| 1 | SCHUDULE \"A\" PART I (SPECIAL REPAIR OF INTERNAL WIRING OF OTHER THAN MARRIED ACCOMMODATION FOR HQ 25 SECTOR) |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired. |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required |
| 4 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 5/6 amps switch |
| 9 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 15/16 amp switch. |
| 10 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 3 pin 5/6 amp socket outlet. |
| 11 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 6 pin 15/16 amp socket outlet |
| 12 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required Telephone socket outlet |
| 13 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required Bell push. |
| 14 | Supplying and fixing metal box of 75 mm X75 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 15 | Supplying and fixing metal box of 200 mm X150 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 16 | Supplying and fixing metal box of 200 mm X 250 mm X 60 mm deep mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 17 | Supplying and fixing metal box of 100mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required |
| 18 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 19 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steeletc. as requiredenclosure,surface or in recess, with chained metal cover for the socket out on let and complete with connections, testing and commissioning |
| 20 | Supplying and fixing 2 way stepped type electronic fan regulator230 volt AC on the existing switch box including connections as required. |
| 21 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 22 | Supplying and fixing brass batten/PVC angle holder including connection etc. as required. |
| 23 | Supplying and fixing 4 way (4 + 12), Single door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 24 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of triplepole & neutralin the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 25 | Supplying and fixing 12 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator |
| 26 | Supplying and fixing 8 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\"curve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 29 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 30 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 31 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 32 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 33 | SCHUDULE \"A\" PART II(SPECIAL REPAIR TO CONVERT OVER HEAD ELECTRIC LINE TO UNDER GROUND CABLE INCLUDING FEEDER PILLAR BOXES AND ALLIEDWORKS AT HQ 25 SECTORAT JORHAT.) |
| 34 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. |
| 35 | Dismantling of pole any type for street light / strut pole embedded in cement concrete foundation etc. as required. |
| 36 | Erection of steel tublar pole strut in cement concrete 1:3:6 (cement :coarse sand : stone aggregate foundation including excavations etc as required. |
| 37 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required. |
| 38 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 39 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 40 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single redcolour on front side as required. |
| 41 | Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible, FR PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or pole etc. as required. |
| 42 | Supplysteel tubular swagedpole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9 mtr long, all as specified. |
| 43 | Providing and installation of street light fitting70 watt LED type complete with all as specified. |
| 44 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finishpaint etc. as required. |
| 45 | Supply, fixing and connecting MS junction box of size 250x200x150 mm made out of MS sheet 16 gauge, duly powder coated ( inside and out side ) complete including MCB SP 16 Amp with 4 Nos Al bus bars of 25 mm x3 mm size, fixed on porcelain support with hinged cover & locking arrangement fixed to electric pole by means of clamps of MS flat iron 25x6mm with bolts,nuts and washers of suitable complete all as specified & directed. |
| 46 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sq. mm. |
| 47 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 35 sq. mm and upto 95 sq. mm. |
| 48 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 95 sq. mm and upto 185 sq. mm. |
| 49 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 185 sq. mm and upto 400 sq. mm. |
| 50 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 35 sq. mm 1.1 KV grade cable. |
| 51 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 185 sq. mm 1.1 KV grade cable. |
| 52 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 400 sq. mm 1.1 KV grade cable. |
| 53 | Brass compression gland for (82 mm) 3½ 400 sq. mm 1.1 KV grade cable. |
| 54 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 6Sqmm 2 core. |
| 55 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 10Sqmm 2 core. |
| 56 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 10Sqmm 4 core. |
| 57 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 16Sqmm 4 core. |
| 58 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 35 Sqmm 3.5 core. |
| 59 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 185 Sqmm 3.5 core. |
| 60 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 400 Sqmm 3.5 core. |
| 61 | Supply, installation, testing and commissioning in repair/ replacement ofindoor LT panel board fixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connections, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supplyofsuitable capacity aluminium bus bar fully compartmentalised mounted on epoxy insulator, dust proof and vermin proof 2.0 mm thick CRCA sheet steel enclosure powder coated suitable and all as specifiedand having the following items:-(a) .Aluminium bus bar for three phase with neutral of capacity 300 Amps -01 Set(b) Incomming :- 200 Amp, 25KA,FPMCCB -01 Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch (c)Outgoing: 160 amps 16 KATPNMCCB -3 , 100 amps16 KA TPN MCB - 2 no , 40 amps16 KA TPN MCB - 4 no. (Spare), on load changeover switch of 160 Amps 4 pole-03 on load changeover switch of 100 Amps 4 pole-02 |
| 62 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- (a) incoming: 630Amp,50KA,FPMCCB -01, 630Amp,TPN disconnectorwith HRC fuse - 03 Nos,900 A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch,03 Nos CTs & 03 NosPTsas per suitable rating (b) Outgoing:400 AmpsTPN MCCB 35 KA - 3 no.,160 Amps16 KA TPN MCCB - 1 no. 63 amps 16 KA TPN MCB - 1 no. security light 40 amps TPN MCB - 1 no. (Spare) Streer Light Auto ON/OFF system:- (i)Time switch415 volt 3 Phase of 32 Anp rating with contactor fitted inside steel enclosusre--01 No. (II)Contactor 3 Pole 415 V, 32 Amp - 01 No(iii)MCCB TP 40 Amp 10 KA - 03 Nos,(iv) Toggle switch 16 Amp -01 Nos, (v)Heavy duty conector - 03 Nos,(vi)Neutral Link copper - 01 No. |
| 63 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- (a) incoming :-:200 Amp,36 KA,FP MCCB-01, 300A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch, (b)Outgoing::- 63 amps TPN MCB - 5 no. |
| 64 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- (a)Incoming: 100 Amp,36 KA,TPN MCCB- 1,200A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch,(b) Outgoing::- 40 amps TP MCB - 4 no.32 amps TP MCB - 2 no. |
| 65 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- (a) Incoming:- 100 Amp,36 KA,TPN MCCB- 1,200A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch (b) Outgoing:- :63 amps TP MCB - 7 no. |
| 66 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- (a)Incoming: 100 Amp,36 KA,TPN MCCB- 1,150A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch, (b) Outgoing::-63 amps TP MCB - 3 no. |
| 67 | Supply, installation, testing and commissioning outdoor LT panel board CRCA made thickness 3.15 mmfixed on angle iron frame of 50x50x5mm(thick)double door opening with locking arrangment,including necessary incoming & outgoing cable connectons, cable glands, thimbles of required sizes working on 440 Volt 3 phase, 50 HZ, AC supply fully compartmentalised mounted on epoxy insulator, dust proof and vermin proo thick CRCA sheet steel enclosure powder coated suitable and all as specified and having the following items (Main panel):- :-(a)Incoming:63 Amp,36 KA,FP MCCB,100A TPN Busbar, Phase Indication Lamp, Voltmeter, Ammeter with Selector Switch, (b) Outgoing::-40 ampsDP MCB - 8 no. |
| 68 | Laying 15 cm dia RCC Hume pipe withcollar depth up to 90 cm , for enclosingcable & necessary back fillingto make even surface. |
| 69 | providing and fixing LT line separator as per specification and directed. |
| 70 | SCHUDULE \"A\" PART- III (SPECIAL REPAIR AND ENHACEMENT OF ELECTRIC SUPPLY SYSTEM AT HQ 25 SECTOR) |
| 71 | Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 72 | Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts,washers etc. as required. |
| 73 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 74 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for 3½ X 50sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 75 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for 3½ X 70 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 76 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for 3½ X 95 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 77 | supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 240 Sqmmof 3 core, XLPE aluminium conductor cable of 11 KV grade as required. |
| 78 | supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 240 Sqmmof 3 core, XLPE aluminium conductor cable of 11 KV grade as required. |
| 79 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required. |
| 80 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps,bolts, nuts and washer etc including drilling of holes for insulator bolts, nuts and washer etc including drilling of holes for insulator bolts, nuts and washer etc including drilling of holes for insulator bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. |
| 81 | Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required. |
| 82 | Material and labour for cleaning of surface of the transformer of any capacityup to 400 KVA by hand scraper and removing the oil mark and applying two coats of synthetic enamel paintsuitable to the existing colour all as directed. |
| 83 | Disconnection oftransformer 11 / 0.433 KVoutdoor type of capacity 500/400 KVA removing primaryand secondary terminals top cover with conservator tank neutral earth strip and draining out transformer oil and storeing to clean container ,cleaning of terminals , inspection of cores , supplyand replacement 5 mm thick rubberised cork sheet gasket for tankcover, reassembling the complete dismantled items , reconnecting HT/LT supply cable endscomplete all as directed by Engr- in Charge. |
| 84 | M&L required T&P fortaking out of transformer 11/0.433 KV 500/400KVA capacityfrom existing position for necessaryrepairingwork after repair, reassembling, reconnecting in the system and testing all as specified. |
| 85 | Filtration of transformer oil outdoor type to achieving electric strength up to 40 KV for one minut at 4 mm gap as per relevant IS with portable filtration plant , testing of oil for di electric strength before and after filtration shall be conducted allas specified by the Engr- iin - Charge Note :- Test report after filtration to be produced to Dept. |
| 86 | Supply and fixing Gang operated air breaker switch triple pole vertical type 11KV for current rating up to 150 Amps double stacktype mech operated mounted on insulator and steel frame with operating mechanisamwork from ground levelincluding operating rod GI tubing 25 mm dia medium grade single piece of 6.2 RM and handle complete including locking arrangementcomplete all as specified and directed by Engineer in Charge.Note- The AB switch shall be consist of 3 insulators per phase and 18 isolators. |
| 87 | Supply & fixingdrop out (DO) fuse unit expulsion type out door type 150 Amps rating single pole mounted in two insulators fixed to and including MS channel with nut bolt and washer, Synthetic bounded fuse carrying tube complete with HT fuse element up to 25 A capacity for HT 11 KV working pressure etc., complete all as specified and directed. |
| 88 | Material forACSR Conductor5 of 5 of 7/1X3.35 rabit for three phase line and street light and 1 of 7/2.59 mm weasel for neutral respectively. |
| 89 | Erection of ACSR conductor of 7/2.11 mm to 7/4.00 mm diameter including binding etc. as required. |
| 90 | Supplying and erection of 75 mm X 90 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required. |
| 91 | Supplying and erection of 100 mm X 80 mm pin insulator complete with G. I. Spindle and nuts etc. as required. |
| 92 | Supplysteel tubular swagedpole complete with cast iron base plate , finial taper plug , bolts , nuts & screws as specified type 410 SP-31, 9 mtr long, all as specified. |
| 93 | M& L for preparation of old painted surfaces for steel tubuler pole 11mtr longtwo pole structure including crossarms,brackets clamps,terminals cleaning by scraping and applying with two coat of aluminium paint over one coat of red oxide primer complete etc complete all as directed. |
| 94 | M& L for preparation of old painted surfaces for steel tubuler pole 9 mtr long with two coat of aluminium paint over one coat of red oxide primer complete including crossarms, brackets clamps etc complete all as directed. |
| 95 | Erection of steel tublar pole strut in cement concrete 1:3:6 (cement :coarse sand : stone aggregate foundation including excavations etc as required. |
| 96 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required. |
| 97 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 98 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 99 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single redcolour on front side as required. |
| 100 | Providing and fixing 16/0.20mm (0.50sqmm) twin flat flexible, FR PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or pole etc. as required. |
| 101 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV /HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts,bolts and washer, painting the flat iron with primer and finishpaint etc. as required. |
| 102 | Supply, fixing and connecting MS junction box of size 250x200x150 mm made out of MS sheet 16 gauge, duly powder coated ( inside and out side ) complete including MCB SP 16 Amp with 4 Nos Al bus bars of 25 mm x3 mm size, fixed on porcelain support with hinged cover & locking arrangement fixed to electric pole by means of clamps of MS flat iron 25x6mm with bolts,nuts and washers of suitable complete all as specified & directed. |
| 103 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sq. mm. |
| 104 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 35 sq. mm and upto 95 sq. mm. |
| 105 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 95 sq. mm and upto 185 sq. mm. |
| 106 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required above 185 sq. mm and upto 400 sq. mm. |
| 107 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 185 sq. mm 1.1 KV grade cable. |
| 108 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 70/95/120sq. mm 1.1 KV grade cable. |
| 109 | Outdoor cable jointing kit with cast resin compound with lugsfor 3½ X 35/50sq. mm 1.1 KV grade cable. |
| 110 | Outdoor cable jointing kit with cast resin compound with lugsfor3½ X 25 sq. mm 1.1 KV grade cable. |
| 111 | Outdoor cable jointing kit with cast resin compound with lugsfor3½ X 25 sq. mm 1.1 KV grade cable 4 pole MCCB,400A, 50KA. |
| 112 | Outdoor cable jointing kit with cast resin compound with lugsfor3½ X 25 sq. mm 1.1 KV grade cable 4 pole MCCB,250A, 50KA. |
| 113 | Outdoor cable jointing kit with cast resin compound with lugsfor3½ X 25 sq. mm 1.1 KV grade cable 3 pole MCCB, 150A, 16KA. |
| 114 | 400 amps. TPN switch fuse unit with ISI marked HRC fuses. |
| 115 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 3.5 core 185 sq mm aluminium conductor. |
| 116 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 3.5 core 95 sq mm aluminium conductor. |
| 117 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 3.5 core 70 sq mm aluminium conductor. |
| 118 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 3.5 core 50 sq mm aluminium conductor. |
| 119 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 3.5 core 35 sq mm aluminium conductor. |
| 120 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 4 core 25 sq mm aluminium conductor. |
| 121 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 4 core 16 sq mm aluminium conductor. |
| 122 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 4 core 10 sq mm aluminium conductor. |
| 123 | ProvidingXLPE armoured cable 1.1 KVof following sizeto laid in trench/ pipe as per specification 4 core 6 sq mm aluminium conductor. |
| 124 | SCHEDULED \"A\" PART IV (SCHEDULED OF CREDIT) |
| 125 | UNSV Retrived wire (It is necessary to quote at least Rs. 25/-per RM or more). |
| 126 | UNSV Retrived earthing items (It is necessary to quote at least Rs. 325/-per Set or more). |
| 127 | UNSV U/G Cable 6 Sqmm to 185 Sqmm (It is necessary to quote at least Rs. 25/-per RM or more). |
| 128 | UNSV U/G Armoured Cable 35 to 185 Sqmm (It is necessary to quote at least Rs. 30/-per RM or more). |