Tender For Repair/Maintenance Of Dg Sets, Solar Water Heater And Comprehensive Maintenance Of Swimming Pool Under Ge Aanpur, Kanpur-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Dg Sets, Solar Water Heater And Comprehensive Maintenance Of Swimming Pool Under Ge Aanpur. Submission Date for this Tender is 31-01-2024. Diesel Generators Tenders in Kanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41802085
Tender For Repair/Maintenance Of Dg Sets, Solar Water Heater And Comprehensive Maintenance Of Swimming Pool Under Ge Aanpur
Open Tender
Indian
Uttar Pradesh
Kanpur
31-01-2024

Tender Details

Tender For Repair / Maintenance Of Dg Sets, Solar Water Heater And Comprehensive Maintenance Of Swimming Pool Under Ge Aanpur

Key Value

Document Fees
INR 500 /-
EMD
INR 85040.0 /-
Tender Value
INR 42.52 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINT OF DG SETS, SOLAR WATER HEATER AND COMPREHENSIVE MAINT OF SWIMMING POOL UNDER GE (I) KANPUR
Sl. No. Item Description
1Repair/servicing to complete DG set any make/modal 50/62.5/83 KVA water cooled diesel engine by taking out dismantling segregation of all parts and re-assembling after duly repair/ replacement of following new part fixing including all type machine work such as turning reaming etc, washing, cleaning, greasing , wires, replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site complete all as specified and directed. Note:- Any other accessories found unserviceable that shall be replaced & paid under respective items of this Sch.
2All as per item No 1 above but for DG Set of capacity 20 KVA in Cantt area complete all as specified and directed.
3S&F in replacement of Lub oil filter element for 50/62.5/83 KVA DG Set as per sample complete all as specified and directed
4S&F in replacement of Lub oil filter element for 20 KVA DG Set as per sample complete all as specified and directed
5S&F in replacement of Fuel filter element for 50/62.5/835 KVA DG Set as per sample complete all as specified and directed
6S&F in replacement of Fuel filter element for 20/ 50/62.5/83 KVA DG Set as per sample complete all as specified and directed
7S&F in replacement of Dry type air cleaner for 50/62.5/83 KVA DG Set as per sample complete all as specified and directed
8S&F in replacement of Dry type air cleaner for 20 KVA DG Set as per sample complete all as specified and directed
9S&F in replacement of V-Belt of fan for 20 to 83 KVA DG Set as per sample complete all as specified and directed
10S&F in replacement of manual type Governor Assy for 50/62.5/83 KVA DG Set as per sample complete all as specified and directed
11S&F in replacement of manual type Governor Assy for 15/20 KVA DG Set as per sample complete all as specified and directed
12S&F in replacement of Starting switch of DG set up to cap 50 to 83 KVA as per sample complete all as specified and directed
13S&F in replacement of Starting switch of DG set up to cap 20 KVA as per sample complete all as specified and directed
14M&L for replacement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc complete all as specified and directed.
15S&F in replacement of Gauge lube oil pressure of DG set cap 20 to 83 KVA as per sample complete all as specified and directed
16S&F in replacement of Hose pipe for of DG set cap 20 to 62.5 KVA as per sample complete all as specified and directed
17S&F in replacement of radiator hose pipe of DG set cap 20 to 83 KVA as per sample complete all as specified and directed
18S&F in replacement of Injector assy of DG set cap 50 to 83 KVA as per sample all as spfd.
19S&F in replacement of Injector assy of DG set cap 20 KVA as per sample complete all as specified and directed
20S&F in replacement of Clamp hose radiator of DG set as per sample complete all as specified and directed
21S&F in replacement of water body of DG set 50/62.5/83 KVA as per sample complete all as specified and directed
22S&F in replacement of Turbo charging kit assembly of DG set 50 to 83 KVA as per sample complete all as specified and directed
23S&F in replacement of self starter 12/24 volt for DG set 50 to 83 KVA as per sample complete all as specified and directed
24S&F in replacement of AVR (Anti Voltage Regulator) for DG Set of capacity 50 to 83 KVA as per sample complete all as specified and directed
25S&F in replacement of AVR (Anti Voltage Regulator) for DG Set of capacity 20 KVA as per sample complete all as specified and directed
26S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit as per sample for DG set 20 to 83 KVA as site requirment complete all as specified and directed.
27S&F in replacement of Rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24 /12 V DC full wave rectifier unit as per sample for DG set 20 to 83 KVA as site requirment complete all as specified and directed.
28Repair/Replacement of AMF Panelfactory made indoor type control cubical made out of 1.6mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etccomplete all as specified and directed.
29Repair/Replacement of AMF Panelfactory made indoor type control cubical made out of 1.6mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 15 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs 100 A and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etccomplete all as specified and directed.
30Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts , celebration for DG set of capacity 50 to 83 KVA & testing on completion complete all as specified and directed.
31Repair of(In line) fuel pump by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts , celebration for DG set of capacity 15 to 20 KVA & testing on completion complete all as specified and directed.
32Repair to radiator assy Cleaning washing throughly, descaling and M&L for replacement of rubber size paid and MS Nut & Bolts including brazing /repair of cooling tubeswith dismantling and segregation upper and lower chamber (tank) includingand reassembling complete incl nut, bolt, washers, & spring any type for DG set capacity 20 to 83 KVA complete all as specified and directed.
33Cleaning decarbonishing complete and spray painting to complete DG Set canopy outside of capacity 20 KVA to 62.5 KVA including writing SM No, Srl No, Make, capacity & date of installation as per sample all as directed.
34Disconnecting, dismentling & repair to Dynamo with segregation of all parts supply and fix in replacement of armature field, coil, carbon brush and bearing etc reassembling complete & testing on completion complete all as specified and directed.
35Repair to battery 12 volt180 Amps in replacement of battery cells consisting of – VE plates + VE plates and separators including make terminals block for cell connections and cell cover filling of electrolyte and recharging of battery complete.
36M&L for replacement of Coolant for DG set of make : Castrol/Indian Oil or equivalent complete all as specified and directed.
37M&L for replacement of Engine oil 20 W 40 complete all as spfd. make : Castrol/Indian Oil or equivalent complete all as specified and directed.
38Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set complete all as specified and directed.
39Supply and fixing in replacement of maintinance free battery 12 volt 150 AH 25 plate including battery leads and initial charging of battery.Make:Exide/Amron. complete all as specified and directed.
40Disconnecting, dismantling and repair/servicing to self starter 12/24 volt and replacement of field coil, carbon brush, bush or other unserviceable parts parts and refixing complete and testing after completion.
41M&L in replacement of microprocessor digital type DG set controller of DG set capcity 50 KVA to 62.5 KVA (Make of DG set- Greaves Cooton) including connect all control wiring& programming all the parameter related to DG set at sitecomplete all as specified and directed.
42M&L in replacement of microprocessor digital type DG set controller of DG set capcity 15 to 20 KVA (Make of DG set- Greaves Cooton) including connect all control wiring& programming all the parameter related to DG set at sitecomplete all as specified and directed.
43S&F in replacement of Automaticbattery chargerAC input 230 + 10% V output DC for 12/24 volt battery current 10-15 Amp for 01 No battery at a time with digital ammeter and voltmeter complete all as specified and directed.
44S& fin replacement ofBattery terminal bolt type suitable for any tpe of battery complete all as specified and directed.
45S& fin replacement ofBattery lead of copper conductor 35 Sqmm single core fitted with suitable terminal on both side complete all as specified and directed.
46M & L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc complete for DG set of capacity 50 to 83 KVA incl taking out the old burnt windings.
47M & L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge incl varnishing of insulating material and heating up, testing etc complete for DG set of capacity 20KVA incl taking out the old burnt windings.
48M & L in replacement of flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as directed.
49Supply poring of distilled water for maint of battries complete all as specified and directed.
50Servicing / maint of solar water heater system of capacity up to 750 ltr including dismantling the required parts after that de-scaling, cleaning of solar water (Absorber) tank, cleaning of pipe, air vent, eliminator etc and refixing the dismantled parts at its original position to make solar water heater functional complete by replacement of minor accessories and testing on completion all as spfd and directed.(i) Minor spares i.e nut, bolt, washers, wire or other minor parts if required shall deems to be included in this job. (ii) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch.
51S &F in replacement PVC hose pipe for Solar water heating system as per sample including clamps, washers, bolts etc where ever reqd.
52S&F in replacement of temperature sensor complete with connected fittings as per sample all as spfd and directed.
53S&F in replacement ofair vent assembly as per sample all as spfd and directed.
54S&F in replacement of drain assembly as per sample all as spfd and directed.
55S&F in replacement of shutt off valve as per sample all as spfd and directed.
56S & F 20 mm bore GI pipe medium grade ISI marked with all fittings and fixed to walls / roofs or laid in floors / plinth protection including making good disturbed surfaces with cement mortar (1:3) to match with existing surfaces complete all as specified and directed.
57M & L High density polyethylene (HDPE) pipes of pressure rating 6 kgf/sq. cm / Polypropylene Random Copolymer (PP-R) pipes with all fitting / fixture (for hot and cold water supply) fixure to wall / floor of 20 mm dia pipe.
58S & F 20 mm dia stop valve chromium plated cast copper alloy, fancy type high pressure with capstan head screwed both ends for iron / PP-R pipe or for union complete all as specified and directed.
59S& f in replacement of SolarFlat Plate CollectorSelective Black chrome with Nickel Undercoat absorber, Italian design, (screw less construction for durability) Copper riser tube dia 12.5mm x 0.55mm thick, 9 risers, Copper header tube dia 25.4 mm x 0.72mm thk x 1120 mm length, Toughened glass 4mm thick transmittance up to 87%, Aluminum-PU coated frame, Box Type Structure body, Glass wool and Rock wool insulation, Back Insulation - 50mm thick, Side Insulation - 25mm thick, 48 Kg/Mtr cube insulation density, Stainless Steel - SS 304L, having 6 bar pressure complete all as specified and directed. Make : V-Guard/Racold/Indo Solar Ltd
60S&F in relacement of SS-304 pressuized tank 200 Ltr and puff insulation 4 Kg /sqcm working pressure with MS standcomplete all as specified as diredted. Make : V-Guard/Racold/Indo Solar Ltd
61S&F in relacement of SS-304 pressuized tank 750 Ltr and puff insulation 4 Kg /sqcm working pressure with MS standcomplete all as specified as diredted. Make : V-Guard/Racold/Indo Solar Ltd
62S&F in replacement of ETC tube size 58mmx1800 mm solar water collector complete all as specified as diredted by Engr-in -charge.
63S&F in replacement of ETC tube size 58mmx2100 mm solar water collector complete all as specified as diredted by Engr-in -charge.
64S&F in replacement of ETC coupller flange set complete all as specified as diredted by Engr-in -charge.
65Rotational moulded polyethylene water storage tanks, 250 capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, including MS stand of suitable size as per recommendations of OEM of solar water heater, including two coats of anticorrosive paint over a coat of anticorrosive primer all as specified and directed.
66S& f in replacement of Mild steel framed/sheet work for tanks/panel/pump cage supported structure/ ladder and similar works conforming to Fe-290 Gde-E-165 including welding/cutting of steel including painting of two coats of synthetic enemal paint over one coat of primer paint (incl prepration of surface) complete all as specified and directed. Make: Capital/KVS/Rana
67M&L for fixing glass woolinsulation for Hot water pipe all as spfd and directed.
68S&F in replacement of air eliminator as per sample all as spfd and directed.
69M & L for hot lagging and wrapping on GI / PP-R pipe used in internal plumping work all around with bonded mineral wool performed snap on pipe section of density 48 Kg / cum conforming to IS 9842 and covered with required size of glass wool and aluminium cladding of required size for up to 20 mm bore pipe all as specified and directed.
70S&F heating element 1500/2000 watt capacity suitable for solar water heaterpush / screw type as per sample with "O" ring including making electrical connection complete all as directed.
71Repaire in replacement ofTrolley mounted self priming suction pump of 5 HP capacity with rope and starter, automatic vacuum head in stainless steel material of suitable size ,vacuum hose pipe and other connecting items complete all as specified as directed .
72Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper conductor of size 2.5 sqmm 3 core served with an inner sheathing of PVC tape armoured and overall PVC sheathed claped with 20mm pvc conduit on wall roof all as specified as directed.
73Maintenance of station swimming pool including brushingthe inside the entire pool having bottom area 400 Sqm, side wall having an area 300 Sqm, 100 meter long scum channel and having 250000 gallons entire capacity of water. Filter capacity of the pool is 150 Cum/Hour with pressure type pumps of capacity 5 HP and having chlorine plantto maintain2 PPM of chlorine in the pool water and PH level between 7 to 8 all over complete all as specified and as directed including the followings:- (i)Suction sweeping the bottom of the entire pool two time in a day by a trained operatorby using suction sweeping pump set connected with 40 mm size flexible rubber hose and tied with 12 mm nylon rope to the handles on either side for moving the sweeper in all direction for removing sediment. (ii)Removing all floating particles by usingnet in a regular interval of one hours. (iii) Feeding of chemicals in requiredproportion on Sunday/Monday as per requirement of swimming pool.(9X30)
74Supply only high density synthetic float ball of size 6" (150 mm)with double hook for suction sweeper al as specified.
75Supply only flexible hose piperibbed type high density of 40 mm size.
76S& F nylon brushwith superior quality of size as sample made out of water resistant wooden block with thickly insert nylon strings for using sweeping.
77S& F nylon rope 12 mm for the suction sweeper.
78S& Faluminimum alloy telescopic rod , top dia 30mm and bottom dia 28 mm with detachable superior quality brush ISI markedof size 6 mtr expanded upto 12 Mtr for brushing the entire area of swimming pool.
79Supply and fixing in replacement High pressure guage circular dial up to 5 Kg/Sq.cm confirming to ISMake-Aqua Services (Make:- H-Guru/Jackson )
80Supply only Ortho- Toliding solution for testing of disolved chlorine in water.
81Supply and fixing in replacement superior quality detachable type telescopic brush suitable for telescopic rod of 30mm dia(bottom 28mm dia) .
82Supply and fixing in replacement leaf net withaluminimum alloy telescopic rod , top dia 30mm and bottom dia 28 mm with detachable (of size 6 mtr expanded upto 12 Mtr)for removing floating particles from both swimming pool surface every day in the morning and evening time all as diredcted by the Engr-in-charge .
83Supply onlychlorine testing kit comprising of samples of chlorine contents in seald tube from 0.1 to 2.0 PPM and othotodoline solution , testing tube complete all as specified and as directed.
84S & F of Electric cable heavy duty for submersible pump set, flat 2.5 Sqmm 3 core multi stranded copper conductor PVC sheathed cable all as specified and directed.
85M & L for replacement of existing unserviceable LT panel, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron of size 50x50x6mm frame embeded/fixed in RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating aluminium bus bar 400 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB of make AE/Legrand/L&T, MCB DP 32 Amp-2, suitable for and including one incoming MCCB 250 Amps 4 pole 35/36 ka, Two Nos 160 Amps 4 pole 25 ka, two Nos 63 Amps 16 ka as outgoing,Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC workcomplete all as required at site or directed.
86S&F of high rate pressure sand filters bobbin wound fibre glass reinforced laminated filter of 1200 mm with UV resistant surface finish, reliable to operate under prolong sunlight for years, designed for easy inspection of quartz filter media with a six position, 50 mm multiport valve and ABS lateral with quartz filter media complete with all required materials incl dismantling of old, all materials as required at site, fixing arrangements and testing on completion all as specified and directed. Mkae : HIBIRD or Equivelent.
87Supply installation, commissioning & testing (in replacement ) of LT Panel, 415 volts, TPN AC, 50Hz wall / floor mounted indoor type cubical made out of2mm thick CRCA sheet weather, dust & vermin proof with rubber gasket with high class powder coating internally & externally fixing in position by provision of nut and bolts & addition/alteration required for fixing existing cables and connecting the all incoming/outgoing cables by suitable size of aluminium lugs stands nuts, bolts & washers including to accommodate properly following control switches:- (a) Aluminium bus bar TPN 200 Amps ratingmade of high conductivity aluminium strip of suitable length with sleeves.- 01 Set (b) Changover switch 200 Amp,4 pole,open excution, front handle operated type - 01 No (c) fully automatic star delta starter, suitable for 35 HP submersible motor, 3 phase 440 volt complete. Make- L&T cat part No-MU-G 40 or equivalent to SEIMENS / BCH (d) MCCB TP with neutral link200 Amps, 35 CA , 415 volts, AC– 02 No (For incoming) (e) MCCB TP with neutral link100 Amps, 25 CA , 415 volts, AC– 01 No (For out going) (f) MCB TPN 32 Amps, 10 KA – 04 Nos (For out going) (Make- L&T/Legrand/Siemence) (g) MCB SPN 16 Amps, 10 KA – 02 Nos (For out going) (Make-L&T/Legrand/Siemence) (h) Ammeter Digital and programable type three phase 96 mm x 96 mm size with inbuilt selector switch with necessary CTs– 01 No, Make- Schnider/Conzerv/L&T (i) Voltmeter Digital and programable type three phase 96 mm x 96 mm size with inbuilt selector switch– 01 No, Make- Schnider/Conzerv/L&T (j) Indicator lamp LED RYB phases in different colours – 01 Set
88M&L for earthing complete withGI plate electrodes 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G Istrip 32x6 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering and 40 mm dia light grade for protection of earth strip upto 7.5 mtrs, charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail