Tender For Certain Repair / Replacement And Maintenance Of Cooling Appliances, Ac Plant And Other Allied Works At Porbandar Under Ge Navy Porbandar, porbandar-Gujarat

Military Engineer Services-MES has published Tender For Certain Repair / Replacement And Maintenance Of Cooling Appliances, Ac Plant And Other Allied Works At Porbandar Under Ge Navy Porbandar. Submission Date for this Tender is 22-02-2024. AMC of Air Condition Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

41821953
Corrigendum : Tender For Certain Repair / Replacement And Maintenance Of Cooling Appliances, Ac Plant And Other Allied Works At Porbandar Under Ge Navy Porbandar
Open Tender
Indian
Gujarat
porbandar
22-02-2024

Tender Details

Certain Repair / Replacement And Maintenance Of Cooling Appliances, Ac Plant And Other Allied Works At Porbandar Under Ge Navy Porbandar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CERTAIN REPAIR / REPLACEMENT AND MAINTENANCE OF COOLING APPLIANCES, AC PLANT AND OTHER ALLIED WORKS AT PORBANDAR UNDER GE NAVY PORBANDAR
Sl. No. Item Description
1Labour for servicing of Window AC"supto 1.50 Tonne capacity of any make, complete health check-up of the unit and carrying out 2 dry & 1 wet serviceby removing dust with blower, complete cleaning ofunit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making theAir conditioner fully functional & serviceablecomplete all as specified & directed by Engineer-in-Charge.
2Labour for servicing of split AC"supto 1.50 Tonne capacity of any make, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet serviceby removing dust with blower, complete cleaning ofouter & indoor unit using cleansing solution ,soap /water, checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
3Labour for servicing of split AC"s of 2.0 Tonne capacity of any make , complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet serviceby removing dust with blower, complete cleaning ofouter & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
4Labour for servicing of Cassette AC"s of capacity2.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet serviceby removing dust with blower, complete cleaning ofouter & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
5Labour for servicing of Cassette AC"s of capacity3.0 Tonne, complete health check-up of the unit indoor /outdoor and carrying out 2 dry & 1 wet serviceby removing dust with blower, complete cleaning ofouter & indoor unit using cleansing solution ,soap /water checking all connections , Lubrication of fan motor and other parts as and when required and identifying faults and making the split AC fully functional complete all as specified & directed by Engineer-in-Charge.
6Note for item No. 1.00 to 5.00:- (a) The above item includes labour charges tools/gaugesfor Major and Minor repairs including Overhaulsb) Labour charges for all unlimited Breakdown Complaintsfor a period of one year c) Preventive Maintenance 3 visit in a year (qtrly based ) to carry out 2 dry & 1 wet serivicefrom LocalAuthorisedService Centre as approved by GE (b)The cost of spares such as Fan Motor/Louver Motor/ Gas Charging/ Capacitors & Relay/Thermostat Switch / Selector Switch / Air Filter / Remote Control / Fan & Blower / Evaporator and Condenser coil / Air Deflector /louvers/compressorwill be measured & paid separately under relevant item of the schedule.
7Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the window type air conditioner of 1.5 Ton capacity complete all as specified and directed.
8Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the splittype air conditioner upto 1.5 Ton capacity complete all as specified and directed.
9Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the splittype air conditioner of 2.0 Ton capacity complete all as specified and directed.
10Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 2 Ton capacity complete all as specified and directed.
11Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh mafron gas/R-22/ F-134A / R-32as per requirement and commissioning and testing the Cassette type air conditioner of 3 Ton capacity complete all as specified and directed.
12M&L for dismantling of indoor,outdoor unit ofSplit AC of any make , capacity complete from existing location and fixing it to a new location,making all connections , makinggood of old location, complete testing & commisioining all as specified & directed by Engineer-in-Charge.
13S& F in replacement of air conditioner outdoor unit stand consisting of wall brackets with fasteners suitable for all brands air conditioner outdoor units, Load carrying capacity for 2 ton outdoor unit , Rust proof sturdy design in powder coated metal with accessories for installation complete all as specified and directed.
14M& L for taking down AC to workshop & replacement unserviceable rotary compressor suitable for window air condtioner of capacity upto 1.5 TR , fixing,assembling & refixing AC back to location complete testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge ,& complete all as specified and directed.
15M& L for taking down outdoor , indoor unit ofAC to workshop & replacement unserviceablerotary compressor suitable for splitair condtioner of capacity upto 1.5 TR , fixing ,assembling & refixing of AC back to location complete, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed.
16M& L for taking down outdoor , indoor unit ofAC to workshop & replacement ofrotary compressor suitable for splitair condtioner of capacity 2.0TR, fixing ,assembling & refixing of AC back to location complete, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed.
17M& L for taking down outdoor , indoor unit ofAC to workshop & replacement ofrotary compressor suitable for Cassette of capacity upto 3 .TR , fixing ,assembling & refixing of AC back to location , testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed. Note for Item No. 13.00 to 16.00 :- (i) Rate is inclusive of compressor & required gas charging. (ii) Contractor will submit Warrenty for new Compressor from company.
18S& F in replacement of blower motor suitable for split type Air conditioner upto 1.5 Ton capacitycomplete all as specified and directed.
19S& F in replacement of blower motor suitable for split type Air conditioner 2.0 Ton capacitycomplete all as specified and directed.
20S& F in replacement of louver motor suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
21S& F in replacementof thermostat switch,sensor suitable for split type Air conditioner upto 2.0 Ton capacity complete all as specified and directed.
22S& F in replacement of PCB circuit boards suitable for split type Air conditioner upto 2.0 Ton capacitycomplete all as specified and directed.
23S& F in replacement of display PCBsuitable for split type Air conditioner upto 2.0 Ton capacitycomplete all as specified and directed.
24M& L for taking down indoor unit ofAC to workshop & replacement ofevaporator coilsuitable for split type Air conditioner upto 1.5Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioningall as specified and directed by Engr-in charge
25M& L for taking down indoor unit ofAC to workshop & replacement ofevaporator coilsuitable for split type Air conditioner 2.0Ton capacity fixing ,assembling & refixing of AC back to location testing for good cooling & smooth functioningall as specified and directed by Engr-in charge
26S& F in replacement of blower suitable for split type Air conditioner upto 2.0 Ton capacity completeall as specified and directed by Engr-in charge
27S& F in replacement of remote handset with cellsuitable for split type Air conditioner upto 2.0 Ton capacity completeall as specified and directed by Engr-in charge
28S& F in replacement of outdoor unitfan motor from window / splittype AC of capacity 1.5 / 2 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
29M& L for taking down outdoor , indoor unit ofAC to workshop & replacement of condensor coilsuitable for split type Air conditioner upto 1.5Ton capacityfixing ,assembling & refixing of AC back to locationtesting for good cooling & smooth functioningall as specified and directed by Engr-in charge
30M& L for taking down outdoor , indoor unit ofAC to workshop & replacement of condensor coilsuitable for split type Air conditioner 2.0 Ton capacityfixing ,assembling & refixing of AC back to locationtesting for good cooling & smooth functioningall as specified and directed by Engr-in charge
31S& F in replacement of suction/discharge valve suitable for split type Air conditioner 2.0Ton capacitycomplete all asdirected by Engr-in charge
32S& F in replacement ofcapilary tube filter set suitable forair conditioner upto 2 TR capacitycompleteiall as specified and directed by Engr-in charge
33S& F in replacement of fan blade suitable for window/split type Air conditioner of1.5 Ton capacitycomplete all as specified and directed.
34S& F in replacement of fan blade suitable for window/split type Air conditioner of 2.0 Ton capacitycomplete all as specified and directed.
35S& F in repairof PCB circuit boardsfor split type Air conditioner upto 2.0 Ton capacitycomplete all as specified and directed.
36S& F in replacement of PCB circuit boardsfor inverter split type Air conditioner upto 2.0 Ton capacitycomplete all as specified and directed.
37S& F in replacementcapacitor upto 3 MFD 230 volts, 50 Hz, type suitable for window/splitair conditioner of capacity upto 2TR complete above completeall as specified and directed by Engr-in charge
38S& F in replacementcapacitor above 3 MFD & upto 60 MFD 230 volts, 50 Hz, type suitable for window/splitair conditioner of capacity upto 2TR complete above completeall as specified and directed by Engr-in charge
39S& F in replacementselector switch rotary type with knob, suitable for window air conditioner of capacity upto 2TR complete all as specified and directed by Engr-in charge
40S& F in replacementPVC front grill suitable for window type room AC of make Carrier/Voltas/Usha suitable completeall as specified and directed by Engr-in charge
41S& F in replacement return air filter made of PVC suitable for windowair conditioner of capacity upto 2TR complete mentioned above completeall as specified and directed by Engr-in charge
42S& F in replacementof magnetic contactor 240V 26/20A 440V, 50Hz suitable for split ac 1.5/2type & capacity fixed in complete all as specified and directed.
43S& F in replacementoffoam heat insulating flexible hollow tubefor suction and dischargetubes of 1.5/2 Ton capacity split AC complete all as specified and directed.
44S& F in replacement3 core X 1.5 Sqmm PVC insulated and FR PVC Round sheathed, copper conductor, flexible industrial cable,1100 V conforming to IS :694all as specified and directed by Engr-in charge Make: Standrad/Polycab/Finolex
45S& F in replacement3 core X 2.5 SqmmPVC insulated and FR PVC Round sheathed, copper conductor, flexible industrial cable,1100 V conforming to IS :694all as specified and directed by Engr-in charge Make: Standrad/Polycab/Finolex
46S& F in replacement6A, 240V, 3Pin Plug topall as specified and directed by Engr-in charge.
47S& F in replacement16A, 240V, 3Pin Plug topall as specified and directed by Engr-in charge.
48S & F in replacement of earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp,flush mounting typeall as specified and directed by Engr-in charge.
49S& F in replacementPVC pipe 20 mm dia heavy duty inclusive of all tees,bends, elbows etc & fixing accessories for drain out condensing water of split AC including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surface complete.
50S & F in replacement ofPVC pipe 25 mm dia heavy duty inclusive of all tees,bends, elbows etc & fixing accessories for drain out condensing water of split AC including cutting of floor/opening of hole in wall and making good after laying of pipe etc to match the existing surface complete.
51S & F in replacement of clamping jointing copper tubing of size 1/4",1/2", 3/8" ,5/8" for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
52Repairs to refrigerator of capacity upto 240 Ltr of any makeby taking down unserviceable compressor , S&F hermatically sealed compressor with Relay and OLP unit, mounting bushsuitable for above mentioned capacity refrigerator with one year warranty, fixing & assembling in refrigerator ,vacuming andgas charging with R-134a /Hydrocarbon gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning to the satisfaction of Engr-in-charge etc complete all as specified and directed.
53Repairs to refrigerator of capacity above 240 & upto 320 Ltr of any makeby taking down unserviceable compressor , S&F hermatically sealed compressor with Relay and OLP unit, mounting bushsuitable for above mentioned capacity refrigerator with one year warranty, fixing & assembling in refrigerator ,vacuming andgas charging with R-134a /Hydrocarbon gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning to the satisfaction of Engr-in-charge etc complete all as specified and directed. Note for Item No. 51.00 to 52.00 :- (i) Rate is inclusive of compressor & required gas charging. (ii) Contractor will submit Warrenty for new Compressor from company.
54S & F in replacementof open type relay with Over load protector suitable for refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
55S & F in replacementofthermostatic switch defrost type including plastic regulating knob suitable refrigerator of capacity upto 320 Ltr all as specified and directed by Engr-in charge
56S & F in replacementof set of copper strainer with silica filter suitablerefrigerator of capacity upto 320 Ltrall as specified and directed by Engr-in charge
57S & F in replacementofcapillary tube 0.036"" maximum suitablerefrigerator of capacity upto 320 Ltrall as specified and directed by Engr-in charge
58S & F in replacementofrunning capicitor , Cap 4 MFD suitable for refrigerator .Make : Epcosall as specified and directed by Engr-in charge
59S & F in replacementofrunning capicitor , Cap 6 MFD suitable for refrigerator .Make : Epcosall as specified and directed by Engr-in charge
60S & F in replacementofrunning capicitor , Cap 10 MFD suitable for refrigerator .Make : Epcosall as specified and directed by Engr-in charge
61S & F in replacementofcondensor coil suitablerefrigerator of capacity upto 320 Ltr, fitting & assembling in refrigerator and including gas charging with R-134a /HydrocarbonR600aas per pressure and quantity recommended by the company,testing for good cooling and smooth functioning all as specified and directed by Engr-in charge
62S & F in replacementof evaporator /cooling coil with frame suitablerefrigerator of capacity upto 320 Ltr, fitting & assembling in refrigerator and including gas charging with R-134a/Hydrocarbon R600a gas per pressure and quantity recommended by the company, testing for good cooling & smooth functioning all as specified and directed by Engr-in charge
63S & F in replacementof non return valve suitable for refrigerator/Watercooler/Deep freezer all as specified and directed by Engr-in charge
64Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the refrigerator upto 320 Ltr capacity complete all as specified and directed.
65Repairs to Deep freezer of capacity upto 400 Ltr of any type & make by taking down unserviceable compressor and S&F New hermetically sealed compressor with Relay and OLP unit suitable for above mentioned capacity with one year warranty , fixing & assembling in deepfreezer complete with welding /brazing and gas charging with R-134a gas as per the pressure and quantity directed, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed. Note:- (i) Rate is inclusive of compressor & required gas charging. (ii) Contractor will submit Warrenty for new Compressor from company.
66S & F in replacementof starting capacitor of capacity 80-100 Mfd suitable for deep freezer of capacity upto 400 Ltr completeall as specified and directed by Engr-in charge.
67S & F in replacementofthermostat switch suitable for deep freezer suitable for deep freezer of capacity upto 400 Ltrcompleteall as specified and directed by Engr-in charge
68S & F in replacementof over load protector with relay and capacitor set suitable for deep freezer of capacity upto 400 Ltr completeall as specified and directed by Engr-in charge
69S & F in replacementof capillary tube 0.044"" diafor deep freezer suitable for deep freezer of capacity upto 400 Ltr complete all as specified and directed by Engr-in charge
70S & F in replacementofcopper strainer silica filter for deep freezer suitable for deep freezer of capacity upto 400 Ltr completeall as specified and directed by Engr-in charge
71S & F in replacementof fan motor condenser 230 volts, 8 to 10 watts suitable for deep freezer of capacity upto 400 Ltr completeall as specified and directed by Engr-in charge
72Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the Deepfrezzer upto 400 Ltr capacity complete all as specified and directed.
73Repairs to Water Coolerof capacity of any type & make by taking down unserviceable compressor and S&F New hermetically sealed compressor with Relay and OLP unit suitable for water coolerwith one year warranty , fixing & assembling in water cooler complete with welding /brazing and gas charging with R-134a gas as per the pressure and quantity directed, testing for good cooling and smooth functioning to the satisfaction of Engr-in-charge , complete all as specified and directed. Note:- (i) Rate is inclusive of compressor & required gas charging. (ii) Contractor will submit Warrenty for new Compressor from company.
74S & F in replacementof pencil drier type strainer suitable for water cooler of any type& capacity complete all as specified and directed by Engr-in charge
75S & F in replacement of Box type Relay with over load protector suitable for water cooler of any type& capacity completeall as specified and directed by Engr-in charge
76S & F in replacement of running capacitor upto 15 MFD 230 Volts AC 50 Hz suitable for water cooler of any type & capacity complete all as specified and directed.
77S & F in replacement of starting capacitor upto 40-60 MFD230 volts , 50 Hz suitable for water cooler of any type & capacity complete all as specified and directed.
78S & F in replacementof thermostat switch with plastic regulating knob suitable for water cooler of any type& capacity complete all as specified and directed by Engr-in charge
79S & F in replacementoffan motor capacity 1/35 HP of condenser suitable for water cooler of any type& capacity complete all as specified and directed by Engr-in charge
80S & F in replacementoffloat valve 15 mm bore dia complete with PVC ball ,brass chromium plated rodsuitable for water cooler mentoned above completeall as specified and directed by Engr-in charge
81S & F in replacementofPVC connection pipe, type 15 mm dia 450 mm long complete with PVC union at both end suitable for water cooler of any type& capacity completeall as specified and directed by Engr-in charge
82S & F in replacementofPVC flexible connection pipe high density 32 mm dia including jublee clamps ouutlet connection for drain water suitable for water cooler of any type& capacity complete all as specified and directed by Engr-in charge
83S & F in replacementofspring loaded self closing water tap ( push type) 15 mm bore dia , internal theaded , brass chromium platedsuitable for water cooler of any type& capacity completeall as specified and directed by Engr-in charge
84S & F in replacementof spring loaded self closing water tap ( push type) 15 mm bore dia, External threaded , brass chromium platedsuitable for water cooler of any type& capacity completeall as specified and directed by Engr-in charge
85Material and labour for Detecting the gas leakage, using nitrogen & soap solution, rectifying the defects by sealing the leakage by brazing/repair of part, vacumizing and charging fresh gas/R-22/ F-134A / R-32 as per requirement and commissioning and testing the watercooler of any capacity complete all as specified and directed.
86S & F in replacement filter catridge suitable upto 25 ltrs RO Plant including taking out old filter cartridge complete all as specified and directed.
87S & F in replacement filter catridge suitable for 50 ltrs RO Plant including taking out old cartridge complete all as specified and directed.
88S & F in replacement RO memebrane suitable upto 25 ltrs RO Plant including taking out old RO membrane complete all as specified and directed.
89S & F in replacement RO memebrane suitable 50ltrs RO Plant including taking out old RO membrane complete all as specified and directed.
90M&L for overhauling of compressor of capacity 40 TR of Make Voltas Model05046S complete all as directed for improved performance and designed parameteras specified including the following at AC plant:-(a) Pumping down the compressor and transfer existing refrigerent gas,complete dismantling of each part of compressor and replacing the defective parts as found and reassembling the complete compressor, then oil charging, and doingpressure test using N2 gas as specified& hold for 24 Hrs to detect leakage and again same tests after repairing the leakageto ensure no leakage in the complete system, after that vaccuming the compressor to remove moisture & air complete all as specified & directed by Engr-in-Charge.Note :- 1) Refrigerant Gas, Oil and spare parts etc will be measured and paid separately under relevent item of Schedule
91Supply and fix in repair/replacement of Crank shaftsuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
92Supply and fix in repair/replacement of Main Bearing Seal End (STD)suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
93Supply and fix in repair/replacement of Main Bearing Pump End (STD) suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
94Supply and fix in repair/replacement ofInsert Bearing (STD)suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
95Supply and fix in repair/replacement of Pump End brass Washer suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
96Supply and fix in repair/replacement of SealEnd BrassWasher suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
97Supply and fix in repair/replacement of Thrust Washer suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
98Supply and fix in repair/replacement of Shaft seal asslysuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
99Supply and fix in repair/replacement of Shaft seal cover platesuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
100Supply and fix in repair/replacement of Nylock Nutsuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
101Supply and fix in repair/replacement of Connecting Rod suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
102Supply and fix in repair/replacement of Piston suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
103Supply and fix in repair/replacement of Piston Pinsuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
104Supply and fix in repair/replacement of Comprression Ring suitable for Voltas compressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
105Supply and fix in repair/replacement of Oil Ring suitable for Voltas compressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
106Supply and fix in repair/replacement of Valve Plate suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
107Supply and fix in repair/replacement of Suction Valve Reed (Imp Micro Finish) suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
108Supply and fix in repair/replacement of DischargeValve Reed (Imp Micro Finish)suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
109Supply and fix in repair/replacement of DischargeValve Spring suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
110Supply and fix in repair/replacement of Suction Valve Spring suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
111Supply and fix in repair/replacement ofCylinder Sleevesuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
112Supply and fix in repair/replacement of Gasket Set (5H86)suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
113Supply and fix in repair/replacement of LockWashersuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
114Supply and fix in repair/replacement of Star Washer suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
115Supply and fix in repair/replacement of Oil pump assembly (5H-40/86) suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
116Supply and fix in repair/replacement of oil pump bush suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
117Supply and fix in repair/replacement of Suction pressure transducer suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
118Supply and fix in repair/replacement ofdischarge pressure transducer suitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
119Supply and fix in repair/replacement of IPS-1 USV COILsuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
120Supply and fix in repair/replacement of TC 19 TYPE RUBBER COUPLERsuitable for Voltascompressor Model05046S including dismantling old unserviceable part complete all as specified and directed by Engr-In-Charge.
121Supply & charging of compressor oil N68Suitable for R-22 Refrigerant Compressor of ModelVoltascompressor Model05046S model including draing out old oil complete all as specified & directed by Engr-In-Charge
122Supplyand charging of Refrigerant GasR 22 up to required pressure and quantity in AC plantNote:- Gas will be supplied in pack cylinder Complete in all respect all as specified & directed
123Supply and fix HP cutout switches suitable for Voltascompressor Model05046S including dismantling old unserviceable all as specified and directed by Engr-In-Charge. Make: Danfoss KP 1 /Indofoss.
124Supply and fix LP cutout switches suitable for Voltascompressor Model05046S including dismantling old unserviceable all as specified and directed by Engr-In-Charge. Make: Danfoss KP 1 /Indofoss or equivalnet it .
125Supply and fix HP/LP/OP gauges of range 0 to 150 Kg/cm2(R22) suitable for Voltascompressor Model05046S compressor model including dismantling old unserviceable all as specified and directed by Engr-In-Charge.
126Material and labour for disconnectingfor Chiller descaling & Plugging them & providing of 15 mm tee outlet for local circulation of mild acid solution in the Chiller (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be usedfor descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7, flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulatingdiluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for 2 x 40TR Capacity AC Plant at Hanger 343 of NAE Porbandar.
127M&L for detection of leakage using Nitrogen gas at AC Plant in Refrigerant Line , Evaporator Coil /colling coil using proper pressure test after completion of overhauling of compressor as per Sl item No 89.00, detecting the leakage as per standard procedure & attending the repair complete in all respect by bronze soldering stick with gas weldingor any other suitable measure & Vaccuming the same after Nitrogen test all as specified and directed by Engr-In-Charge
128Material and labour for disconnecting condenser for descaling & plugging them & providing of 15 mm tee out let for local circulation of mild acid solution in the condenser (separate container and small pump set to circulate diluted acid solution to be used) PH value of solution to be circulated & to be kept 4 and checking frequently i.e. every one hour during the operation Scalgun WS solution to be usedfor descaling purpose after 2 to 3 hours of cleaning if ph value remains less than 7 flush with fresh water mixed with sodium carbonate tubes and cleaning with nylon brush after closing the end covers, circulatingdiluted acid solution as specified above & PH value to be maintained as above & flushing the same with fresh water including recharging of stored refrigerant up to required pressure complete all as specified & directed by Engineer-in-Charge of for 2 x 40TR Capacity AC Plant at Hanger 343 of NAE Porbandar.
129Material and labour for Dismantling AHU of 2 x 40TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specifiedanddirected at Hanger 343 of NAE Porbandar.
130Material and labour for cleaning of cooling coil section of AHUfor descaling and providing 2 Nos. 15 mm Tee outlet for local circulation of mild acid solution in the cooling coil (separate container and pump set of appropriate capacity to be used for circulation) PH value of Zem solution to be kept at 4 & checked at an interval of 1hr. duration process the scalgum / WS / Cleansol orequivalent solution to be used for descaling if ph value remains less than "7" flush with fresh water addedto sodium carbonate till ph value attains "7" refix the coilsection in position minor repairs to be carried out in AHU Coil bins to be cleaned by scalgum solution by spraying the solution with washing pump up to required level, AHU and complete all as specified and directed forAHU of 2 x 40TR Capacity AC Plant at Hanger 343 of NAE Porbandar.
131Overhauling of CT fan motor ofDelta cooling Tower capacity 50 TRafter removing from the base plate,dismantling, replacing unserviceablebush /bearing /minor partsfor repair purpose including cleaning,varnishing ,insulation replacement of bearings and greasing etc. complete and reassembling the same for smooth functioning complete suitable for AC plantall as specified & directed
132Rewinding ofunserviceable electric motor 3 phase 50 Hz 415volt of 5 to 10 HP capacity pump set complete comprises as under :- (a) Disconnecting& removing the electric motor from installed position including, loading, unloading and transporting to approved workshop. (b) Taking out the existing burnt winding from the motor including rewinding complete with super enameled copper winding wireofexisting gauge including all insulating material such as insulation paper, sleeves, tape, varnish etc. completefor class "F" insulation. (c) Transporting the motor back to the location, reinstalling in original position including alignment, electrical & water connection, commissioning and testing for 8hours continuously to check the RPM etc. to the satisfactory performance etc. complete. NOTE: Any damage caused during handling will be made good without any extracost to department
133M & L for Over hauling of Monoblock pump of 5 to 10HPcapacity set after removing from the base plate, disconnectingfrom pipe line, dismantling the pump set, replacing unserviceable gland packing, gun metal bush bearing water seal applying grease etc. complete and reassembling the pump set connecting with pipe line reconnection of electric supply, including buts bolts, gaskets etc. complete testing of pumps for smooth functioning with following capacityof pumps
134S& F single phase preventor for motor protection with selectable ON delay & OFF delay Make :- Minilek/equivalent it.
135S & F 3 Pole power contactor conforms to IS /IEC 60947-47-1,type MNX 70 .MakeL& T/ Legrand/Schenider
136S & F 3 Pole power contactor conforms to IS /IEC 60947-47-1,type MNX 80 .MakeL& T/ Legrand/Schenider
137S & F Add -on aux contact block 2NO+2NCtype MNX -A1 .MakeL& T/ Legrand/Schenider
138Material and labour for Repairs/Replacement Expansion valve of 40TR chiller unit complete all as specified and directed by Engineer-in-Charge.
139Supply & lay PVC insulated, FR PVC Round sheathed , copper conductor (flexible) industrial cable, 1100 Volt, conforming to IS:694 of size 16 Sqmm x 3core complete all as specified and directed by Engr-In Charge. Make:-Polycab/Standard/Finolex Note: Rate is inclusive of cable gland & cable lugs, Cable saddle/ties etc
140M & L for securing the duct insulation with aluminium sheet of size 28 gauge for outer exposed area and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr including taking down old unserviceable sheet complete all as specifed & directed.
141Supply, install, testing and commissioningCable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric undergroundpower cablewith stranded aluminium conductor cross sectional area 120 sqmm 3.5 core suitable for working on 1100 Volts, laid in tranches, in floor, in ducts, through pipe or along polecomplete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipeshall be measured and paid for separately.
142Supply & fixSheet metal enclosure suitable to accommodate MCCB125 Amps 4 pole, upto 185 sqmm 3.5 core cable . Make L&T cat No CM91003OOOO /schenider/Legrand
143Suply & Fix MCCB 125 Amps 4 Pole 25 ka with thermal magnetic release complete allas specified and directed.Make L&T Desine series /schenider/Legrand
144Double Walled Corrugated (DWC) HDPE pipe of size 90 mm outer dia and 75 mm inner dia conforming to IS 16205 Part -24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N throughtrenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In-Charge.
145Excavation intrenches in hard /densesoil not exceeding 1.5 mtrdeep and not exceeding 1.5 mtrwide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
146Returning, filling in including spreading, leveling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, all as specified and directed at site
147Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
148M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipeall as directed
149M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed.