}

Providing Comprehensive Operation And Maintenance (O&M) Services For City Gas Distribution Network For: Group A - Muzaffarpur And Samastipur District Ga, Group B - Vaishali And Saran District Ga, Group C - Arwal, Jehanabad,Bhojpur And Buxer District Ga, G, noida-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Providing Comprehensive Operation And Maintenance (O&M) Services For City Gas Distribution Network For: Group A - Muzaffarpur And Samastipur District Ga, Group B - Vaishali And Saran District Ga, Group C - Arwal, Jehanabad,Bhojpur And Buxer District Ga, G. Submission Date for this Tender is 21-02-2024. Gas Pipe Line Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41959203
Providing Comprehensive Operation And Maintenance (O&M) Services For City Gas Distribution Network For: Group A - Muzaffarpur And Samastipur District Ga, Group B - Vaishali And Saran District Ga, Group C - Arwal, Jehanabad,Bhojpur And Buxer District Ga, G
Open Tender
Indian
Uttar Pradesh
noida
21-02-2024

Tender Details

Providing Comprehensive Operation And Maintenance ( O&M ) Services For City Gas Distribution Network For: Group A - Muzaffarpur And Samastipur District Ga, Group B - Vaishali And Saran District Ga, Group C - Arwal, Jehanabad, Bhojpur And Buxer District Ga, Group D - Morena District Ga, Group E - Coimbatore District Ga, Group F - Jagtial, Peddapalle, Karimnagar And Rajanna Sircilla District Ga, Group G - Jhunjhunu, Sikar And Nagaur District Gagroup H - Dharmapuri And Krishnagiri District Ga

Key Value

Document Fees
Refer document
EMD
INR 255000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVIDING COMPREHENSIVE OPERATION AND MAINTENANCE (O&M) SERVICES FOR CITY GAS DISTRIBUTION NETWORK FOR: GROUP A - MUZAFFARPUR AND SAMASTIPUR DISTRICT GA, GROUP B - VAISHALI AND SARAN DISTRICT GA, GROUP C - ARWAL, JEHANABAD,BHOJPUR AND BUXER DISTRICT GA, GROUP D - MORENA DISTRICT GA, GROUP E - COIMBATORE DISTRICT GA, GROUP F - JAGTIAL, PEDDAPALLE, KARIMNAGAR AND RAJANNA SIRCILLA DISTRICT GA, GROUP G - JHUNJHUNU, SIKAR AND NAGAUR DISTRICT GA GROUP H - DHARMAPURI AND KRISHNAGIRI DISTRICT GA
Sl. No. Item Description
1WORKS IN THE STATE OF MADHYA PRADESH
2Establishing Area Emergency Office (AEO) , Local Customer Care Office (LCO) , Hiring of ERV, Hiring of Motor Cycle for Patrolling and Meter Reading Charges
3Hiring of space for Area Emergency Office(AEO)with necessary facilities viz.; Office space for O&M team, Pantry, toilet, ERV parking, Stores for spares/ fittings (including free issue material), Tools & tackle, Telephones,air conditioners, Furnitures, visitor waiting chairs (metal perforated bench chairs), etc.Detailed in line with Technical specification of Tender. Minimum area of 1500 Square Feet in a single floor with sufficient space for stores and parking facilities
4Providing ER Vehicle with driver (Mahindra Pick-up/ TATAPick-up/ Equivalent) 24x7 for Routine and Break down maintenance works at site. Vehicle should be latest model fitted with GPS Tracking device and adequate space to carry consumables tools & tackles for various O&M activities, Fire and Safety apparatus, PPEs, first aid box & shall also be equiped with 5Kva generator set with Emergency Light. Minimum ERV run of 2000km per month with start and terminationpoint will be AEO office or as decided by EIC.Operation & Maintenance cost for ERV including fuel cost, driver’s cost, and spares/consumables cost for proper up-keeping of the vehicle and or any other cost pertaining to the ERV as well as drivers are to be borne by the contractor. Note: Escalation of price as per increase or decrease of fuel price above 10% as per escalation clause of Tender.
5Extra running km of ERV over and above 2000 Km per month
6Hiring of Motorcycle for pipeline surveillance personnel & technician with GPS enabled mobile devices for monitoring and surveillance & safety, maintenance of IOCL’s Pipelines/ Installations etc. Minimum motorcycle run of 3000 km per month with start and termination point will be AEO office or as decided by EIC. (Zone wise Bike for Pipeline surveillance designated person /LCO is considered and may be provided to Technician for Maintenance on the recommendation of EIC (If required). Latest Model or later having capacity at least 100/125 CC Note: No price Escalation for Motorcycle is being envisaged in the tender.
7Extra running km of Motor Cycle over and above 3000 Km per month
8Supply of Materials under Contractor"s scope
9Supply of PE Electrofusion fittings as per tender documents
10Supply of Reducer 125 x 90 mm
11Supply of Reducer 125 x 63 mm
12Supply of Reducer 90 X 63 mm
13Supply of Reducer 63 X 32 mm
14Supply of Reducer 32 X 20 mm
15Supply of Coupler 125 mm
16Supply of Coupler 90 mm
17Supply of Coupler 63 mm
18Supply of Coupler 32 mm
19Supply of Coupler 20 mm
20Supply of Equal Tee 125 mm
21Supply of Equal Tee 90 mm
22Supply of Equal Tee 63 mm
23Supply of Equal Tee 32 mm
24Supply of Equal Tee 20 mm
25Supply of End Cap 125 mm
26Supply of End Cap 90 mm
27Supply of End Cap 63 mm
28Supply of End Cap 32 mm
29Supply of End Cap 20 mm
30Supply of Saddle 125 x 63 mm
31Supply of Saddle 125 x 32 mm
32Supply of Saddle 90 x 63 mm
33Supply of Saddle 90 x 32 mm
34Supply of Saddle 90 x 20 mm
35Supply of Saddle 63 x 32 mm
36Supply of Saddle 32 x 20 mm
37Supply of Saddle 63 X 20 mm
38Supply of Elbow (90°) 125 mm
39Supply of Elbow (90°) 90 mm
40Supply of Elbow (90°) 63 mm
41Supply of Elbow (90°) 32 mm
42Supply of Elbow (45°) 125 mm
43Supply of Elbow (45°) 90 mm
44Supply of Elbow (45°) 63 mm
45Supply of Elbow (45°) 32 mm
46TF 32mm x 1"
47TF 32mm x 3/4"
48TF 20mm x 1/2"
49Installation of valve in pit including supply of PE valves Supply of isolation valves (as per data sheet) and installation of valves in the valve pits as per typical drawing and specification enclosed and instructions of Engineer-in-charge. Payment of civil construction of valve Pits shall be paid separately as per relevant SOR.
50Supply of PE Valves - 125mm
51Supply of PE Valves - 90mm
52Supply of PE Valves - 63mm
53Supply of PE Valves - 32mm
54Supply of Powder coated GI pipes ( C-Class), GI Fitting (IS 1879) and others as per tender documents
55Supply of1/2" GI Pipe
56Supply of3/4" GI Pipe
57Supply of1" GI Pipe
58Supply of1.5" GI Pipe
59Supply of Copper Tube 12mm
60GI Fitings of 1" Elbow
61GI Fitings of 3/4" Elbow
62GI Fitings of 1/2" Elbow
63GI Fitings of 1" Hex Nipple
64GI Fitings of 1/2" Hex Nipple
65GI Fitings of 3/4" Hex Nipple
66GI Fitings of 1" NB Barrel Nipple
67GI Fitings of 1/2" NB Barrel Nipple
68GI Fitings of 3/4" NB Barrel Nipple
69GI Fitings of 1" Coupling-M
70GI Fitings of 3/4" Coupling-M
71GI Fitings of 1/2" Coupling-M
72GI Fitings of 1" Plug-M
73GI Fitings of 3/4" Plug-M
74GI Fitings of 1/2" Plug-M
75GI Fitings of 1/2" hex Plug
76GI Fitings of 3/4" hex Plug
77GI Fitings of 1" hex Plug
78GI fittings 1" Union
79GI fittings 3/4" Union
80GI fittings 1/2" Union
81GI Fitings of 1 " x 1/2" Reducer-M
82GI Fitings of 3/4 " x 1/2" Tee-M
83GI Fitings of 1 " x 1/2" Tee-M
84GI Fitings of 1" Tee-M
85Supply of 3/4" x 1/2" Bush-M
86Supply of 3/4" x 1" Bush-M
87Supply of Blind Meter Adaptor- GI ( Temporary Disconnetion of Dom. Customers)
88Supply of Meter Adaptor- Brass for G-1.6 Meter(Domestic Meter)
89Supply of Meter Adaptor- Brass for G-6 Meter
90Supply of Meter Adaptor- Brass for G-10 Meter
91Supply of Meter Adaptor- Brass for G-16 Meter
92Supply of Meter Adaptor- Brass for G-25 Meter
93Supply of 1"GI Powder Coated Clamp with screw
94Replacement of SS 316 Anaconda
95Supply of Isolation & Appliance Valve
96Isolation Ball valve (1/2")
97Isolation Ball valve (3/4")
98Isolation Ball valve (1")
99Isolation Ball valve (1.5")
100Appliance valve (1/4")
101Appliance valve (1/2")
102Supply of SS Tubes,SS Fittings,& SS valves
103¾”OD X 0.095” min Wall thk., SS Material Grade TP316 / TP316L Seamless Tube as per ASTM A269
104½”OD X 0.083”min Wall thk., SS Material Grade TP316 / TP316L Seamless Tube as per ASTM A269
105End connection:½" Tube OD, for stem & ½”NPT (F) for body SS Material Grade TP316 / TP316L as per ASTM A269; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
106Plug: ¾" OD, SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
107Plug: ½" OD, SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
108Cap: ¾" OD,SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
109Cap : ½" OD,SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
110Union : ¾” OD, SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
111Union : ½" OD,SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
112Reducing Union: Tube OD 3/4" x Tube OD 1/2", SS Material Grade TP316 / TP316L as per ASTM A269 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
113Equal Tee: Size 3/4" OD x ¾" OD x ¾" OD,SS Material Grade TP316 / TP316L as per ASTM A269 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
114Equal Tee: Size 1/2" OD x ¾" OD x ¾" OD,SS Material Grade TP316 / TP316L as per ASTM A269 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
115Reducing Union Tee: ¾" OD x ½" OD x ¾" OD, SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
116Tube End Connection: ¾" OD x ½" OD x ¾" OD, SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
117Front Ferrule: 3/4" OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
118Front Ferrule: 1/2" OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
119Back Ferrule: 3/4" OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
120Back Ferrule: 1/2" OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
121Male Connector: Size ¼” NPT (M) x 3/8” OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
122Male Connector: Size 1/2” NPT (M) x 3/8” OD,SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
123SS Ball Valves: 2-Way Trunnion Mounted Normal Bore Ball Valve ¾"(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) with additional 1 set of Nuts, Backs & Front Ferrule etc.
124SS Ball Valves: 2-Way Trunnion/ Floating Normal Bore Ball Valve ½"(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) with additional 1 set of Nuts, Backs & Front Ferrule etc.
125SS Ball Valves: 3-Way Trunnion Mounted, Reducer BoreBall Valve ½" OD end Connection and ¼” NPT (F) bottom end connection(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) with additional 1 set of Nuts, Backs & Front Ferrule etc.
126Conductive Core Thermoplastic Hose: 3/8” ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling
127Cross: 3/4" OD X 3/4”X 3/4" OD X3/4" OD SS Material Grade TP316 / TP316L as per ASTM A269(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
128Supply of Steel Pipeline Leak Clamp (nominal dia 12 / 10 / 8 / 6 / 4 -inch) at designated location/ sites including transportation of leak clamp, (Standard leak clamp oflength of 60 Cm has been assumed) (As per detailed Scope of Work)
12912"
13010"
1318"
1326"
1334"
134Supply ofLiquid Epoxy Paint POWERCRETE R95 along with APPLICATOR PAD KIT
135Supply of Gasket
136Supply of Spiral Wound Metallic Gaskets (12" x 300#)
137Supply of Spiral Wound Metallic Gaskets (10" x 300#)
138Supply of Spiral Wound Metallic Gaskets (8" x 300#)
139Supply of Spiral Wound Metallic Gaskets (6" x 300#)
140Supply of Spiral Wound Metallic Gaskets (4" x 300#)
141Supply of Spiral Wound Metallic Gaskets (2" x 300#)
142Supply of Grease Gun ( Capacity-5kg)
143Supply of IOCL SERVO Grease
144Supply of Valve SEALANT INJECTION KIT(High pressure sealant injection kit with 3 packs of sealant per kit as per technical Specifications approved by EIC)
145Supply of Sealent Cartridges Audco 733 or equivalent for Valves (As per technical Specifications approved by EIC)
146O&M SERVICES - The cost include all expenses towards manpower, tools, tackles, consumables etc. required to perform the activities to the satisfaction of EIC.
147Hiring of Machine/ equipments for Maintenance work. The period ofhiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Normal working time per day will be 8 Hrs.
148Providing Hydra ( 10-12 TON capacity ) along with belts, chains, hooks etc at site for shifting heavy material or equipments like pipes, welding machine, cold cutting machine etc.The rate is inclusive of mobilisation and demobilisation cost, hiring and running cost, fuels, consumables, lube oil cost, operator cost etc., as per direction of EIC. Payment towards equipment running charges shall be made only if payments are not covered in any of the SOR items elese where in this contract.
149Hiring of Crane - 20 MT capacity
150Hiring of Ladder up to 25 Feets
151Hiring of Concrete / Rock Breaker
152MDPE pipe Line Repairing including excavation, leakage arrest, jointing and restoration of any dia up-to 63 mm including supply and installation of all fittings required. MDPE Pipe required shall be issued by Owner as free issue material. All other fittings/consumables shall be supplied by Contractor, payment of which shall be admissible as per items list in section "D". Rate of Items or Consumables which are not mentioned in section D, shall be supplied by Contractor
153MDPE pipe Line Repairing including excavation, leakage arrest, jointing and restoration of any dia above 63 mm including supply and installation of all fittings required. MDPE Pipe required shall be issued by Owner as free issue material. All other fittings/consumables shall be supplied by Contractor, payment of which shall be admissible as per items list in section "D". Rate of Items or Consumables which are not mentioned in section D, shall be supplied by Contractor
154Charges for Meter Reading for Domestic, Commercial & Industrial Connections Note: Surprise visit of metering as and when required shall be in contractor scope.
155Maintenance of PNG Connections
156Mainteance of Dom Connection- - Leakage testing (LDT) - Leakage testing (LPT with digital manometer) - Clamping, Paint Touch up - Check Meter working in gas flow condition - Leakage identification & rectification - Checking of RCC gaurd, sand filling and cementing - Checking & reporting of un-authorised extension of gas pipeline & Rubber Tube / other anomalies - Checking of Service line, Meter or Regulator "O" ring or Adaptor - Repalcement of Surakaha hose in case of damaged, expired for all Points etc. with clamp. - Replacement of o-ring for arresting the leakage from adaptor - Collect and Update customer contact details (Updation of mobile numbers (primary and secondary) and email id.
157Miantenance of Com / Non Com / NDEC Connection - Leakage testing (LDT) - Leakage testing (LPT with digital manometer) - Clamping, Paint Touch up - Check Meter working in gas flow condition - Leakage identification & rectification (alteration charges will be paid as per Alteration Line item) - Checking of RCC gaurd, sand filling and cementing - Checking and reporting of un-authorised extension of gas pipeline and Rubber Tube - Checking of Service line,Meter or Regulator "O" ring or Adaptor - Repalcement of Surakaha hose in case of damaged, expired for all Points etc. with clamp & o-ring for arresting the leakage from adaptor - Collect & Update customer contact details – mobile numbers (primary and secondary) and email id (Material will be supplied as per Section C- expect sand,cement, paint and consumables)
158Attending customer service requests and resolving the complaints in all respects as detailed in scope of work and special conditions of contract and as per directions/ instructions of EIC/ Authorized representative including but not limited to following: Venting, Flushing, Modifications, Meter/ Regulator Change, Testing, Painting, etc. in gas charged area. Installation of clamps, fittings and hardware is in scope of contractor. Any additional GI Pipe (if required) in case dismantled pipe are not healthy or short, item shall be paid as per relevant SOR item. Dismantled pipe/ fittings to be returned at Owner Store or site office as instructed by EIC.
159GI Riser Testing (Transition Fitting to Meter Isolation Valve) all sizes
160Internal Testing (Meter Isolation Valve to Appliance Valve)
161Conversion of LPG to PNG/ PNG to LPG burner
162Supply of Steel Reinforced Rubber Hose with Clamps
163Flame Problem
164Meter checking by check meter in series
165Replace Brass Connector/ Adapter
166Dismantling of GI Pipe in case modification, leakage or site requirements 3/4"
167Dismantling of GI Pipe in case modification, leakage or site requirements 1/2"
168Dismantling of Copper Pipe in case modification, leakage or site requirements
169Reinstallation and painting of GI Pipe using Old dismantled pipe 3/4"
170Reinstallation and painting of GI Pipe using Old dismantled pipe 1/2"
171Reinstallation of Copper Pipe using Old dismantled pipe
172Replacement of SS 316 Anaconda
173Replacement of meter / Regulator
174Supply & InstallationRoute Marker, Pole Marker and Plate Marker,TLPs, Warning Tape
175RCC Route Marker
176Pole Marker with Foundation
177Plate Marker
178Polyconcrete Route Marker
179Supply and Installation of Type A/Type A1/Type B/Type C/ Type D Test Lead Point (TLPs)
180Repair ofType A/Type A1/Type B/Type C/ Type D Test Lead Point (TLPs)
181Painting of Piping and Structure / Electrical Pole / Crash Barrier/ Manhole Cover (Paints and other consumables to be supplied by contractor)
182Painting of Wire mesh /Fencing(Paints and other consumables to be supplied by contractor)
183Installation of SS tubing/GI Pipes including Bending, testing & Commissioing with consumable such as teflon tap etc for 1/4", 1/2", 3/4", 3/8", 7/8".
184Welding in existing structure, pipe etc including mobilization of welder, machine for grinding, chipping etc., welding rod as approved by EIC and all other consumables required to complete the work in all respects as per instruction of EIC/site Engineer. Structural steel/pipe etc will be supplied by owner.
185Excavation, Backfilling and Coat & Wrap work
186COAT AND WRAP WORK Coat and Wrap work of welded leak clamp / over pipe length including cleaning of leak clamp and adjacent pipe section, application of primer, application of outer and inner layer of cold applied tapes. Coating Material willl be provided by IOCL
187Excavation in all types of Rock (hard / Ordinary) :Excavation Work in Rock (all types : hard / Ordinary) by mechanical means (Hydraulic / Pneumatic Excavator & Hand Operated ) and Manual means for all ty pes of Rock (Hard / Ordinary) including disposal of excavated Rock as per instruction of EIC and neaty dressed - for all type of Rock (Blasting Prohibited).This job shall also may include of depth 1meter beneath bottom surface of the pipe.Site supervision & resource to be eployed as per direction of EIC
188Backfilling of Excavated Pit / Trecnch:Backfilling of the excavated pit/trench by Hydraulic means (JCB)/Manual Means, soil (excluding rock) removed during excavation of trench (stored within 50 m radius of the excavated trench)
189Coating Removal & Peel off Test: Surface Preparation of Pipe : Removal of Three Layer Polyehylene Coating (3 LPE): Coating of the pipe surface is to be removed by mechanical means i.e. by chiesel and onward surface preparation by Grinder for cleaning the coating bond material with portable power grinder driven emery paper (duty approved by IOCL).This shall be inclusive of pipe fitter, Grinder, helper required for cleaning of the pipe surface.
190Application of Primer & Cold Tape: Supply & application of Cold Tape along with primer : The coating material should be of make Denso / RAYCHEM equivalent make of Disired Length with 67% overlapping ,, with prior application of primer on pipe surface as per manufacturer specification.This shall be inclusive of applicator along with all requisite tools, with 67% overlapping.Installation shall be acceptable only after acceptance in holiday test.Also Match stick wherever is required for minor defects
191Emergency repair works in pipeline - pipeline leak/pilferage/Burst/Third Party Damage (For items below)
192Mobilisation to site within contractual time with manpower, security guard, labour, tools, tackles, cold cutting machine, equipments and all other resources (eg JCB, compressors, dewatering pump, DG sets, dumper, trailer, welding generator, Hydra, pick-up, Dumper, tents & chairs etc) with fuels and consumables etc as outlined in tender document for execution of job. Rate is Lumpsum basis and shall be payable to contractor on complete mobilisation to site to the satisfaction of EIC. Rate of this item is also inclusive of demobilisation charges with all manpower, material and resources deployed at site after completion of work. The contractor shall also liasion with local villager, Concerned Authority, local police for safe and secure rectification of the work. Apllicable when distance between two adjacent site is more than 2.5KM. This is for mobilisation & demobilization. Separate payment will be made for hire and operation charges of JCB, pick up van/tractor for shifting owner"s material to site, dewatering pump, DG sets, tent, watchman only. Other resources-manpower & machinery, equipment (except as above) required for completion of restoration of emergency site to be provided by the contractor & rate is inclusive in this item.
193Providing and operating items for attending the job at site, as per job requirement & at IOCL"s descretion.One day shall be of 8 hours duration of uninterrupted availability for continuous usage of the deployed service, i.e. for the first Eight hours or part thereof from the time of deployment - contractor shall be paid amount equal to one day. (i.e. 1 equipment day = 8 hrs of deployment and availability for contnuous usage).The working hours shall start from the time of deployment at site. This will be inclusive of Operational Charges (Fuel, Consumables, Operator etc whatsoever is required for intended operational at site); Job is to be carried out as per Tender Document and as per Instruction of EIC.Any additional deployment beyond Eight (8) hours, shall be paid extra as additional proporationate Day, and shall not be liable for any short of overtime / payment in any form. (i.e. for deployment of any sort of following services for a period of 10 hours in a day, same shall be paid as 1.25 Days (For items below)
194Tractor :Tractor with Fuel, operator for Transportation as per Job requirement (for owner supplied items)
195Dewatering Pump: providing and operating diesel engine driven (of capacity not less than 5 HP) water pump set including including Operator, fuel, hose length of suction / discharge side of atleast 30 meter for continuous functioning of the same at site
196Providing and operating atleast 25 KVA DG set for welding of leak clamp, weld plus end or for any other job in mainline including operator & fuel
197Portable DG Set: Providing Portable DG set (5 KVA) for 230 volt power supply for lighting / buffing / grinding / UT / X-ray etc. including mobilisation and demobilisation charges, Operator, fuel etc for continuous functioning of the same at site
198Halogen / focus set: Providing and temporary installation of Halogen / focus set with 30 mtr. Extension cabel including spare lamp 1000 watt for illumination of working area
199Additional Service Crew for Mechanical Miscllaneous Job as directed by EIC for Miscllaneous mechnical Job inclusive of 1 Pipe Linefitter & 2 Rigger along with Technician Tool boxes, consumbales etc. One day shall be equivalent to 24 hrs.
200Providing & operating JCB for earth work in excavation in both ordinary & Rocky soil for ROW cleaning, washout rectification/ installation ofanode ground bed, sacrificial anodes, cable trenches, pipelinetrenches, etc. including backfilling the same after completion of workin all respect and up to the satisfaction of Site Engineer / EIC & thecost includes all labour, materials complete as per direction of SiteEngineer/ EIC.
201Providing the air compressorof minimum 250 CFM capacity for other than the emergency works (leak / pilferage / burst) as per need basis in ROW works as per direction of EIC. One day shall be equivalent to 24 hrs.
202Providing tent of minimum size 10m x6 m, chair-50 nos, etc. One day shall be equivalent to 24 hrs.
203SITE GRDAING: Surface dressing (cleaning, levelling, stripping etc whatsoever to make approachable access for movement of machinaries at intended site) of the ground including removing vegetation and in - equalities not exsceeding 30 cm deep and siposal or fubbish, lead upto 50 m and lift upto 1.5 m - All kinds of soil surface, as per job requirement & directions of Engineer-in-charge.
204Earth work in excavation in all kinds of soil, both wet & dry condition (except hard rock requiring blasting, chiselling / pneumatic drilling) for foundation, substructures, trenches, sumps, pits etc. to the following depths including shoring, strutting, trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including bailing out of water (if any), stacking selected excavated earth for backfilling, filling available excavated earth in trenches, foundation, plinth etc. and/or disposing the excess earth outside IOCL premises to an unobjectionable area with all leads & lifts, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer/EIC.
205Excavation Up To 2.5 M - All kind of soil except hard rock (Measured from original ground level)
206Excavation B/w 2.5 M to 5 M - All kind of soil except hard rock
207Excavatiopn B/w 5 M & up to 50 M - All kind of soil except hard rock
208Hard Rock Removal - Excavation and backfilling in hard rock (requiring blasting chiselling / pneumatic drilling) dewatering if required, consolidating the trench bed, as per drawing and/or the direction of the EIC.
209Backfilling of Excavated Pit / Trecnch:Backfilling of the excavated pit/trench by Hydraulic means (JCB)/Manual Means, soil (excluding rock) removed during excavation of trench (stored within 50 m radius of the excavated trench).
210Manual excavation (restricted area without the use of JCB) in all type of soil including hard murrum for exposing existing pipeline , bottom clearance including keeping top layer of soil seperately, shoring, shuttering, stacking of soil, followed by backfilling of the trench . The contractor shall properly compact the backfilled earth & restore the RoW to original condition as per the direction of EIC/site engineer.
211REMOVAL OF PILFERER"S WELDING ARRANGEMENT When pipe, flange and valve assembly found welded over mainline pipe with or without patch welding: Removal of welded valve and pipe assembly with Grinding/ Cutting Machine. All resources required(machinery, manpower etc) for the cutting purpose will be provided by the contractor including charges of the cutter/ grinder complete in all respect as per direction of EIC/ Site Engineer/ Site Representative
212WELDING AND FITTING LEAK CLAMP/WELD PLUS END (max length upto 1000mm) : Fitting and Welding of leak clamp on pipe after depressurising and venting of Gas from the mainline, fitting, tightening and welding of leak repair clamp shall be carried out. Contractor shall give all required assistance for depresurising/ venting of Gas from the line, temporarily plugging leak point, assistance for closure of Mainline Valve in upstream & in downstrem of leak point , additional valve closure (if required). Only Leak clamp shall be provided by owner from nearest owner store yard. Removal of Old coating, cleanning of pipe surface, Fitting and Welding of leak clamp of length maximum upto 1000 mm, over mainline pipe with all tools tackles, i.e. Hydra, welding machine and qualified welder under the direction and supervision of site engineer/EIC. Fit-Up & Welding charges include fuel charges for the DG Machine, charges of the welder, fitter, helper, Grinder and supervisor , cost of welding rods, other accessories etc. complete in all respect. Welding of leak clamp includes welding circumferentialy and longitudinaly including welding of fasteners (nuts &bolts), Testing of welding integrity with Dye Penetration (DP) test complete in all respect as per direction of EIC/ Site Engineer/Site Representative.
21312"
21410"
2158"
2166"
2174"
218Sleeving of Mainline:- Type B: Fabrication, fitment and welding of full encirclement sleeves from owners supplied pipes over pitted/defect sections of the exposed pipeline including testing/inspection (DP/ Tell taletest), supply of all equipment, consumables, labor etc. required to complete the work in all respects as per the specifications and direction of the Site Engineer/EIC. Pipes will be supplied by the Owner from Owner"s Store yards and shall be transported to site at the Contractor"s risk & cost.
21912"
22010"
2218"
2226"
2234"
224Flood coating by R-95 Powercrete Liquid epoxy paint (Consisting Part A & Part B mixed in ratio as per manufacture recommendation over mainline pipe/ leak clamp/ Weld Plus End / sleeve etc. including surface preparation as per tender specification & application of liquid epoxy paint (Powercrete R-95) over finished surface. The cost includes all materials( liquid epoxy R-95) consumables, labour etc. The thickness of flood coating shall be 900-1000 micron.
225"COATING REFURBISHMENT: Cost of Coating & Wrapping refurbishment on diffrent size pipes section / welded Leak clamp / or adajacent to sleeving or on sleeve with owner supplied Cold applied tape as per specifications /directions specified in SCC in all respects. Work includes removal of old coating, pipe cleaning by sand blasting, primer application, coating application ( Inner & Outer). Payment shall be made depending upon pipeline size as per following separate pipeline sizes.
22612"
22710"
2288"
2296"
2304"
231Laying, Spreading of Morrum for Road Diversion: Laying, Spreading of Morrum by deployment of all required machinaries, tools, manpower, whatsoever for making Road Diversion as per job requirement and as per IOCL"s requirement.
232Road Cutting Cutting bituminous or water bound macadam road, stacking the material and making good the same as previous including supply of extra quantityof aggregate, moorum grit and bitumem etc. required, disposal of surplus earth if any/ complete as per the description of EIC. Job includes supply of all labour, equipments etc.
233Providing Nitrogen filled cylinder each of 7m3 capacity at 140-300 bar, as and when required basis including hose assembly (hose length 10 m minimum) fitted with flange 2 inch 300#/1 inch 300# on one end nd regulator with valveon another end However, cylinder shall be the property of the Contractor.
234Deployment of dedicated security guard/watch man at site for safety and security of pipeline during exigencies. The security guards shall be deputed at site on 24*7 basis till the completion of the work and closure of site. The security guard shall remain available at site to protect pipeline from any untoward activities. The unit of measurement "EA" means shift of 8 hours by one security guard.
235Hire Charges for Labour for emergency works: Note: Payment for Labour charges under this item will be made only for work carried out other than work mentioned in other SOR items of the tender and as per direction of Engineer-in-Charge. Unit per labour per day is shift of 08 hours.
236Transportation of pipe:-Taking delivery and transportation of Owner-supplied coated/bare pipe (upto length of 12m of OD 4"/6"/8"/10"/12") to the leak/pilferage/burst site in CGD Bihar from designated stockpile location at (IOCL GA of Bihar),loading and unloading, inspection of the coated/bare pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipe(s) are installed in permanent position.Carrying out repair of pipe & coating defects for defects occurring after "taking over" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling.Payment will be made per trip of trailor.
237Pipe Cold Cutting: After ventingof Gas from the piping, the Contractor shall arrange suitable cold cutting machine / Set up, associated tools & tackles, operators, consumables, compressor, hoses, Nitrogen etc. to cut pipe at mentioned location as per instructions of Engineer-in-Charge/ Site Engineer(the location shall be accessible for installation of the cold cutting machine before carrying out the job which is not covered in the scope of this item). The Contractor scope is including all required manpower, equipments, tools, tackles, materials, consumables etc. for completion of work in all respects as per instructions of Engineer-in-Charge/ Site Engineer. Note: Unit #EA# shall mean one full circumferential cut.
23812"
23910"
2408"
2416"
2424"
243Lowering & fitting of pipe- Shifting of pipe from designated place at site to work place, lowering of pipe in trench (Up to 05 meter depth) on sleepers/sand bags, cutting, grinding, fittings to match the mating edges of different thickness, alignment of pipe, fit-up, tieing-in and making pipe ready to hook-up/fitting of weld plus end with existing mainline on both side, including fixing ofhalf coupling etc, repair of damaged coating, making through the pipeline etc as per standard operating procedure and as per instructions of the Engineer-in-Charge to his satisfaction including supplying of all types of tools & tackles, lifting arrangements, equipments, Hydra all consumables & labour etc to complete the work in all respects in a workman like manner including area preparation for hot jobs, area cleaning after completion of work, flushing wherever required, cleaning of pipes externally off all foreign materials like weld beads, clamps fixtures etc. used in fabrication. Payment will be made for each pipe upto 12 meter.Rate is for 12 inch Pipe, For other dia rate to be prorated.
244Hook Up Joint -Edge preparation of pipe, welding using approved welding electrodes, Nitrogen purging, mud plugging, ultrasonic thickness of pipe, DP test, Fitting welding of TOR & tapping, 100% radiography including all consumables, equipments, welder & helpers, tools & tackles, testing/inspection etc to complete the work in all respect with all safety precautions as per the codes/specifications, drawing and direction of EIC/Site Engineer. TOR fittings & Foam pig shall be in scope of owner. Payment will be done on per joint welding basis.
24512"
24610"
2478"
2486"
2494"
250Electrical & T & I Services
251Operation and Maintenace of SCADA
252Blowing of Optical Fiber Cable : - All activities pertaining to blowing of optical fiber cable in self lubricated HDPE Telecom duct (after testing of drum at site),through CS/ HDPE conduits at crossing, cable sealing, padding, backfilling etc. using all materials required, etc. all complete as per specifications and drawing provided in the bid document & as per direction of consultant.
253Supply and installation of jointing pits, including sand, etc. all complete as per spec., drawing provided in the bid document and the direction of client / consultant.
254Jointing / splicing of optical fiber cable ( 24 Fibers ) including supply and installation of Joint Kit, joint markers (RF id Disk type), etc., testing all completed as per specifications &drawingprovided in the bid document and direction of consultant.
255Supply & installation of optical splice closer as per specifications & drawingprovided in the bid document and direction of client / consultant
256Supply & installation of Fiber termination cabinet as per specifications & drawingprovided in the bid document and direction of client / consultant
257Ultrasonic Thickness Testing at designated locations as informed by Engineer In Charge
258Noise Level Survey at designated locations as informed by Engineer In Charge
259"SUPPLY OF LAMPS Supply ofbelow given M/s Philips or equivalent make lamps for installation in lighting fittings / fixtures as per directions of EIC.LED tubelight 18W
260Electricalwiring(comprisingofsingleortwincorePVC wires upto 6 Sq mm and single earth wire upto 6 SWG) along with its connected accessories like junction boxes, surface conduits, battons, switch boards etc.
261SUPPLY & INSTLN. OF FUSEPARTS (KNIFE TYPE HRC FUSE LINK) 80 - 100 AMP Size 000
262"SUPPLYANDINSTALLATIONOFFLPJUNCTION BOXES"4-way Ex-e, WP Junction box with threded cover
263Supply & Installation of Pressure Gauge
264Supply & Installation of Temperature Gauge
265Supply laying & installation of GI Earthing strip 40X5 mm
266Supply & installation of FLP lights at CNG stations.
267TCP-Supply and installation of Mg Anode(7.6 Kg) :Supply & Installation of pre-packed Mg Anode (7.6 Kg) with one cable including 1Cx10 Sq.mm Unarmoured cable (with sufficent length) & encapsulation kit for cable connection termination of Anode tail cable in the TLP etc. complete in all respects as per direction of Engineer-In-Charge.
268TCP-Supply and installation of Zinc Anode(40 years design life/Min. 22Kg) for HT line crossings: Supply & Installation of pre-packed Zinc Anode (40 years design life / Min. 22 Kg) for HT Line crossing with one cable including 1Cx25 Sq.mm armoured cable (with sufficent length), encapsulation kit termination of Anode tail cable in the TLP etc.
269FCRI Calibration of Master Mass flow meter: FCRI calibration for flow meter which includes removing MFM,transporting to FCRI and reinstallation of MFM.Charges include all charges of labour ,transportation ,removing and reinstallation
270Quarterly Maintenance and calibration of Portable Multi Gas detectors, Fixed Hydro carbon detectors(4 No’s at CGS) ,Fire & Gas detection system at CGS.
271Maintenance and Calibration of Portable Multigas detectors. The charges includes cost of calibrating canisters,inspection, maintenence of the detectors and issuance of the calibration certificates.
272Maintenance and Calibration of Fixed Hydro Carbon Detectors, Fire & Gas detection including Breakdown Maintenance and Scheduled Maintenance as per tender specification and issuance of the calibration certificates.
273Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
2743.5x 50 mm2 A2XFY
2754x 6 mm2 2XWY
2764x 2.5 mm2 2XWY
277ELECTRICAL WORKS (ERECTION)
27825 sq mm green fexible copper wire(Approx 10mtrs) along with two nos Clamps harware etc shall be complete including mettalic cover box(suitable for outdoor) ,size 400X400X200 in all respect to earthing/ground of LCV at two points.
279Shock hazard charts complete with frame and glass
280First Aid Boxes
281Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware.
282Single Line Diagram complete in glass frame.(Size 600X800mm)
283INSULATING MATS - Supply & installation
284Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
285CABLE TRENCH:
286Excavationin unpaved areas of earth in worksites for conventional cable trenches for a depth upto 1.5 metres including shoring,strutting etc. (if necessary), backfilling the trench, job complete in all respects,including alllabourand materials complete asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
287Cable Laying - Layingofall typeof cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materialssuch as fixingclamps, screws, cable straps, tags, etc.as required (other than the supplyof the conduits, cables, pipes, cable racks, trays,poles,structures and panels) complete in all respect, including cost of alllabour, tools, consumable materials, etc. and cutting the cables in required lengths asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge:
288Power cables LT : OD upto 20 mm
289Power cables LT : OD above 20 mm and upto 40 mm
290Power cables LT : OD above 40 mm and upto 60 mm
291Power cables LT : OD above 60 mm
292SAND FILLING:
293Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge
294BRICK SOLING
295Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge. M2 764.39 854.50 18.08.2021 78 Electrical PJDCSW3009 COMPOSITE CABLE MARKER: Supply,
296CABLE MARKER:
297Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concrete grouting, backfilling, materials, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge.
298LT Cable joint (1.1 KV) - Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and tackles, consumables etc , asper drawings, specification and directionsofSite Engineer / Engineer-in-Charge:
299Power cables LT : OD upto 20 mm
300Power cables LT : OD above 20 mm and upto 40 mm
301Power cables LT : OD above 40 mm and upto 60 mm
302Power cables LT : OD above 60 mm
303EARTH ELECTRODES:
304Supplying, installation, testing of GI earthing electrode, including the supply and installationof the CI cover, charcoal /special backfill etc. and construction of chamber; complete asper drawings,specifications and directions of the Site Engineer, Including thecostof alllabour, tools, materials etc. completein all respects.
305EARTHING PLATE:
306Supply & Installation of G.I. earthing plate as per standard drawing outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels etc. and as per direction of EIC / Site engineer.
307EARTH STRIP / WIRE / ROPE / CABLE - Supply, installing and testing of earthing strip/wire/rope/cable forcompletely making the earthing grid system by supplying, laying theGI / Cu strip and makingall the necessaryweldingjoints, connecting to the earthing electrodesand existing earthinggridetc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect:
30850 mm X 6 mm G.I. earthing strip
30925mm x 4 mm copper flat
310SS TUBE & FITTING - SUPPLY, LAYING & TESTING
311Supply, Laying, testing and commissioning of SS tubes along with fittings as per Technical Specification, Typical P & ID for type of CNG station and scope of work, handling, lifting, transportation from stores toCNG stations.
312¾”OD X 0.095” min Wall thk.SS Tube (ReferTS Section III - A) - unit is running meter
313½”OD X 0.083” min Wall thk.SS Tube (ReferTS Section III - A) - unit is running meter
314Quick Connect Body & Stem
315QRC of 3/8" NPT , end connection:½" Tube OD, for stem & ½”NPT (F) for body MaterialSS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
316Nut
317¾ " OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
318½" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
319Supply , Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of workincluding handling, storage,lifting, transportation upto CNG stations.(Note:Total no.offerrule fittings may be considered as one jointing ferrule at every 5.0 m)
3201/4”OD X 0.035” min Wall thk.SS Tube (ReferTS Section III - A)
321ERECTION OF MECH. EQUIPMENT ( TRANSPORTATION REQUIRED)
322Handling (including lifting and transportation from Client"s store within city toCNG stations)and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.5 m above ground level.Contractor"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : Note: The quantities given above against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor.
323Cascade 4500/3000 L water capacity. Erection at + 4.0 M level (ReferTS Section III - B)
324Dispenser Erection at + Ground Level
325Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC Fire fighting Equipments : Sand Bucket with stand and canopy (4 Nos. on each stand)
326Conversion of DBS to Online/Mother Station
327Decommissioning of SS tubing, Dismentalling of SS tubing, providing connections with online compressor/cascade/dispenser as required including installation of fittings & relacement of damaged fittings (supply to be as per relevant SOR item) , Retesting of already laid tubings, installation of valves (supply as per relevant SOR), providing as build P&ID drawings, etc.completing all tubing/mechanical work to complete the conversion of DBS to Online station. Any fresh supply & laying of SS tubing to be paid separately as per relevant SOR item.
328Disconnecting / reconnecting all air piping/tubing , loading, transportation & unloading of compressor at designated locaation (within GA boundary),
329Disconnecting all electrical connections with booster compressor/panel/other equipment, relaying/testing of used cables if required, disconnection of earthing grid from compressor/panel/other equipment & recoonection with online compressor, repair of earth elecrodes etc. Any fresh supply and laying of cable/GI strip/earthing electrod to be paid as per relevant SOR
330ELECTRICAL WORKS (SUPPLY & installation)
331Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire with flame proof control gear
332Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
333STAINLESS STEEL INSCRIPTION PLATE:
334Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the cost of all labour, tools etc.
335Supply, fixing and connection of following Fuse base (HOLDERS) for HRC fuse link of M/HAVELL"S/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge.
336100 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
337125 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-00
338250 AMP ( Open Type Fuse Base) -FOR FUSE TYPE CD-1
339Supplying and fixing 5 amps. To 32 amps. Rating, 240/ 415 volts, 50Hz, 10KA "C" curve, miniature circuit breaker (suitable for motor and other inductive loads and conformingtoIS8828:1996,IEC60898:2002)of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Note: ISI marked MCBs of Havells / Loadster / Indo Kopp or equivalent make shall be used as per direction of Engineer- in-Charge.
340Single pole
341Single pole and neutral
342Double pole
343Triple pole
344Triple pole and netural
345Providing and fixing of metal clad, rewireable type switch fuse unit confirming to IS: 13497 (Part-I & II) of following ratings (Amp / Volt) including drilling holes on the board, connections, earthing the body etc. as required. Note: SFU of English Electric / L&T / Crompton / Havells /Standard /equivalent make shall be used as per direction of Engineer-in-Charge.
34663A / 415V, Tripple pole & neutral
347100A / 415V, Tripple pole & neutral
348200A / 415V, Tripple pole & neutral
34916A / 240V, Single pole & neutral
35032A / 240V, Single pole & neutral
351Supply of LED indication lamps for panel indications red/green/yellow/white etc. 240VAC as per direction ofEngineer-in-Charge.
352Supply of three phase digital ammeter, 0-1000A, 1/5 A,Class- 0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
353Supply of Three phase digital voltmeter, Class-0.5, 240VAC aux supply as per direction of Engineer-in-Charge.
354Providing salt and charcoal for pipe earth electrode as required.
35564 kg charcoal and 5 kg salt
356160 kg coke and 5 kg salt
357LT CABLE END TERMINATION FOR ARMOURED PVC INSULATED ALUMINIUM CABLE WITH SINGLE COMPRESSION BRASS GLANDING (EXCLUDING COST OF GLANDS & LUGS) :Providing end termination of power/control cable including cutting, stripping, fixing lugs, cable insulation, & glanding with single compression heavy duty brass cable gland wherever specified,fixingaluminiumlugsforpower cables and copper connectors for control cables, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete as per standard and direction of the Engineer-in-Charge.
3583 x 25 sqmm
3593 x 50 sqmm
3603 x 120 sqmm
3613 x 150 sqmm
362PROVIDING ALUMINIUM LUGS FOR MAINTENANCE
363Supply of aluminium tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes.
36425 sqmm
36550 sqmm
366120 sqmm
367150 sqmm
368DG on Hire basis
369Providing DG on monthly hire basis for CNG Stations including mobilizing and de-mobilizing charges, all required manpower, tools, tackles and complete in all respects as per directions by EIC.
37062.5 KVA for DBS CNG Stations
371125 KVA for OLS CNG Stations
372Diesel charges per litre
373SupplyandinstallationofshockhazardchartasperIE Rules1956(Clause-44)completewithframeandglass including necessary clamps, bolts, rawl plugs, etc. breachkingandmakinggoodthewallifrequired.All complete with labour and materials as per
374Supply and installation of "Caution Boards" at sub-stations asperIS2551/uptodateincludingsupplyofnecessary clamps, nuts, bolts and other hardware. All complete with labour and materials as per the direction of the Engineer- in-Charge
375"PROVIDE FIRST-AID BOXES Supply and fixing of First-Aid boxes as per IE Rules, 1956 Clause 43(2), including necessary clamps, bolts, rawl plugs, etc. breachking and making good the walls if required. All complete with labour and materials as per the direction of Engineer-in-Charg
376FIRE FIGHTING AND SAFETY Equipment Maintenance
377Taking delivery and refilling the extinguishers of various sizes/ capabilities including supply of dry chemical powder, CO2 gas etcupdating the data & identification tags, recording the status ofchecking in history register etc as per ISI standard and replacing thesame as directed by Engineer-in-Charge (The rates are inclusive of allTaxers). (The CO2 cylinder may to be taken out and delivered back within10 days after re-filling /repairing. However Fire extinguishers CO2 areto be supplied /Kept temporary in place of each fire extinguisher forwhich taking out for re-filling/ repairing is required).
378Dry Chemical Powder
3790.2 kg DCP Cartridge
3802 kg CO2 Cylinder
3813.2 kg CO2 Cylinder
3824.5 kg CO2 Cylinder
3836.8 kg CO2 Cylinder
38410 Kg DCP Cylinder
38575 Kg DCP Cylinder
386Supply and replacing the spares /assembles etc of the Fire Fighting equipments system for all sizes/ Capacities as per ISI standard and approved make with all labours, materials, carriages, inclusive of alltaxes etc. complete
387Rubber washer for Extinguisher
388CO2 Safety valves 155kgf/cm2
389CO2 Safety pins
390ISI marked Discharge Pipe with horn for 6.5 Kg and 6.8Kg CO2Exitinguishers.
391Rubber Gasket OF DCP Main Cap
392DCP main Cap (gun metal) CP
393DCP Plunger Pin with Spring
394DCP Plunger top
395Squeezing grip (Plastic) nozzle
396DCP cylinder discharge pipe of sufficient length for 10 Kg capacity Fire Extinguisher
397DCP cylinder discharge pipe of sufficient length for 75 Kg capacity Fire Extinguisher
398Hydrostatic testing, and inspection of high pressure CO2 extinguishers through PESO approved party andchargingupto required pressure(Refilling) includingtakingdelivery of the cylinder from the station and returning the same to station inclusive of all labour material, transportation and all the other incidental expenses). The cylinder is to be returned back to the station within 15 days from the date of receiving from the station. (For 2Kg /4.5 kg /6.8/ 45 kg CO2 cyl. and DCP cartridges)
399"Supply and painting with two coats synthetic enamel paint (Asian/Burger) fire paint including scrapping, cleaning, applying onecoat of red oxide primer cost of all labours, materials, carriage,taxes, letter/number writing, identification marks etc. complete in allrespect."
400Spray/Brush painting of fire bucket stand with its bucket (4-6 Bucket)including letter/number writing.
401Spray painiting of Fire extinguishers of all sizes includingletter/number writing.
402Fire Siren including letter/ number writing.
403Air filling in cylinders of Breathing Apparatus inclusive of all taxes with transportation
404Hydraulic testing of CO2 Cylinders inclusive of all taxes ( 2 to 4.5Kg/Cm2)
405Hydraulic testing of CO2 Cylinders inclusive of all taxes ( 6.8Kg/Cm2)
406Hydraulic testing of DCP Cylinders of all sizes inclusive of all taxes
407Hydraulic testing of Breathing Appratus Set
408Supply and fixing of wind socks on the position including all labour,tools and tackels as per direction of Engineer-in-Charge inclusive of all taxes.
409CIVIL ARC WORKS
410PAINTING WORKS
411Scrapping of moss,blister etc.thoroughly from surface of walls with scrapper/ wire brush complete in all respects as per specifications and directions of Engineer-in-Charge/ Site Engineer.
412Removing loose scales,blisters etc from old painted steel or wooden surface by scrapping with wire brush thoroughly and smoothening the surface to make it suit- able for receiving fresh coat of paint complete with all labour and materials as per specifications
413Painting any shade as directed with best quality Synthetic Enamel /Aluminium paints of ASIAN, BERGER or other equivalent approved make and brand on steel/timber/plastic/metal including smoothening the surface by sand papering etc complete with all labour and materials complete in all respects as directed
414(a) Two coats including priming coat
415EARTH WORK
416Surface dressing and grading of the ground including removing vegetation and Leveling the undulations up to the depth of 15 cms (cutting andfilling up to 15cm), removing the pebbles, stones, brick bats, woodenbattens/logs and tree leaves and including disposal at no extra costoutside the IOCL premises.
417HORTICULTURE WORKS
418Maintenance of lawn grass including watering at least thrice in a month,cutting, trimming, removing grass, vegetation including labour and all materials, tools and tackles etc. complete as directed by Engineer in Charge.
419SANITARY & TOILET FITTINGS WORKS
420Repairing the old urinal including removing the old one and making good same including all labour and materials complete.
421Repairing the bibcock, stop cock, pillar cocks,flush cocks,push cock,ball cock etc by replacing necessary washer valve seat gland packing andany other working part etc as required complete.
422Cleaning the tiles, lavatory flooring, urinals by using any of the following materials with required proportion including all labour and materials complete.
423Vim powder/ cleaning powder
424ISI grade black phynyle/ white
425Acid/ Nepthas ball
426Coir brushes/wire brushes
427Finit
428Washing and cleaning complete toilet block and maintaining the same in good hygienic condition by supplying and providing air fresheners such as Odonil napthaline balls, Phenole, vim powder etc. using good approved quality of washing materials including cleaning of all accessories and phenol within the bathroom.The rate is on per day basis.
429Having two/ three urinals, one/ two WC,two/ three Wash basins,including floor and floor traps etc.
430Having one/two urinals, one WC, one/ two Wash basins, including floor and floor traps etc.
431Mopping of floors of offices ,toilets, control rooms, electrical substations etc. with soap solution or ordinary water with wet clothafter sweeping the floor with phooll broom removing cob-webs with all tools ,tackles, labour & materials etc. complete as per directions ofengineer -in-charge.
432Cleaning of overhead water tanks byremoving sludge, moss by scrapping & disposing them out at the dumping place within the lead of 500 m.Tank to be bleached with chlorinated water/ bleaching powder in proportion to disinfect properly with all labour,material complete and as per direction.(Litre= per lit of tank capacity)
433Repairing damaged plastered wall or flooring by rendering necessary patch work including removing the existing damaged plaster or IPS,raking out the joints of brick work, cleaning the surface and filling the depressions with reinforcement mortar & neat cement punning,levelling the surface curing etc. complete with all labour, materials &scaffolding etc.including removing the debris as directed.
434Repairing and servicing the existing aluminium door or window by realigning the door, repairing, servicing, oiling, greasing etc complete and making it in perfect working condition with all labour and materialsetc, complete up to any size.
435Providing & painting with acrylic distemper of make ASIAN,BERGERor NEROLAC or equivalent two coats for the old surfaces after scrapping andcleaning the existing surface and applying a coat of primer and one coat of putty where required etc. including necessary scraping ,scaffolding etc. complete.
436Surface preparation ,supplying and painting two or more coats of weather proof acrylic smooth exterior emulsion paint of make ASIAN(APEX) , BERGER or NEROLAC or equivalent on exterior wallsover one coat of cement primer and wall putty where required as per specifications and of approved color and make including all scraping ,removing unwanted material and scaffolding all complete.
437Painting lines,dashes,arrows,letters etc. on roads,field and like up to 10 cm in width in two coats with road marking paint,brushing including cleaning the surface of all dirt,dust and other foreign matter.
438Letter writing with Synthetic Enamel Paint of approved brandand manufacture Note : Unit of measurement is considered EACH which is equal to per cm height per letter.
439Supplying and spreading insecticides as per the direction.
440Roger( litre= 100ml)
441Malathon( litre= 100ml)
442Novan( litre= 100ml)
443BHC(50%)
444BHC(10%)
445Andrex ( litre= 100ml)
446PLAIN CONCRETE WORKS Providing & laying Plain Cement Concrete (PCC of different grades) infoundation, floor or at other places by using crushed stone aggregatesas directed where necessary and curing with water excluding cost ofcentering and shuttering.
4471:1.5:3 [1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources]
4481:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
449Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
4501:1.5:3 (1 cement:2 sand: 4 stone aggregate 20 mm nom.) in foundation and plinth excluding form work and the cost of Reinforcement bars.
4511:2:4 (1 cement:2 sand: 4 stone aggregate 20 mm nom.) in foundation and plinth excluding form work and the cost reinforcement bars.
452REINFORCED CEMENT CONCRETE: CEMENT CONCRETE TMT Bars (Fe-500D grade or more) Thermo-Mechanically Treated bars of grade Fe-500 D or more
453Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :
454In 1:4 cement sand mortar (1 cement : 4 medium coarse sand )
455Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
456In 1:4 cement sand mortar (1 cement : 4 medium coarse sand )
457FLOORING
458Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks :1:4 (1 cement : 4 coarse sand)
459FINISHING Providing 15 mm thick cement plaster on walls or floor in cement mortar including raking out the joints over the brick work, stone masonry orconcrete surface in one or more coat as directed,curing, scaffolding,finishing smooth with cement punning etc all complete
460C.M. 1:4 ( 1 cement : 4 sand)
461Pipe Support & Structures Supply, fabrication and erection of all types of pipe supports of MS material like clamps, saddle, guide stops, cradles, turn buckles, anchors, T-posts; stockade / trestle and pipe bridge for overhead piping; frames for canopy, approach ladders and platforms,crossover, cable tray supports etc. including painting suitable for highly corrosive area as per specification labor and supervision & complete work as per specifications and instruction of Engineer in charge (Bolts, nuts, washers, PVC coated U - clamps etc. for supporting shall be supplied by the contractor within the rates quoted. These items will not be measured and paid separately) this work is to be complete in all respect as per scope of work.
462Surface Excavation Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.
463Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : In all kinds of soilIn all kinds of soil
464Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, upto specified depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil, all work up to any lead & lift as directed by the Engineer-in-Charge: Trench depth upto 1.5m: Trench depth upto 1.5m :Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
465Filling local earth- Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to all leads, also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
466Supplying and filling in plinth with sand IN TRENCHES UNDER floors, including watering, ramming, consolidating and dressing complete.
467Centering & Shuttering: Centering and shuttering including strutting, propping etc. and removal of formwork for :
468Foundations, footings, bases for columnsFoundations, footings, bases for columns
469Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
470Columns, piers, abutments, etc.Columns, piers, abutments, pillars, posts and struts
471Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer’s recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).
472G.I. Barbed Wire Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 Kg/100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. [Notes: (1) Cost of posts, struts, earth work and concrete work to be paid for separately. (2) Payment to be made per metre cost of total length of barbed wire used].
473Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the directions of the Engineer-in-Charge :
474PVC coated GI wire (4mm dia.)Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade.
475Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the directions of the Engineer-in-Charge.
476Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of high carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equivalent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 microns. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regular intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed condition should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
477Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of first quality conforming to IS:15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including pointing the joints with white cement and matching pigments etc., complete.
478Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour :
479One coat
480Two coats
481Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
482Textured exterior paint: Finishing walls with textured exterior paint of required shade :
483Old work (Two or more coats)Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm.
484Old work (One or more coats)Old work (One or more coats) applied @ 1.82 ltr/10 sqm.
485Acrylic Smooth exterior paint: Finishing walls with Acrylic Smooth exterior paint of required shade :
486Old work (Two or more coats)Old work (Two or more coat applied @ 1.67 ltr/10 sqm) on existing cement paint surface.
487Old work (One or more coats)Old work (One or more coat applied @ 0.90 ltr/10 sqm)
488Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] :
489Nominal concrete 1:3:6 or richer mixNominal concrete 1:3:6 or richer mix (including equivalent design mix)
490Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]
491Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work as per direction of the Engineer-in-Charge. [Notes: (1) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge. (2) Payment shall be made on the cross sectional area of R.C.C. or R.B. work]
492Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per directions of the Engineer-in-Charge.
493Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) Old kerb stones shall be supplied by the department free of cost.]
494Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per directions of the Engineer-in-Charge.
495Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the directions of the Engineer-in-Charge. [Note: Old CC paver blocks shall be supplied by the department free of cost].
496Printing of safety posters as directed by EIC.(Monthly safety theme,MSDS,Safety Policy,BTCP,ERDMP,Safety week themes,special posters for audits etc).
497Sandwich fittings boards made of Acrylic sheets
498Preparation of Display Board of following size including stainless steel angles, Pipes etc. alongwith pasting of flex as per direction of EIC/site Engineer :- Size:- 8 feet x 4 feet
499Preparation of Display Board of following size including stainless steel angles, Pipes etc. alongwith pasting of flex as per direction of EIC/site Engineer :- Size:- 6 feet x 4 feet
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail