New Delhi Municipal Council-NDMC has published Supply Installation Testing Commissioning & Repairing Of Variable Frequency Drive Including Other Hvac Works For Ac Plant Talkatora Indoor Stadium Under Bm-I ( E ) Division. Submission Date for this Tender is 06-02-2024. Industrial Drive Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying, fixing, testing and commissioning of following valves in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified including buy back for old material. 200MM dia |
2 | Repairing and Servicing of Variable Frequency Drive which shall be capable of operating on the AC Supply Voltages applicable to the end site with suitable tolerance for variations in the incoming mains power supply. The applicable supply voltage range must meet one the below: 380-480V A + 10%. VFD’s must be capable of continuous operation with the connected load with up to 3% voltage imbalance between the incoming phases. VFD’s shall be capable of operating with a mains supply frequency range of 50-60 Hz + 2%. The VFD shall be capable of variable frequency, variable voltage output in the range 0-50Hz and 0-45Hz Supply Voltage. VFD’s after repairing should include protection features to ensure that the motor may not operate in an overloaded condition which may cause damage to the connected motor. It shall be capable of controlling the motor with a constant or variable torque output characteristic in order to operate the desired load. Selection between constant and variable torque operation should be easily selectable by parameters within the VFD. (Make: ABB15KW Model No. ACS550-01-031A-4) |
3 | SITC of Variable Frequency Drive of following capacity which shall be capable of operating on the AC Supply Voltages applicable to the end site, with suitable tolerance for variations in the incoming mains power supply. The applicable supply voltage range must meet one of the below: -380 – 480 V AC ± 10%. VFD’s must be capable of continuous operation with the connected load with up to 3% voltage imbalance between the incoming phases. VFD’s shall be capable of operating with a mains supply frequency range of 50 – 60Hz ± 2%. The VFD shall be capable of variable frequency, variable voltage output in the range 0 – 50Hz and 0 –415 Supply Voltage. VFD’s must be available with a minimum IP20 rating and should include protection features to ensure that the motor may not operate in an overloaded condition which may cause damage to the connected motor. It shall be capable of controlling the motor with a constant or variable torque output characteristic in order to operate the desired load. Selection between constant and variable torque operation should be easily selectable by parameters within the VFD including removing of existing VFD, Programming & Synchronization of the software with the existing VFD modules for management of all parameters as running in existing case including buy back for old material (Make: ABB15KW Model No. ACS550-01-031A-4) |
4 | Supplying, Fixing, testing and commissioning of volume control dampers in supply air duct/main branch and return air path as and where required of following size. i.e 1100mm X 1200mm X 150mm including buy back for old material. |
5 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required including buy back for old material. |