| 1 | Supplying and Layingof 3.5Cx300 Sq mmsizeXLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with 40x3mm MS flat clamp etc. complete as required at site (Make-Polycab/Universal/ Grandlay/Gloster) |
| 2 | Supplying and Layingof 3.5Cx185 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 in the existing RCC/ HUME/ METAL pipe as etc complete as required at site (Make-Polycab/Universal/ Grandlay/Gloster) |
| 3 | Supplying and Layingof 3.5Cx120 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steelstrip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with 40x3mm MS flat clamp etc. complete as required at site(Make-Polycab/Universal/ Grandlay/Gloster) |
| 4 | Supplying and Layingof 3.5Cx95 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with 40x3mm MS flat clamp etc. complete as required at site (Make-Polycab/Universal/ Grandlay/Gloster) |
| 5 | Supplying and Layingof 3.5Cx70 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with40x3mm MS flat clamp etc. complete as required at site(Make-Polycab/Universal/ Grandlay/Gloster) |
| 6 | Supplying and Layingof 3.5Cx50 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with 40x3mm MS flat clamp etc. complete as required at site (Make-Polycab/Universal/ Grandlay/Gloster) |
| 7 | Supplying and Layingof 3.5Cx35 Sq mmsize XLPEinsulated ,PVC outer sheathed ,armoured with galvanised roundsteel wire or steel strip cables with stranded Aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS:7098 (Part-1) 1988 with ammendment No 1 on wall surface as clamped with 40x3mm MS flat clamp etc. complete as required at site (Make-Polycab/Universal/ Grandlay/Gloster) |
| 8 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 300 sq. mm (70mm) |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 95 sq. mm (45mm) |
| 12 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm) |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm) |
| 14 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm) |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(Make-M seal/Rachem/3M3½ X 185 sq. mm |
| 16 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(Make-M seal/Rachem/3M3½ X 120 sq. mm |
| 17 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(Make-M seal/Rachem/3M3½ X 95 sq. mm |
| 18 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required(Make-M seal/Rachem/3M3½ X 70 sq. mm |
| 19 | Supplying, Installation, testing & commissioning of wall mounted outdoor type with canopyCable junction box /Bus bar chamber having 400 Amps.capacity TPN copper bus bars of high conductivity with insulation support at both ends of each bus bar36 KA for 1 secondand minimum face area 0.533 Sq mtr suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply system with 6 nos Suitable size stud& nut on each bus bar for cable connection andfabricated Bus-BarChamber type tested assembly design having IEC code 61439 & IEC 61921 fabricated from 2 mm thick CRCA sheet steel i/c cleaning & finishing complete with powder coating in approved shade, the Bus-bar chamber /cable junction box shall be provided with 2 nos f earth stud at both side bottom etc complete as required at site (The rough sketch is enclosed herewith as Annexure A). |
| 20 | Providing and fabrication of 50mmx50mmx6mm thick angle iron frame as per site requirment with two coat of red oxide paint/primer including fixing on the existing wall for hanging/supporting theCable junction box /Bus bar chamberetc complete as required at site. |