| 1 | SCHEDULE ‘A’ PART - I (Water Supply Scheme Moreh ) |
| 2 | Supply installation testing & commissioning of 20 HP open well Submersible pump Modal No-MRV (T)400 4/20 head 52-108 Mtr,RPM 28003 phasedelivery size 80 mm(KSB) ,including suitable starterdelta starter. |
| 3 | Supply installation testing & commissioning of 10 HP open well Submersible pump , head 100 Mtr ,delivery size 80 mm,3 phase,RPM 2800,(KSB) including suitable starterdelta starter |
| 4 | Providing and fixing 80 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 5 | Supply installation testing & commissioning of 7.5 HP open well Submersible pump Modal No-MRV (T)150-5/7.5 head 46-93 Mtr,RPM 28003 phasedelivery size 50 mm (KSB),including suitable starterdelta starter |
| 6 | Providing and fixing 80 mm dia Gun metal valve Non Return Valveof approved quality Vertical |
| 7 | Providing and fixing 65 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 8 | Providing and fixing 65 mm nominal G.I. Union in G.I. pipe including cutting and threading the pipe and making long screwsbore |
| 9 | Providing and fixing 65 mm dia gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 10 | Supply and installation of iron remover plant complete with pressure filter, catayatic media, air compressore, back washing facility including RCC foundation of capacity 5000 ltrs/hr. |
| 11 | Supply , Laying and testing cable armouredXLPE insulated, screened ,PVC beded, galvnised steel strip, heavy duty 1100 V with aluminium conductor, size 70 sqmm 3.5 core . |
| 12 | SCHEDULE ‘A’ PART - I(A) (UG Sump Moreh ) |
| 13 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 14 | Supplying and stacking 90 mm to 45 mm size stone aggregate at site.Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 15 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA) upto 20%. |
| 16 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 18 | SCHEDULE ‘A’ PART - II (Water Supply OLD KLP) |
| 19 | Supply installation testing & commissioning of 15 HP open well Submersible pump 11 KW 80 Mtr head 3 phase including suitable stardelta starter |
| 20 | Supply & fixing of 6 Sqmmcopper cable 4 Sqmm 3 core |
| 21 | Providing and fixing 65mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 22 | Providing and fixing 50mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 23 | Providing and fixing 40mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 24 | Providing and fixing 50mm dia Gun metal valve Non Return Valveof approved quality Vertical |
| 25 | Providing and fixing 40mm dia Gun metal valve Non Return Valveof approved quality Vertical |
| 26 | Providing and fixing 50 mm nominal G.I. Union in G.I. pipe including cutting and threading the pipe and making long screwsbore |
| 27 | Providing and fixing 40 mm nominal G.I. Union in G.I. pipe including cutting and threading the pipe and making long screwsbore |
| 28 | Providing and fixing 65 mm dia gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 29 | Providing and fixing 40mm mm dia gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 30 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 31 | Providing and fixing CP stop cock of approved quality :15 mm nominal bore |
| 32 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter with 150mm extention |
| 33 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesconfirming to IS 15801, UV stabilized & anti - microbial fusion welded, havingthermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin-Charge. Internal Exposed on wall 15 mm dia |
| 34 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 35 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 36 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesconfirming to IS 15801, UV stabilized & anti - microbial fusion welded, havingthermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin-Charge. Internal Exposed on wall 25mm dia |
| 37 | Providing and fixing PPR gate valve with C.I. wheel of approved quality(screwed end) :25 mm nominal bore |
| 38 | Supply and fixing of 2 HP monoblock pump single phase 45 mtr head 220 Volts with suction pipe, Footvalve and provision of priming ofpump |
| 39 | Supply and fixing of 500 Ltr Per Hour water purification plant / RO plant alongwith dosing pump, membrane pump, stand, membrane, UV+RO, 1X extra sediment filter out side the plant, pressure gauge necessary electrical accessories |
| 40 | SCHEDULE ‘A’ PART - II (A)(2xRCC TANK ) |
| 41 | Earth work in surface excavation not exceeding 30 CM in depth but exceeding 1.5M in width as well as 10 Sqm on plan including getting out and disposal of excavated earth up to 50 M and lift up to 1.5m as directed by Engr-in-charge |
| 42 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual menas in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of disposal of surplus excavated soild as directed, within a lead of 50 m. All kind of soil. |
| 43 | 1:3:6 (1 Cement : 3 Coarse snd (Zone -III) :6 Graded stone aggregate 20mm nominal size) |
| 44 | Centering and shuttering including propping etc and removal of form work for retaining wall return walls, walls (any thickness) including attached pillasters, butteresses, plinth and string fillets kerbs and steps etc |
| 45 | Centering and shuttering including propping etc and removal of form work for retaining wall return walls, walls (any thickness) including attached pillasters, butteresses, plinth and string fillets kerbs and steps etc |
| 46 | Steel reinforcement for RCC work including straightening, cutting bending placing in position and binding all complete up to plinth level Thermo-Mechanically treated bars of grade FE-500D or more |
| 47 | Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level up to floor vie level excluding 1:1.5:3 (1 cement : 1.5 Coarse sand (zoneIII) :3 grade stone nominal size) |
| 48 | Reinforced cement concrete work in beams, suspended floors, roofs have slope up to 15digree landings, balconies, shelves, Chhajas, balconies, shelves, Chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above pinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcemetn with 1:1.5:3 (1 cement : 1.5 Coarse sand (zoneIII) :3 grade stone nominal size) |
| 49 | 15mm Cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 fine sand) |
| 50 | Extra for providing and mixing water proofing material in cement plaster work in proportin recommended by the manufacturers |
| 51 | SCHEDULE ‘A’ PART - II(B) (2X Borewell) |
| 52 | Transportation of rig and other tools, equipments and machinery (compressor etc) as site as required for drilling of tube well, and dismantling after completion as directed by enginner -in-charge |
| 53 | Trial bore will 150mm (6\") dia bore in all classes of soil including hard work soil samples at ever 3.0 meters or wherever there is a change in strata up to the required dpth till suitable water bearing strata, complete as directed by Engr-in-charge |
| 54 | Re-boring the above 150mm dia bore to bigger sizes of 200mmdia in all classes of soils including hard rock complete as directed by the engineer-in-charge |
| 55 | Washing the bore properly including extraction of drilling rod, washing keeping priperly at site in all complete including development with air compressor incluidng cost of fuel mobil and other accessoreis as directed |
| 56 | Supply and lowering of MS PIPES /Stainer of 200 mm dia including centering and welding |
| 57 | Development of well with air compressor including cost of fuel, mobile and other accessories |
| 58 | Supply and fixing MS well cover with PCC plateform all around of size 1.5x1.5x.30m |
| 59 | Supply, fixing testing, lowering of submersible pumps 7.5 HP, 3 Phase, 440 V, 50 Hz, 120 Mtr Head Vertical with suitable starter |
| 60 | Supply and lowering of3 core flat submersible copper cable 4 Sqmm dia |
| 61 | Supply and lowering of 65 mm dia UPVC columnpipes one side internal threade another side external thread for having thermal stability for hot & cold water supply including all UPVC plain & brass threaded fittings this includes jointing of pipes & fittings withcomplete as per direction of Engr -in-charge |
| 62 | Supply and fixing of hanging rop PVC insulated heavey GI wire 20 Sqmm |
| 63 | Gravel packing in tubewell constructionin accordance with IS: 4097, including providing gravel fine/medium/coarsde, in required grading & sizes as per actual requirement, all complete as per direction of engr-in-charge. |
| 64 | SCHEDULE ‘A’ PART - III (Water Supply Scheme PT 422 ) |
| 65 | Supply installation testing & commissioning of 15 HP open well Submersible pump 11 KW 80 Mtr head 3 phase including suitable stardelta starter |
| 66 | Supply & fixing of 6 Sqmmcopper cable 4 Sqmm 3 core |
| 67 | Providing and fixing 65mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 68 | Providing and fixing 50mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 69 | Providing and fixing 40mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 70 | Providing and fixing 50mm dia Gun metal valve Non Return Valveof approved quality Vertical |
| 71 | Providing and fixing 40mm dia Gun metal valve Non Return Valveof approved quality Vertical |
| 72 | Providing and fixing 50 mm nominal G.I. Union in G.I. pipe including cutting and threading the pipe and making long screwsbore |
| 73 | Providing and fixing 40 mm nominal G.I. Union in G.I. pipe including cutting and threading the pipe and making long screwsbore |
| 74 | Providing and fixing 65 mm dia gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 75 | Providing and fixing 40mm mm dia gun metal gate valve with C.I. wheel of approvedquality (screwed end) : |
| 76 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 77 | Providing and fixing CP brass stop cock of approved quality :15 mm nominal bore |
| 78 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter with 150mm extention |
| 79 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesconfirming to IS 15801, UV stabilized & anti - microbial fusion welded, havingthermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin-Charge. Internal Exposed on wall 15 mm dia |
| 80 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 81 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 82 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesconfirming to IS 15801, UV stabilized & anti - microbial fusion welded, havingthermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin-Charge. Internal Exposed on wall 25mm dia |
| 83 | Providing and fixing PPR gate valve with C.I. wheel of approved quality(screwed end) :25 mm nominal bore |
| 84 | Supply and fixing of 2 HP monoblock pump single phase 45 mtr head 220 Volts with suction pipe, Footvalve and provision of priming ofpump with suitable starter |
| 85 | Supply and fixing of 500 Ltr Per Hour water purification plant / RO plant with steel structure alongwith dosing pump, membrane pump, stand, membrane, UV+RO, 1X extra sediment filter out side the plant, pressure gauge necessary electrical accessories |
| 86 | SCHEDULE ‘A’ PART - III(A)(2xRCC TANK ) |
| 87 | Earth work in surface excavation not exceeding 30 CM in depth but exceeding 1.5M in width as well as 10 Sqm on plan including getting out and disposal of excavated earth up to 50 M and lift up to 1.5m as directed by Engr-in-charge |
| 88 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual menas in foundation treanches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of disposal of surplus excavated soild as directed, within a lead of 50 m. All kind of soil. |
| 89 | 1:3:6 (1 Cement : 3 Coarse snd (Zone -III) :6 Graded stone aggregate 20mm nominal size) |
| 90 | Centering and shuttering including propping etc and removal of form work for retaining wall return walls, walls (any thickness) including attached pillasters, butteresses, plinth and string fillets kerbs and steps etc |
| 91 | Centering and shuttering including propping etc and removal of form work for retaining wall return walls, walls (any thickness) including attached pillasters, butteresses, plinth and string fillets kerbs and steps etc |
| 92 | Steel reinforcement for RCC work including straightening, cutting bending placing in position and binding all complete up to plinth level Thermo-Mechanically treated bars of grade FE-500D or more |
| 93 | Reinforced cement concrete work in wall (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc above plinth level up to floor vie level excluding 1:1.5:3 (1 cement : 1.5 Coarse sand (zoneIII) :3 grade stone nominal size) |
| 94 | Reinforced cement concrete work in beams, suspended floors, roofs have slope up to 15digree landings, balconies, shelves, Chhajas, balconies, shelves, Chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above pinth level up to floor five level, excluding the cost of centering, shuttering finishing and reinforcemetn with 1:1.5:3 (1 cement : 1.5 Coarse sand (zoneIII) :3 grade stone nominal size) |
| 95 | 15mm Cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement :3 fine sand) |
| 96 | Extra for providing and mixing water proofing material in cement plaster work in proportin recommended by the manufacturers |
| 97 | SCHEDULE ‘A’ PART - III(B) (Borewell) |
| 98 | Transportation of rig and other tools, equipments and machinery (compressor etc) as site as required for drilling of tube well, and dismantling after completion as directed by enginner -in-charge |
| 99 | Trial bore will 150mm (6\") dia bore in all classes of soil including hard work soil samples at ever 3.0 meters or wherever there is a change in strata up to the required dpth till suitable water bearing strata, complete as directed by Engr-in-charge |
| 100 | Re-boring the above 150mm dia bore to bigger sizes of 200mmdia in all classes of soils including hard rock complete as directed by the engineer-in-charge |
| 101 | Washing the bore properly including extraction of drilling rod, washing keeping priperly at site in all complete including development with air compressor incluidng cost of fuel mobil and other accessoreis as directed |
| 102 | Supply and lowering of MS PIPES /Stainer of 200 mm dia including centering and welding |
| 103 | Development of well with air compressor including cost of fuel, mobile and other accessories |
| 104 | Supply and fixing MS well cover with PCC plateform all around of size 1.5x1.5x.30m |
| 105 | Supply, fixing testing, lowering of submersible pumps 7.5 HP, 3 Phase, 440 V, 50 Hz, 120 Mtr Head Vertical with suitable starter |
| 106 | Supply and lowering of3 core flat submersible copper cable 4 Sqmm dia |
| 107 | Supply and lowering of 65 mm dia UPVC columnpipes one side internal threade another side external thread for having thermal stability for hot & cold water supply including all UPVC plain & brass threaded fittings this includes jointing of pipes & fittings withcomplete as per direction of Engr -in-charge |
| 108 | Supply and fixing of hanging rop PVC insulated heavey GI wire 20 Sqmm |
| 109 | Gravel packing in tubewell constructionin accordance with IS: 4097, including providing gravel fine/medium/coarsde, in required grading & sizes as per actual requirement, all complete as per direction of engr-in-charge. |