Tender For Provn Of Conversion For Lt Oh Lines To Underground Cable In Perimeter And Security Light With Allied Work At Reasi Mil Stn And Chasana Under Ge Nagrota, Nagrota-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provn Of Conversion For Lt Oh Lines To Underground Cable In Perimeter And Security Light With Allied Work At Reasi Mil Stn And Chasana Under Ge Nagrota. Submission Date for this Tender is 08-03-2024. Overhead Line Tenders in Nagrota Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41894462
Corrigendum : Tender For Provn Of Conversion For Lt Oh Lines To Underground Cable In Perimeter And Security Light With Allied Work At Reasi Mil Stn And Chasana Under Ge Nagrota
Open Tender
Indian
Jammu And Kashmir
Nagrota
08-03-2024

Tender Details

Provn Of Conversion For Lt Oh Lines To Underground Cable In Perimeter And Security Light With Allied Work At Reasi Mil Stn And Chasana Under Ge Nagrota

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Feb-2024 Corrigendum No 01 Date 04-03-2024
2 17-Feb-2024 BOQ Corrigendum BOQ 04-03-2024
3 04-Mar-2024 Corrigendum No 03 Other 08-03-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 156250.0 /-
Tender Value
INR 87.50 Lakhs /-

BOQ Items

Name of Work : PROVN OF CONVERSION FOR LT OH LINES TO UNDERGROUND CABLE IN PERIMETER AND SECURITY LIGHT WITH ALLIED WORK AT REASI MIL STN AND CHASANA UNDER GE NAGROTA
Sl. No. Item Description
1Dismantling and taking down old unserviceable ACSR conductor of any type/size complete all as specified and directed by Engineer in Charge.
2Dismantling and taking down old unserviceable insulator any type and any size complete all as specified and directed by Engineer in Charge.
3Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for laying of cable or pipes, trimming the sides, forming bottom surfaces to required level, n.exc 10sqm on plan and getting out, complete all as specified and directed.
4Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 20 cm thick complete all as specified and directed.
5Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete all as specified and directed.
6M & L for dry sand cushioning to under ground cablelaid in trenches for laying of HT/LT UG cables 8 cm wide before laying the cable and 15 cm after laying and punned down to a depth of 10 cmas per MES SSR Part-I (2009) all as specified anddirected. Note: Punned thickness shall be measured and paid to the contractor.
7M&L for sub class ‘B brick, designation 75 for cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
8Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 95 Sqmm 3.5 core complete all as specified and directed .
9Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 50 Sqmm 3.5 core complete all as specified and directed .
10Supply,laying, jointing and testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty 1100 volts grade in trenches/on surface of wall/ in GI pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc of cross-sectional area 25 Sqmm 3.5 core complete all as specified and directed .
11S&F Rigid non-metallic PVC conduit external dia 20 mm fixed to street light pole for connection, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed.
12S&F copper wire with 3 core 2.5 sqmm PVC insulated (flexible)1100 volts grade, connected from junction box to street light complete all as specified and directed.
13Supply and Fix, shock proof, rustproof, termite resistant, weather proof,fire retardant - Class FV-0 as per IS:11731 Part-II or V-0 as per UL-94, high heat distortion temperature (200°C as per IS:10192), pole mounted Junction box, minimum size(Internally) 250 mm (H) x 200 mm (W) x 105 mm (D), including provision of 01 (One) No. electrolytic aluminium bus bar, 10 Amps, supported on non-hygroscopic fibres and brass screws for mounting with and including 01 (One) No. miniature circuit breaker (MCB) single pole, 240 Volts, 10KA, 6 Amps complete all as specified and directed.
14M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt startingfrom ground below earth plateupto 150mm above GI plate in alternate layersconnected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
15S & F Bracket for street light fitting made out of tubing 50 mm dia, med grade 2" x 1-1/2" 135 degree bend with cutting, welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings complete all as specified and directed by Engr-in-charge.
16Supply and fixing GI tubing 40 mm dia light grade laid under floors/road crossing, fixed to walls and ceiling as cable protection pipe all as specified and directed by Engr-in-Charge.
17Supply and fixing GI tubing 50 mm dia light grade laid under floors/road crossing, fixed to walls and ceiling as cable protection pipe all as specified and directed by Engr-in-Charge.
18Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
19Supply and Fix, Astronomical Time Switch with enclosure all as per Cat No. "T2DDT7" with3 Pole Power Contactors, Type MNX 25, AC3 Rating 25 A and AC1 Rating 45 A, all as per Cat No. "CS94110" of Make "L&T or equivalent as per list of makes given in particular specifications complete all as specified and directed.
20Supply, fixing and erection truly in vertical position steel tubular swaged pole type 410 SP-31 (09 mtr long) with 300x300x6mm mild steel plate continuously welded to pole , finial taper plug, bolts, nuts and screws complete all as specified and directed including painting with black bituminous paint internally and externally with anti corrosive paint in alternate black and white strips 30 cm each up to 1.5 mtr height from top edge of concrete and remaining pole with two coats of aluminium paint over a coat of red oxide primer including writing the number etc complete all as specified and directed by Engineer-in-charge. Note: Excavation and Earth work, PCC in foundation and coping shall be measured and paid separately.
21S&F commissioning and testing of outdoor cubical type LT Feeder pillar box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V, 3 phase, 4 wire 50Hz,AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell having TPN aluminium busbar mounted in porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring, Powder coatedcomplete all as specified a nd directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel.Angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
22Incoming:- (a) MCCB 200 Amp 4 pole35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No (b) Alum bus bar 200 Amp TPN - 01 Set (c) Digital Multifunctionmeter showing:- V, I, PF, Hz etc with suitable CT - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a)MCCB 160 Amps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand)- 03 Nos (b)MCCB 4 Pole, 100 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No (c)MCCB 4 Pole, 63 Amp, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting , Ics = 100% of Icu (Make - Siemens/Legrand)- 01 No
23M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt startingfrom ground below earth plateupto 150mm above GI plate in alternate layersconnected to galvanized earth strip 25x4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified includingprovision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
24S&F commissioning and testing of outdoor cubical type LT Feeder pillar box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell, having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring, Powder coatedcomplete all as specified and directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel.Angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
25Incoming:- (a) MCCB 160 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 03 Nos (b) Alum bus bar 200 Amp TPN - 01 Set (c) Digital Multifunctionmeter showing:- V, I, PF, Hz etc with suitable CT - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a) MCCB 100 Amps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu(Make - Siemens/Legrand)- 01 No (b) MCCB 63 mps capacity 4 pole, 25/27 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 01 No
26Material and labourfor PCC 1:4:8 type D-2using 40mm graded stone aggregate as in base of pole, coping above ground level etc complete all as specified and directed.
27Material and labourfor PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of pole complete all as specified and directed.
28M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt startingfrom ground below earth plateupto 150mm above GI plate in alternate layersconnected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified includingprovision of 40mm dia medium grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed by Engr-in-charge.
29S&F commissioning and testing of CPRI approved outdoor cubical typebus bar chamber box of size 0.5Mx0.8Mx0.60M depth,(HxBxD) outdoor type alongwith one incoming MCCB 100 A 4 Pole 25 KA factory fabricatedmade out of CRCA sheet of 3.15 mm thick ,fully enclosedand angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openabledouble door shutter, dust and vermin proofand rear openingcomplete with locking arrangement, having a system of bus barsof aluminiumof suitable size of 100 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415volts, AC, system including provision of suitable cable glands, duly powder coated complete all as specified and directed.
30S&F commissioning and testing of outdoor cubical type LT Feeder piller box as per CPRI approved, IP-54 Protection for outdoor shell suitable for 415V,3 phase, 4 wire 50Hz, AC supply system fabricated from CRCA powder coated totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell and 2mm thick for inner shell having MS section not less then 40x40x6 mm thick having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with suitable glands including control wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB,Powder coatedcomplete all as specified and directed by Engrineer-in-Charge. Note:- Feeder piller box shall be mounted on 40x40x6 mm thick angle iron embedded in PCC 1:2:4,type B-I (Using 20mm graded stone aggregate) 30 cm deep and 45 cm above ground level. Danger notice plate should also be mounted on panel.angle iron shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer
31Incoming:- (a) MCCB 160 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal & Adjustable Magnetic type setting Ics = 100% of Icu (Make - Siemens/Legrand) - 03 Nos (b) Alum bus bar 200 Amp TPN - 01 Set (c) Multifunction digital meter (consisting of Voltage 0-500 volts, Current 0-300 Amp, PT and CT(Frequency, PF, kWh, kVA parameter) - 01 set (d) Indicator lamp LED type (RYB) complete - 01 set Outgoing:- (a) MCCB 125 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal Magnetic type setting Ics = 100% of Icu(make- Siemens/ Legrand) - 01 No (b) MCCB 63 Amps capacity 4 pole, 35/36 KA, Adjustable Thermal Magnetic type setting Ics = 100% of Icu(make- Siemens/ Legrand) - 01 No
32Note:- Schedule of credit Rs. 20,000.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.