Maintenance Of Electronic Installation, Fans And Repair Maintenance Of Drinking Water Supply Pump Sets, Sub-Station , Distribution System Dg Sets , Ac Equipments Including Heating System Installed At Igdtuw, Kashmere Gate, Delhi As Per Nit, delhi-Delhi

Public Works Department-PWD has published Maintenance Of Electronic Installation, Fans And Repair Maintenance Of Drinking Water Supply Pump Sets, Sub-Station , Distribution System Dg Sets , Ac Equipments Including Heating System Installed At Igdtuw, Kashmere Gate, Delhi As Per Nit. Submission Date for this Tender is 31-01-2024. Diesel Generators Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

41852938
Maintenance Of Electronic Installation, Fans And Repair Maintenance Of Drinking Water Supply Pump Sets, Sub-Station , Distribution System Dg Sets , Ac Equipments Including Heating System Installed At Igdtuw, Kashmere Gate, Delhi As Per Nit
Open Tender
Indian
Delhi
delhi
31-01-2024

Tender Details

Maintenance Of Electronic Installation, Fans And Repair Maintenance Of Drinking Water Supply Pump Sets, Sub-Station , Distribution System Dg Sets , Ac Equipments Including Heating System Installed At Igdtuw, Kashmere Gate, Delhi As Per Nit

Key Value

Document Fees
Refer document
EMD
INR 154300.0 /-
Tender Value
INR 77.14 Lakhs /-

BOQ Items

Name of Work: MOEI & Fans and RMO Drinking Water Supply Pump Sets, Sub-Station & Distribution System DG Sets & AC Equipments including Heating System installed at IGDTUW, Kashmere Gate, Delhi (SH:- Routine Maintenance of EI & Fans, Compound Light and Routine Maintenance and Operation of Electrical Sub-Station, DG Set & Pump Set, PA system) during 2023-24.
Sl. No. Item Description
1SH-I Routine Operation & Maintenance Running maintenance & operation, general upkeep, preventive maintenance including minor repair works, as and when required and recording reading in log book for 11 KV/440 Volts electrical substation comprising of transformer, HT/LT Panel, ACB, MCCB & allied accessories & keeping the entire installation on functional mode including D.G. set comprising of A.M.F. Panel & allied accessories for maintaining essential power supply, as and when required, on account of failure of main electrical power supply/load shedding including minor repair works by deploying staffs (wireman//E&M Operator- 3 Nos. round the clock, Khallasi - 1 No. general shift on all working day including Sunday and holiday) as per details and terms & conditions attached etc. as required.
2Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the departmentto the contractor & keeping the entire installation on functional mode including running maintenance & operation and general upkeep of various capacity drinking water supply pump sets in different location along with sluice / gate valves etc. to fill up over head water tank for timely delivery of water supply and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation & keeping the entire installation on functional mode by deploying staffs as per details and terms & conditions attached etc. as required. (wireman//E&M Operator- 3 Nos. round the clock, Khallasi - 3 Nos. round the clock on all working day including Sunday and holiday)
3Providing services of Supervisor having experienced in electrical & mechanical works as per details deploying staff Supervisor- 1No. In general shift on all days of the month including Sunday & Holiday and as per Engineer-in-charge and terms & conditions attacted etc. complete as required.
4SH-III - Repair/Replacement/Servicing of Electrical Installations Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group C
5Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.(a) Group C
6Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
8(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
9(d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
10Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
11Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. Mm
13(b) 3 x 4 sq. Mm
14(c) 3 x 6 sq. Mm
15Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 12 Module (200 mmX150 mm)
16(b) 8 Module (125 mmX125 mm)
17(c) 6 Module (200 mmX75 mm)
18Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch
19(b) 3 pin 5/6 A socket outlet
20(c) 15/16 A switch
21(d) 6 pin 15/16 A socket outlet
22Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (a) 5/6 A switch
23(b) 3 pin 5/6 A socket outlet
24(c) 15/16 A switch
25(d) 6 pin 15/16 A socket outlet
26Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door
27(b) 12 way , Double door
28Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 8 way (4 + 24), Double door
29(b) 12 way (4 + 36), Double door
30Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 5 A to 32 A SP
31(b) 63 A SPN
32(c) 63 A TPN
33Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
34Supplying, installation, testing & commissioning of energy efficient 1200 mm sweep size, ceiling fan, including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required.
35Supply and fixing of 400 mm sweep size wall mounted fan complete with inbuilt electronic regulator, blade, wire lead with moulded plug top etc. as required.
36Supplying and installation of heavy duty exhaust fan of following size, 900 rpm speed with shutter & louvers in the existing opening alongwith connection, testing & commissioning etc. as required. (a) 300 mm sweep size
37Supplying and fixing, fresh air fan of 250 mm sweep size suitable for 220 volts, 50 hz, A.C. supply, in the existing opening including, making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc as required.
38Supplying, installation, testing & commissioning of 20 - 22 watt of 1200 mm long, 6500K energy efficient LED wall mounted light luminaries, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work 230 volt AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. The luminaries shall be submitted with LM-80 report with a life of 50000 hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
39Supplying, installation, testing & commissioning of 15 watt recess/surface mounted glarefree round LED downlight, system lumen efficacy 90Lm/W, cool day light (5700K to 6500K), power factor>0.90, CRI>80, LED lamp complete with all accessories, testing & commissioning etc. as required.
40Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size)suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with thehelp of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 34W to 36W, LED lumen should be = 3600 system efficacy of = 110 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
41Supplying, installation, testing & commissioning of energy efficient LED flood light luminaries of system wattages 200 watt complete with mounting brackets and accessories on the street light pole with help of tower wagon including connections complete as required. The LED luminaries should confirm the following technical specifications:-a) Type of LED: High power LEDs Nichia / Osram / Cree / Philipsb) driver efficiency >85%c) System Efficacy >120 lm/wd) color Index(CRI) Ra>70e) Color Temperature (CCT) Cool white: 4000°Kf) Input Voltage. 140-270V ACg) Frequency Range 50-60Hzh) Power Factor(PF) > 0.95i) Surge protection = 10KVj) Total Harmonic Distortion(THD)< 10%k) Working Environment 0°C to 50°C;10%-90%RH l) Working lifetime: >50000 hrs.m) IP Rating :- IP66n) Housing and finish:-epoxy powder coated die cast aluminum housing with elegantly designed heat sink for efficient thermal management and to excellent corrosion resistant, cable gland P49 is provided at cable entry cover & high quality toughned glass.
42Fabrication, Supplying and installation of outdoor type, sloping roof cubical feeder pillar of surface area/size not less than 1 sq meter with minimum depth of 50 cm made out of CRCA M.S. Sheet 2 mm Thickness (14 SWG) duly compartmentalized having 4 strip bus bar of 200 Ampers capacity double door with double locking arrangement (one sliding lock in front and one godown lock each at front and rear for protection) dust proof vermin process, duly fixed on M.S. angle iron frame work of size 50 mm X 50 mm X 6 mm (NS) 90 cm long legs, out of which 45 cm duly grouted in cement concrete foundation of size 30 cm X 30 cm X 50 cm deep 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) duly painted with one coat of red oxide & two coats of superior quality enamel paint in approved shade and colour complete etc. as required including supplying & fixing of following accessories in the feeder pillar complete with testing, earth studs, earth strips etc. as required.
43Supplying & fixing the following accessories in the above feeder pillar board etc. as required. (a) 250 A, 35 kA,TPMCCB
44(b) 150 A, 16 kA,TPMCCB
45(c) Digital type Volt Meter (0-500 Volts) with selector switch
46(d) Digital type Ammeter (0-250 ampers) with selector switch
47(e) Indicating Light LED type with 2 Ampers SP MCB (3 Nos.)
48(h) 400/5 Amp. CT (3 Nos.)
49(i) Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
50Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 100 A, 16 kA,TPMCCB
51(b) 250 A, 35 kA,TPMCCB
52(c) 400 A, 35 kA,TPMCCB
53Supplying and fixing of following size PVC round sheathed multicore flexible copper cable on surface connecting indoor unit to outdoor unit i/c connection, testing & commissioning etc. as reqd. (a) 3 x 2.5 sq.mm
54(b) 3 x 1.5 sq.mm
55Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade in following manner etc. as reqd. (a) 4 x 25 sq.mm on wall surface
56(b) 3.5 x 50 sq.mm on wall surface
57(c) 3.5 x 10 sq.mm on wall surface
58Earthing with G.I. earth pipe 4.5 meters long, 40 mm diameter including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
59Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
60Providing and fixing of 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
61Annual Preventive & Comprehensive/Periodical Maintenance Of following Cummins make D.G. Sets installed at following locations alongwith engine, alternator, AMF panel, batteries, pipeline and other associated accessories etc. complete with routine testing etc. as reqird and attending all major/minor faults or failure or complaint complete in all respect & providing at least one Electrical & Mechanical visit in a month as required, as per terms & condition attached and as per direction of Engineer-In-Charge a) 250 KVA capacity DG Set (ESN 25280794)- AUD
62b) 250 KVA Capacity DG (ESN 25758144/25758145 - 2 Nos)
63c) 125 KVA capacity DG Set
64B-Check maintenance of following capacity Cummins make DG Sets including replacement of element assembly, element lub oil filter, check kit 6 CTA, Kit fuel filter and ring, kit super bypass, filter element, inhibitor, corrosion, air cleaner element, seal O-ring, Gasket, rocker, valve cover, strip test, lubricant oil etc. complete as required. a) 250 KVA capacity DG Set (ESN 25280794) - AUD
65b) 250 KVA Capacity DG (ESN 25758144/25758145 - 2 Nos)
66c) 125 KVA capacity DG Set
67Less credit of following electrical accessories etc. complete as required. (a) Assorted copper wire/cable/pipe
68(b) Scrap iron/ conduit/ box
69(c) DBs (assorted size)
70(d) MCBs (assorted size)
71(e) MCCBs (assorted size)
72(f) Switch/Socket (assorted size)
73(g) Ceiling Fans assorted size
74(h) Wall Fan (assorted size)
75(i) Exhaust Fan (assorted size)
76(j) Fresh Air Fan (assorted size)
77(k) Batten Lights (assorted size)
78(l) Downlights (assorted size)
79(m) Panel Lights (assorted size)
80(n) Flood Lights (assorted size)
81(o) Cubical Panel with accessories (assorted size)
82(p) Assorted XLPE aluminum cable