Housing Urban and Rular Development Government Departments Closing in 0 days TDR #41920286

Tender For Construction Of New Fire Station At Seijosa, Pakke Kesang District

Issued by Government Departments · Pakke Kessang, Arunachal Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Feb 2024
0 days left
EMD
2.41 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pakke Kessang → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction Of New Fire Station At Seijosa, Pakke Kesang District, Ap

BOQ

Name of Work: Const. of New Fire Station at Seijosa, Pakke Kessang District
Sl. No. Item Description
1FIRE STATION BUILDING
2Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) Ordinary Soil
3b) Hard Soil
4Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
5Sand Filling in Foundation Trenches as per Drawing & Technical Specification
6Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
7Dry rubble Flooring
8Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in: a) Foundations and plinth
9Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in :b)in walls etc.
10Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
11Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
12Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
13Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
14Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
15Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers bands and facias up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding the 6 mm to give a smooth and even surface but excluding the cost of centering, shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 fine sand : 4 stone aggregate 12.5 mm nominal size).
16Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
17Centring and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
18b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
19c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
20d) Lintels, beams, girders, bressumers and cantilevers etc.
21e) Column, pillars, posts and struts etc.
22f) Stairs (excluding landings) except spiral stair cases.
23g)Vertical and horizontal fins individually or forming box louvers bands and facias.
24Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/TMT steel.
25Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
26Extra for brick work in superstructure above floor two level, per floor per Cu.m. (1% of rate of brickwork from plinth up to floor two level).
27Half brick masonry (with best available local bricks) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth.
28Extra for half brick masonry in superstructure above plinth level and up to floor two level.
29Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
30Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40 mm thick including anodized aluminum butt hinges with necessary screws.
3135 mm thick factory made solid panel PVC door shutter of single piece extruded profile decorative finished (Wood grand finished)
32Providing and fixing best available local wood glazed shutters for doors, windows and clerestory window using 7.5 kg/Sq.m. (3 mm thick glass panes) including black enamelled MS butt hinges with necessary screws. a) 35 mm thick
33Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I.
34Providing and fixing 12 mm thick and 100 mm wide pelmet with 25 mm dia wooden curtain rod and brackets including fixing with 25 x 3 mm MS flat 10 cm long and plugs etc complete.a) Timber class - A IV
35Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill.
36Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
37Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete.a) 300 x 10 mm
38b) 150 x 10 mm
39Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm
40Providing and fixing MS Hooks and Eyes.c) 200 mm
41Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
42Providing and fixing iron pressed butt hinges bright finished with necessary screws etc complete. a) 125 x 65 x 2.12 mm
43b) 75 x 47 x 1.70 mm
44Providing and fixing 50 cm long aluminum kicking plate 100 x 3.15 mm anodised, transparent or dyed to required color or shade with necessary screws etc complete.
45Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete a) Size of Tile 1000x1000 mm
46Extra,if terrazzo tiles are laid in treads of steps not exceeding 30 cm in width.
47Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: c) Dark shade using ordinary cement
48Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/and residual bitumen applied hot @ 1.45,1.20 & 1.45 Kg. per Sq.m. of area respectively, second & fourth courses of roofing felt type-3 grade-I (hessian base finished bitumen felt) and sixth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per Sq.m. including preparation of surface excluding grading complete.
4912 mm cement plaster 1 : 6 (1 cement : 6 fine sand).
5020 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
51Neat cement punning.
52Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
53Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
54Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
55Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
56Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
57Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
58Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
59WATER SUPPLY AND SANITARY FITTINGS
60Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore
61b) 20 mm nominal bore
62Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).a) 15 mm nominal bore
63b) 20 mm nominal bore
64c) 32 mm nominal bore
65Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore
66Providing and fixing brass stop cock of approved quality.a) 32 mm nominal bore
67Providing and fixing brass full way valve with wheel of approved quality.a) 32 mm nominal bore
68Providing and fixing non-return valve of approved quality.b) 32 mm nominal bore
69SANITARY INSTALLATION
70Providing laying and jointing glazed stone ware pipe grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. a) 100 mm dia SW pipes
71Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15cm thick as per standard design.a) 100 mm dia SW pipes
72Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.
73Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making good the walls and floors where required.a) WC pan with white plastic seat and lid.
74Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC a) 250 x 130 x 30 mm
75Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
76Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.
77Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
78Providing and fixing CP brass towel rail complete with CP brass brackets fixed to wooden cleadt with CP brass screws (heavy quality).a) 750 x 20 mm size
79Providing and fixing toilet paper holder.a) CP Brass
80Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.c) 50 mm dia
81Providing and fixing sand cast iron heel rest sanitary bend.a) 100 mm dia
82Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm
83Providing and fixing sand cast iron trap of self cleadnsing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.c) 100 mm inlet and 100 mm outlet
84Providing and fixing on wall face C.I. rain water pipe including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement : 2 fine sand).b) 100 mm diameter pipe
85Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10 cm x 10 cm x 10 cm of 1 : 2 : 4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc.b) 100 mm diameter
86Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1 : 2 ( 1 cement: 2 fine sand).(C) CI Plain shoes :b) 100 mm diameter
87Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
88Constructing brick masonry manhole with 2nd class bricks in cement mortar 1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design.a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).
89Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
90Carryingcharges
91Internal Electrical installation
92Septic Tank
93Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
94Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
95Half brick masonry (with best available local bricks)in cement mortar 1:3 (1cement : 3 coarse sand) in foundation and plinth.
96Extra for half brick masonry in superstructure above plinth level and up to floor two level.
97Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
98Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete
99b)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
100Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild Steel
10115 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.
102Neat cement punning.
103Providing and fixing on wall face asbestos cement soil, waste and vent pipes including jointing with spun yarn soaked in bitumen and cement mortar 1 : 2 (1 cement : 2 coarse sand) complete. a) 100 mm dia
104Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. A) 100 mm dia.
105Construction of soak pit 1.2 x 1.1 x 1.2 m filled with brick bats including SW drain pipe 100 mm dia and 1.20 m long complete as per standard design
106Add Carrige charges
107Entrance Gate (In & Out)
108Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
109Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
110Reinforcement of RCC work including bending, binding and placing in position completeb) TMT
111Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
112e) Column, pillars, posts and struts etc.
113d) Lintels, beams, girders, bressumers and cantilevers etc.
114Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). .
115Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
116Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
117Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. b) In Tees, Angles and Channels
11812 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
119Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
120Applying one coat of cement primer of approved brand and manufacture on wall surface.
121Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
122Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
123Add Carrige charges
124EXTENSION OF B/WALL HEIGHT
125Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
126Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. (a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
127Reinforcement of RCC work including bending, binding and placing in positioncomplete. (a) TMT Bar
128Centring and shuttering including strutting, propping etc and removal of form work for : a) Columns
129b) Lintel/Beams
130Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).
13112 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
132Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. a) In Tees, Angles and Channels
133Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
134Applying one coat of cement primer of approved brand and manufacture on wall surface.
135Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to givean even shade.
136Carriage for material
137UG TANK
138Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. a) OrdinarySoil
139Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
140Reinforced work in foundation footing, bases of columns, etc. and Mass concrete excluding cost of centering andshuttering, finishing and reinforcementin M20 1:1.5:3 (1 cement :1.5 coarse Sand :3 Stone Aggregate 20 mm nominal size)
141Reinforced cement concrete inwall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : b)M201 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
142Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).in M20 1:1.5:3 (1 cement :1.5 coarse Sand :3 Stone Aggregate 20 mm nominal size)
143Centering & Shuttering …a) Foundation, footings, bases of columns etc. and mass concrete.
144b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
145c) Suspended Floors
146Reinforcement of RCC work including bending, binding and placing in position complete. a. TMT Bars
147Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
148Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. Rectangular shape 600x450 mm internal dimensions
14912 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
150Neat cement punning.
151Carriage of Materials
152DISMANTLING OF OLD STRUCTURES
153Demolishing RCC work including stacking of steel bars and disposal of un-serviceable materials within 50 metres lead.
154Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
155Dumping of unserviceable material to dumping site
156Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
157PARKING AREA
158Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, intoplinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. (a) OrdinarySoil
159Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:
160Cenbtering & Shuttering a) Foundation, footings, bases of columns etc. and mass concrete.
16112 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
162Carriage of Materials

AI Tender Summary

OUR REF NO 41920286
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-02-2024
Authority
Authority Name Urban Development And Housing Department
Work Description Tender For Construction Of New Fire Station At Seijosa, Pakke Kesang District, Ap
Basic Detail
Tender No CEUD/PLG/HOME-470/2023-24
Bidding Type Tender
Location
City Pakke Kessang
State Arunachal Pradesh
Key Dates
Publish Date 30 Jan 2024
Submission Date 06 Feb 2024
Open Date 06 Feb 2024
Finance
Tender Value Ref. Documents
Tender Fee 5000
EMD 2.41 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
36b6061e-94c6-4173-a5ad-507d8b6a368b.html
SBD.pdf
BOQ_1767.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 30, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 06, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 06, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

36b6061e-94c6-4173-a5ad-507d8b6a368b.html

pdf

SBD.pdf

xls

BOQ_1767.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders