| 1 | Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (Below or above ground level) un-reinforced complete all as specified & directed. |
| 2 | M&L for cement concrete 1:3:6 Type C2 using 20 mm graded aggregate as in plinth protection |
| 3 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 4 | M&L for providing cemnet concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 5 | Demolition of brick work in cement mortar incl all quions, arches, pillers etc, but excluding ashlar facing, dressed stone work and precast concrete articles. |
| 6 | M&L brick work with sub class b bricks strait or curved on plan exc 6 M mean radius built in CM 1:4 complete all as specified and directed. |
| 7 | Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. complete all as specified and directed. |
| 8 | M&L 15 mm rendering in CM 1:4 on onother than fair faces of brickwork or concrete surafaces complete all as specified and directed. |
| 9 | M&L for preparation of newly plastered surface and applying two coat ofAcrylic Smooth exterior paint of required shadeapplied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as per manufacturer instruction. |
| 10 | Demolition of RCC of any description and any position not othervise provided for complete all as specified and directed. |
| 11 | M&L TMT bars 10 mm dia and over cut to length bend to shape required, including cranking, bending spirally for hoping for columns hooking ends and binding with MS steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. |
| 12 | M/L mild steelTMT bars 8mm dia cut to length bent to shape required and binding with ms wire anealed not less than 0.9mm dia, complete all as spacified and directed. |
| 13 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 14 | S/F MS steel post struts fencing post including cutting top to shape, drilling holes notching for wire etc including all necessary drilling bolting and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed. |
| 15 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 16 | M &L for preparation of new steel surfaces and applyingtwo coats of black bituminious paintexceeding 10cm in width or girth all as specified and as directed. |
| 17 | M&L for one coat of synthetic enamel paint over a coat of red oxide primer on old steel surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 18 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel n. exc 10cm in width or girth not otherwise described complete all as specified and directed. |
| 19 | Dismantling barbed wire from post. |
| 20 | S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc complete all as specified and directed. Note : Each line wire to be measured. |
| 21 | Fixing only, galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc. complete all as specified and directed. |
| 22 | Dismantling fencing wiremesh any type |
| 23 | Supply only chain link MS galvanised fencing, any size or type |
| 24 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standrad , rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 25 | S&F Concertina coil 600 mm Dia/56 Loops/2.5 mm core wire.Coil Diameter:600 mm. Type of Strip: Heavy Galvanized (IS 1730) Type of Core Wire: Heavy Galvanized (IS 280-2006)Core wire Diameter:2.50mm Dia Zinc coating to Strip: Minimum 200 GSM/Sq mm, Zine Coating on wire: Minimum 275 GSM/Sq mm (IS 6745-1972 reaffirmed 2006).Tensile Strength of wire 1400-1500 N/Sq mm Weight: 14.63 Kg (+5%) Number of Loops: 56Blade Length: 22mmBarb Profile Medium Blade (MBBT)Distance Between Barb35mm.Strechable length 12 mtrs.Type of clip Hardened Steelin Galvanized steel (83 Nos coil per Km) |
| 26 | S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 27 | Providing precast cement concrete type B0 1:2:4 using 12.5 graded sotne aggregate set in CM (1:4) as louvres and jallies, 25mm thick (measured solid), in cluding all mould- ings but excluding frame complete all as specified and directed. |
| 28 | M&L for precast cement concrete type B1 (1:2:4) using 20 mm graded stone aggregate sent in CM (1:6) as in coping complete all as specified and as directed. |