Jal Jeevan Mission (Jjm)-Phase 2 -Wss To Chathamangalam And Adjoining 7 Panchayaths-Additional Proposal For Full Coveragein Kizhakkoth Panchayath - Supplying, Laying, Testing And Commissioning Of Additional Distribution Linesfor Providing Functional House, Kozhikode-Kerala

Kerala Water Authority-KWA has published Jal Jeevan Mission (Jjm)-Phase 2 -Wss To Chathamangalam And Adjoining 7 Panchayaths-Additional Proposal For Full Coveragein Kizhakkoth Panchayath - Supplying, Laying, Testing And Commissioning Of Additional Distribution Linesfor Providing Functional House. Submission Date for this Tender is 08-02-2024. Water Pipe Line Tenders in Kozhikode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41919862
Jal Jeevan Mission (Jjm)-Phase 2 -Wss To Chathamangalam And Adjoining 7 Panchayaths-Additional Proposal For Full Coveragein Kizhakkoth Panchayath - Supplying, Laying, Testing And Commissioning Of Additional Distribution Linesfor Providing Functional House
Open Tender
Indian
Kerala
Kozhikode
08-02-2024

Tender Details

Jal Jeevan Mission ( Jjm ) -Phase 2 -Wss To Chathamangalam And Adjoining 7 Panchayaths-Additional Proposal For Full Coveragein Kizhakkoth Panchayath - Supplying, Laying, Testing And Commissioning Of Additional Distribution Linesfor Providing Functional Household Tap Connections-Pipeline Work- 1 Appendix A - Supplying, Laying, Testing And Commissioning Of Network - Additional Length - Cost Of Materials 2 Od211920 / 2023-2024:Supply Of Pvc Pipe, 12.5Kg / Cm2, 90Mm Dia. 3 Od47596 / 2023-2024:Add 3% Of Pvc Specials 4 Od47597 / 2023-2024:Supply 80Mm Gi Pipe Class B 5 100.98.440:Supply Of Ci Air Valve, Conforming To Is 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25Mm. 6 100.98.457:Supply Of Ci Double Flanged Sluice Valve Conforming To Is 14846 - 2000, Sluice Valve With Cap Pn 1.6, Size 80Mm. 7 Appendix B - Supplying, Laying, Testing And Commissioning Of Network - Additional Length - Working Charges 8 15.3:Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. 9 15.9.2:Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar 10 100.59.1:Cutting The Bituminous / Concrete Roads With Cutting Machine For A Minimum Depth Of 200Mm Along The Sides Of Proposed Alignment Of The Pipe To Be Laid Without Causing Any Damage To Other Utilities, Including The Charges For Hire And Conveyance Of Tools And Plant, Cost Of Consumables And Charges For Lighting, Watching, Ribbon Fencing, Caution Boards, Traffic Diversion, And As Per The Direction Of Departmental Officers Etc. Complete, Before Carrying Out The Demolition Of Bituminous / Concrete Road By Mechanical Means And Carrying Out The Excavation. 11 Od47599 / 2023-2024:Dismantling Manually / By Mechanical Means And Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer -In-Charge:<Br>Bituminous Road 12 Od47600 / 2023-2024:Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.<Br>Nominal Concrete 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) For Road Work 13 100.1.1:Excavating Trenches Of Required Width For Pipes, Cables, Etc., Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc., And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50M, In All Kinds Of Soil. 14 100.1.5:Excavating Trenches Of Required Width For Pipes, Cables, Etc., Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc., And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M, In Ordinary Rock. 15 100.2.2:Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10M2 On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50M, In Medium Rock Where Blasting Is Prohibited. 16 100.1.9:Excavating Trenches Of Required Width For Pipes, Cables, Etc., Including Excavation For Sockets, And Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc., And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50M, In Hard Rock Requiring Blasting. 17 100.8.1:Fencing One Side Of Trenches, 1.50M Height With Two Rows Of 10Cm Plastic Caution Tape In Vertical Casuarina Pole ( Girth 15Cm To 24Cm ) Fixed At 2M Intervals. 18 100.9.8:Laying Upvc Pipes Of Class 2 To Class 6 And Specials, Lowering To The Trenches Already Made, Placing In Position Aligning The Pipeline To The Lines And Levels And Jointing The Pipes And Specials With Solvent Cement And Testing The Pipeline With Water To The Required Test Pressure ( Excluding Cost Of Pipes And Specials ) : 90 Mm Nominal Outside Diameter Pipes. 19 100.12.8:Conveying And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc., But Excluding Cost Of Pipes And Fittings For External Work: 80Mm Diameter Nominal Bore. 20 100.31.1.1:Conveying And Fixing C.I. Sluice Valves ( With Cap ) By Providing Bolts, Nuts, Rubber Insertions Etc., Complete, But Excluding The Cost Of The Valve ( Tail Pieces, If Required, Will Be Paid Separately ) : 80Mm Diameter, Class I. 21 100.32.1:Conveying And Fixing C. I. Single Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc., Complete, But Excluding The Cost Of Air Valve ( Tail Pieces, If Required, Will Be Paid Separately ) : 25Mm Single Acting Air Valve. 22 Od47601 / 2023-2024:Supplying And Fixing 150Mm Ci Surface Box Embeded With Rcc Slab Of Size 0.6X0.6X0.15 And 160Mm Or Above Size Pvc 10Kg / Cm2 Pipe Acting As Protection Tube With Including All Cost Of Conveyance, Labour Charges Etc.Complete 23 2.6.1:Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed.All Kinds Of Soil 24 5.1.3:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 25 5.9.2:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 26 5.22A.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More 27 100.60.13.1.2:Providing 15Mm ( 1 / 2 Inch ) House Connection With 15Mm Water Meter From Existing Pvc / Hdpe Mains Up To 110 Mm Dia., Up To A Length Of 5M Using 20Mm ( 1 / 2 Inch ) Pe Pipe, Pe80, Pn16, Conforming To Is 4984: 2016 Or Later Edition And Pp Pn 16 Compression / Gm / Brass Specials Viz. Brass Ferrule, Brass Hexagonal Nipple, Gm Full Way Wheel Valve, Bend, Mta, Fta, Couplers, Pvc Service Saddle Of Suitable Size Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges, Including The Cost Of Tested Class B Multijet Water Meter With Isi Mark And Weather Resistant Pp / Pe Meter Box Of Minimum Size 300Mm X 200Mm X 150Mm, But Excluding Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, And As Per The Direction Of The Departmental Officers. 28 100.60.14.1.2:Providing 15Mm ( 1 / 2 Inch ) House Connection With 15Mm Water Meter From Existing Pvc / Hdpe Mains From 140Mm To 200Mm Dia., Up To A Length Of 5 M Using 20Mm ( 1 / 2 Inch ) Pe Pipe, Pe80, Pn16, Conforming To Is 4984: 2016 Or Later Edition And Pp Pn 16 Compression / Gm / Brass Specials Viz. Brass Ferrule, Brass Hexagonal Nipple, Gm Full Way Wheel Valve, Bend, Mta, Fta, Couplers, Pvc Service Saddle Of Suitable Size Etc. And Connecting With The Mains, Testing The Joints Etc. Complete Including Trenching And Refilling In All Kinds Of Soil Up To A Depth Of 1.50M For Main Line Tracing And Trench Of Average Cross Section 0.3M X 0.75M For Laying Connection Pipe And Service Pipe, Fixing Water Meter, Lighting, Watching, Providing Caution Boards, Traffic Control Etc. Complete Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges, Including The Cost Of Tested Class B Multijet Water Meter With Isi Mark And Weather Resistant Pp / Pe Meter Box Of Minimum Size 300Mm X 200Mm X 150Mm, But Excluding Charges For Cutting The Concrete / Tarred / Bituminous Roads Etc, And As Per The Direction Of The Departmental Officers. 29 100.60.15.1.1:Providing Additional Length Of House Connection Pipe Using 20 Mm ( 1 / 2 Inch ) Pe Pipe, Pe80, Pn16, Conforming To Is 4984: 2016 Or Later Edition And Pn16 Specials And Testing The Joints Etc., By Trenching And Refilling In All Kinds Of Soil With Trench Of Average Cross Section 0.3M X 0.75M For Laying Of Connection Pipe And Service Pipe, Lighting, Watching, Providing Caution Boards, Traffic Control Etc., Including Cost Of Materials, Hire For Tools, Cost Of Consumables And Labour Charges Etc. Complete, But Excluding The Cost Of Cutting Of Concrete / Tarred / Bituminous Roads Etc., And As Per The Directions Of The Department Officers. 30 100.60.22.1.1:Providing 15Mm ( 1 / 2 Inch ) Gm Check Valve In The Water Meter Assembly For 15Mm Water Connection, Using 20Mm ( 1 / 2 Inch ) Pe Pipe, Pe80, Pn16, Conforming To Is 4984: 2016 Or Later Edition And Pp Pn 16 Compression Specials Including Cost Of Materials, Consumables, Hire For Tools And Labour Charges Etc. Complete And As Per The Directions Of The Department Officers. 31 100.60.12.3.1:Providing 15Mm Pvc Tap In The Water Meter Assembly For 15Mm Connection, Using 20Mm Indian Standard Class 6 Upvc Pipes And Specials Including Cost Of Materials, Consumables, Hire Charges For Tools And Labour Charges Etc. Complete And As Per The Direction Of Departmental Officers. 32 Od251242 / 2023-2024:Providing And Fixing Water Tap Post Using 75 Mm Pvc 6Kg / Cm2 Pipe Including Cost Of Pipe, End Cap, Filling With Sand And Fixing In Position With 60X60x10cm Concrete Base Etc. Complete. 33 Od214235 / 2023-2024:Providingand Fixing Cement Concrete Tray For Mounting Water Meter Box Having Size 40 X 30 X 10Cmincluding Cost Of Materials, Consumables, Hire Charge For Tools And Labour Charges Etc. Complete As Per The Direction Of The Department Officers. 34 100.41.39:Supply, Stacking, Spreading And Consolidating Of Quarry Muck In The Trench Of Pipe Line, Including Carriage, Loading, Unloading & Stacking Up To Any Lead. 35 Appendix C- Road Restoration - Panchayath Roads 36 3.5.3:Excavation In Soil Using Hydraulic Excavator And Tippers With Disposal Upto 1000 Mexcavation For Roadwork In Soil With Hydraulic Excavator Of 0.9 Cum Bucket Capacity Including Cutting And Loading In Tippers, Trimming Bottom And Side Slopes, In Accordance With Requirements Of Lines, Grades And Cross-Sections, And Transporting To The Embankment Location With A Lift Upto 1.5 M And Lead Upto 1000 M As Per Technical Specification Clause 302.3 37 4.1.A.1:Granular Sub-Base With Well Graded Material ( Table 400.1 ) ( A ) By Mix In Place Methodconstruction Of Granular Sub-Base By Providing Well Graded Material, Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Smooth Wheel Roller To Achieve The Desired Density, Complete As Per Technical Specification Clause 401. ( I ) For Grading I Material 38 4.9:Wet Mix Macadamproviding, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mixer ( Pug Mill ) , Carriage Of Mixed Material By Tipper To Site, Laying In Uniform Layers In Sub-Base / Base Course On A Well Prepared Sub-Base And Compacting With Smooth Wheel Roller Of 80 To 100Kn Weight To Achieve The Desired Density Including Lighting, Barricading And Maintenance Of Diversion, Etc As Per Tables 400.11 & 400.12 And Technical Specification Clause 406.By Mechanical Means With 1 Km Lead 39 5.1.1A:Prime Coat :- Low Porosityproviding And Applying Primer Coat With Bitumen Emulsion ( Ss-1 ) On Prepared Surface Of Granular Base Including Cleaning Of Road Surface And Spraying Primer At The Rate Of 0.70-1.0 Kg / Sqm Using Mechanical Means As Per Technical Specification Clause 502 40 5.2.3A:Tack Coat Providing And Applying Tack Coat With Bitumen Emulsion ( Rs-1 ) Using Emulsion Distributor At The Rate Of 0.25 To 0.30 Kg Per Sqm On The Prepared Granular Surfaces Treated With Primer & Cleaned With Hydraulic Broom As Per Technical Specification Clause 503. 41 5.9.1.2A:20Mm Thick Open-Graded Premix Carpet Using Bituminous ( Penetration Grade / Modified Bitumen ) Binder - Bitumen S-65Providing, Laying And Rolling Of Open-Graded Premix Carpet Of 20 Mm Thickness Composed Of 13.2 Mm To 5.6 Mm Aggregates Either Using Penetration Grade Bitumen Or Emulsion To Required Line, Grade And Level To Serve As Wearing Course On A Previously Prepared Base, Including Mixing In A Suitable Plant, Laying And Rolling With A Three Wheel 80-100 Kn Static Roller Capacity, Finished To Required Level And Grades To Be Followed By Seal Coat Of Either Type A Or Type B Or Type C As Per Technical Specification Clause 508.Case - I By Manual Means ( Ii ) Bitumen ( S-65 ) 42 5.12.A.3.2A:Seal Coat - Manual Means - Type C - Bitumen S-65Providing And Laying Seal Coat Sealing The Voids In A Bituminous Surface Laid To The Specified Levels, Grade And Cross Fall Using Type A, Type B And Type C As Per Technical Specification Clause 510A. By Manual Means :- Case - Iii : Type C ( Ii ) Bitumen ( S-65 ) 43 75.8.1:Providing Plain Cement Concrete For Road Work Cc 1:2:4 ( 1 Cement: 2 Fine Aggregate: 4Course Aggregate ) Laid To Required Slope And Camber In Panels ( @ 3 M C / C ) As Requiredincluding Compaction, Finishing And Tamping Etc .Complete. Max. Size Of Courseaggregate Not Exceeding 25Mm , Mixed In Concrete Mixer Etc Complete As Perspecification ( I ) Nominal Mix ( 1:2:4 )

Key Value

Document Fees
INR 16540 /-
EMD
INR 500000.0 /-
Tender Value
INR 10.39 Crore /-

BOQ Items

Work Name:Jal Jeevan Mission (JJM)-Phase 2 -WSS to Chathamangalam and adjoining 7 Panchayaths-Additional proposal for full coveragein Kizhakkoth Panchayath - Supplying, laying, testing and commissioning of additional distribution linesfor providing Functional Household Tap Connections-Pipeline Work
Sl. No. Item Description
1Appendix A - Supplying, laying, testing and commissioning of network - Additional length - cost of materials
2OD211920/2023-2024:Supply of PVC Pipe, 12.5kg/cm2, 90mm Dia.
3OD47596/2023-2024:Add 3% of PVC specials
4OD47597/2023-2024:Supply 80mm GI Pipe Class B
5100.98.440:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.
6100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
7Appendix B - Supplying, laying, testing and commissioning of network - Additional length - working charges
815.3:Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
915.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
10100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
11OD47599/2023-2024:Dismantling manually / by mechanical means and disposal of material within 50 metres lead as per direction of Engineer -in-Charge:<br>Bituminous road
12OD47600/2023-2024:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.<br>Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) for road work
13100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
14100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
15100.2.2:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10m2 on plan), including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
16100.1.9:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Hard Rock Requiring Blasting.
17100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
18100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
19100.12.8:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 80mm diameter nominal bore.
20100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
21100.32.1:Conveying and fixing C. I. Single Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 25mm Single Acting Air Valve.
22OD47601/2023-2024:Supplying and fixing 150mm CI surface box embeded with RCC slab of size 0.6x0.6x0.15 and 160mm or above size PVC 10Kg/cm2 pipe acting as protection tube with including all cost of conveyance, labour charges etc.complete
232.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
245.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
255.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
265.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
27100.60.13.1.2:Providing 15mm (1/2 inch) house connection with 15mm water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5m using 20mm ( 1/2 inch ) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression / GM / Brass specials viz. brass ferrule, brass hexagonal nipple, GM full way wheel valve, bend, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
28100.60.14.1.2:Providing 15mm (1/2 inch) house connection with 15mm water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm ( 1/2 inch ) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression / GM / Brass specials viz. brass ferrule, brass hexagonal nipple, GM full way wheel valve, bend, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
29100.60.15.1.1:Providing additional length of house connection pipe using 20 mm (1/2 inch) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PN16 specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.
30100.60.22.1.1:Providing 15mm ( 1/2 inch ) GM Check Valve in the water meter assembly for 15mm water connection, using 20mm ( 1/2 inch ) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.
31100.60.12.3.1:Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.
32OD251242/2023-2024:Providing and Fixing Water Tap post using 75 mm PVC 6Kg/cm2 pipe including cost of pipe, end cap, filling with sand and fixing in position with 60x60x10cm Concrete Base etc. complete.
33OD214235/2023-2024:Providingand fixing cement concrete tray for mounting water meter box having size 40 x 30 x 10cmincluding cost of materials, consumables, hire charge for tools and labour charges etc. complete as per the direction of the department officers.
34100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
35Appendix C- Road restoration - Panchayath roads
363.5.3:Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
374.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1)(A) By Mix in Place MethodConstruction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(i) For Grading I Material
384.9:Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.By Mechanical Means with 1 km lead
395.1.1a:Prime Coat :- Low porosityProviding and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
405.2.3a:Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
415.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.Case - I By Manual Means(II) Bitumen (S-65)
425.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510A. By Manual Means :- Case - III : Type C(II) Bitumen (S-65)
4375.8.1:Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)