| 1 | Supply installation commisioning and testing of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having Nos of loops to suit minimum 20% extra over the Nos of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’ TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge.Note :- (i)Material and speicific manufacturing should be authorised from original manufacturer.(ii) Local service centre/Distribution Centre should be from the original manufacturer.(iii) Warranty or service support to be provided by OEM with toll free number.Makes: Bosch FPA 4000 Series / Cerberus by Siemens, Edwards EST3, Honeywell Morley Max Series. |
| 2 | (a)Panel 4 Loop Expandable Up to 8 Loop |
| 3 | Supply installation commisioning and testingof addressable multisensor detector with a combination of optical and thermal including base, auto addressing features as required. Detectors should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elemnets in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance wiht EFSG agreement EFSG/F/97/005. EMC safety for detector shall be 50 V/m. shall be EN54/VDS/UL certification. (Detectors without inbuilt isolators may be considered with an additional isolator module after 20 devices) Make: Bosch FAP-440+T+FAA-440, Siemens Cerberus OH921+DB-11, Honeywell Morley HM-PTSE+B501, Edwards SIGA PHD+SIGA |
| 4 | (a) Above False Ceiling |
| 5 | (b) Below False Ceiling |
| 6 | Supply installation commisioning and testing of addressable Heat Detector with fixed and rate of raise feature including mounting base with LED etc complete as required. Each detector should have 2 as per NFPA 72 style 7 wiring requirement (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to eletctromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor electromagnetic interfarence and report to the panelcurrent and average values, EMC safety for detector shall be 50 V/m. shall be EN54/VDS/U: certification. (Detectors without inbuilt isoaltors may be considered with an additional isolator module per detector. (Make: Bosch FAH-440+FAA-440, Siemense Cerberus HI921+DB-11, Honeywell Morley HM-RHSE+B501, Edwards SIGA DHI+SIGA |
| 7 | Supply, installation, testing & commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully complied to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge Makes : (Makes: Bosch FMM-325A-D,Siemens Cerberus HMS-S, Morley MI-MCP, Edwards SIGA 278) |
| 8 | Supply, installation, testing & commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC.Makes :Bosch /Siemens Cerberus / Morley / Edwards |
| 9 | Supply, installation, testing & commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Makes: (Bosch FLM-325-2I4, Siemens Cerberus HTRI-M, Morley MI-DMMI, Edwards EST 3) |
| 10 | Supply, installation, testing & commissioning of Addressable Loop powered sounder with strobe/flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge. Makes :- Bosch /Siemens Cerberus / Morley / Edwards |
| 11 | Supply, installation, testing & commissioning of Addressable Isolation Module complete as required after every 15 detectors and devices conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Makes :- Bosch /Siemens Cerberus / Morley / Edwards |
| 12 | SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make: Bosch/ Siemens Cerberus/ Morley/ Edward. |
| 13 | Supply Installation, Testing & Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Honeywell / Hochiki / R&A |
| 14 | S& F PVC wire for Fire Alarm system with the following sizes of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S. conduit etc. as complete as required. Make Finolex/Havel/Polycab |
| 15 | (a) 2 x 1.5 sq.mm |
| 16 | S&F of PVC conduit pipe of following size ISI marked (medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer -incharge of the work. |
| 17 | (a) 25mm |
| 18 | (b) 50 mm |
| 19 | M&L for mild steel angle irongrill monkey guard protection and MS staging for 1000 ltr water storage tank with any type of structural steel sections, nut bolt, washers, sheets, back plate, xpm mesh, wire mesh, bending cutting in shape, welding, drilling holes, flanges including paintingwith coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed |
| 20 | M&L for plain cement concrete 1:3:6type C-1 using 20 mm graded stone aggregate as in copping of MS structure including necessary form work, weathering slightly roundedor chamferedangles & throating exposed surfaces finished fair and even complete all as specified and directed. |
| 21 | Supplying, laying, jointing, testing and commissioning XLPE insulated (heavy duty) electrical cable up to and including1100 Volts grade with stranded copper conductor, of cross sectional area 4 Sqmm 3 core along the wall/pole/on roof through pipe etccomplete all as specified and as directed. Note :-Copper cable hold with wall / roof / or any brick surface shall be clamped with insulated clamp havingone meter interval between two clamp. |
| 22 | Supply, Laying, fixing & testing CPVC pipe of 20mm nominal bore (internal dia), and outer dia 22.10 mm having 2 to 2.5 mm wall thickness and working pressure 28.14 kg/cm2,ISI -15778:2007, SDR-11 including all connected fittings complete all as specified and as directed. Note :-CPVC pipe shall be clamped with hard surface with one meter interval complete all as specified and directed. |
| 23 | S&F sheet metal enclosure DB, SP 8 way with 200 Amps bus bar double door complete all as specified and directed. |
| 24 | S&F sheet metal enclosure DB, SP 8 way with 200 Amps bus bar double door complete all as specified and directed. |
| 25 | S&F isolator, TPN, 63 Amp complete all as specified and directed. |
| 26 | S&F MCB, SP, 6-32 Amp, C series, complete all as specified and directed. |