Tender For Repair / Maintenance Of Sewage Pump, Sewage Treatment Plants, Dg Sets Of Various Capacities, Servicing And Maintenance Eot Crane And Other Maint E / M Worksat Anand Parbat Mil Stnunder Ge ( N ) Delhi Cantt-10., delhi-Delhi

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Sewage Pump, Sewage Treatment Plants, Dg Sets Of Various Capacities, Servicing And Maintenance Eot Crane And Other Maint E / M Worksat Anand Parbat Mil Stnunder Ge ( N ) Delhi Cantt-10.. Submission Date for this Tender is 26-02-2024. Cranes Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41895644
Corrigendum : Tender For Repair / Maintenance Of Sewage Pump, Sewage Treatment Plants, Dg Sets Of Various Capacities, Servicing And Maintenance Eot Crane And Other Maint E / M Worksat Anand Parbat Mil Stnunder Ge ( N ) Delhi Cantt-10.
Open Tender
Indian
Delhi
delhi
26-02-2024

Tender Details

Repair / Maintenance Of Sewage Pump, Sewage Treatment Plants, Dg Sets Of Various Capacities, Servicing And Maintenance Eot Crane And Other Maint E / M Worksat Anand Parbat Mil Stnunder Ge ( N ) Delhi Cantt-10.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Feb-2024 Corrigendum Other 19-02-2024
2 19-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 89960.0 /-
Tender Value
INR 44.98 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTOF SEWAGE PUMP, SEWAGE TREATMENT PLANTS, DG SETS OF VARIOUS CAPACITIES, SERVICING AND MAINT EOT CRANE AND OTHER MAINT E/M WORKSAT ANAND PARBAT MIL STNUNDER GE(N) DELHI CANTT-10
Sl. No. Item Description
1Comprehensive Maintenance of DG Sets & AMF Panel of Make as mentioned against each DG Sets below including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and attending break down/complaint as and when on required basis, monthly maintenance on regular basis complete with Preventive Maintenance ("B" check) twice a year including replacement of engine oil/coolant, replacement of required necessary spares and replacement of all types of filters, belts along with rectification of minor defects and cleaning of air filters/breather, coolant tank with blower and labour for filling/topping up and tuning of engine for DG set as listed below complete all as specified and directed. Note :-The rates quotedagainst for Ser item No 1.01 to 1.08items shall be applicable for a period of 01 Month.
240 KVA DG Set -01 Nos (Location:- Ranjith Hall, Make: Crompton Greaves)
362.5 KVA DG Set -01 Nos (Location:- Bapa Nagar Pump House, Make: Kirloskar)
462.5 KVA DG Set -01 Nos (Location:- Map Ph-II Pump House, Make: Greaves Power)
5100 KVA DG Set -01 Nos (Location:- MAP Ph-I Pump House, Make: Jackson/Kirloskar)
6125 KVA DG Set -01 Nos (Location:- Amar Vihar, Make: Greaves/Kirloskar)
7160 KVA DG Set -01 Nos (Location:-KLP area, Make: Cumins/Stamford)
8200 KVA DG Set-03 Nos( Location:- Deepak Vihar, Make: Greaves Power)
9NOTES:- (a) After monthly maintenance, the work to be certified by JE (E/M)/Engr-In-Charge on Job Card. (b) Cost of materials and labour as mentioned in below are not included with Comprehensive Maintanance. (c) The Comprehensive maintenance of work shall be done through respective OEMs or their authorised dealers. (d) The contractor shall carry outroutine checking of the complete DG Sets and rectify the minor/major defects noticed immediately.If complaints were not attended within one hours a penalty of Rs 500 per fault per hour shall be imposed over contractor and shall be deduct from his dues.(e) Contractor has to carry out monthly maintenance with examination of suction and exhaust valves for smooth operation of DG Sets. (f)Contractor shall be responsible to monitor the followings of allDG Sets during Comprehensive Maintenance andthe cost of same is deemed to be included in the quoted rate:- (i) Examination and cleaning of fuel injection, nozzles. (ii) Check clearance of suction and exhaust valves and adjust if required, (iii) Changing of oil filters, fuel filters screen filters assy. (iv) Maintenance of coolant level all as directed by the Engineer-in-charge. (v) Change of Hydraulic governor oil(vi) Change of oils (vii) Clean alternator winding in position by forced air and internal surfaces lubricate DE & NDE bearings(viii) Tightining of all nut bolts.(ix) Greasing of all points. (x) Test IR value of alternator winding and recording the readings (xi) Checking of any leaking in fuel & oil lines and rectification of the same. (xiii) Any other check as reqd for efficient running of equipment all as specified & directed by Engr-in-Charge. (xiv) The rates quoted against the above mentioned items is deemed to be included for cost of labour, cost of T & P requiredfor replacement of unserviceable parts and cost of handling / transportation of defective item to & from civil workshop for repair if required. Spares shall be measured and paid separately under respective items.Supply only items labour cost is deemed to be included in this item. (xv)In case of break down, the additional manpower if required will be arranged by the contractor. The cost of the same are deemed to be included in the quoted rate.
10Supply only in replacement of V belts for radiator fan / main shaft/ cam shaft for the DG set of capacity 40 KVAto 200KVA as per existing size and model complete all as specified and direceted.
11Supply only in replacement of fuel filters for the DG set of capacity 40 KVA to 200KVA as per existing size and model complete all as specified and direceted.
12Supply only in replacement of Oil lube filters for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
13Supply only in replacement of Air filters for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
14Supply only in replacement of Lub oil (15W40) for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
15Supply only in replacement of coolant for the DG set of capacity 40 KVA -200KVA as per existing size and model complete all as specified and direceted.
16S&F in repairs forrewininding with super enamelled copper wire of existing size & insulating the field coil assy, replacing bentec assy ofthe self starter assembly 12/24 Voltsand refixing the same after repairs andtesting complete all as specified.
17S&F in replacement ofself starter assembly 12/24 Volts existing size and model andtesting complete all as specified.
18S&F in repairs for lead acid batteries of 12 Volts, 110-150 AH, 22-28 plates,maintenance free type including accesories like terminal clamps, copper cable of required size and length, petroleum jelly and baterry initial charging all as specified and as directed. Make Exide/Amar Raja/Luminious/HBL
19S&F in repairs for battery charger capacity 6/12 Amp, 12/24 Voltsfor DG set complete all as specified and directed.
20M&L for carring out repairs to 12/24Volt dynamo by replacement of carbon brush, electronic regulator , rectifier,windings, bearings reassembling the same and testing complete all as specified and directed.
21S&F in replacement aganist repairs of stop solenoid/ shut off valve of capacity 40 to 200 KVA DG Sets of existing make along with screen Filterincluding wiring connecting to panel circuit, starting and testing on load complete all as specified and directed.
22S&F in repairs of thermostat element alongwith complete assy for DG set connection and testing complete all as specified and directed.
23M&L for repairs and calibration of PT fuel pump as per the calibration procedure and norms as per manufacture"s guide linesfor DG Set of various capacity from40 to 200KVAincluding replacement of worn out and unserviceable "O"rings / shutt off valve/Plungers complete all as specified and directed.
24S&F in replacement of Control assembly forDG Set capacity40 to 200 KVAwith necessary modification to controll wiring, replacement of controll relays , programming with all the parameters for safety protection and running suitable for the existing DG sets. .
25S&F in replacement of necessary control wiring for making the AUTO/MANUAL Mode condition of the existing DG Sets 40 to 200 KVA complete all as specified and directed.
26S&F in replacement ofAutomatic Voltage Regulator (AVR) suitable for DG Set of 40 KVA to 200 KVA capacity including taking out old unserviceable AVR and making all connection, testing for smooth operation complete all as specified and directed.
27S&F in replacement of Magnetic pickup Sensor suitable for 40-200 KVA of exist makeDG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
28S&F in replacement of Oil Pressure Sensor suitable for 40-200 KVA of make exist DG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
29S&F in replacement of Coolant TempetarureSensor suitable for 40-200 KVA of make exist DG set connecting with panel circuit, starting and testing on load complete all as specified and directed.
30Dismantling the unserviceable radiator from DG set of capacity 40 to 200 KVA of exist make andtransporting to contractors workshopfor locating the fault and overhauling & cleaning using air compressor, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, hoses, clamps, clips, etc. and refixing/ reassembling its original position after making proper connections, aligning, testing including transporting back the same to site complete all as specified and directed. (Note :-The rates quoted by the contractor shall deemed to include thereplaced spares / parts, transportation cost from site of installation to contractor"s repair workshop and back.)
31M&L required for cleaning of diesel tank of various capacity DG set inside/ out side oftank complete with drain out DHPP(N) and cleaning tank and applying two coats of synthetic enamel paint (1st grade quality) on out side of tank incl necessary weldings and refilling the DHPP(N) & testing complete all as specified and directed.
32S&F in repairs electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs complete all as specified and directed.
33S&F in repairs of speed control units 40 to 200 KVA DG stes of existing makecomplete all as specified and directed.
34S&F in repairs Auxilary control Contactors side mounting Add On"s (1NO+1NC) as per existing capacity at respective site complete all as specified and directed.
35S&F in replacement of new Power contactor of capacity 360 Amp 4 pole,415 volts with side mounting, MCX type auxilary contacts operable at 220 V, 50Hz including takingdown ofdefective Power contactor from AMF panel complete all as specified and directed.
36S&F in replacement of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified and directed.
37S&Fin replacement of selector switch suitable for 415 volts complete all as specified and directed.
38S&Fin replacament of LED type phase indicator to be fitted on panel (R,Y ,B as per site requirement)as per existing model/ capacity including taking down of old unserviceable one complete all as specified and directed.
39S&F in replacment of digital type voltmeter 0-500volts with selector switch, 3 phase,complete all as specified and directed.
40S&F in replacment repairs of digital type ammeter 0-200/300 Amps with 3 Nos CT coils and selector switch, 3 phase complete all as speicified and directed.
41S&F in replacement for alarm system with complete wiring complete all as specified and directed.
42S&F in replacment of DG setdoor lock and key assembly suitable for exit DG set doors as per existing model complete all as specified and directed.
43Removal of rusted MS sheet at any portion of canopy and supply and fixing of 3.15 mm thick MS Sheet of size 300mm x 300mm with fitting / welding as specified and directed.
44M&L forpainting two coats of synthetic enamel paint of existing colour at site over a coat of red oxide primer for DG sets complete body surfaces complete all as specified and directed.
45M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead by means of bolts, nuts, check nuts and washer of galvanised iron strip 32 x 6mm as earth lead as shown in electrical plate No. 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal od surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate pit, funnel, 20mm bore GI tubing medium grade for watering pipe, 40mm bore medium grade GI pipe for protection of GI earth strip and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) tyep A1 duly reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old unserviceable one complete all as specified and directed. NOTE:The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
46Repair of earth pit including required exacavation, earth work and PCC work to make good damaged/disturbed surfaces of earth pit chamber & making new pit cover of RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate reinforced and lifting handle on RCC cover with 8mm MS bars at 150mm centre to centre both ways incl supply & fixing of wire mesh and funnel including re-connection of earth wire/strip with panel/transformer using GI nut, bolts & washer complete all as specified & directed
47M&L for repair/maint/overhauling long travel mechanism with lubrication LT wheel & gear box, Over hauling hoist mechanism with reduction gear box, over hauling cross travel mechanism with gear box, Testing & commissioning 5 Ton EOT Crane, Replacement of defective any minor parts complete all as specified and directed.
48M&L for painting of complete EOT crane with Golden yellow colour paint including writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high with synthetic enamel paint as per colour scheme all as specified (Make-Rockwell)
49M&L for replacement of PVC flexible cable 1.5 sqmm 16 core copper wire complete all as specified and directed.
50M&L for replacement of Rotary Geard limit switch Ratio 48:1 complete all as specified and directed.
51M&L for replacement of lever type limit switch complete all as specified and directed.
52M&L for replacement of E.M Brake(200mm) Coil 415V, AC complete all as specified and directed.
53M&L for replacement of lubrication gear oil No.68 complete all as specified and directed.
54M&L for replacement of current collector shrouded bus bar type complete all as specified and directed.
55M&L for replacement of 3 pole power contactor type ML4 type complete all as specified and directed.
56M&L for replacement of Hydraulic Thrustor Brake 300mm 34Kg complete all as specified and directed.
57M&L in replacement of damage CT shaft made out of EN8 material medium carbon steeloff size in 80mm x 500mm with various step and key way slot 12mm both side on shaft complete all as specified and directed.
58M&L in replacement of spherical roller bearing off suitable size complete all as specified and directed.
59Comprehensive maintenance inclding preventive and periodical maintenane and servicing of RO systems complete -03 Nos, i.e.500 LPH-01 No & 2000 LPH- 02 Nos capacity. Make of Eukawa & Ion-Exchange with connected motors, UPVC pipe lines, butterfly valves, multi port valves etc,respectively, including servicing/cleaning of all filters/back wash etcin reliable safe and efficient condition through OEM by periodically examining, preventive maintenance of plants, pipe lines, valves for trouble free function as per recommendation and attending breakdown/ complaint as and when on required basis,maintenance on regular basis complete with preventive maintenanceincluding replacement of UPVC pipes (different sizes) short lengths upto 5 mtrs, fittings, flanges with nut and bolts, pressure gauges, replacement of required necessary fittings alongwith rectification of defects complete all as specified and directed.all as directed. Notes :- (i) The contractor shall carry out routine checking of the complete plants and rectify the any defects noticed immediately (ii) Treated water TDS should be maintained less than 100mg/l and as directed, submit he monthly water test report of treated water. (iii) The rates quotedagainst for this item shall be applicable for a period of 01 Month. (iv) Rates quoted aginst the above mentioned work wise items are required of efficient working of plant are to be included in the job . (v) Unserviceable and consumable parts will be measured and paid seperately unde relevent items as mention in below. (vi) If complaints were not rectified within 04 Hrs of intimation, the following penalities will be imposed and deducted from contractors dues :- (a) Rs 1500/- per complaint for not attending the complaint and keeping pendig 04 Hrs to 12 Hrs/ per complaint. (b) Rs 3000/per complaint for not attending the complaint and keeping 12 hrs to 24 hrs/per complaint.
60Replacement in repairs membrane high pressure, 500 LPH.Make DOW/Hydronautics/ CSM
61Replacement in repairs membrane high pressure,2000 LPH.Make- as per sample
62Replacement in repairsfor sediment(sand and silt), dirt and rust particles, high efficiency, low pressure drop, removal up to 5 micron filter cartridges suitable 500& 2000LPH capacity makes as per existing all as specified and directed.
63Replacement media in sand filter (gravel,pebles,fine sand).
64Replacement activated carban in barban filter.
65Supply only RO antiscalent high PH for membrane cleaner/water treat ment chemical (Make- Ion Exchange(India) Ltd).
66Replacement in repairs Rotameter suitable for 500/2000LPH capacity RO system. Make as per sample.
67Replacement in repairs of UPVC pipe 20 to 40mm dia with fitting complete suitable for RO systemas per sample.
68Replacement in repairs of membrane housing suitable for 500 LPH capacity RO system of Eukawa Make .as per sample
69Replacement in repairs of membrane housing suitable for 2000 LPH capacity RO system of Ion Exchange Make .as per sample
70Replacement in repairs of housing bowl suitable for 500 & 2000 LPH capacity RO system, Make .As per sample.
71Replacement in repairs of LT Relay,230V AC supply suitable for 500 & 2000 LPH capacity RO systemMake .As per sample.
72Supply and fixing in reapirs of multi port valves fixing at sand filter and carbon filter vessles all as specified and directed. Makes as per sample.
73S&F,testing and commissioning high pressure pumps for RO plant, vertical type having speed 2780 RPM, 230 V, 2HP, class F insulation, eff 76% complete with fixing necessary accessories including taking down old unserviceable deposit to store yard complete all as specified and as directed. Make : CRI/Crompton/Kirloskar.
74S&F,testing and commissioning self priming regenrative pumps for RO plant, Mini star model having speed 2780 RPM, 230 V, 1HP, class B insulation,size 25 x 25mm, head 6-45 mtrs, dis range 50 LPMwith fixing necessary accessories including taking down old unserviceable deposit to store yard complete all as specified and as directed. Make : CRI/Cropmton/Kirloskar.
75S&F in repairs for Rotational moulded polye- thylene water storage tanks100 Ltrs capacity (cylindrical vertical with closed top in white colour transparent type for using antiscaling chemicals for RO plants) hoisted and fixed in position all as specified and directed.
76M&L for disconnection electrical and water connection of the raw water feed monoblock pumpset with motor and base plate and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto3 HP.Note:- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
77M&L for disconnection electrical and water connection of the high presuure feed pump, multi stage centrifugal type and transporting to work shop opening carefully and rewinding the burnt out winding, replacement of bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto3 HP. Note:- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
78S&F in repairs for antiscalant dosing unit capacity upto 6 LPH @ 3.5 bar incl inlet and outlet flexible pvc pipes all as specified and directed.
79S&F in repairs pressure gauges for monitering of flow meters all as specified and directed.(Makes as per sample)
80Testing of treated water of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved. (a) Carrying out minimum essential testing of water as per IS 3025mandatory for chemical, odour, PH Value TSS BOD COD residual chlorine total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms as below:- Rest of the characterstied of the treated water shall be as per IS : 3025 Note 1:- rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required. (ii) To and fro transportation charges for collection of sample
81(i) TSS: < 10 Mg/ ltrs (ii) BOD : < 10 Mg/ ltrs (iii) COD :< 150 mg / Ltrs (iv) PH : 6.5-8.5 (v) Total coliform : ,< 100 MPN/100 Ml (desired Nil) (vi) Residual CI > 1 mg/ Ltr Rest of the characterstied of the treated water shall be as per IS : 3025 Note 2 - Rates quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and from transportation charges for collection of sample Note 3 - Incase contractor fails to provide monthly test report a penalty of Rs 3000/- per test report shall be recovered from the contractor dues.
82Testing of Sewage sludge water as per revlevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value TSS BOD COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water:- Note 1 - Rates quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required(ii) To and fro transportation charges for collection of sample
83Supply & mixing of Sodium Hypo Choloride having 10 % content complete as as specified and directed.
84Supply & mixing of Poly Aluminium Choloride 100 % purity complete as as specified and directed.
85Supply & mixing of Poly Electrolite 100 % purity complete as as specified and directed.
86Supply & filling compressor oil 460 Make : Castrol complete as as specified and directed.
87Material and labour in replacement of quartz silica sand 32-64 grade complete as as specified and directed.
88Material and labour in replacement of quartz silica sand 16-32 grade complete as as specified and directed.
89Material and labour in replacement of quartz silica sand 8-16 grade complete as as specified and directed.
90Material and labour in replacement of quartz silica sand 4-8 grade complete as as specified and directed.
91Material and labour in replacement of activated carbon IV 1000 complete as as specified and directed.
92Material and labour in replacement of FEB (MBBR) Media suitable for STP make as per sample complete as as specified and directed.
93Taking out complete pebbles from the bottom upto the depth of 0.6 Mtr of the filter of size 1800mm dia and 2300mm height and refilling the same pebbles after washing and cleaning thoroughly complete as as specified and directed.
94Periodical Cleaning of sewage well as capacity (upto 5mtrs dia and 9 mtrs depth) cum and removing of settle down sewage sludge cum mud/De-Silting etc. all as required at site anddirected atAnand Parbat Mil Stn (KLP location, MAP Ph-I) and COD area complete as as specified and directed. Note:-The rate quoated by the tenderer is deemed to be included in the unit rate of the following :-
95Diesel driven pump set of appropriate capacity not less than 5/7.5 HP with operatorincluding necessary POL required at site for de-watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes
96Tractor mountedstorage tank of appropriate capacity not less than 1KL with driver directly collected from the soak well and disposing the same to the location out side of Military contonement where as approved by PCB and also liase with Delhi Muncipal corporation board as directed.
97Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary tarpaline ) and depositing the same to the location where approved by PCB or as directed.
98Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited out side of Military contonment and out side location as mentioned above.
99Appropriate qty of phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank and all as directed.
100Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed.
101M&L for cleaning oftreated water tank atAnand Parbat at KLP loaction STP of storage capacity of water 50000 gallons, filter feed tank of capacity 63 cum and chlorine contact tank of capacity 17 cum thoroughly by removing mud, grits etc from the tankby following method :-
102(a) Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manuallyat a distance not exceeding 50 mtr all as directed. (b) Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
103Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as directed.
104Supply and laying including taking up MS water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends,elbow, tees, short pieces, connectors, back nuts,diminishing pieces,caps,plugs, threaded flanges and unions,etc)and fixing complete with clips,wall hooks,wooden plugs,or laying in trenches etc.,also cutting,screwing and waste and for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
10580mm dia
10650mm dia
10740mm dia
108Supply and laying GI water tubing heavy duty with wlded joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, flanges and unions,etc)and fixing complete with clips,wall hooks, wooden plugs, or laying in trenches, etc., also cutting, screwing, welding and waste end for making forged bends on piping as required at site including taking down the existing pipe line with fitting etc of following sizes:-
10940mm dia
11050mm dia
11180mm dia
112100mm dia
113Supply and fixingbutterfly valves iron body screwed down high pressure with iron wheel head/ long shank and cup butterfly type screwed both ends for iron pipe including taking out unserviceable valve for the following sizes:-
11440mm dia
11550mm dia
11680mm dia
117M&L for spray painting two coats of synthetic enameled paint of specified colour after preparation of surface and writing letters and numbers complete of complete sewage treatment plant capacity 100 Cum/day with equalization tank, raw sewage pumps, MBBR reactor, Chlorine tank, filter feed pump, Dual media filters, RCC treated water tank, treated filter pumps, sludge drying beds, oil free blowers and accessories complete all as specified and directed.
118M&L for disconnection electrical and water connection of the monoblock pumpset with motor and base plate and transporting to work shop opening carefully and replacement of winding, bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of motors upto7.5 HP. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
119M&L for disconnection electrical and water connection of the compressors and transporting to work shop opening carefully and replacement of spare parts bushes, gland packing, ball bearing, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed for the size/ capacity of up to 110 M3/hr. Note :- Rate includes transportation of compressor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
120M&L for lifting/lowering of non clogging submersible pump and motor capacity up to 7.5 HPfrom Sewage well after disconnecting electric and water connection of any make and any size capacity under any of chain pulley block or manually appropriate length upto 10m after opening the socket and pipe replacement of winding, bushes, gland packing, ball bearing, thrust bearings, sand guard plate, GM impellers, rubber gasket nut and bolt and replacing the required spares parts as per existing complete re-fixing its in original position and making out all electrical and water connection and testing complete all as specified and directed.
121Supply and fixing in reapirs of multi port valvesfixing at mediafilter vesselses for STPall as specified and directed. Makes as per sample.
122S&F in repairs for dosing unit capacity electronic metering pumps for chemicals dosing system for STP including inlet and outlet flexible pvc pipes all as specified and directed.Makes as per sample
123M&L in repairs for cross arms, bracings, supports, clamps, angle iron, flats, ladders and back plates fabricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed.
124M&L diamantling, opening of automatic voltage stabilizer 200 KVA rating (300-480 Volts), out put 415 V including disconnecting electric connection complete all as directed.
125M&L for repairs taking up deemer assembly complete by carefully by manual chain pulley block and replaceemnt of burnt wiinding coil with existingsize and gauge of copper winding wire inclduing transportation charges from site to work shop and back complete all as directed.
126M&L for replacement of motor assembly for moving of 20 Kg load complete all as directed.
127M&L for replacement of carbon brush (03 sets of 03 Nos each) complete all as directed.
128M&L for repairs of internal wiring and servicing complete all as directed.
129M&L for in repairs machine pressed precast conctete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade including sand filling including dismantling complete all as specified and directed.
130Demolition of PCC in ground floor and paving not exceeding 15 cm thickness (below or above ground level)complete all as specified and directed.
131M&L for broken stone boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, wateredand rammed to a true surface including demolition complete all as specified and directed.
132Sand filling under floors or in foundations including watering and consolidation complete.
133Taking up existing DI Pipe sewage water pumping system line 80 to 150mm bore incl fittings and relaying, jointing and testing of same in to trenches in position after cleaning and removal of scale/blockage complete for the following sizes Note :- Earth work, Lead joint and rubber tyton joints shall be measured and paid separately under relevant items.
134Material and labour for DI specials of any size such as tees, bends of any sizeand radius, tapers, collers, tail pieces, caps and plugs etc including takinng down unserviceable complete all as specified.
135M&L for rubber gasket Joint (Tyton Joint) with jointingmaterial for DI pipe of 80 to 150mm bore including taking down unserviceable complete all as specified and directed.
136Earthing with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthingtest point all as specified or indicated,including testing on completion. NOTE:The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
137S&F earth continuity conductor or main earth lead fixed to wall on batten or recess or chess or buried in ground drawn in conduit/pipe or fixed to the pole or any other situation for loop earthing etc as required32mm x 6mm dia galvanised iron strip complete all asspecified and directed.
138S&F in repairs Addressable manual call point resettable type complete all as specified and directed.
139S&F in repairs weather proof hooter complete all specified and directed.
140M&L in repair for two single core (submain) PVC insulated cable with 1.5 sqmm nominal cross sectional area 1100 V, stranded copper conductor, multistranded, and one single core green PVC insulated 1.5 sqmm stranded copper conductor earth continuity cable drawn through metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete
141Dismantling and taking out unserviceable Hose box along with hose reelof any size with connected accessories complete all as specified and directed
142S&F Canvas pipe reel 15m long hose confirming to IS 636 complete with male and female coupling confirming to IS 903along with hose box all as specified and as directed
143M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm2 core complete all as specified.
144Excavation in tranches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for cable tranches and getting out in soft/ loose soil complete all specified and as directed.
145Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25cm in soft loose soil complete all as specified and as directed .
146Removing excavated metarial to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and as directed.
147Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed
148Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
149S&F GI tubing light grade 40mm dia for protection of cable passing through duct / road crossing / on pole / on wall tc including all fitting and fixing arng like clamps made out of 25mm x 3mm flat iron and nut bolts all specified and as directed
150M&L for cement concrete with PCC 1:2:4 typeB-1 (using 20mm graded crushed stone aggregate) including necessary from work complete including demolition and making good as per existing all as specified and as directed.
151Supply, installation, testing and commissiong of addressable fire alarm panel with loop sounder and manual call point with programming of all devices all as specified and as directed
152Supply and fixing 25mm dia rigid steel conduit, welded and fixing to walls, roof all as directed.
153M&L for rewinding of electrical motor 10 HP with super enameled copper winding wire of suitable size not less than original after cutting and taking out old winding complete with all insulation material such as Colton top varnishetc of centrifugal pump set motor all as specified and directed for the following sizes. Note :- Rate includes transportation of motor from the place of installation for repairing and reinstalling the same on existing foundation & testing & commisioning.
154M&L for taking down carefully storge type water cooler of any type/make, capacity (40/80 ltrs, 60/120 ltrs) including discoonection of electric/water supply connections from various locations, servicing with washing, removing of dust particles, cleaning of condenser coil by blower, painting the outer body (including replacement of corroded sheet with new one) writing letters mentioning the MES Ser No, checking of complete wiring, tightening of loose wire connections with proper Lugs / clips. renewal of defective wiring and connector terminal, proper setting of the thermostat and other electrical / Refrigerant controls and refixing to its original position, testing for proper functioning / cooling effect complete all as specified and directed.
155M&L for taking down carefully Refrigerator/Deep freezer of any type/make, capacity (165/185/310/320 Ltrs) including discoonection of electric supply connections from various locations, servicing with washing, removing of dust particles, cleaning of condenser coil by blower, painting the outer body (including replacement of corroded sheet with new one) writing letters mentioning the MES Ser No, checking of complete wiring, tightening of loose wire connections with proper Lugs / clips. renewal of defective wiring and connector terminal, proper setting of the thermostat and other electrical / Refrigerant controls and refixing to its original position, testing for proper functioning / cooling effect complete all as specified and directed.
156S&F in replacement of starting capacitor/running capacitor, suitable range, 240 volt including making connection complete all as directed.
157S&F in replacement of relays suitable for water cooler/freezer all as directed .
158S&F in repairs for overload protection coil230 Volts for any type water cooler/freezer, ISI marked complete all as specified and directed.
159S&F in replacement of thermostate switch of suitable temperature range ISI marked suitable for water cooler/freezer of any make/type complete all as specified and directed.
160M&L for charging of refrigerant R-22 / R-410A or any other recommended refrigerant gas in water cooler/freezer/Refrigerator including detecting leakage and rectify the leakage with proper brazing and testing on full load complete all as directed.
161S&F for replacement of capillary tube and stainer for any type freezer/water cooler of capacity complete all as specified and directed.
162M&L for replacement of hermatically sealed reciprocating/rotary type (as per existing) compressor unit, including taking down unserviceable complete for watercooler/freezer with charging of refrigerant complete all as specified and directed.
163S&F in repairs for Printed Circuit Board for control unit for any type,Model suitable for water cooler/ freezer /Refrigerator as per existing and same make ISI marked, including taking down unserviceable complete all as specified and directed.
164M&L for replacement of fan blower motor copper wound for water cooler/freezer with same rating 220/230 volts, including taking down unserviceable complete all as specified and directed.
165S&F for push type water tap made of CP brass suitable for water cooler capacity 80/150 ltrs capacity including taking out old unserviceable tap complete all as specified and directed.
166S&F for 60 cm long PVC connector including taking out old unserviceable PVC connector complete all as specified and directed.
167S&F for CP angular stop cock with wall flange including taking out old unserviceable stop cock complete all as specified and directed.
168S&F for drain tray for water cooler of any capacity including taking out unserviceable drain tray complete all as specified and directed.
169S&F for head cover gasket for water cooler of any capacity including taking out unserviceable head cover gasket complete all as specified and directed.
170S&F for drain pipe flexible type of existing dia meter for water cooler of any capacity including taking out unserviceable drain pipe complete all as specified and directed.
171S&F for magnetic door gasket screw for refrigerator of any capacity including taking out unserviceable one complete all as specified and directed.
172S&F in replacement of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with out put voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and directed.
173S&F in repairs of desert/Air cooler 25"x25"x32" body made out of 18 SWG GI sheet duly powder coated paintwith 500mm sweep copper wound fan motor kit 145 watt ISI marked 1400RPM, 230 volt AC and tank capacity not less than 100 ltr fitted in existing window with 6mm thick plywood to cover the gap and old unserviceable desert cooler deposited in E/M Store yard .
174M&L for painting of desert coolers with synthetic enamel paint of approved colour, with spraying machine, after cleaning, scrabing, preparation of cooler body with set of blades, inner/outer surface area complete all as specified and directed.
175S&F in replacement of cooler fan motor kit for desert coolers of capacity 500mm sweep, 220-240 Volts,1Ph,145 Watts, 1400 RPM incl fixing arrangement with claming/bracing supports as per site requirement complete all as specified and directed. Make :- Khaitan/CG/Bajaj
176S&F in repairs plastic submersible pump suitable for 18 to 22 inch, 18 watt, 240 volts for desert coolers complete all as specified. As per sample. Make :- Khaitan/Max/Bajaj
177S&F in replacement 6mm thick plywood sheet (ISI marked) waterproof fixed in window including cutting as desired size for passing air of desert cooler complete all as specified and directed.
178S&F in replacement of desert cooler pad (set of three) made out of wood wool etc suitable for desert cooler of any size complete all as specified and directed.
179S&F in replacement desert coolers side panels of size suitable of cooler body size (25"x25"x32")made out of 20 SWG MS sheet with wiremesh frame complete and grill duly painted with two coat synthetic enameled paint over one coat of red oxide inside complete all as directed.
180S&F in replacement PVC flexible pipe of high density for 15mm bore with necessary pvc bends,straights complete for desert cooler of any size complete all as specified and directed.
181M&L in replacement of Plug top, 3 pin, 05 amps, 230 volt.
182M&L for cooler fan blade (metal body) suitable for 500mm sweep for cooler fan complete all as directed. (Make as per sample)
183Rewinding of burnt winding of the cooler fan up to 500mm dia with matching gauge and turns of superenamelled copper wire leathenic paper, glass sleeves etc including varnishing, heating the windings as per manufacturer design and reassembling the same complete testing all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail