Tender For Repair / Maintenance Of Lt Distribution Network System, Replacement Of Defective Item Of Lt Distribution System At Tech Area Under Age (I) Af Manauri., manauri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Lt Distribution Network System, Replacement Of Defective Item Of Lt Distribution System At Tech Area Under Age (I) Af Manauri.. Submission Date for this Tender is 29-02-2024. Overhead Line Tenders in manauri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41866562
Corrigendum : Tender For Repair / Maintenance Of Lt Distribution Network System, Replacement Of Defective Item Of Lt Distribution System At Tech Area Under Age (I) Af Manauri.
Open Tender
Indian
Uttar Pradesh
manauri
29-02-2024

Tender Details

Tender For Repair / Maintenance Of Lt Distribution Network System, Replacement Of Defective Item Of Lt Distribution System At Tech Area Under Age ( I ) Af Manauri.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-02-2024
2 24-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
INR 9 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINT OF LT DISTRIBUTION NETWORK SYSTEM, REPLACEMENT OF DEFECTIVE ITEM OF LT DISTRIBUTION SYSTEM AT TECH AREA UNDER AGE (I) AF MANAURI
Sl. No. Item Description
1Excavation in trenches not exc 1.5 M wide and not exc 1.5 M indepth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified & directed.
2Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete and as directed.
3Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
4Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 10cm depth complete all as specified & directed. Note:- Punned thickness shall be considered for measurement purpose.
5M&L brick, sub class "B" bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified & directed.
6M&L for cutting /boringto plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as specified & directed. Note: Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site and all as directed by Engineer-in-charge.
7S&F in replacement to GI tubing light grade 80 mm dia of bore with all fitting laid in trenches across the road or fixed with pole/ surface of wall etc as site with required fixing accessories complete all as specified & directed. Make: Tata / Jindal / Swastik / Prakash Surya
8S&F in replacement GI water tubing light grade 50 mm dia of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified & directed. Make: Tata / Jindal / Swastik / Prakash Surya
9Dismantling ofACSR Conductor complete all as specified & directed.
10Dismantling / Taking down any type any size insulator complete all as specified & directed.
11Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified & directed.
12Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 120 Sqmm (earthed) including taking down old unserviceable cable complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
13Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 95 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
14Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area3.5 core x 70 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
15Supply, laid in trench /fixedwith surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area4.0 core x 16 Sqmm (earthed) complete all as specified & directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
16M&L for taking down and re-laying, connecting, jointing, thembling using in suitable size and cramping etc to serviceable XLPE insulate LT cablein all specification incl brick (re-use) and sand (Provided fresh) etc all as per existing complete with other site required works complete all as specified & directed. Note: Sand cushioning punned depth shall be measured and paid separately under respective items.
17Supply, install, testing and commissioning (in replacement) of LT panel size 110 cm x 100 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired duly powder coated with comprising of the following complete all as specified & directed :-
18Notes for Serial Item No. 17.00:- INCOMING: (i) S&F Adjustable thermal and adjustable magnetic setting based MCCB 320 Amp, 415 Volt, 35 kA, 4 pole Rated Ultimate Short circuit Breaking Capacity Ics 75%, at 415 V (kA rms) Vac (kA rms), frame AN type, Confirms to IS/IEC60947-2 (ii) Phase indicating lamp LED type with HRC fuse – 1 Set of three. (iii) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 Nos (iv) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly providedwith suitable size of copper insulated wire with universal coloured code of size 96x96mm - 01 No (v) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm - 01 No (vi) Aluminium bus bar400 Amps capacity of suitable length insulated heavy heatshrinkable sleeves etc - 04 Nos. OUT GOING: (i) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 250 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kA, Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 01 No (ii) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 02 Nos (iii) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 125 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 01 Nos
19Supply, install, testing and commissioning (in replacement) of LT panel size 900 cm x 900 cm x 40 cmenclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door withfront and rear openable with locking arrangement incl inner shutters formounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following complete all as specified & directed:-
20Notes for Serial Item No. 18.00: INCOMING: (i) S&F of on load change over switch capacity 250 Amp, 4 pole, 415 V, Size FR4, Type CO4-400, site convertible fuse version with open execution (Confirm to IEC 60947-3, IS/IEC 60947-3) complete terminal shrouds, source separator and phase gland box, Phase barriers, Handle with door interlock kit, with all fixing accessories suitable for horizontal as well as vertical mounting. (Make: Havells Cat Part No IHCNFO0250 / L&T / Indoasian / ABB / Siemens) (ii) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 250 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Short circuit Breaking Capacity 25 kA,Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 01 Nos (iii) Phase indicating lamp LED type with HRC fuse - 1 Set of three. (iv) ON/OFF indicating lamp on incomer feeder for status of feeder - 02 Nos (v) Digital volt meter AC 0 to 500 volts with inbuilt selector switch duly providedwith suitable size of copper insulated wire with universal coloured code of size 96x96mm - 01 No (vi) Digital Amp meter AC up to 630 Amp with inbuilt selector switch and CT’sduly prewired with suitable size of copper insulated wire withuniversal colour code of size 96x96mm - 01 No (vii) Aluminium bus bar 400 Amps capacity of suitable length insulated heavy heat shrinkable sleeves etc - 04 Nos OUT GOING: (i) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 160 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kA Icu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 02 Nos (ii) S&F Adjustable thermal and adjustable magnetic setting based MCCB 4 Pole 100 Amps, Confirm to IS/IEC:60947-2, Rated Ultimate Shortcircuit Breaking Capacity 25 kAIcu at 415 V, Rated service short circuit Breaking capacity Ics=75% Icu at 415V (KA rms) - 01 Nos
21Taking down old unserviceable Busbar panel and S&F Busbar chamber TPN current capacity 63 Amp 04 way horizontal type, total enclosed with porcelain Insulator and colour coated tinned copper bus bar with suitable size of legs including PCC work fixing on ground with GI angle frame suitable size of clamp, Nut, bolts, suitable size of thimbles for connection etc. complete all as specified & directed. Make: Havells Cat Part No IHBC006304 / L&T / Standard / ABB / Indoasian
22S&F in replacement bracket for street light fittings made out of 40 mm dia "medium grade" galvanized steel (GI) tubing of 1.5 m long, bent to required shape (having an angle 120 degree) including necessary FI clamp (02 Nos of size 40 x 5 mm) suitable size nuts, bolts and washers and fixing to the pole complete all as specified & directed.
23S&F in replacement Energy saving LED street light fitting 60 watt aerodynamically designed for all weather conditions with excellent thermal management with Pressure die cast housing Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >110/125/135 LPW, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including making electric connection using three core copper flexible cable from controll box to street light fitting complete with all accessories all as specified and directed. Note: Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make: Crompton / C&S electric / Havells / Philips / Bajaj
24S&F in replacement LT cable junction box dust and water proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, factory made, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box on steel tubular pole, consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 nos mounted on pole complete all as specified & directed. Make: Sintex CAT part No GS-JB2520 / Henson / Legrand
25M&L for Earthing (in replacement) complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified & directed.
26Notes for Serial Item No. 23.00: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
27S&F in replacement MCCB 4 Pole, 630 Amp, 415 Volt, 50 kA, microprocessor type with adjustable overload,Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 75% Icu at 415 V (kA rms) Confirms to IS/IEC60947-2 with phase barriers, spreader terminals and suitable size of lugs alongwith all connecting accessories complete all as specified & directed. Make:- Schneider / Siemens / ABB / L&T / Havells
28S&F in replacement MCCB 4 Pole, 400 Amp, 415 Volt, 50 kA, microprocessor type with adjustable overload,Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 75% Icu at 415 V (kA rms) Confirms to IS/IEC60947-2 with phase barriers, spreader terminals and suitable size of lugs alongwith all connecting accessories complete all as specified & directed. Make:- Schneider / Siemens / ABB / L&T / Havells
29S&F in replacement MCCB 4 Pole, 250 Amp, 415 Volt, 35 kA, microprocessor type with adjustable overload,Ultimate Shortcircuit Breaking Capacity Icu at 415 V (kA rms) Vac (kA rms), Rated Service short circuit Breaking Capacity Ics = 75% Icu at 415 V (kA rms) Confirms to IS/IEC60947-2 with phase barriers, spreader terminals and suitable size of lugs alongwith all connecting accessories complete all as specified & directed. Make:- Schneider / Siemens / ABB / L&T / Havells
30M&L for marking / stencil writing of pole numbers with black paint complete with in round circal of size of Letter and Number complete all as specified & directed.
31Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail