Tender For Repair/Replacement And Servicing Parts Of Ac Plants And Allied Works At South Side Of Runway At Af Station Jodhpur, jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Repair/Replacement And Servicing Parts Of Ac Plants And Allied Works At South Side Of Runway At Af Station Jodhpur. Submission Date for this Tender is 19-02-2024. AMC of Air Condition Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

41799907
Corrigendum : Tender For Repair/Replacement And Servicing Parts Of Ac Plants And Allied Works At South Side Of Runway At Af Station Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
19-02-2024

Tender Details

Repair/Replacement And Servicing Parts Of Ac Plants And Allied Works At South Side Of Runway At Af Station Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

BOQ Items

Name of Work:Commander Works Engineers, Air Force, Jodhpur
Sl. No. Item Description
1Material & Labour for finding out the leakage with the pressure test of water chiller scroll type capacityup to11 TR,identifing gas and oil leakage and removing the same andLeak repairing by brazing/flaring andflushing the sysytem by nitrogen gasandpressure testing for leakage and rectifiedand after rectification vacumacation, pressuretesting,andgas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge. NOTE :- Gas charging requiredshall be measured and paidseparatelyas supply only.
2Ditto all as per Ser item No 1.00 above but capacityup to11 TR to 25 TR,
3Ditto all as per Ser item No1.00 above but capacityup to 25 TR to 50 TR,
4M&L for taking out unserviceable sealed unit (compressor) as existing and replacing the same with new packaged type sealed unit (compressor)12.5 ton capacity ,model-SZ185S4RC , three phase, 415 volt of modelsDanfoss make including necessary modification of the foundation as required to suit the compressor, flushing the sysytem by nitrogen gasandpressure testing for leakage and rectified (bybrazing) and after rectification vacumacation, pressuretesting,andgas charging R-407c for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-ChargeNOTE :- Gas charging requiredshall be measured and paidseparatelyas supply only.
5M&L for charging of refrigerant R-407c Gas. (Make:- Mafron/ Feron/floron/du point) complete all as specified and directed
6M&L for charging of refrigerant R-134A Gas. (Make:- Mafron/ Feron/floron/du point) complete all as specified and directed
7M&L for replacement ofthermostatic expansion valve suitable for water cooled scroll chiller unit cap 25/37/50 TR all as per sample, including brazing at both ends all as required and directed.
8M & L for replacement of HP/LPswitch suitable for scroll compressor cap up to 12.5 TR all as per specified and directed.
9M&L for replacement of Drier filter suitable for Package type AC Plant size 5/8" Make: Catch All Model : C-165
10M&L for replacement of chilled water sensorcomplete all as specified and directed
11Supply and fix in replacement of microprocessor based computer controlled PLC make Blue star capacity 5.5TR PACKAGE TYPE unit make softhard for water cooled scroll chiller unit .
12Supply and fix in replacement of microprocessor based computer controlled PLC make Blue star capacity 11TR PACKAGE TYPE unit make softhard for water cooled scroll chiller unit .
13M&L for repairs ofcondenser/chiller pumps from 2HPUpto 7.5 HP including dismantling ofPumpof following capacity and segregating to its parts for repairs and maintenance, replacement onlyofshaft bearing, impeller key, shaft sleeve, impeller and grinding / polishing, bend removing etc complete including painting by two coats of synthetic enamel paint reassembling of pump after completion of work & testing complete all as per direction and satisfaction of Engineer in charge. Note:-Supply only of bearing and sleeve, impellerwill be measured and paid under relevent item of work.
14Supply and fix in replacementof spare parts of pumps sets (To be incorporated under respective item above ) :- (a) Shaft bearing as per existing specifications.
15(b) Shaft sleeveas per existing specifications.
16(c) Impellerwith keyas per existing specifications.
17(d) Mechanical Couplings as per existing specifications.
18(e) rubber type coupling as per existing specifications.
19M & L for repairing /Disconnecting the electrical and mechanical connection of burnt electrical motors from the site / location, transporting to and from to work shop.Rewinding of electrical motors/ pump motorsby dismantling and removing the burnt cut copper winding wire cleaning the slots of stator with petrol and brushes winding polyster based super enamelledcopper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles complete stator / roter after rewinding reassembling all parts including reinstalling connection to original position and testing on full load all as directed by Engineer in charge for different capacity of motor as per following :- (a) 1 to 2 HP
20(b) 3 to 5 HP
21(c) 7.5to 12.5 HP
22M&L for replacement of Thermostat Honey well 0-30 degree C
23M&L for disconnecting electrical connections motor located at the top of cooling tower,keep cables at safe custody for reconnection and dismantling and taking out fan blade assembly along with motor mounted on base frame at the top of cooling tower after cutting/dismentalingall nuts, bolts and fixtures from the mounting frame and removing wholeassembly including motor and base frame from the top of cooling tower with the help of T&P for servicing of cooling tower suitable for 100-120 TR capcity including following complete:- (i) Cleaning /scrapping of inner& outer surface of FRP basin, repair of damaged portion if any incuding FRP lining of all surfaces joints to avoid leakage including replacement of all nuts and bolts joining all parts of Basin complete. (ii) servicing coolingtower plant through cleaning re-agent complete pipe line, including servicing of cooling tower motor and fan and make the necessary alignment with motor. (iii) replacement of bearing if any of suitable cap if any after necessory work including gressing and replacement of nut bolts and preventing leakage if any by means of suitable adetives etc all as directed and specified. (iv)taking out PVC fills blocks, cleaning and refixing as per existing location and channel direction if pvc fills vintage then replace with new one measure seprately . (v)servicing of spray header and sprinkler assy complete. (vi) repair of water strainer complete.
24Ditto all as per Ser item No 23.00 above but cooling tower suitable for 25- 60 TR capcity
25supply and fix in replacement of Cooling Tower Sprinkler Assembly such as Sprinkler, Sprinkler Pipe, Elimentor, Tension bar and Turn buckle for Cooling Tower capacity 160/120/100 TR as existing on site make :-MIHIR or equivalent suitable as per existing and ali as perdirected by engg in charg
26supply and fix in replacement of Cooling Tower Sprinkler Assembly such as Sprinkler, Sprinkler Pipe, Elimentor, Tension bar and Turn buckle for Cooling Tower capacity 50 TR/30/22/37.5/12.5TR TRnosal type /sprinklar type as per existing make :-Delta or equivalent suitable as per existing and ali as perdirected by engg in charg
27S&F in replacement of of PN 1.6 butterfly valves size 125 mmduly insulated with companion flanges,nuts,bolts,gaskets etc.as specified . butterfly valves with cast iron body, seat of black nitrile rubber ,nylon coated S.G.iron disc,epoxy powder coated shaft AISI 410 etc.complete all as specified and directed. Make Audco/castel/kirloskar
28Ditto all as per Ser item No 27.00 above but size 100mm.
29Ditto all as per Ser item No 27.00 above but size 80mm.
30Ditto all as per Ser item No 27.00 above but size 65mm.
31Material and labour for replacement of rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) of cap 2000 ltrs hoisted and fixed in position all as specified in SSR Part-I
32M & L for Descaling the condenser by descaling compound / hydrochloric acid by soaking method,disconnecting condensor from the system by taking out nuts, bolts, studs, valves and MS/GI pipe line from both side cover, cleaning each tube with nylon brush,flushing with alkaline solution,connecting back both side cover including replacingleather gasket 4 mm thick for following capacities of condensers suitable for AC Plant installed as indicated below complete all as specified and directed and all as per manufacturers instruction and to the entire satisfaction of Engineer-in-charge. (a) chiller unit cap 80 TR
33b)Ditto all as per Ser item No 32.00 above but chiller unit cap 65 TR
34b)Ditto all as per Ser item No 32.00 above but chiller unit cap 50 TR
35d)Ditto all as per Ser item No 32.00 above but chiller unit cap 25 TR
36e)Ditto all as per Ser item No 32.00 above but chiller unit cap upto 12.5 TR
37S&F in replacement of air filter for AHU, Filter section consists of50 mm thick washable HDPE 90% down 10 micron Pre-Filters, AHU prefilter having HDPE media with aluminium / GI frame & filter as per the existing size of600mmX600mmX50/40 mm mm complete all as specified and directed.(Make :- Supreme/Athlete or equivalent
38M&L for replacement of" V Belt ofA & B Series any sizesfor AHU "s as per site requiement complete all as specified and directed
39Supply and fix in replacement of water presuure gauge 0-7 kg / cm2 including Female Stainless Steel Gauge Fittings INCLUDING ball valve 5/8", type MakeFebig or equivant suitable makes as per appx "B" complete all as specified and directed
40S&F in replacement ofthermometerto condenser/chiller, inlet or outlet water pipes including addition alteration to pipe line for fixing thermometer Range 0-100 degreeF / degree centigrade complete all as specified and directed
41M&L for replacement of25 mm dia. Auto Air Purge valve for chilled water piping complete all as specified anddirected.
42M&L for replacement ofstop valve 15 mm dia complete all as specified anddirected..
43S&F in repairs worn out HRC fuses (Cylindrical / DIN type / Bolted)conforming IS 13703 Part - II with high breaking capacity suitable for existing holders all as specified and as directed forthe following capacities :- (a)10 Amps to100 Amps
44S&F in repairs worn outfuses (Cylindrical / DIN type / Bolted)conforming IS 13703 Part - II with high breaking capacity suitable for existing holders all as specified and as directed forthe following capacities :- (a)2Amps to 10 Amps
45Supply and fix in replacement of PVC insulated 4 Core copper Cable of size 6 Sqmm complete all as specified and directed
46M&L for replacement ofIndicating Light, 240V AC, LED Type Red, Yellow, Blue complete all as specified and directed
47M&L for replacement of ON/OFF Push Button complete all as specified and directed
48M&L for replacement of repair of thermal Relay MNX 32A 3-6 Amp complete all as specified and directed
49M&L for replacement of thermal Relay MNX 32A 6-10 Amp complete all as specified and directed
50M&L for replacement of thermal Relay MNX 32A 10-16 Amp complete all as specified and directed
51M&L for replacement of MNX -A1 size contactor complete all as specified and directed
52M&L for replacement of MNX -A2 size contactor complete all as specified and directed
53M&L for replacement of MNX 32A contactor with NO/NC switchcomplete all as specified and directed
54M&L for replacement of MNX 18A contactor with NO/NC switchcomplete all as specified and directed
55M&L for replacement of MNX 12A contactor with NO/NC switchcomplete all as specified and directed
56M&L for replacement of Timer GIC star/delta complete all as specified and directed
57M&L for replacement of connector for suitable to chillerpanel complete all as specified and directed
58Supply and Fixing in replacement of MCCB 400 Amp 4Pole 36 KA thermal megnatic complete all as specified and directed
59Supply and Fixing in replacement of MCCB 250 Amp 4 Pole 36 KA thermal megnatic typecomplete all as specified and directed
60Supply and Fixing in replacement of MCCB 160 Amp 4 Pole 25 KA thermal megnatic typecomplete all as specified and directed
61Supply and Fixing in replacement of MCCB 100 Amp 4 Pole 16 KA thermal megnatictypecomplete all as specified and directed
62Supply and Fixing in replacement of MCB TP C63 Amp415 Volt complete all as specified and directed
63Supply and Fixing in replacement of MCB TP C40/32 Amp 415 Volt complete all as specified and directed
64M&L for taking out unserviceable sealed unit (compressor) scroll type for CASSETEAC 5.5 ton capacity , SINGLEphase, 415 volt of models as existing and replacing the same with new packaged type sealed unit (compressor) of Hitachi/Danfoss/daikin/copeland make including necessary modification of the foundation as required to suit the compressor, vacumacation, pressure , testing, leaking, rectification includinggas charging R-22/407/410 for achieve desire pressure and testing complete to the entire satisfaction of Engineer-in-Charge
65M&L for replacement of Al Fan blade for out door Fan motor assembly suitable for ductable AC 5.5/8.5 ton capacityMake - Hitachi/Danfoss/Tecumesh
66M&L for replacement of chilled water sensor for screw typr compressor complete all as specified and directed
67M&L for replacement ofPCB control card set complete suitable for CASSETE AC of any capacity 4.0 TRrequirement complete and testing the AC after the replacement of PCB as specified.
68M&L for taking out unserviceable heating element of dehumidifier of models as existing and replacing the same with new complete to the entire satisfaction of Engineer-in-Charge
69M &L for WATER JET servicing of CASSETE/FAN COIL UNIT type AC "s cap 1.5/2/4 TR complete indoorunit from existing location for servicing inner and outer filter complete with T&P and other accessories as directed.
70Supply and fix thermometer humidity meter clock with sensor cable Temperature and Humidity Functions: With temperature range from -10 degC to +50 degC and humidity 10 % sim 99 % RH, temperature and humidity readings show directly all as per directed
71S &F in replacement of humidistat H6000to control humidity range 15 to 80 % RH all as per specified and directed .
72Painting of AC plant complete equipments (MS pipes ,cooling tower,chiller unit,pumps and motors ) with proper color code,removal of rust and old paint ,and painting of SM /MES no of machines as per directed by engineer in charge
73Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. As directed
74Supply and fixof cooling tower PVC honey comb fillsin colums of size 600mm x 300mm x 150mm size and min wt 600 gram of capacity 15 TR to 150 TR for the following Make : Kool Drop / MIHIR / ADVANCE / HIMGIRI per existing specification and requirement.
75Supply and fix of multifunction meter voltage, ampere, power,power factor measureable accuracy class 1 for 3 phase panel including setting the parameter with CT as directed
76M&L in replacement for duct insulation highly flexible closed cell thermal insulation of 19mm thickness of elastomeric foam based on synthetic rubber laminated with 12 micron aluminium foil fencing with reinforced glass scrim and addehessive rubber coating class BS 476 as directed by engineer in charge
77M& L for repair for humidifier including cleaning of tank ,replacement of heater of 2KW ,painting of tank with corrosion less paint ,rewiring of electrical panel as directed by engineer in charge
78M&L in repair of MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 65MM with FRP insulation as directed
79M&L in repair of MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80MM with FRP insulation as directed
80Supply and fix in repair Y staineer filter as per existing size and make as directed
81Supply and fix in replacement of GI pipe mediam grade of size 25mm used in ac plant with required accessoried and labour workas directed
82Supply and fix in replacement of float valve of size 25mm used in ac plant with required accessoried and labour as directed
83M&Lfor replacement of electrical strip heater ,finned type ,capacity 2 kwconsisting of stainess steel sheathing having heatresistent chrome -nickel 80/20 element protectedunder best insulation to avoid the leakage of current and with screwed type terminal at one end, 240 volts, AC, 50Hz ,single phase completeall as specified and as directed.
84Supply,installation,testing and commissioning in repair of 3 way mixing/ divertingactuator valve of siz 65 mm dia with proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. As per specifications and makeexisting on site as directed
85Supply,installation,testing and commissioning in repair of 3 way mixing/ diverting actuator valve of size 80 mm dia with proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. As per specifications and makeexisting on site as directed
86Supply,installation,testing and commissioning in repair of 3 way mixing/ diverting actuator valve of size 100mm dia with proportional cooling only thermostats for the Air Handling Units complete with required controls wiring/installation kit etc. As per specifications and makeexisting on site as directed
87Providing and fixing in repair FRP lining of 6 mm thickness on cooling water piping near cooling towers to minimize corrosion of MS piping of 65mm diameter as directed
88Providing and fixing in repair FRP lining of 6 mm thickness on cooling water piping near cooling towers to minimize corrosion of MS piping of 80mm diameter as directed
89Providing and fixing in repair FRP lining of 6 mm thickness on cooling water piping near cooling towers to minimize corrosion of MS piping of 100mm diameter as directed