}

Tender For Construction Of Barimukh Meat Market Shed At Barimukh Chowk Under Baksa District, Baksa-Assam

Bodoland Territorial Council has published Tender For Construction Of Barimukh Meat Market Shed At Barimukh Chowk Under Baksa District. Submission Date for this Tender is 12-02-2024. Paver Blocking Tenders in Baksa Assam. Bidders can get complete Tender details and download the document.




Tender Notice

41941935
Tender For Construction Of Barimukh Meat Market Shed At Barimukh Chowk Under Baksa District
Open Tender
Indian
Assam
Baksa
12-02-2024

Tender Details

Construction Of Barimukh Meat Market Shed At Barimukh Chowk Under Baksa District , A. Market Shed ( 2 Nos ) , 2. Earth Work , 2.8 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil. , 2.25 ( A ) :Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , 2.28 :Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. 2.28.1 All Kinds Of Soil , 4.0 Concrete Works , 4.1 : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 4.1.8, 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , 5. Shuttering Works , 5.9 : Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : , 5.9.1 : Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , 5.9.5 :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.6:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.22: Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 5.22.6Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , 5.22.A: Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 5.22.6Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , 5.33: Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. , 5.33.2: All Works Above Plinth Level Upto Floor V Level , 6.0 Masonary Work , 6.1: Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: 6.1.2Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , 10.0 Steel Works , 10.2 :Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , 12.0 Roofing , 12.45: Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dashfastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flangeof Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Requiredlength With Nuts & Bolts Of Required Size And Other End Of Anglehanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Runningat The Spacing Of 1200 Mm Centre To Centre, To Which The Ceilingsection 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flangesof 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channelwith Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I.Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mmthick 27 Mm High Having Flanges Of 20 Mm And 30 Mmlong, Theperimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugsat 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufacturers Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : , 13.0 Finishing , 13.2: 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 13.2.2 1:6 ( 1 Cement: 6 Fine Sand ) , 13.48A: Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives. 13.48A.1 New Work ( Two Or More Coats Applied @ 1.43 Litre / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm. , 13.48: Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications : , 13.48.2: Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr / 10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr / 10 Sqm Of Approved Brand And Manufacture , B. Parking , 2.0 Earthwork , 2.8 : Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. 2.8.1 All Kinds Of Soil. , 2.25 ( A ) : Excavating, Supplying And Filling Of Local Earth ( Including Royalty ) By Mechanical Transport Upto A Lead Of 5Km Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm In Trenches, Plinth, Sides Of Foundation Etc. Complete. , 4.0 Concrete Works , 4.1 :Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 4.1.8, 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , 5.0 Shuttering Works , 5.9:Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : , 5.9.1:Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , 5.9.5: Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , 5.9.6:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.22:Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. 5.22.6Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , 5.33:Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. , 5.33.1:All Works Upto Plinth Level 5.33.1.1 Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg / Cum , 6.0 Masonary Work , 6.1:Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: 6.1.2 Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , 13.0 Finishing , 13.2: 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 13.2.11:4 ( 1 Cement: 4 Fine Sand ) , 13.48A Finishing Walls With 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm / Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade ( Company Depot Tinted ) With Silicon Additives. 13.48A.1 New Work ( Two Or More Coats Applied @ 1.43 Litre / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre / 10 Sqm. , 16.91: Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge. , 19.91.2: 80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern , C. Water Supply , 23.1:Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90 Metre Depth Below Ground Level , 23.1.1:All Types Of Soil , 23.1.1 : 300 Mm Dia , 23.4:Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Hire & Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge. , 23.4.1: 100 Mm Nominal Size Dia , 23.6 :Supplying, Filling, Spreading & Leveling Gravels Of Size Range 5 Mm To 10 Mm, In The Recharge Pit, Over The Existing Layer Of Boulders, In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge , 18.46:Providing And Fixing G.I. Union In G.I. Pipe Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) , 18.46.8:80 Mm Nominal Bore , 18.12:Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc. , 1280 Mm Dia Nominal Bore , 18.12.6:50Mm Nominal Bore , 18.12.15 Mm Dia Nominal Bore , 25Mm Nominal Bore , Making Connection Of Gi Distribution Branch With Gi Main Of Following Sizes By Providing & Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete. , 50-80 Mm Nominal Bore , Providing And Fixing Gun Metal Gate Valve With Ci Wheel Ofapproved Quality ( Screwed End ) . , 40Mm Nominal Bore , 50Mm Nominal Bore , Providing And Fixing Gun Metal Non-Return Valve Ofapproved Quality ( Screwed End ) . , 50Mm Nominal Bore , Horizontal , Development Of Tube Well In Accordance With Is : 2800 ( Part I ) And Is: 11189, To Establish Maximum Rate Of Usable Water Yield Without Sand Content ( Beyond Permissible Limit ) , With Required Capacity Air Compressor, Running The Compressor For Required Time Till Well Is Fully Developed, Measuring Yield Of Well By V Notch Method Or Any Other Approved Method, Measuring Static Level & Draw Down Etc. By Step Draw Down Method, Collecting Water Samples & Getting Tested In Approved Laboratory, I / C Disinfection Of Tubewell, All Complete, Including Hire & Labour Charges Of Air Compressor, Tools & Accessories Etc., All As Per Requirement And Direction Of Engineer-In-Charge , Providing And Fixing Suitable Size Threaded Mild Steel Cap Or Spotwelded Plate To The Top Of Bore Well Housing / Casing Pipe, Removableas Per Requirement, All Complete For Borewell Of , 100 Mm Dia , Providing And Fixing M.S. Clamp Of Required Dia To The Top Of Casing / Housing Pipe Of Tubewell As Per Is: 2800 ( Part I ) , Including Necessary Bolts & Nuts Of Required Size Complete. , 100 Mm Clamp , Providing And Placing On Terrace ( At All Floor Levels ) Polythene Water Storage Tank Of Approved Brand And Manufacture With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet , Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.

Key Value

Document Fees
INR 1500 /-
EMD
INR 95500.0 /-
Tender Value
INR 47.77 Lakhs /-

BOQ Items

Name of Work: Construction of Barimukh Meat Market Shed at Barimukh Chowk under Baksa District.
Sl. No. Item Description
1A. MARKET SHED (2 Nos)
22. EARTH WORK
32.8 : Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
42.25(a) :Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
52.28 :Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. 2.28.1 All kinds of soil
64.0 CONCRETE WORKS
74.1 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8,1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
85. SHUTTERING WORKS
95.9 : Centering and shuttering including strutting, propping etc. and removal of form for :
105.9.1 : Foundations, footings, bases of columns, etc. for mass concrete
115.9.5 :Lintels, beams, plinth beams, girders, bressumers and cantilevers
125.9.6:Columns, Pillars, Piers, Abutments, Posts and Struts
135.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6Thermo-Mechanically Treated bars of grade Fe-500D or more.
145.22.A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6Thermo-Mechanically Treated bars of grade Fe-500D or more.
155.33: Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.
165.33.2: All works above plinth level upto floor V level
176.0 MASONARY WORK
186.1: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2Cement mortar 1:6 (1 cement : 6 coarse sand)
1910.0 STEEL WORKS
2010.2 :Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2112.0 ROOFING
2212.45: Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dashfastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flangeof cleat fixed to the angle hangers of 25x10x0.50 mm of requiredlength with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mm runningat the spacing of 1200 mm centre to centre, to which the ceilingsection 0.5 mm thick bottom wedge of 80 mm with tapered flangesof 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm high having flanges of 20 mm and 30 mmlong, theperimeter of ceiling fixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
2313.0 FINISHING
2413.2: 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.2 1:6 (1 cement: 6 fine sand)
2513.48A: Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
2613.48: Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
2713.48.2: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
28B. PARKING
292.0 EARTHWORK
302.8 : Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
312.25(a) : Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
324.0 CONCRETE WORKS
334.1 :Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.8,1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
345.0 SHUTTERING WORKS
355.9:Centering and shuttering including strutting, propping etc. and removal of form for :Centering and shuttering including strutting, propping etc. and removal of form for :
365.9.1:Foundations, footings, bases of columns, etc. for mass concrete
375.9.5: Lintels, beams, plinth beams, girders, bressumers and cantilevers
385.9.6:Columns, Pillars, Piers, Abutments, Posts and Struts
395.22:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6Thermo-Mechanically Treated bars of grade Fe-500D or more.
405.33:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
415.33.1:All works upto plinth level 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum
426.0 MASONARY WORK
436.1:Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)
4413.0 FINISHING
4513.2: 15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.11:4 (1 cement: 4 fine sand)
4613.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
4716.91: Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
4819.91.2: 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern
49C. WATER SUPPLY
5023.1:Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level
5123.1.1:All types of soil
5223.1.1 : 300 mm dia
5323.4:Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
5423.4.1: 100 mm nominal size dia
5523.6 :Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
5618.46:Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)
5718.46.8:80 mm nominal bore
5818.12:Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
591280 mm dia nominal bore
6018.12.6:50mm nominal bore
6118.12.15 mm dia nominal bore
6225mm nominal bore
63Making connection of GI distribution branch with GI main of following sizes by providing & fixing tee, including cutting and threading the pipe etc. complete.
6450-80 mm nominal bore
65Providing and fixing gun metal gate valve with CI wheel ofapproved quality (screwed end).
6640mm nominal bore
6750mm nominal bore
68Providing and fixing gun metal non-return valve ofapproved quality (screwed end).
6950mm nominal bore
70Horizontal
71Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge
72Providing and fixing suitable size threaded mild steel cap or spotwelded plate to the top of bore well housing/ casing pipe, removableas per requirement, all complete for borewell of
73100 mm dia
74Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
75100 mm clamp
76Providing and placing on terrace (at all floor levels) polythene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet , outlet and overflow pipes but without fittings and the base support for tank.
77Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail