}

Tender For Procurement Of Equipments For Cord Blood Bank, Kolkata-West Bengal

Health And Family Welfare Department has published Tender For Procurement Of Equipments For Cord Blood Bank. Submission Date for this Tender is 24-02-2024. Tanks and Cylinders Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

41885120
Tender For Procurement Of Equipments For Cord Blood Bank
Tender
Indian
West Bengal
Kolkata
24-02-2024

Tender Details

Procurement Of Equipments For Cord Blood Bank , Specification For Vapour Phase Liquid Nitrogen Storage Tank: 1. Cryo Tank Exterior Dimensions (H X W X D): (48 – 70) X (30 - 35) X (30 – 35) Inch. 2. Interior And Exterior Material Of Liquid Nitrogen Vapour Phase Storage Tank Must Be Made Of Cryogenic Stainless Steel And The Tank Should Be Vacuum Insulated To Maintain The Ultra-Low Temperature For Long Duration. 3. The Inner Turn Table Must Be Made Of Stainless Steel. 4. Under Platform/ Turn Table Liquid Nitrogen Capacity: 50 – 60 Litres. 5. Capacity: 1200 – 1350 Number Of Stem Cell Bags (Size-25Ml) Can Be Preserved In Slots Of “Frames/Tower” Containing 6-7 Units Per “Frames/Tower. 6. Cryo Tank Neck Diameter: Should Be Such That Sample Placement Can Be Done Easily And Easy Quadrant Change Can Be Done. 7. Ergonomic Lids. 8. Built-In Workspace With Lockable Lid Of Storage Tank For Sample Protection. 9. Automated Temperature Monitoring And Microprocessor-Based Liquid Nitrogen Level Control. 10. User Friendly During Putting In Or Taking Out Of The Samples. 11. Real-Time Liquid Nitrogen Level Monitoring System Must Be Present. 12. Stable Lid Opening Temperature With Advanced Temperature Monitor And Alarms. 13. Automated Fill Of Liquid Nitrogen Must Be There When Level Of Liquid Nitrogen Is Below Specified Set Level And Automated Stop System When Desired Set Level Is Reached. 14. De-Fog Switch For Easy Sample Location. 15. Hot Gas Bypass Must Be There To Keep Warm Nitrogen Gas From Impacting Samples During A Fill Cycle. 16. Battery Backup Must Be There For Data Recording During Power Failure. 17. Minimum Of 2 (Two) Temperature Sensors One In Top And Other At Bottom With A Resolution Of 0.1 Degree C With Additional One Port For Independent Monitoring. 18.Level Measurement –A Resolution Of 0.1Inch Must Be There. 19.Calibration And Adjustability Of Parameters – By Touch Screen Method. 20. Safety Relief Valve Must Be There. 21. Static Evaporation Rate – Should Be As Little As Possible Preferably 0.5 Lit/24 Hours Or Typically 1-2% Of The Liquid Capacity Of The Vessel Per 24 Hours. 22. Provision For External Temperature Probe. 23. Inbuilt Data Logging / Data Storage Capacity(Memory) – Number Of Events – 30,000 Or More , Temp A Record – 30,000 Or More,Temp B Record – 30,000 Or More, Level Record – 30,000 Or More. 24. Data Download Cable And Software Should Be Provided Along With For Data Transfer. 25. Data Capture Interval Must Be Adjustable According To User Requirement From Minutes To Hours, I.E Data Of Temperature And Ln2 Level. 26. Password Security – Must Be Present. 27. Alarms For – Low Level, High Level, Low Temp. , High Temp. , Lid Open, Open Sensor, Calibration Alarm, Ln2 Use Alarm. 28. System Should Have Option For Remote Monitoring System Which Can Collect Equipment Parameters Like -Temperature, Liquid Nitrogen Level. 29. Power Supply: 230V, 50Hz Single Phase. , 30. Display Screen Should Be Clearly Discernible. 31. Cryo Preservation Tank Must Be Provided With Switch For Manual Filling Of Ln2. (Alternate Filling Option Should Be Provided). 32. The Inside Of Storage Tank Should Have Provision (Slot) For Manual Measurement Of Liquid Nitrogen Level By External Measuring Scale. 33. Cryo Tank Must Have Castor Wheel For Easy Movement Which Should Be Lockable. 34. Cryo Preservation Tank Must Come With Steel Stair Case Or Similar Way-Out For Easy Handling Of Preserved Material. 35. Vacuum Insulated Flexible Stainless Steel Hose Of Suitable And Workable Length Should Be Included. 36. Prompt And Efficient After Sales Service Must Be Provided Within 24-48 Hours. 37. Have To Provide Iq, Oq, Pq Certificate. In-House Pq Is Compulsory For Material Acceptance Or Rejection. 38. Safety And Standard Certificate: Us Fda / European Ce (4 Digit Notified Body) /Bis. 39. The Company Should Have 3 (Three) Years Presence In The Market. 40.Accessories Should Be Included – A) Vacuum Insulated Transfer Hose Pipe 4 – 5 Ft Length – Qty 1(One) No. B) Cryo Gloves, Water Proof, Mid-Arm /Medium – Qty 2 (Two) Pairs. C) Cryo Goggles – Qty 1 (One) No. D) Liquid Nitrogen Dip Measuring Scale – Qty 1(One) No. E) Cryo Claw- Qty-1(One) No. 41. Fully Loaded Sample Free Tank Will Retain Temperature Of Not Warmer Than Minus 180°C For 15 Days. 42. Lifetime Warranty

Key Value

Document Fees
Refer document
EMD
INR 150000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail