( Rec Spf 3 / 1981 ) 72 Lt Cable 3-1 / 2 Core-120 Mm Sq. 73 Ab Cable 3X120x+90 Sq. Mm ( Lt Distribution To Panel Box ) 74 Aluminium Paint 75 Red Oxide Paint 76 Prov. Acsr Conductor 6 / 1 / 3.35 77 Lt Switched Capacitors For 100 Kva Dtr ( 36 Kvar ) 78 Ct / Pt Unit Assembly-Supply Part 79 Prov. 11 Kv Ct-Pt Unit I.E Pt ( 1 Unit, 11 Kv / 110 V ) : Ct ( 3 No. 50 / 5A ) Accuracy Class 0.5 S 80 Prov. Energy Meter ( 3 Phase, 4 Wire ) Ht Ct Type For Above 81 Pvc Multistarnad 4 Mm Sq. Copper Wire With 1 Inch Gi Pipe For Concealing 82 X-Arm : [ Channel Iron ( 100X50x6mm ) , Length : 460 Mm X2 Nos. ) For Supporting Main Channel For Ct-Pt Unit 83 Ct-Pt Unit Belting And Knee-Bracing 84 Ms Angle Iron ( 50X50x5mm ) Length 2800Mx 4 Nos. 85 Ms Angle Iron ( 35X35x5 Mm ) , Length 2800 Mm X2 Nos. 86 Half Clamp ( Ms Flat 50X6 ) 87 Full Clamp ( Ms Flat 50X6 ) 88 Nuts & Bolts Off Sizes 89 Aluminium Thimble 90 Copper Thimbles 91 Ct / Pt Unit Assembly-Erection Part 92 Prov. 11 Kv Ct-Pt Unit I.E Pt ( 1 Unit, 11 Kv / 110 V ) : Ct ( 3 No. 50 / 5A ) Accuracy Class 0.5 S 93 Prov. Energy Meter ( 3 Phase, 4 Wire ) Ht Ct Type For Above 94 Pvc Multistarnad 4 Mm Sq. Copper Wire With 1 Inch Gi Pipe For Concealing 95 X-Arm : [ Channel Iron ( 100X50x6mm ) , Length : 460 Mm X2 Nos. ) For Supporting Main Channel For Ct-Pt Unit 96 Ct-Pt Unit Belting And Knee-Bracing 97 Ms Angle Iron ( 50X50x5mm ) Length 2800Mx 4 Nos. 98 Ms Angle Iron ( 35X35x5 Mm ) , Length 2800 Mm X2 Nos. 99 Half Clamp ( Ms Flat 50X6 ) 100 Full Clamp ( Ms Flat 50X6 ) 101 Nuts & Bolts Off Sizes 102 Aluminium Thimble 103 Copper Thimbles

Key Value

Document Fees
INR 590 /-
EMD
INR 6030.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Tender for supply of equipment/material, design, erctiontesting & commissioning for providing SOP to Public Electrical Vehicle Charging Station proposed at MHSHD Nayyar FillingStation at Sultanpur Chowk by providing 11/0.4 kV 100 kVA Sub-station in (E) section Sultanpur under ESD HPSEBL CHamba No-I.
Sl. No. Item Description
1SOP to Public Electrical Vehicle Charging Station proposed at MHSHD Nayyar FillingStation [(p) 11/0.4kV 100 kVA S/stn -Supply Part]
211/0.4 kV 100 kVA DTR ( REC Sep. Ord 11/1976)
3Prov. ST Pole 9 mtr long W/L 200 kgs
4Muff for steel tubular pole with concrete filling
5X-arm ( Channel Iron 100x50x5 mm, length 2800mmx2 Nos. )
6M.S A.I (50x50x6 mm)Length 2800 mmx1 Nos. For LAs
7X-Arm: [ Channel Iron (75x40x5 mm), Length 2800mmx4 Nos.] for supporting DO fuse Unit & GO Switch
8X-arm ( Channel Iron 100x50x6 mm, length 2800mmx2 Nos. ) for transformer bed
9X-arm ( Channel Iron 100x50x6 mm, length 460 mmx2 Nos. ) for supporting Main Channel of Transformer
10M.S A.I (50x50x6 mm)Length 2800 mmx2 Nos.
11M.S Angle Iron (35x35x5 mm) Length :460 mm x 2 nos. For bed knee bracing
12M.S A.I (50x50x6 mm)Length 950 mmx2 Nos.
13M.S A.I (50x50x6 mm)Length 2800 mmx2 Nos. For transformer LT Distribution Box and G.O Switch fixing assembly
14M.S A.I (50x50x6 mm)Length 450 mmx1 Nos. For transformer LT Distribution Box and G.O Switch fixing assembly
15G.O Switch handling supporting: [C.I (75x40x6mm); length 460 mm for Transformer LT Distribution Box and G.O Switch fixing assembly
16G.O AB Swicth unit (11 kV, 400 A, 63KA) Triple pole O/D Type
17D.O Fuse Unit assembly
18Surge arrestor, 9kV ( Station Class)
19Disc Insulator sets ( comprising 1 No. Disc ^^( Porcelain, BS, 12kV, 90 kN) i/c dead end clamp, ball cleave eye socket etc.
2011 kV Pin Insulator
21Stay Set Complete
22Stay wire(7/3.15 mm) (10 kg per set)
23Pipe earthing with GI, Charcoal & Salt
24Prov. LT Distribution Panel with MCCB (100 A, 10 kA, 4P, 1 No.) & SFU (25A, 4 No. Rewirable) for 100 kVA Trf as per specification
25Half Clamp (MS Flat 50x6)
26Full Clamp (MS Flat 50x6)
27Stay Clamp
28MS Nuts and Bolts off sizes ( Galvanized coated) (preferably 16 mm or more( with flat and spring washer)
29Aluminium Thimbles
30Copper Thimbles
31Danger Plate
32Barbed Wire (REC SpF 3/1981)
33LT Cable 3-1/2 core-120 mm sq.
34AB Cable 3x120x+90 sq. Mm ( LT Distribution to Panel Box)
35Aluminium Paint
36Red Oxide Paint
37Prov. ACSR conductor 6/1/3.35
38LT Switched Capacitors for 100 kVA DTR ( 36 kVAr)
39Prov. Transformer Bed plinth for 100 kVA s/stn structure complete with CC 1:6:12 R.R Masonry & plastering etc. a/w Chain link fencing, Angle Iron Gate etc. For DTR fencing
40[(p) 11/0.4kV 100 kVA S/stn -Erection Part]
4111/0.4 kV 100 kVA DTR ( REC Sep. Ord 11/1976)
42Prov. ST Pole 9 mtr long W/L 200 kgs
43Muff for steel tubular pole with concrete filling
44X-arm ( Channel Iron 100x50x5 mm, length 2800mmx2 Nos. )
45M.S A.I (50x50x6 mm)Length 2800 mmx1 Nos. For LAs
46X-Arm: [ Channel Iron (75x40x5 mm), Length 2800mmx4 Nos.] for supporting DO fuse Unit & GO Switch
47X-arm ( Channel Iron 100x50x6 mm, length 2800mmx2 Nos. ) for transformer bed
48X-arm ( Channel Iron 100x50x6 mm, length 460 mmx2 Nos. ) for supporting Main Channel of Transformer
49M.S A.I (50x50x6 mm)Length 2800 mmx2 Nos.
50M.S Angle Iron (35x35x5 mm) Length :460 mm x 2 nos. For bed knee bracing
51M.S A.I (50x50x6 mm)Length 950 mmx2 Nos.
52M.S A.I (50x50x6 mm)Length 2800 mmx2 Nos. For transformer LT Distribution Box and G.O Switch fixing assembly
53M.S A.I (50x50x6 mm)Length 450 mmx1 Nos. For transformer LT Distribution Box and G.O Switch fixing assembly
54G.O Switch handling supporting: [C.I (75x40x6mm); length 460 mm for Transformer LT Distribution Box and G.O Switch fixing assembly
55G.O AB Swicth unit (11 kV, 400 A, 63KA) Triple pole O/D Type
56D.O Fuse Unit assembly
57Surge arrestor, 9kV ( Station Class)
58Disc Insulator sets ( comprising 1 No. Disc ^^( Porcelain, BS, 12kV, 90 kN) i/c dead end clamp, ball cleave eye socket etc.
5911 kV Pin Insulator
60Stay Set Complete
61Stay wire(7/3.15 mm) (10 kg per set)
62Pipe earthing with GI, Charcoal & Salt
63Prov. LT Distribution Panel with MCCB (100 A, 10 kA, 4P, 1 No.) & SFU (25A, 4 No. Rewirable) for 100 kVA Trf as per specification
64Half Clamp (MS Flat 50x6)
65Full Clamp (MS Flat 50x6)
66Stay Clamp
67MS Nuts and Bolts off sizes ( Galvanized coated) (preferably 16 mm or more( with flat and spring washer)
68Aluminium Thimbles
69Copper Thimbles
70Danger Plate
71Barbed Wire (REC SpF 3/1981)
72LT Cable 3-1/2 core-120 mm sq.
73AB Cable 3x120x+90 sq. Mm ( LT Distribution to Panel Box)
74Aluminium Paint
75Red Oxide Paint
76Prov. ACSR conductor 6/1/3.35
77LT Switched Capacitors for 100 kVA DTR ( 36 kVAr)
78CT/PT Unit assembly-supply part
79Prov. 11 kV CT-PT Unit i.e PT (1 Unit, 11 kV/110 V) : CT (3 No. 50/5A) accuracy class 0.5 s
80Prov. Energy meter (3 Phase, 4 Wire ) HT CT type for above
81PVC Multistarnad 4 mm sq. Copper wire with 1 inch GI pipe for concealing
82X-arm : [ Channel Iron (100x50x6mm), Length : 460 mm x2 Nos.) for supporting main channel for CT-PT Unit
83CT-PT Unit Belting and knee-bracing
84MS Angle Iron (50x50x5mm) Length 2800mx 4 Nos.
85MS Angle Iron( 35x35x5 mm), Length 2800 mm x2 Nos.
86Half Clamp (MS Flat 50x6)
87Full Clamp (MS Flat 50x6)
88Nuts & Bolts off sizes
89Aluminium Thimble
90Copper Thimbles
91CT/PT Unit assembly-Erection part
92Prov. 11 kV CT-PT Unit i.e PT (1 Unit, 11 kV/110 V) : CT (3 No. 50/5A) accuracy class 0.5 s
93Prov. Energy meter (3 Phase, 4 Wire ) HT CT type for above
94PVC Multistarnad 4 mm sq. Copper wire with 1 inch GI pipe for concealing
95X-arm : [ Channel Iron (100x50x6mm), Length : 460 mm x2 Nos.) for supporting main channel for CT-PT Unit
96CT-PT Unit Belting and knee-bracing
97MS Angle Iron (50x50x5mm) Length 2800mx 4 Nos.
98MS Angle Iron( 35x35x5 mm), Length 2800 mm x2 Nos.
99Half Clamp (MS Flat 50x6)
100Full Clamp (MS Flat 50x6)
101Nuts & Bolts off sizes
102Aluminium Thimble
103Copper Thimbles
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail