Fixing The Job Contract (Labour) For Repair/Reclamation Of Damaged Distribution Transformers Of Different Capacities Viz 25 Kva, 50/63 Kva, 100 Kva, 200/250 Kva, 300 Kva, 400 Kva, 500 Kva , 630 Kva At Workshop Of Ed I Parade Jammu- 1 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 25KVA DTR 2 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 3 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 4 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 5 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 6 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 7 Labour Charges for painting of Transformer tank, radiators (Complete Job). 8 Impregnation and heat treatment of coils (upto 630 KVA) 9 Winding of HV Leg Coil (Copper/Aluminium). 10 Winding of LV Leg Coil (Copper/Aluminium). 11 Rewinding of LV leg (Copper/Aluminium). 12 Labour charges for filtration of transformer oil 13 Refitting/ Replacement of Bushing only HV/LV 14 Refitting/ Replacement of Bush rod only HV/LV 15 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 16 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 50/63KVA DTR 17 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 18 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 19 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 20 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 21 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 22 Labour Charges for painting of Transformer tank, radiators (Complete Job). 23 Impregnation and heat treatment of coils 24 Winding of HV Leg Coil (Copper/Aluminium). 25 Winding of LV Leg Coil (Copper/Aluminium). 26 Rewinding of LV leg (Copper/Aluminium). 27 Labour charges for filtration of transformer oil 28 Refitting/ Replacement of Bushing only HV/LV 29 Refitting/ Replacement of Bush rod only HV/LV 30 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 31 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 100KVA DTR 32 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 33 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 34 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 35 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 36 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 37 Labour Charges for painting of Transformer tank, radiators (Complete Job). 38 Impregnation and heat treatment of coils 39 Winding of HV Leg Coil (Copper/Aluminium). 40 Winding of LV Leg Coil (Copper/Aluminium). 41 Rewinding of LV leg (Copper/Aluminium). 42 Labour charges for filtration of transformer oil 43 Refitting/ Replacement of Bushing only HV/LV 44 Refitting/ Replacement of Bush rod only HV/LV 45 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 46 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 200/250KVADTR 47 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 48 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 49 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 50 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 51 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 52 Labour Charges for painting of Transformer tank, radiators (Complete Job). 53 Impregnation and heat treatment of coils 54 Winding of HV Leg Coil (Copper/Aluminium). 55 Winding of LV Leg Coil (Copper/Aluminium). 56 Rewinding of LV leg (Copper/Aluminium). 57 Labour charges for filtration of transformer oil 58 Refitting/ Replacement of Bushing only HV/LV 59 Refitting/ Replacement of Bush rod only HV/LV 60 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 61 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 300KVA DTR 62 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 63 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 64 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 65 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 66 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 67 Labour Charges for painting of Transformer tank, radiators (Complete Job). 68 Impregnation and heat treatment of coils 69 Winding of HV Leg Coil (Copper/Aluminium). 70 Winding of LV Leg Coil (Copper/Aluminium). 71 Rewinding of LV leg (Copper/Aluminium). 72 Labour charges for filtration of transformer oil 73 Refitting/ Replacement of Bushing only HV/LV 74 Refitting/ Replacement of Bush rod only HV/LV 75 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 76 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 400KVA DTR 77 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 78 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 79 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 80 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 81 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 82 Labour Charges for painting of Transformer tank, radiators (Complete Job). 83 Impregnation and heat treatment of coils 84 Winding of HV Leg Coil (Copper/Aluminium). 85 Winding of LV Leg Coil (Copper/Aluminium). 86 Rewinding of LV leg (Copper/Aluminium). 87 Labour charges for filtration of transformer oil 88 Refitting/ Replacement of Bushing only HV/LV 89 Refitting/ Replacement of Bush rod only HV/LV 90 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 91 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 500KVA DTR 92 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 93 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 94 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 95 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 96 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 97 Labour Charges for painting of Transformer tank, radiators (Complete Job). 98 Impregnation and heat treatment of coils 99 Winding of HV Leg Coil (Copper/Aluminium). 100 Winding of LV Leg Coil (Copper/Aluminium). 101 Rewinding of LV leg (Copper/Aluminium). 102 Labour charges for filtration of transformer oil 103 Refitting/ Replacement of Bushing only HV/LV 104 Refitting/ Replacement of Bush rod only HV/LV 105 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer . 106 Repair/Reclamation of Damaged Distribution Transformers (11KV/6.6KV/0.44KV) 630KVA DTR 107 Opening of transformer, draining of oil, opening of HV /LV connections, taking out core, opening of side channel lamination complete job. 108 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damage HT Coils (Three limbs) 109 Taking out of all the coils after opening the connection and inspection of coils to ascertain the damageLT Coils (Three limbs) 110 Labour Charges for cleaning & washing of transformer tank, radiators top covers etc. 111 Labour Charges for repairing, welding of transformer tank, radiators, Arresting of Oil Leakages etc., if any 112 Labour Charges for painting of Transformer tank, radiators (Complete Job). 113 Impregnation and heat treatment of coils 114 Winding of HV Leg Coil (Copper/Aluminium). 115 Winding of LV Leg Coil (Copper/Aluminium). 116 Rewinding of LV leg (Copper/Aluminium). 117 Labour charges for filtration of transformer oil 118 Refitting/ Replacement of Bushing only HV/LV 119 Refitting/ Replacement of Bush rod only HV/LV 120 Labour Charges for Re-assembling, refitting of coils, including all sundry items to be replaced & re-tanking up of assembled core, refitting & testing of transformer .