Tender For Supply, Installation, Testing And Commissioning Of 12 Meter High Mast With 6*200 Watt Led Flood Lights Infront Of Kunnukara Juma Masjid, Ward 10, Kunnukara Gramapanchayath Under Mplads Sri Hibi Eden Mp, kunnukara-Kerala

United Electrical Industries Limited has published Tender For Supply, Installation, Testing And Commissioning Of 12 Meter High Mast With 6*200 Watt Led Flood Lights Infront Of Kunnukara Juma Masjid, Ward 10, Kunnukara Gramapanchayath Under Mplads Sri Hibi Eden Mp. Submission Date for this Tender is 06-02-2024. Halogen Light Tenders in kunnukara Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41873318
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of 12 Meter High Mast With 6*200 Watt Led Flood Lights Infront Of Kunnukara Juma Masjid, Ward 10, Kunnukara Gramapanchayath Under Mplads Sri Hibi Eden Mp
Open Tender
Indian
Kerala
kunnukara
06-02-2024

Tender Details

Supply, Installation, Testing And Commissioning Of 12 Meter High Mast With 6*200 Watt Led Flood Lights Infront Of Kunnukara Juma Masjid, Ward 10, Kunnukara Gramapanchayath Under Mplads Sri Hibi Eden Mp

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Feb-2024 date extension Date 06-02-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 10500.0 /-
Tender Value
Refer document

BOQ Items

Work Name : SITC OF 12 METER HIGH MAST WITH 6*200 WATT LED FLOOD LIGHTS infront of Kunnukara Juma Masjid, ward 10, Kunnukara Gramapanchayath UNDER MPLADS SRI HIBI EDEN MP
Sl. No. Item Description
1SUPPLY AND INSTALLATION OF 12 MTR HIGH MAST SYSTEM
290.15.2.3 : Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mmmm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
390.15.4.11 : Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea withpower factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4od243069/2023_2024 : Supply and installation of Twin unit aviation LED obstruction light with stand yellow-painted die-cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED lamp
590.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
690.14.3.2 : Supply and providing heavy duty "A" section neoprene gasket in the panel board
7od243070/2023_2024 : Supply and fixing of 1 No of 25 A 3 Pole AC 1 rated power contractor, selector switch for motor control , supply and fixing flush head push button NO-NC and 2.5 sq.mm ISI sq.mm ISI marked FRLS PVC insulated single core copper conductor cable ,1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable.
8od243071/2023_2024 : Supply and fixing of 1 no. of 25 A 2 Pole AC 1 rated power contractor ,25 A connector , 1 nos of Digital timer,suitable copper socket, 2.5 Sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable.
9od243072/2023_2024 : Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32 A 2-Way neutral links mounted on DMC/SMC base and 2.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable.
1090.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
112.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
122.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
132.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
142.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1590.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
16od243073/2023_2024 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
1790.16.4.2 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).
1890.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
1990.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
2090.12.5.3 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
2190.12.9.2 : Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench
229.1.2 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
23od243074/2023_2024 : Supply and fixing of Name Board of MP with Angles ,Flats, Square Pipe, ACP Sheet (complete 4 sides) including Nut and bolt and Supply and fixing of Granite Plaque engraved with the name of MP , name of Project,Name of Plan,<br>Location, Name of LSGD ,Year of Project, Estimate Cost and Name of implementing agency.
24CIVIL WORKS
252.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
262.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
274.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
285.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
295.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
305.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
3113.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
322.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.