Tender For Maintenance And Repairs To Street Lights, Security Light / Solar Lights Of Any Type, Garden Lights, Post Top Lantern And Connected Items At Afac Under Age (I) (Af) Coimbatore, coimbatore-Tamil Nadu

Military Engineer Services-MES has published Tender For Maintenance And Repairs To Street Lights, Security Light / Solar Lights Of Any Type, Garden Lights, Post Top Lantern And Connected Items At Afac Under Age (I) (Af) Coimbatore. Submission Date for this Tender is 21-02-2024. Electrification Work Tenders in coimbatore Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41842518
Corrigendum : Tender For Maintenance And Repairs To Street Lights, Security Light / Solar Lights Of Any Type, Garden Lights, Post Top Lantern And Connected Items At Afac Under Age (I) (Af) Coimbatore
Open Tender
Indian
Tamil Nadu
coimbatore
21-02-2024

Tender Details

Tender For Maintenance And Repairs To Street Lights, Security Light / Solar Lights Of Any Type, Garden Lights, Post Top Lantern And Connected Items At Afac Under Age ( I ) ( Af ) Coimbatore ; 1 M&L For Taking Down The Unserviceable Street Light / Flood Light / Post Top Lanter / Garden Light Fitting Of Any Type & Capacity From Its Original Location By Unscrewing The Nuts, Bolts, Washers Etc Andand Carrying To Work Shop For Repair / Replacement And Re-Fixing The Same Position Completeall As Specified And Directed By The Engr-In-Charge. Note: - ( 1 ) All T&P Requiredshall Be Provided By The Contractor.Minor Spare Parts Such As Connector , Nut, Bolts, Washers, Etc Required For Repair / Replacement Shall Deemed To Be Included In Quoted Rates 2 Taking Out Care Fully Old Existing Lt Cable Of Any Size From The Trenches By Removing Bricks And Keeping Cable & Bricks Aside For Re-Use Or For Taking Credit Completeall As Specified And Directed 3 Supply Only Led Driver Suitable For Street Light For Capacity 25- 40 W Completeall As Specified And Directed 4 Supply Only Led Driver Suitable For Street Light For Capacity 45-90 Wcompleteall As Specified And Directed 5 Supply Only Energy Saving And Environmental Friendly Long Life 45W Ledstreet Light Made Up Of Pressure Die Cast Aluminium Housing With High Efficiency Led As Lighting Source And Lens Embedded Pc Cover Having Bottom Opening Separate Drive Compartment With Ip66and Impact Resistance Of Ik08 Completeall As Specified And Directedmake : Havells Endurasundownsl45wled 765 Pas Ybopc / Bajaj / Crompton Or Equivalent 6 Supply Only Led Driver Suitable Led Floodlight For Capacity 100-150 Completeall As Specified And Directed 7 Supply Only Energy Saving And Environmental Friendly Long Life Ecxclusive Innnovative Die-Cast Aluminium Ip66 Flood Light150w Led Make : Havells Jetairsfls150wled757p2av2wbltg / Bajaj / Crompton Or Equivalent 8 Supplyonly Post Top Lantern Led Type 20 Watt 230 Watt Volts Ac Outdoor Type With Decorative Post Top For 360 Degree Indirect Light Ip 65 Protection With Impact And Corrosion Resistant Complete With Driver And Lamp Complete. 9 Material Only In Repair For Unserviceable Post Top Lantern Led Type Of Any Watt And Size 230 Watt Volts Ac Outdoor Type With Decorative Post Top By Replacing Wornout Driver, Led Lamp, Flexible Cable And Make The Light In Operational Condition Complete All As Specified And Directed. 10 M / L For Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, Multi Stranded, 1100 Volts Grade, Cross-Sectional Area 25 Sqmm 3.5 Core Completeall As Specified And Directed 11 M / L For Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, Multi Stranded, 1100 Volts Grade, Cross-Sectional Area 35 Sqmm 3.5 Core Completeall As Specified And Directed 12 Excavation In Trenchesnot Exceeding 1.5 M Wide And N.Exc. 1.5 M Deep And Getting Out In Hard / Dens Soil For Laying Of Ug Cables Completeall As Specified And Directed 13 Returning, Filling In, Including Removing Vegetation Roots, Sieving, Spreading, Leveling, Upto 18 Cm Thickness For Cable Cushioning With The Soil Excavated Under Item No.1 Above.Completeall As Specified And Directed 14 Removing Excavated Materials ( Soils ) To A Distance Not Exc 50M And Depositing Where Directed At A Level Not Exc. 1.5 M Above The Starting Point Completeall As Specified And Directed 15 Supply And Laid Well Burnt Bricks Sub-Class B Designation 75 For Cable Protection, Brick Shall Be Laid Dry Flat As Width Of Brick Eqals To The Length Of Cable And The Gap Between Adjacent Brick Shall Not Exceeded 10 Mm, Complete All As Specified And As Directed. 16 M&L For Riddled Earth Filling In Trenches Above And Below The Cable As In Cable Protection.Completeall As Specified And Directed.Note:- Punned Thickness Shall Be Mesured And Paid. 17 M&L For Horizontal Boring Under Road / Path / Hard Standing Suitable Forinserting Gi Pipe 80 Mm Dia Under The Road / Path / Hard Satnding Complete And The Depth Of Horizontal Bore Shall Not Be Less Than 50 Cm Below The Normal Ground Level By Trench Less Technology Usin Necessary Machinecompleteall As Specified And Directed 18 M&L For Gi Pipe 80 Mm Dia Light Grade With All Fittings For Cable Protection Laid Under Road / Path / Hard Standing Or Fixed With Wall / Pole Etc Completeall As Specified And Directed 19 S&F Cable Junction Box Ip66 Halogen Free And Weather Proof For Out Door Installation Made Of Thermoplastic Material Of Size 167Mm X125mm X 82 Mm, Suitable For Upto 16 Sqmm Cable Entry & Cable Out Opening , Fitted With 01 Nos Mcb , Spn 32 Amps For Incomer And 01 Nos Mcb Sp, 06 Amps As Out Going Complete Internally Pre-Wired Fitted With Terminals, Connectors Etc And Including Neccessary Fixing Arrangement Such As Nuts, Bolts, Washers, Ms Clamps Made Of 20X5 Mm And Painting Etc & Making Connection Complete. Make: Hensel, Cat No. Kf1616b Or Equivelent In Sintex, Array 20 M&L For Gi Bracketof Size32-50 Mm Dia And 1.20 Mtr Long Gi Pipe Light Grade Bent To Shape Ncluding Neccessary Fixing Arrangement Such As Nuts, Bolts, Washers, Ms Clamps Made Of 20X5 Mm And Painting Etc & Making Connection Complete 21 Laying Only Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade 22 M&L Formachine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And Pigment 23 S&F In Replacement Of Digitaltimer Switch With Astonomical Function For Switching On / Off Lights2 Out Output16a And Other Electrical Deices According To The Rising / Setting Of The Sunfor Street Light And Making Connetion Complete As In Position And As Directed By Engr-In-Charge Make : Legrand ( Dx3 Time Switches ) / Havells / Bajaj 24 M&L For Painting Of Street Light Pole Of 9 Mtr Long Including Preparation Of Old Paint Surface, Painting Two Coats Of Aluminium Paint Over A Coat Of Red-Oxide Thenwriting Pole Number Over Black Strip Complete All As Specified And Direted Please. Note :- Painting To Be Carried After Removing Brackets And Two Holes To Be Made For Insertion Of Hanging Wire 25 S&F In Replacement Of Pvc Insulated And Fr Pvc Round Copper Conductor ( Flexible ) 1100V 1.0 Sqm 3 Coreand Making Connetion Complete As In Position And As Directed By Engr-In-Charge 26 S&F In Replacement Ofsolar Street Light With Motion Sensor With Inbuilt Battery Of 7 W Lumen Out Put 1000 Completeall As Specified And Directedmake : Philips Brc010led10 / 765 27 M&L For Gi Pipe Of 32-50 Mm Dia Gi Pipe Light Grade Bent To Shape Ncluding Neccessary Fixing Arrangement Such As Nuts, Bolts, Washers, And Painting Etc From Junction Box To Copping Connection Completeall As Specified And Directed 28 M&L For Cross Arms, Bracking Supports Clamps And Bacl Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers Welding, Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Primer Coat, One Under Coat And One Finishing Coat Of Paint Completeall As Specified And Directed 29 M&L For Led Bollard Light In Ip 65 With Robust Design And Efficient Light Distribution 10 W Complete With Necessary Pcc Work Completeall As Specified And Directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Feb-2024 Tech_Corrigendum Technical Bid 14-02-2024
2 14-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 18000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:MAINT AND REPAIRS TO STREET LIGHTS, SECURITY LIGHT / SOLAR LIGHTS OF ANY TYPE, GARDEN LIGHTS, POST TOP LANTERN AND CONNECTED ITEMS AT AFAC UNDER AGE (I) (AF) COIMBATORE
Sl. No. Item Description
1M&L for taking down the unserviceable street light/flood light/Post top lanter/Garden light fitting of any type & capacity from its original location by unscrewing the nuts, bolts, washers etc andand carrying to work shop for repair/replacement and re-fixing the same position completeall as specified and directed by the Engr-in-charge. Note: -(1) All T&P requiredshall be provided by the contractor.Minor spare parts such as connector , nut, bolts, washers,etc required for repair/replacement shall deemed to be included in quoted rates
2Taking out care fully old existing LT cable of any size from the trenches by removing bricks and keeping cable & bricks aside for re-use or for taking credit completeall as specified and directed
3Supply only LED Driver suitable for Street light for capacity 25- 40 W completeall as specified and directed
4Supply only LED Driver suitable for Street light for capacity 45-90 Wcompleteall as specified and directed
5Supply only Energy saving and environmental friendly long life 45W LEDstreet light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening separate drive compartment with IP66and impact resistance of IK08 completeall as specified and directed Make : Havells ENDURASUNDOWNSL45WLED 765 PAS YBOPC / Bajaj/Crompton or Equivalent
6Supply only LED Driver suitable LED Floodlight for capacity 100-150 completeall as specified and directed
7Supply only Energy saving and environmental friendly long life ecxclusive innnovative die-cast aluminium IP66 flood light150W LED Make : Havells JETAIRSFLS150WLED757P2AV2WBLTG /Bajaj/Crompton or Equivalent
8Supplyonly post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
9Material only in repair for unserviceable post top lantern LED type of any watt and size 230 watt volts AC outdoor type with decorative post top by replacing wornout driver, LED lamp, flexible cable and make the light in operational condition complete all as specified and directed.
10M/L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core completeall as specified and directed
11M/L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, multi stranded, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core completeall as specified and directed
12Excavation in trenchesnot exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out in Hard/dens soil for laying of UG cables completeall as specified and directed
13Returning, filling in, including removing vegetation roots, sieving, spreading, leveling,upto 18 cm thickness for cable cushioning with the soil excavated under item No.1 above.completeall as specified and directed
14Removing excavated materials (soils) to a distance not exc 50m and depositing where directed at a level not exc. 1.5 m above the starting point completeall as specified and directed
15Supply and laid well burnt bricks sub-class "B" designation 75 for cable protection, brick shall be laid dry flat as width of brick eqals to the length of cable and the gap between adjacent brick shall not exceeded 10 mm, complete all as specified and as directed.
16M&L for riddled earth filling in trenches above and below the cable as in cable protection.completeall as specified and directed. Note:- Punned thickness shall be mesured and paid.
17M&L for horizontal boring under road/path/hard standing suitable forinserting GI pipe 80 mm dia under the road/path/hard satnding complete and the depth of horizontal bore shall not be less than 50 CM below the normal ground level by trench less technology usin necessary machinecompleteall as specified and directed
18M&L for GI pipe 80 mm dia light grade with all fittings for cable protection laid under road/path/hard standing or fixed with wall/pole etc completeall as specified and directed
19S&F Cable junction box IP66 halogen free and weather proof for out door installation made of thermoplastic material of size 167mm x125mm x 82 mm, suitable for upto 16 sqmm cable entry & cable out opening , fitted with 01 Nos MCB , SPN 32 Amps for incomer and 01 Nos MCB SP,06 Amps as out going complete internally pre-wired fitted with terminals,connectors etc and including neccessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and painting etc & making connection complete. Make: Hensel, Cat No. KF1616B or equivelent in Sintex, Array
20M&L for GI bracketof size32-50 mm dia and 1.20 Mtr long GI pipe light grade bent to shape ncluding neccessary fixing arrangement such as nuts, bolts, washers, MS clamps made of 20x5 mm and painting etc & making connection complete
21Laying only Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness,M-35 Grade
22M&L forMachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness,M-35 Grade With Grey cement and pigment
23S&F in replacement of Digitaltimer switch with astonomical function for switching on/off lights2 out output16A and other electrical deices according to the rising/setting of the sunfor street light and making connetion complete as in position and as directed by Engr-in-Charge Make : Legrand (DX3 time switches) /Havells/Bajaj
24M&L for painting of street light pole of 9 mtr long including preparation of old paint surface, painting two coats of aluminium paint over a coat of red-oxide thenwriting pole number over black strip complete all as specified and direted please. Note :- Painting to be carried after removing brackets and two holes to be made for insertion of hanging wire
25S&F in replacement of PVC insulated and FR PVC round copper conductor (flexible) 1100V 1.0 Sqm 3 coreand making connetion complete as in position and as directed by Engr-in-Charge
26S&F in replacement ofsolar street light with motion sensor with inbuilt battery of 7 W lumen out put 1000 completeall as specified and directed Make : Philips BRC010LED10/765
27M&L for GI pipe of 32-50 mm dia GI pipe light grade bent to shape ncluding neccessary fixing arrangement such as nuts, bolts, washers, and painting etc from Junction box to copping connection completeall as specified and directed
28M&L for cross arms, bracking supports clamps and bacl plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint completeall as specified and directed
29M&L for LED Bollard light in IP 65 with robust design and efficient light distribution 10 W complete with necessary PCC work completeall as specified and directed