Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #41937396

Tender For Integrated Comprehensive Maintenance Of Smq Block No- P-2, P-11 And P-26 At Af Station Tughalakabad Under Ge (Af) Tughlakabad.

Issued by Statutory Bodies & Commissions/Committees · tughlakabad, Delhi
Tender Value
80 Lakhs
Estimated cost
Bid Submission
05 Mar 2024
0 days left
EMD
1.45 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tughlakabad → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Integrated Comprehensive Maintenance Of Smq Block No- P-2, P-11 And P-26 At Af Station Tughalakabad Under Ge (Af) Tughlakabad.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Feb-2024 Corrigendum-1 BOQ 27-Feb-2024
2 27-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-Mar-2024

BOQ

Name of Work: Integrated comprehensive maintenance of SMQ\"s block No- P-2, P-11 & P-26 at AF Station Tughalakabad under GE (AF) Tughlakabad.
Sl. No. Item Description
1Sch \"A\" Part-I (B/R Portion)
2Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articlescomplete all as specified and directed .
3M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius built in CM 1:6complete all as specified and directed .
4M&L for gunniting to RCC works in column,beams, slabs, chajja, facia, landing, balconies and similar wks etc by removing/ dismantling of RCC(loose concrete) including plasterand cutting of steel barincluding cleaning of surfaces with wire brushes and applying epoxy, paint anti corrosive coating of minimum 40-50 microns thick with sikatop Armatec 108 or Colusal VL of MC Bauchemie to rusted steel reinforcement after removing cleaning all rust and supply and fixing with sufficient fasteners/concrete nails/welding at regular intervals welded steel wire mesh 75mm x75mm with 4mm dia steel wire as faces/drops and applying epoxy based or other equivalent suitable bonding against treatment to be carried out on old concrete surface with Sikadur 32 of Sikka.Nito bond EP of fosroc or equivalent (as per manufacturers instruction) to bond old and new concrete mixing @ 2% by weight of cement polycrete and providing gunniting with a minimum pressure of 2 to 2.5 Kg sqcm with varying thickness from 25mm to 100mm as per requirement at site gunniting in cement mortar (1:2) (one part of cement and two part of ghaghar sand) and plastering in cm 1:4 (20 to 25mm) to a uniform surface included in quoted rate, wherever required at any height, location and position complete all as specified and directed . Note:-(i)After placing the additional reinforcement all concrete surface shall be thoroughly scrubbing with.(ii)Additional reinforced TMT barswere incorporated in work however min 20mm thick cement plaster in 1:4 and necessary connected wks related to gunniting to be included in quoted rate.(iii)Work to be carried out as in patches as directed by Engr-in-charge.(iv)Rate for steel scaffolding and formwork wherever required and as directed to be included in quoted rate.(v) All demolished material removed from MOD land completely.(vi)The works will be executed in different buildings and at scattered locations.
5M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends, welding wherever required and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
6M&L TMT steel bars 6mm to 8mm dia and over cut to length bent shape required, including cranking bending, binding with mild steel wire (annealed), welding wherever required not less than 0.9mm dia quality conforming to relevant IScomplete all as specified and directed .
7Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner).Make: Sika, Fosroc or concressive 1450 of BASF complete all as specified and directed. Note:-(i)Adequate lap length shall be provided as per IS-456-2000.(ii)Reinforced TMT bars where incorporated in work will be paid under item no 2&3. (iii)The work shall be carried out upto four storied building with scaffolding and in patches as directed by Engr-in-charge. (iv) Rate for scaffolding and formwork wherever required and as directed to be included in quoted rate.(v) The works will be executed in different buildings and at scattered locations.
8M&L for providing and applying corrosion resistance non-shrink free flow, cementitious one component Micro-concrete with average thickness 75mm having compressive strength (BS 4551-80-60) 50 MPA at 28 days, Tensile strength (ASTM C 348)-2.0 N/mm2 @ 28 days, Flexural strength (ASTM C 348)-9 epoxy bonding agent TM bond EP thermax having mix density of 1.45 to 1.5 kg/ltr, compressive strength (BS-6319 PT 3)-25 Mpa at 7 days bond strength (ASTM C 881)- 11 N/mm2 at 7 days, having an over lay time of 3 hrs at 30°C pouring of micro concrete into the formwork using suitable arrangement or if required using pumping device for and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate etc including necessary formwork at any height, location and position all tools and tackles as per accepting officer, complete all as specified and directed.Make : BS-66 Mucisof Thermax/Webac Chemicals/Chemco System or as approved by Accepting Officer. Note : - (i)Work to be carried out as in patches as directed by Engr-in-charge.(ii) Rate for scaffolding and formwork wherever required and as directed to be included in quoted rate.(iii) The works will be executed in different buildings and at scattered locations.
9Taking downloose cement plaster on brick, stone walls and concrete surfaces(except above mention in description 1 area) of any description/position etc including racking out joints, hacking for keys scrubbing down with water etc complete all as specified and directed.
10M&L 5mm thick rendering in CM 1:3 on concrete surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed.
11M & Ltwo coats of cement base paint over a coat of primer on newly plastered surface of walls to match the exixting colour incl preparation the surface complete all as specified (External)
12M&L preparing newly surfaces of ceilings and applying three coat of white wash onnew surfaceall as specified.
13M&L preparing new surfaces of walls and applying two coat of Oil bound distemper onnew surface over a coat of primer et complete all as specified.
14M&L for 10 mm thick cement plaster with readymix plaster (as per manufaturer\"s instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed.Note:-1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE)2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer.3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster by manufacturer or their authorised dealer while claiming RAR/ Final Bill.
15M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer\"s instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed. Note:-1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE)2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer.3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster by manufacturer or their authorised dealer while claiming RAR/ Final Bill.
16Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified incl removal of debriscomplete all as specified and directed . .
17M&L for Cement concrete type C1, 1:3:6 (using 20 mm gradedstone aggregate) as in sunken floor incl finishing the surface even and smooth w/o using extra cement all as specified and directed.
18M&L for cement concrete type F2 (1:7:12) using 40mm graded aggregate as in sunken portion of toiletscomplete all as specified and directed .
19M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in CM 1:4 mixed with water proofing compound @ 3% by weight of cement for fixing of nahani trap or floor trap,P TRAP etc in sunken position complete allas specified and direced.
20M&L for rendering 15mm thick in cement mortar 1:4 with water proofing compound3% by wt of cement, finished even and smooth withot using extra cement in sunken portion complete all as specified. Note:- WPC shall be measured and paid separately
21Supply only integral water proofing compoundcomplete all as specified and directed . .
22Applying evenly a tack coat of industiral bitumen 85/25 at the rate of 1.20 Kg/Sqm including cleaning of surfaces over sunken portion including depth od sunken areacomplete all as specified and directed .
23M&L for leakage/seepage proof coating consisting of preparing the surface of roofs,exterior walls, parapet ,sunken area ,chajjas etc. with wire brush to remove all loose dirt, oil, grease etc. and filling cracks above 5mm thickness with Dr Fixit Pedilite URP or with plaster seal of STP Ltd and crack less than 5mm with Dr Fixit Crack X powder or with plaster seal of STP Ltd and applying Dr Fixit primeseal primer or STP Ltd (and allow today for 8hrs under touch dry condition and subsequently two coats of water proof decorative elastomeric coating system of Dr Fixit Raincoat with DFT 100 microns or shalicry 215 of STP (The surface after painting one coat shall be allowed to dry at least 6 hours before next coat)etc. complete all as per manufacture instruction and all as specified and directed.
24Demolition of cement concrete reinforced in any position incl cut of bars as required complete all as spd and directed
25M&L for reinforced cement concrete 1:2:4 type B1 as in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
26M&L for reinforced cement concrete 1:2:4 type B1 as in columns, pillars, piers, posts and struts and the like complete all as specified and directed.
27M&Lfor rough finished surfacesofFormwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc chajja shelvesincl supports etc complete all as specified & directed.
28Dismantling floor hearth or wall tiling including cement mortar bedding and removing debries off the premisiscomplete all as specified and directed . .
29S&Fof glazed ceramic coloured tiles 7mm thick 450 x 300mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade. Etc including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
30M&L glazed ceramic colour (non skid) tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm ( 300 mmx300mm x 7mm thick) set and jointed in neat cement slurry and pointed in colour cement as in floorover and including 15 mm thick screed bed or bedding layer ofcement mortar 1:6 complete all as specified and as directed.
31S&F glazed ceramic (non skid) joint free edge cut coloured tiles7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (400mmx400mmx8mm thick ) set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected.
32Description same as per above item but, as on dado/ skirting incl 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
33S&F non skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floors, including 15 mm thick screed in CM 1:6 complete all as specified.
34S&F non skid ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm on vertical surfaces such as skirtings including 10 mm thick rendering in CM (1:4)etc complete all as specified.
35Dismantling of stone slab of roof suspended floors any thickness jointed in cement mortarcomplete all as specified and directed .
36M&L for 20mm thick granite (of any type)work (table rubbed and polished ) in steps, jambs, pillars, window cills, cooking plateforms and like over 15mm thick screed bed in CM 1:6including pointing in white cement 1:2using marble dust with admixture of pigment to match with shade of graniteincluding 15mm thick screed bed or bedding layer in CM (1:4)etccomplete all as specified and directed.
37Rounding to the edge of stone slabs on edge such as cooking platform etc complete all as specified and directed .
38Taking up or down steel water tubing and connections including cleaning for refixing or removal to store of 20 mm borecomplete all as specified and directed .
39Taking up or down 15mm bore GI tubing and connections, including cleaning for re-fixing or removal to store, complete all as specified and directed.
40S&F GI water tubing medium grade 20mm bore including allnecessary fittings and fixed complete to walls and ceiling or laid in floorscomplete all as specified and directed .
41S&F GI water tubing medium grade 15mm bore including all necessary fittingsand fixed complete to walls and ceiling or laid in floorscomplete all as specified and directed .
42Refixing only GI water tubing of bore 20mm with all necessary fittings and fixd complete to walls and ceiling or laid in floorscomplete all as specified and directed .
43Refixing only GI water tubing of bore 15mm with all necessary fittings and fixd complete to walls and ceiling or laid in floorscomplete all as specified and directed .
44S&F in repair PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints, fixed to wallscomplete all as specified and directed .
45S&F in repair PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints, fixed to wallscomplete all as specified and directed .
46S&F PVC (SWR) bends (TEE,Elbow & socket) any radius 110mm bore complete all as specified and directed .
47S&F PVC (SWR) bends (TEE,Elbow & socket)any radius 75mm bore complete all as specified and directed .
48S & F PVC connection 15mm size & length 450mm long with PTMT nuts of length 450mm complete all as specified and directed .
49S & F PVC waste pipe of 32 mm dia PVC socket for WHB/sink complete all as specified and directed
50S & F in repairs of vitreous China squatting pan of Orissa pattern of approved make of size 580 mm X 440 X 260 mm white with integral foot rests (excluding flushing cistern and flush pipe) includingP trap connection to trap and to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floor complete all as specified and directed.
51S & F in repair of vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti syphonage pipe etc complete and making good to floor complete all as specified and as directed.
52S&F Health Faucet with 1.5 mtr long SS tube and hook etc complete all as specified and as directed.
53S & F in repair PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle etccomplete all as specified & directed.
54Fixing only in repair ofPVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle etccomplete all as specified & directed.
55S&F in repairvitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed.
56Fixing only in repairsvitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed on and including cast iron cantilever bracket 32 mm dia brass waste coupling and including fixing of tap, waste fitting and union complete all as specified and as directed.
57Disconnecting existing water tanks,setting a side (or lowering if required) for repairs, cleaning etc and hosting, reconnecting and re-fixing in same or other position of exc 500 ltr but n\"exc 1000 ltr for roof treatment portion.
58Disconnecting existing water tanks,setting a side (or lowering if required) for repairs, cleaning etc and hosting, reconnecting and re-fixing in same or other position of exc 250 ltr but n\"exc 500 ltr for roof treatment portion complete all as specified and directed . .
59Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capacity and removing from site to store yard complete all as specified and directed.
60Dismantling of existing water tank (PVC/RCC/AC) exc 250 ltr but n exc 500 ltr capacity and removing from site to store yard complete all as specified and directed.
61S & F rotational moulded polyethlene water storage tank (cylindrical vertical with closed top) hoised and fixed in position of capacity 500 Ltr complete all as specified and directed .
62S & F rotational moulded polyethlene water storage tank (cylindrical vertical with closed top) hoised and fixed in position of capacity 1000 Ltr complete all as specified and directed .
63S & F in repairs 20mm ball PTMT valve high pressure with polyethlene float valvefly nut complete screwed with iron pipe or brass ferrule and fixed in repair complete all as specified and directed .
64S & F in repair sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastesincluding bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm
65Cleaning of roof slab/chajja with sweeping with brooms, removing complete all as specified and directed.
66Taking down old existing roof treatment of any type including mud phuska and removing from MoD Land complete all as specified and directed.
67Brushing neat cement slurry with 3kg of cement per Sqm complete all as specified and directed.
68M&L for PCC average 40 mm thick in proportion (1:2:4) type B-O using 12.5 mm graded stone aggregate as in padding finishing surface of concrete topping in floors, roofs, finished even and smooth without using extra cement complete all as specified and directed.
69M&L for 10mm thick plastering in CM (1:3) on green concrete roof surfaces Sqm with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed.Note - WPC shall be measured and paid separately.
70M&L for preparing new surfaces and applyingone coat of primer andtwo coat of Polyurethane (PU) based Water proofing liquid compound as per manufacturer\"s instruction to stop leakage/seepage from roof/wall complete all as specified and directed.
71S&F in repair Pre- painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
72Dismantling of wrought iron orMild Steelwork of any description complete all as specified and directed by EIC complete all as specified and directed .
73S & F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc (cut to ordinary lengths i.e. with in 20 mm of the length indicated to FE 410-W (Gde-E-250 quality-B) complete all as specified and directed.
74M&L for preparation of new steel surfaces exc 10cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxideprimer all as specified.
75M&L in repair PVC floor trap/nahani trap ,plain with grating including jointing to waste pipe with solvent cement dia of outlet 75mm in repairs complete all as specified and directed .
76S&F of stainless steel kitchen stand /kitchenrack platebrand clasical kitchenware size 30x42(rbj)complete all as specified and directed by EIC complete all as specified and directed .
77S & F in repairs fancy type chromium plated cast copper alloy bib taps long shank & cup 15 mm dia bore complete all as specified and as directed.
78S & Fin repairPVC PTMT bib tap 15mm dia pipe with crutch or butter fly handle screwed down, screwed for iron pipe or forbrass ferrule complete with check nut 15mm bore complete all as specified and directed .
79S&F in repair of Wall mixture 15mm bore dia cast copper alloy with cap capston chromim plated screwed down high pressure with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly buts screwed for iron pipe complete all as specified and directed .
80S&F in repair 15 mm dia bore stop valve, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipes or for union and fixed complete all as specified and as directed.
81S & F in repairs 15 mm dia bore stop valves cast copper alloy chromium plated fancy type with long shank & cup (concealed type) complete all as specified and as directed.
82S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type angle cock with long shank & cup complete all as specified and as directed.
83Supply and fixed in repair 15 mm dia bore pillar taps cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or “cold’ with long screwed shank and flynuts, screwed for iron pipe and fixed complete all as specified and as directed.
84S & F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type wash basin mixerfor cold & hot water complete all as specified and as directed.
85Sch \"A\" Part-II (E/M Portion)
86Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody and making good disturbed surfaces of walls, floors etc all as specified as directed.
87Material & Labour for concealed point wiring with single core PVC insulated and unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sqmm nominal area drawn through & including non metallic rigid PVC conduit (circular/flat pvc conduit), medium duty not less than 20 mm dia concealed in wall/fixed with all fittings including tees , junction boxes, modular GI gang box & provision for modular box and modular cover of suitable size for mounting modular switches , sockets & regulators & drawing through continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with copper conductor solid conductor of size 1.5 sqmmcomplete all as specified & directed.Note: 1) Cost for cutting chases and making good to match the existing surface shall be deemed to be included in the quoted rate.2) Rates are deemed to be inclusive of Modular GI gang box & cover plates of any module & Qty as required on site.
88For one light point/call bell controlled by one single pole switch & socket complete all as specified and directed . .
89For one fan/exhaust fan point controlled by one single pole switch complete all as specified and directed .
90For one 3 pin sockets outlet 5 Amps on the same board with other switches with cable of size 1.5 sqmm complete all as specified and directed .
91For 3 pin socket outlet 5Amps independent with cable 1.5 Sqmm size complete all as specified and directed .
92For one 3 pin sockets outlet 15 Amps idependent with cables 2.5sqmm size complete all as specified and directed .
93Supply and Fixing in replacement of modular switches 1 way, 6 Amp 1 module complete all as specified & directed
94Supply and Fixing in replacement of modular switches 2 way, 6 Amp 1 module complete all as specified & directed
95Supply and Fixingin replacement of modular Socket, 6A - 2/3 pin combined 2 module with shutter, complete all as specified & directed.
96Supply and Fixing in replacement of modular switches 1 way, 16 Amp 1 module complete all as specified & directed.
97Supply and Fixingin replacement of modular Socket 6A/16A - 2/3 pin combined 2 module with shutter, complete all as specified & directed.
98S&F in replacement of Single pole and neutral enclosure with a two pin and earth including plug and socket complete set with one single pole MCB of 20 Amps,complete all as specified and directed.
99S&F Fan in replacement of modular fan regulator 4 step, 1 module, complete all as specified & directed.
100S&F in replacement of Modular Bell push 6A 1 module,complete all as specified & directed
101S&F in replacement of Ding Dong AC. 230 volts, single pole,complete all as specified & directed
102Supply & Fixing in replacement of Ceiling Rose, 3 phase polycarbonate isolated body complete all as specified & directed.
103M&L for Taking out the unserviceable wall mountedPanel boardincluding all connection and supply,installation, commissioning and testing of LT panel, indoor type, double door, IP 65 Protection, CPRI Approvedbase frame mounted dust proof and vermin proof with bus bar of 400 Amps current capacity to accommodate 3 Phase, 415Volt with suitable aluminium busbar designed as per relevant IS connectedto busbar by aluminium strip of suitable Size, fabricated out of 3.15 mm thick CRCA sheet for outer chamber and 2 mm thick for partition and doors and painting with seven tank process with twin shutter closing, locking arrangements and with 2 nos earthing sprout connectors complete and fixed in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation 40 cm above ground levelincluding provision for fixing of MCCB 250A, 50 KA, 4Pole -1 Nos (Incomer), Digital VAF Meter, LED Indication Lamps, CT\"s etc and outgoing MCCB 200A, 36KA, 3 Pole-2 Nos, outgoing mcb 40 A, k0 KA, 4 pole - 2 nos, along with spare space for fixing of 01 Nos MCCB complete control wiring for the above accessoriesall as specified and as directed.
104Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board8 waywith incomer MCCB of 200Amps, 4 pole, 36KA, fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-54 protection) fixed on wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 Note: (i) Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
105Supply and fix in replacement of factory made epoxy polyster powder coated distribution board SP&N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, suitable for one incomingand 6 outgoings complete all as specified and confirming to IS: 8623 (Make: Legrand /Siemens). Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.
106S&F in repalcement of MCB SP 6-32 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed.
107S&F in repalcement of MCB SPN 40 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed.
108S&F in repalcement of MCB SP 63 Amps ,10 KA 230 Volts ,50 HZ complete all as specified and as directed.
109S& F in replacement of MCCB 200Amps, 36 KA, 4 Pole, with thermal & megnetic release setting, including spreader, complete all as specified and directed.
110S&F in replacement of submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
111S&F in replacement of submain wiring withunsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 10 Sqmm single core HR Grade and one run of 10 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB/ Geyser/ AC plug points complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.
112M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised ironstrip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated complete all as specified and directed.
113S&F in replacement of LED retrofit tubelight, 4 ft longof 20 watt,complete all as specified and directed.
114S&F in replacement of LED2 ft retrofit tubelight of 10 watt,complete all as specified and directed.
115S&F in replacement Powder coated pressure die cast aluminium compact LED building light/ street light of 45watt confirming to IP 65, complete all as specified and as directed by Engineer -in-charge. Make: Crompton cat No: LSTS-45-CDL or equivalent make of Philips /Wipro/C&S/Havell\"sNote: Twin core copper wire of 1.5 Sqmm upto 7Rm required for connection of street light fitting is deemed to be included in quoted rates
116S&F in replacement of Street light bracket of size 40mm dia light grade GI pipe, including nut, bolts, Fastner etc, complete all as specified & directed.
117Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site of size 20 mm bore, complete all as specified and directed.
118Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site o Bore of pipe 25 mm, complete all as specified and directed.
119Supply and laying in replacement of galvanised steel water tubing medium grade in trenches / wall /floor with all fittings , connections as required at site o Bore of pipe 50mm, complete all as specified and directed.
120S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 20 mm bore, complete all as specified and directed.
121S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 25 mm bore, complete all as specified and directed.
122S&F in replacement of Stop valve gun metal valve with iron handle screwed both ends for iron pipe and fixed of size 50 mm bore, complete all as specified and directed.
123S&F in replacement of GI union of 20 mm ISI marked complete all as specified and directed.
124S&F in replacement of GI union of 25 mm ISI marked complete all as specified and directed.
125S&F in replacement of GI union of 50 mm ISI marked complete all as specified and directed.
126Supply and fixing in replacement of PVC float valve, high pressure (ball cock bady with epoxy coated aluminium rod & HD ball) of size 50 mm dia.including all fittings, complete all as specified and directed.
127S&F in replacement of PPR gate valve (brass insert) of size 63 mm dia including connection and testing complete all as specified and directed including taking out old unserviceable gun metal gate valve 50mm dia Complete all as specified and directed
128Supply and fixing in replacement of triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part I. of size 5000 Ltrscomplete all as specified and directed.. e
129S&F in replacement of GI tank Nipple of 50mm dia, complete all as specified & directed.
130Supply & laying/fixing in replacement of 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded PP-R (polypropylene Random Co-Polymer) pipes, ISI marked including plain PP-R fittings and brass threaded PP-R fittings such as flanges, elbow, bend, sockets, tee etc. as required at site and testing of joints complete all as specified and as directed of size (a) PN-16, 63mm OD (SDR– 7.4) including taking out old rusted GI pipe of 50mm dia.Note: Contractor has to provide heater & othere T&P for jointing of PPR pipe, rate are deemed to be inculede in quoted rate.
131S&F in replacement of PPR union of size 90 mm dia including connection and testing complete all as specified and directed.
132S&F in replacement of PPR union of size 63 mm dia including connection and testing complete all as specified and directed.
133S&F in replacement of PPR union of size 32 mm dia including connection and testing complete all as specified and directed.
134S&F in replacement of PPR socket of size 90 mm dia including connection and testing complete all as specified and directed.
135S&F in replacement of PPR MTA of size 90 mm dia including connection and testing complete all as specified and directed.
136S&F in replacement of PPR MTA of size 63 mm dia including connection and testing complete all as specified and directed.
137S&F in replacement of PPR MTA of size 32 mm dia including connection and testing complete all as specified and directed.
138S&F in replacement single phase Direct on line starter of capacity 2 HP overload relay range 10-17 Amp.Make- L&T Cart part No: SS97227OOBO /Havell\"s/ Seimens/ Schineder or equivalent ISI marked.
139Excavation in trenches in soft / loose soil nexc 1.5 mtr wide and not exc 1.5 m in depth etc complete and getting out in soft soil inciuding trimming sides and bottom of trenches complete all as specified and directed by Engr-in- charge.
140Retuning filling in trenches including watering and well ramming in layer not exc 25 cm thick in soft/ loose soil complete all as specified and directed by Engr-in- charge.
141Removing excavated surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting pointall as specified.
142S&F in replacement of tank cover suitable for 5000Ltr cap tankcomplete all as specified and directed.
143Schedule of Credit

AI Tender Summary

OUR REF NO 41937396
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 80 Lakhs
LAST DATE 05-03-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Integrated Comprehensive Maintenance Of Smq Block No- P-2, P-11 And P-26 At Af Station Tughalakabad Under Ge (Af) Tughlakabad.
Basic Detail
Tender No CA NO. CWE/TKD/TOKEN-85 OF 2023-24
Bidding Type Tender
Location
City tughlakabad
State Delhi
Key Dates
Publish Date 27 Feb 2024
Submission Date 05 Mar 2024
Open Date 07 Mar 2024
Finance
Tender Value 80 Lakhs
Tender Fee 1000
EMD 1.45 Lakhs
Exemption Not Available
Document List
Tender_Doc.pdf
22b19bea-4c4f-42f6-8703-6f4b6b76af23.html
BOQ_716254.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 27, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 27, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 05, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 05, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 07, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tender_Doc.pdf

html

22b19bea-4c4f-42f6-8703-6f4b6b76af23.html

xls

BOQ_716254.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders