Tender For Maintenance Of External Water Supply Installations, Electrical Pumps/ Motor, Gi/Ci Pipe Lines, Valves And Other Allied Works And Mechanical Cleaning And Disinfection Of Rcc Water Tanks, Ug Sumps Including Over Head Tanks And Certain Allied, mandapam-Tamil Nadu

Military Engineer Services-MES has published Tender For Maintenance Of External Water Supply Installations, Electrical Pumps/ Motor, Gi/Ci Pipe Lines, Valves And Other Allied Works And Mechanical Cleaning And Disinfection Of Rcc Water Tanks, Ug Sumps Including Over Head Tanks And Certain Allied. Submission Date for this Tender is 10-02-2024. Supply of Motor Tenders in mandapam Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

41802077
Corrigendum : Tender For Maintenance Of External Water Supply Installations, Electrical Pumps/ Motor, Gi/Ci Pipe Lines, Valves And Other Allied Works And Mechanical Cleaning And Disinfection Of Rcc Water Tanks, Ug Sumps Including Over Head Tanks And Certain Allied
Open Tender
Indian
Tamil Nadu
mandapam
10-02-2024

Tender Details

Maintenance Of External Water Supply Installations, Electrical Pumps / Motor, Gi / Ci Pipe Lines, Valves And Other Allied Works And Mechanical Cleaning And Disinfection Of Rcc Water Tanks, Ug Sumps Including Over Head Tanks And Certain Allied Works At

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 19.97 Lakhs /-

BOQ Items

Name of Work: Maintenance of external water supply installations, Electrical pumps/ motor, GI/CI pipe lines, valves and other allied works and mechanical cleaning and disinfection of RCC water Tanks, UG Sumps including Over head tanks and certain allied works atAGE Mandapam and,Maint/Repair/Repalcement of External Electrification,HT/LT Panel, VCB/OCB, Transformer, HT/LT UG Cable and other allied works at AGE B/R Mandapam and Comprensive Maint and Carrying out Repair / Replacement of DG sets and certain other electric work at various locations under GE (I) (CG) Chennai
Sl. No. Item Description
1Supply and fix 25 mm dia medium gradegalvanisedsteel water tubes with screwed joints together with andincluding allGI fittings such as bends belows tee, unions, sockets short piece connection, backnuts, caps plugs, union coupling, flanges, socket etc laid in trenchescomplete all as specified and as directed. Note:Make of GI Pipe: Tata/Jindal/Prakash Surya
2All as per item No. 01here in before but for 40 mm bore pipe
3All as per item No. 01here in before but for 80 mm bore pipe
4Excavation in trenches not exceeding 1.5 m wideand not exceeding 1.5 m in depth for foundationf for laying pipes etc and getting out in soft/Loose soil complete all as specified and as directed.
5Returning,filling in trenches including spreading,levelling ,watering and well ramming in layers not exc 25 cm in soilcomplete all as specified and as directed.
6Removing excavated soil n exc 50 m and depositing where directed at a level n exc.1.5 m above the starting pointcomplete all as specified and as directed.
7Supply and fixGun metal globe or gate valve of following size with iron wheel head ,screwed both ends for iron pipewith neceesary fixing arragenements and including removing old one and taken as creditcomplete all as specified and as directed . Note:Make : Leader/Zoloto/Kirloskar
820 mm bore dia
925 mm bore dia
1040 mm bore dia
1150 mm bore dia
12Supply and replacement of CI Sluice valve with steel spindle bronze gate & seatling rings 80 mm dia bore both sides flanged& drilled ISI marked including suitable rubber gasket joints with bolts & nuts complete including removing old one and taken as creditcomplete all as specified and as directed . Note:Make : Leader/Zoloto/Kirloskar
13Supply and replacement of CI Sluice valve with steel spindle bronze gate & seatling rings 100 mm dia bore both sides flanged& drilled ISI marked including suitable rubber gasket joints with bolts & nuts complete including removing old one and taken as creditcomplete all as specified and as directed . Note:Make : Leader/Zolot o/Kirloskar
14Supply and fix CS air vent valve with singles air outlets, confirming to IS 14845 of size 40 mm dia bore and fixing up in PPR water supply mains of size 40mm dia complete all as specified and as directed.
15Supply and fix Non return valve 100 mm including removing old unserviceable taken as credit complete all as specified and as directed.
16Supply and fix CI foot valve of of100mm dia includingold unserviceable taken as credit complete all as specified and as directed . Note:Make : Leader/Zoloto./Kirloskar
17Supply and fix Brass Foot valve of 80mm dia including old unserviceable taken as creditcomplete all as specified and as directed . Note:Make : Leader/Zoloto/Kirloskar
18Supply and fix Brass Foot valve of50mm dia including old unserviceable taken as creditcomplete all as specified and as directed . Note:Make : Leader/Zoloto/Kirloskar
19Supply and fix Brass ball valve of 25 mm dia high pressure with epoxy coated aluminium rod andhigh density plastic ball screwed with polythene float and fly nut complete screwed and for iron pipe and fixed including removing old one and taken as creditcomplete all as specified and as directed . Note:Make : Prayag/Leader/Zoloto/Kirloskar
20Material and labour for dismantle the pump motor and clena all parts and preparation old painted surface of pump motor coupling guard MS common caseand painting withtwo coats of synthetic elanmel paint of approved of quality and shadeof Pump set capacities 01,02,03,05 and 7.50 HPcomplete all as specified and as directed . Note: Shade of paint for Pump set : Smoke grey colourand Coupling guard and grill post office red colour
21Material and labour for taking down carefully electric motor of followiing capacity 3 phase 415V,50Hz AC from foundation/coupling, opening the motor , cutting and removing the burnt winding, cleaning the stator and motor with cleaning agent,, Rewinding the mortar with appropiate gauge of super enameled copper wire of apporved make, insulatingwinding the same class of insulation, replacement of worn out parts as requried supply and replacement of base foundation nuts and bolts and re installing the motor and connecting to pump,testing themotor for statisfactory performanceincluding removing old copper wire and taken as creditcomplete all as specified and as directed .
2205 HP
2303/02 HP
247.5 HP
25Supply and fix in repairDOL starter 7.5/5.0 HP Make: L&T/SIEMENS
26Supply and fix in repair DOL starter 3/5 HP Make: L&T/SIEMENS
27Supply and fix in repair Single phase preventor Make:L&T/SIEMENS
28Material andLabour for 3-layer PP-R Polypropylene random copolymer) pipes of outer dia of pipe as mentioned below for the following sizes of SDR 7.4 &PN 16 UV stablized and antimicrobialfusion welded having thermal stability for hot andcold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete fixed in walls/ceiling/in floorsetc including removing old GI Pipe and taken as creditcomplete all as specified and as directed . Make- SFMC/Vectus
2920 mm outer dia
3025 mm outer dia
3140 mm outer dia
32Material and Labour for making connection ofPP R distrbution branch with PP R main ofouter dia 20 mm to 40 mmby providing and fixing tee including cutting and making fusion joint etc complete all as specified and as directed .
33Supply and fix PP R Gate valves (brass insert) as per requirement of site for the following outre dia of pipes :Make- SFMC/Vectus
3420 mm outer dia
3525 mm outer dia
36Cleaning of RCC closed semi under ground water sump of following capacitiesby decanning/pumping out Complete water, taking water out and remove complete Mud/Dirt/Slit/Sand, sludge from inside and depositing at a distance not exceeding50 meter away from the sump and Cleaning the bottom floor and inside wall, using scrubber/brush and Washing of inner surfacce using lime and bleaching powder and removing the same until clean surface is obtained including applyingone coat of white wash and cutting of bushes,plants etc cleaning of surrounding area upto 5.0 meter from outer wall of sump alroundand applying black synthetic enamel painting single coat on metal surface of ladder , man hole covers etc Writing the Capacity/Date of cleaning with Black and whitepaint, replacing the MS Wire mesh on air vent pipe with proper clamps , MS nut bolts complete all as specified and as directed.
3750000Litre UG sump at ICGS Manadapam
3810000Litre UG sump at ICGS Manadapam
39250000Litre UG sump at ICGS Manadapam
4020000Litre UG sump at South Manadapam
41200000Litre UG sump at CGRA Manadapam
42100000Litre UG sump at ICGS Manadapam
43Cleaning of following open shallow wellsby bailing out of water from the well by suitable HP pump set, removing the silt/mud/sand etc from the floor of wells and depositing not exceeding 50 metre, cleaning the inside vertical surface of the wells with wire brushes including removing the large growth of vegetation and removing the large floating foreign matters on the water completely including applyingone coat of white wash on the existing plastered surfaces completeall as specified and as directed .NOTE: The work shall be executed without anydelay to avoid water supply interruption in station
44Raw water well No: 1 at ICGS Mandapam
45Drinking water well at ICGS Mandapam
46Raw water well No: 2 at ICGS Mandapam
47Raw water well No: 1 at CGRA Mandapam
48Raw water well No: 2 at CGRA Mandapam
49Supply only O Tolidine regent solution in 500 ml bottle
50Supply only Calcium Hypo Chlorite Granuals (Dry Chlorine) in container of 45kg with ISI marked complete. MAKE: Puri chloror
51Service/Repair/Maintenance of sodium Hypo Chloride electronic automatic Dosing pump of 100Litres Capacity with replacing minor spares requried for the smooth plant running completeall as specified and as directed
52Supply only water ph level/conductivity/TDS tester with all kit MAKE: Hanna,, Model NO. Hi98129/HM DIGITAL
53M & L for testing of Water including taking sample of water in a new empty bottle and taking sample to Ramnathapuram test laboratory and sub,itting of report after testing complete all as specified and directed
54Supply, lay , spread in trenches, river sandincluding cleaning,spreading, levelling, punning for laying /cushioning of cablecomplete all as specified and as directed. Note:Punning thickness shall be measured and paid.
55Supply, lay in trenches burnt Bricks, old size, Sub class "B" for cable protection complete all as specified and as directed.
56Removing the old unserviceable LT UG cable including lugs and glands and taken as credit including supply and Layin trenches/poles/wall etc LT UG Cable XLPE insulated sheathed with multistranded aluminium conductor armoured with galvanised steelwire /taps 1100 volts grade conforming to IS specifications and of following sizes:-Make:Gloster/Polycab/Nicco
57LT UG Cable of size 4.0 Core 10 sqmm.
58LT UG Cable of size 4.0 Core 25 sqmm..
59LT UG Cable of size 3.5 Core 35 sqmm
60LT UG Cable of size 3,5 Core 70 sqmm
61LT UG Cable of size 3.5 Core 120 sqmm
62LT UG Cable of size 3.5 Core 185 sqmm
63LT UG Cable of size 3.5 Core 240 sqmm
64Taking outfrom trenches/poles/wall etc LTXLPE UG Cable /PVC Sheathed aluminium conductor armouredduring emegency break down times, attending and rectifying break down immediately and relaying after fault rectification duly tested in trenches/Poles/Wallof HT/LT UG Cable size of any size complete all as specified and as directed. Note:(1) Attending break down immediately, rectifying the cable fault, testingetc are inclusive of the rate quoted under this item. (2) Earth Work and excavation , Jointing Kit will be measured and paid separatly under relevent Items.
65Material and labour for cutting the existing bituminous road / cement concrete surface 150 mm thick to the required width and depth for laying pipe lines and making good the disturbed areato match with the existingsurface complete all as specified and as directed.
66Supply and fix Straight through joints (epoxy) for underground cable including joint kits and labour complete for making joints suitable for LT PVC sheathed / armoured heavy duty cables with aluminium conductor of following sizes :-
67LT UG cable of size 4 core up to 16 sq mm, Make Denson/M seal/siemens
68LT UG cableof size 3.5 core 25 to 50 sq mm, Make Denson/M seal /siemens
69LT UG cableof size 3.5 core 70 to 150 sq mm, Make Denson/M seal/siemens
70LT UG cableof size 3.5 core185 to 300 sq mm, Make Denson/M seal /siemens
71Supply and lay 50 mm dia steel water tubing galvanised medium grade including all fittings such as bends belows tee, unions, sockets etc laid in trenches for drawing cables under road/drain crossing etc complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
72Supply and lay 80 mm dia steel water tubing galvanised medium grade including all fittings such as bends belows tee, unions, sockets etc laid in trenches for drawing cables under road/drain crossing etc complete all as specified and as directed. Make- TATA/Jindal/Zenith with ISI marked.
73Supply and Replacement of MCCB 4 POLE with breaking capacity 35 KA 415 volts Adjustable thermal & adjustable magnetic setting directly fixed to board/panel /walls complete all as specified and directed of following capacitiesMake: Siemen/Schneider/ABB
74250 Amps
75200 Amps
76160 Amps
77Supply and Replacement of MCCB 3 POLE 415 voltsAdjustable type directly fixing to board/panel /walls all as specified and directed of following capacitiesMake: Siemen/Schneider/ABB
78125 Amps with breaking capacity 25 KA
79100 Amps with breaking capacity 25 KA
80Supply and Replacement of MCB TPN 415 volts C Curve directly fixed to board/panel /wallscompleteall as specified and as directed of following capacitiesMake: Siemen/Schneider/ABB
81100 Amps
8263 Amps
8332/40 Amps
84Supply and Replacement of Following capacitorsin Power Factor correction panel:
855 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
863 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
871 Kvar Capacitor Make:Epcos/Crompton Greaves/L&T
8810 Kvar Capacitor Make: Epcos/Crompton Greaves/L&T
89Supply and Replacement of Change Over Switch of the following Amps : Make:ABB/L&T/GE
90400 A
91100 A
9263 A
93Supply and Replacement of Current Tranformerof the following Amps Make;Alstom/Kappa/AE
94800/5 Amps
95400/5 Amps
96300/5 Amps
97Supply and fix Aluminium Cable lugs suitable for cable of following sizes
983.5 Core 120 to 185 sq mm
993.5 Core 50 to 90sq mm
1003.5 Core 16 to 35 sq mm
101Supply only Transformer oil
102Supply and fixBreather for transfomer up to 500 KVA
103Supply and fix Polymer TypeInsulators for 2 pole structure(ISI Marked) Note: Make:
104M & L for draining out of transformer oil complete & dismantling of 500KVA transformer complete for replacement of gasket all around and assembling of all the dismantled parts with new nuts and bolts etc, refilling of filtered oil including filtration of oil , checking of HT and LT connections including testing with meggercomplete all as specified and as directed by Engg-in-Charge. Note: Rate includes filtration of existing transformer oil, topping up of extra tranformer oil will be paid separately
105M & L for draining out of transformer oil complete & dismantling of 250KVA mobile transformer complete for replacement of gasket all around and assembling of all the dismantled parts with new nuts and bolts etc, refilling of filtered oil including filtration of oil , checking of HT and LT connections including testing with meggercomplete all as specified and as directed by Engg-in-Charge. Note: Rate includes filtration of existing transformer oil, topping up of extra tranformer oil will be paid separately
106Servicing of VCB and changing of unserviceable voltmeter and ammeter
107Servicing of ACB and changing of unserviceable voltmeter and ammeter
108Servicing of 75 KVA Stabilizer at ICGS and changing of unserviceable voltmeter and ammeter
109Supply and replace Temparature sensing meter for 500KVA transforemer complete all as specified and directed
110Supply and replace Transformer oil level meter for 250KVA transforemer complete all as specified and directed
111M & L for painting of 2 pole steel structure at ICGS mandapam including scrucbbing of 2 pole structure complete all as specified and as directed
112M & L for painting of 2 pole steel structure at CGRA mandapamincluding scrucbbing of 2 pole structure complete all as specified and as directed
113Supply and replace earth fault relay complete all as specified and directed
114Repair and welding work the existing panel board door and providedhinges for door if necessary and lock arrangement with provision of pad lock with keys, making good the elctric connection, wirings and cleaning the welding surfaces by rubbing and polishing with one coat of synthetic enamel paint all is specified and directed.
115Supply and replace ACSR conductor for HT between the 2 pole structure and transformer 500KVA at ICGS Mandapam, including proper hose for insulationcomplete all as specified and as directed
116Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as requiredof size 2mm dia galvanised iron or steel wire complete and all as specifed and as directed .
117Material and labourfor Earthing with Galvanised steel earth plate electrode of size 600 mm x 600 mm x 6.0mm thick buried directly in ground vertically ( not less than 2.25 metre deep below ground level) with top edge of the earth plate not less than 1.5 metres belownormal ground level , earth plate surronded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised strip32x6 mm as earthing lead(upto the body of existing panel) by means of bolts, nuts, check nuts and washers made up of galvanised ironand thimbles and protected by medium 40mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel,wire mesh,RCC pit cover and PCC chamber pit with PCC(1:3:6) type C-2 using 40mm graded stone aggregate,including excavation and earth work in any type of soil,returning,filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown inElectric Plate No 3 of SSR 2009(Part-I)complete all as specified and as directed.
118Supply and fix electrical insulating mate HT 22 KV grade of size 2mx1mx3mm thick confirms to IS: 15652:2006 including taking down u/s rubber mate and taken as credit complete all as specified
119Supply only Digital AC/DC clamp meter with standard measuring capacities AC/DC Voltage/current. Resistance compelete. Make Meco Model: 1080/IMP/AE
120Material & Labour for Cross arms,Bracing,Supports,clamps and back plates fabricatedof mild steel as required/ directed to the shape required for fixing to steel tubular pole/pole structures or required at any location of flood street light distribution system fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation andapplying two coats of synthetic enamel paint over a coat of oxide primer complete all as directed.
121Material & Labour for replacement of Industrail Junction box at South Hover port with mcb TPN controlouter body made of CRCA sheet 2.0mm thichness complete same as existing junction box including hinged doors for opening and closing, rubber washers for water proofing complete and painting with 2 coats enamel paint after painting with primerfor anti corrosion size as indicated complete all as directed
122Material & Labour for replacement of Meter box at ICGS 2 pole structure with dimentions (0.7m x 0.7m x 1.0m) made of CRCA sheet 2.0mm thichness complete with 2 partitions of top and bottom, transparent glass cutting on top portion for visibility of meter readings inside the box complete same as existing meter box including hinged doors for opening and closing, rubber washers for water proofing complete including taking down of old meter box and replacing all nuts, bolts, washers, welding, bending cold or hot, drilling holes & fixing with bolts to the 2 pole structure in any shape or size as indicated or directed including preparation andapplaying RAL coat paint for anti corrosion complete all as directed.
123Servicing/Comprehesive maintenace of DG set of 250 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, beltsetc,and attending breakdown as and when requried completeall as specified and as directed. (NOTE: Spare Parts and consumablesshall be measured andpaid seperately)
124Servicing/Comprehesive maintenace of DG set of 50 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, beltsetc,and attending breakdown as and when requried completeall as specified and as directed. (NOTE: Spare Parts and consumablesshall be measured andpaid seperately)
125Servicing/Comprehesive maintenace of DG set of 15 KVA to 40 KVA capacity ,kirloskar Make Including servicing of all parts as per maintenace manual, replacement of filters, coolant, engine oil, beltsetc,and attending breakdown as and when requried completeall as specified and as directed. (NOTE: Spare Parts and consumablesshall be measured andpaid seperately)
126Supply of fuel filters, Lub oil filters for 250 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
127Supply of fuel filters, Lub oil filters for 40KVA/50 KVA DG Set Make:Greaves power/Mahindra/Ashok leyland
128Supply only High grade Engine oil suitable for DG sets upto 200 KVA .Make :Servo/Greaves power/Mahindra
129Supply only coolant oil heavy duty suitable for DG setcompleteall as specified and as directed.Make:Servo/Greaves power/Mahindra
130Supply only distilled water for battery.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail