| 1 | Earthwork in excavation:Labour only for earthwork in excavation in foundation, in foundation trenches etc., not exceeding 1.50 m wide and not exceeding 1.5 m in depth getting out in hard or dense soil as ordered by EIC/SIC. |
| 2 | Returning, filling: Labour only for returning, filling in, of soft disintegrated soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. as ordered by EIC/SIC. |
| 3 | Removal of spoil: Labour only for removal of spoil mixed with excavated earth, broken bricks, concrete rubbish and debris, broken glasses from work site to a distance of 1.50 km. outside the factory or as directed by the EIC/SIC (20% deduction in measurement will be made from the volume of spoil ). |
| 4 | P.C.C. (1:2:4) : M & L for providing plain cement concrete type-B1, 1:2:4 mix ( using 12.5 mm graded stone aggregate ) as in sub-base, filling and mass concrete, topping of floor as ordered by EIC/SIC. |
| 5 | R.C.C (1:1.5:3).: M & L for providing reinforced cement concrete type M-20, 1:1.5:3 mix (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, etc.as ordered by EIC/SIC. |
| 6 | R.C.C (1:1.5:3): M & L for providing reinforced cement concrete type M-20, 1:1.5:3 mix (using 20 mm graded stone aggregate) Chullah hoods; stairways including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, Spiral stair cases (including landings); etc.as ordered by EIC/SIC. |
| 7 | Brick work(1:6): M & L for brick work with old size subclass\"b\" bricks, straight or curved on plan exc 6m mean radius with (1: 6) cement morter as ordered by EIC/SIC. |
| 8 | Cutting holes: Labour only for cutting holes into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete Exc 150 sq. cm but n exc 400 sq. cm ,completeas ordered by EIC/SIC. |
| 9 | Butt hinge : S & F of 75 mm long butt hinges medium weight cold rolled mild steel and fixed as ordered by EIC/SIC. |
| 10 | Plain sheet : M & L for plain2.5 mm thick mild steel sheeting, for the preparation of opening cover of valve chamber, door shutter, ridges, hips,etc. drip and straight flashings to be welded with angle flat etc. complete as ordered by EIC/SIC . |
| 11 | Reinforcement : M & L for providing reinforcementwork with TMTmild steel bars 08 mm and over, cut to length, bent to shape required, including cranking, bending, hooking ends & binding with mild steel wire (annealed) not less than 0.9 mm dia. etc.complete as ordered by EIC/SIC |
| 12 | M.S. Grill and windows : M & L for providing M.S ornamental grill with square/ rectangle bars and ends of bars shoulders and/or riveted or forged, welding into spikes etc. and steel windows of standard specification hanged with capsule hinge and window locks, fixed in position complete as ordered by EIC/SIC. |
| 13 | MS small articles : S & F for providing mild steel straps, clamps, chain, hold fasts; heavy-duty capsule hinges railing of staircase etc, as small articles, to be fixed in position as required as ordered by EIC/SIC. |
| 14 | MSwork: M & Lfor providing rolled mild steel angle, tee, flat, channel, joistetc. sections, erection, fabrication & fixed independently at any position as ordered by EIC/SIC. |
| 15 | MSPlate: S & F ofmild steel plate (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,including fabrication and erection with roof truss or foundation platein proper position complete as ordered by EIC/SIC. |
| 16 | Pre-colour coated steel sheet: S & F pre-painted galvalume aluminium zinc coating GI based corrugated /plain steel sheet of reputed make for ridge etc 0.50 mm thick (total coated thickness) of any colour having tensile (yield) strength of 550 mpa minimum, coated with aluminium zinc (az 150) @ 150 gm/sqm of coating (total both surfaces) as in roof covering / cladding to wall, ridges etc. fixed with self-tapping screws as specified & as directed by the EIC/SIC. |
| 17 | Neat cement finish : M & L for applying cement slurry about 1.5 mm thick on plastered or concrete surface to have the surfaces even & smooth as ordered by EIC/SIC. |
| 18 | Cement plaster(1:6): M & L for providing 12 mm thick cement plater 1:6 mix on fair faces of brick work or concrete surfaces at any height as ordered by EIC/SIC. |
| 19 | Sheet glass : M & L for providing sheet glass 3 mm thickness, of any size and shape, any height glazed with oil puttyof approved makeall complete and all as ordered by EIC/SIC. |
| 20 | Steel painting : M & L for applying two coats of synthetic enamel paint finished glossy of 1st quality; make: Asian / Berger / ICI or substantially equivalent make and approvedshade over a coat of priming with red lead primerafter necessary preparation of new decorated steel surfaces of any description over 10 cm width or girth as ordered by EIC/SIC |
| 21 | DI /CI Bend, Tee etc: Providing and laying / or welding in the existing line if required upto 300 mm dia. S&S C.I. standard specials / all fittings such as bend, Tee, collars, flange, tapers, caps, adopter, nut bolt, connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth etc. (heavy class) whichever is required complete as per requirement and direction of Engineer-in-charge. |
| 22 | Rubber or fibre board gasket Joint:M & L for making rubber or fibre board gasket joint in 150mm dia flanged pipe complete as per requirement and direction of Engineer-in-charge |
| 23 | Cutting cast iron pipes of 150mm dia: Labour only for cutting cast iron pipes of 150mm diafor insertion of new tees, valves, branches, etc complete as ordered by EIC/SIC. |
| 24 | LDPE pipe: S & F of 40 mm bore dia Low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenches or fixed in proper position for protection of submersible cable including all pipe fittings laying in trenches and also cutting, screwing and waste. complete as ordered by EIC/SIC. |
| 25 | PVC pipe 15 mm dia : S & F of 15 mm bore dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf / sqcm of reputed make laid or fixed in proper positionincluding all pipe fittings laying in trenches and also cutting, screwing and waste. complete as ordered by EIC/SIC. |
| 26 | Bib taps : S & F Bib taps of PTMT, any colour high pressure screwed forpipe or for brass ferrule(Minimum weight 15mm-90gms/20mm-125gms) and fixed, size of tap 15 mm bore dia. as ordered by EIC/SIC. |
| 27 | Stop valves 20mm dia: S & F of 20 mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutchor butterfly handle, screwed both ends for iron pipe or for unions and fixedof reputed make in proper position complete as ordered by EIC/SIC. |
| 28 | Ferrules 15mm dia.: S & F of straight 15mm dia plain brass ferrules (or connecting screws) screwed both ends and fixed after taking out old one complete as ordered by EIC/SIC. |
| 29 | Single brick flat soling : M & L for providing single brick flat soling with well burnt soling brick including filling of interstices with white sand as ordered by EIC/SIC. |
| 30 | Dismantling of brick work: Dismantling brick work or stone/boulder masonry of any typebuilt in cement morter including all quoins, arches, pillars etc as order by EIC/SIC. |
| 31 | Demolition of PCC : Labour only for demolition of cement concrete of any description and in any position and removing the same out off the work site as ordered by EIC/SIC. |
| 32 | Demolition of RCC : Labour only for demolition of reinforcedcement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position and removing the same out off the work site as orderd by EIC & SIC. |
| 33 | Dismantling steel work : Labour only for dismantling wrought iron or mild steel work of any description and in any position and removing the same to store or as directed by the EIC/SIC. |
| 34 | Supply and laying of reinforced precast concrete cable cover class LV, type-1 flat size 300mmx180mmx40mm for protection of underground cables, pipes,etc. all as ordered. |
| 35 | Supply and laying of reputed make Cables make XLPE insulated screened PVC bedded galvanised strip & wire armoured electric power cable (heavy duty) 1100 Volt grade with standard aluminium conductor of size 50 sq mm 3.5 core complete all as ordered. |
| 36 | DI Pipe: M & L for ductile iron pressure pipe 150 mm dia (including required nos. of 150mm dia bend and Tee in the line) centrifugally cast with socket & spigoted end Class K-9, ISI marked duly embossed suitable for (push on joint) rubber gusket D joining with inside cement mortar lining outside zinc coating with bitumen finishing layer including joining materials and making good the disturbed surfaces of roads, path ways etc complete as per requirement and direction of Engineer-in-charge. |
| 37 | Sluice valve 100mm dia: M & L forSluice valve with flanged ends of class PN 1.6 of size 100mm dia bore and fixed the same with the existing pipe line after dismantling / taking out the old damaged sluice valve ( if any ) completeas per requirement and direction of Engineer-in-charge. |
| 38 | Reflux valve 150mm dia: M & L forValve reflux with bypass arrangement supplied and installedof size 150mm dia bore and fixed the same with the existing pipe line complete( including all such as Adopters , Tail pieces , Flanges nut bolts rubber gaskets etc. whichever is required) as per requirement and direction of Engineer-in-charge |
| 39 | Sluice valve 150mm dia: M & L for Sluice valve with flanged ends of class PN 1.6 of size 150mm dia bore and fixed the same with the existing pipe line complete (including all such as Adopters, Tail pieces, Flanges nut bolts rubber gaskets etc. to connect the new valve in the existing pipe line after cutting the pipe line or after replacement of existing old sluice valve whichever is required) as per requirement and direction of Engineer-in-charge. |
| 40 | Boring/drilling up to 90m depth:M & L for Boring/drilling& reaming bore well of 400 mm dia. (max.) in all types of soil including rocky strata , Boulders etc.for casing pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 41 | Boring / drilling up to 150m depth: M & L for Boring/drilling & reamingbore well of 400 mm dia (max.) in all type of soil including rocky strata , Boulders etc. for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. |
| 42 | Lowering PVC vertical casing pipe: Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 150 mm nominal dia. conforming to IS: 12818, Schedule 80 [Make: Oriplast/Supreme/Finolex or substantially equivalent make]including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. |
| 43 | Lowering PVC vertical casing pipe: Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 200 mm nominal size dia. conforming to IS: 12818, Schedule 40; [Make: Oriplast/Supreme/Finolex or substantially equivalent make] including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge |
| 44 | Lowering unplasticized PVC medium well screen (RMS) pipes: Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes 150 mm nominal size dia. with ribs, conforming to IS: 12818, [Make: Oriplast/Supreme/Finolex or substantially equivalent make of best quality] including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 45 | 100 mm dia GI pipe: Supplying, assembling, lowering and fixing in vertical position in bore well, heavy duty GI column pipe of 100mm dia. for 3mtr. long with flanged ends including provisioning of GI flanged heavyduty. Flanged joining with joining material by welding, bolts, nuts, washers and rubber/fibre board gasket all including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. |
| 46 | Gravel packing: M & L for Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, NOTE: After gravel shrouding up to the sand layer is to be tapped, cement cealing is recommended for 2-3 metre thickness against the impermeable clay zone just above the tapped sand zone all complete as per direction of Engineer-in-charge. |
| 47 | Water meter: Providing and fixing enclosed type water meter 100mm dia. conforming to IS : 2373complete with bolts, including gate valve, nuts, rubber insertions etc all complete as per direction of Engineer-in-charge. |
| 48 | Development of tube well: M & L for Development of tube well in accordance with IS : 2800 (part I) and IS: 11189 with compressed air after with 25% extra capacity pump by pumping muddy water all complete as per direction of Engineer-in-charge. |
| 49 | Yield test: M & L for Yield test for the bore well by continuously pumping for 16 Hrs to determine safe pumping yield all complete as per direction of Engineer-in-charge. |
| 50 | Bail plug, well cap etc.:M & L for reducers, bail plug, well cap, MS strip for centering, MS iron clamps, electric logging and sample strata box etc. complete all. |
| 51 | Submersible Pump:Supply and installation of non-clog vertical submersible pumps of 20 H.P of KSB/ Kirloskar/ Crompton or substantially equivalent [Duty (Flow: 1250 LPM and Head: 40M ] with chrome steel impeller and cutter, non-clog to pass 40mm size particles including supply installation with guide rail and lifting chain cables earthing testing complete with 2 year maintenance all complete as per direction of Engineer-in-charge |
| 52 | Ceiling Fan: Supply and fixing of reputed Make ceiling fan 1400mm sweep,1ph,230V complete all as ordered by EIC |
| 53 | Panel board: Supply, installation, commissioning and testing cubical type LT panel board of suitable size, indoor canopy type, manufactured by CPRI approved factory, floor mouted, dust & vermin proof, front and rear operated door with locking arrangement made of iron frame work and CRCA sheet of 2 mm thick duly painted with two coats of powder coated paint both internally and externally. The panel shall be suitable for 415V,50Hz, 3ph 4 wire system and shall be complete with suitable capacity copper busbar (1.5 times the incoming switchgear current rating) with suitable size PVC insulated copper conductors, thimbles ,cable glands all as ordered by EIC. Incoming:(a) MCCB,4pole,TPN,415V,50Hz,25KA,63A fixed magnetic setting, Make - L&T/ Siemens / Havells /ABB or substantially equivalent make.-01 no. Outgoing: (b) MCCB,4pole,TPN,415V,50Hz,25KA,63A fixed magnetic setting, Make- L&T/ Siemens / Havells /ABB or substantially equivalent make.-01 No.(c) MCCB,4pole,TPN,415V,50Hz,16KA,32A fixed magnetic setting, Make- L&T/Siemens/ Havells/ ABB or substantially equivalent make-01 No.(d) Panel mounted star delta type submersible pump starter of capacity 20 HP with contactor, overload relay, single phase preventor suitable for 20 HP capacity submersiblepump set- 01 W/Job. (e) Interconnection of MCCB & Starter with bus bar,star delta starter to MCCB, single phase preventor and other electrical components- 01 W/job.(f) Timer switch with necessary electrical component and circuit for auto ON/OFF operation of submersible pump at pre-set timing complete all as ordered.- 01 W/Job.(g) Digital multifunction meter measuring current, voltage, energy, power factor with CTs,etc. for 63A outgoing MCCB.- 01 W/Job (h) Digital Voltmeter and Ammeter with CTs, etc. for 63A incoming MCCB.- 01 W/Job (i) Cable glands and lugs for incoming and outgoing cables.(j) Set of indication lamps(R,Y,B)-01 set. |
| 54 | Supply and laying reputed make submersible flat cable PVC insulated and pvc sheathed LT 1100Volts grade with copper conductor of 10 sqmm 3 core complete all as ordered. |