Tender For Construction Of Community Solar Water Pump Near Goutam Sarkar House At Sarkarerbari At Genduguri At Sansad Xiv Under Nayarhat Gram Panchayat Within Mathabhanga-I Dev Block Activity Id- 58538566 ( 2022-23 )
Tender Value
4.68 Lakhs
Estimated cost
Bid Submission
07 Feb 2024
0 days left
EMD
9364
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nayarhat → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Community Solar Water Pump Near Goutam Sarkar House At Sarkarerbari At Genduguri At Sansad Xiv Under Nayarhat Gram Panchayat Within Mathabhanga-I Dev Block Activity Id- 58538566 ( 2022-23 )
BOQ
| Sl. No. | Item Description |
| 1 | Earth work execution of foundation trenches or drains.In all sort of soil (including mixed soil but excluding literate or sandstone) including removing spreading or stacking the soil within a lead of 75 m as directed. The items including necessary trimming the sides of trenches leveling dressing and ramming the bottom bailing out water as a required complete. Depth of excavation not exceeding 1500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth in layer not exceeding 150mm including watering & ramming etc. Layer by layer complete ( Payment to be made on the basis of measurement of finished quantity of work) With earth obtained from excavation of foundation.a) With earth obtained from excavation of foundation |
| 3 | Single brick flat soling of picked Jhama bricks including ramming and dressing bed to proper level and filling joints with powered earth or local sand. |
| 4 | Cement Concrete with 30 mm down graded shingles excluding shuttering in ground floor(a) 1:3:6 Proportion |
| 5 | Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttring and reinforcement if any, in ground floor as per relevent IS codes.B) River Bazree |
| 6 | Reinforcement for reinforced concrete work in all sort of structure including distribution bars . stirrups, binders etc. including supply of rods initial straightening and removal of loose rust ( if necessary) cutting and requisite length. Hooking and bending to current shape. Placing in proper position and bending with 16 gauge black annealedwire at every inter section . complete as per drawing and direction. SAIL/TATA/RINL |
| 7 | Hire and labour charges for shuttering withcentering and necessary staging upto 4m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns ,lintels curved or straight including fitting fixing and striking out after completion of work (upto roof of ground floor )(f) 25 mm to 30 mm shuttering without staging in foundation |
| 8 | Neat cement Punning about 1.5mm thick wall dado window sills,floor,drain etc. |
| 9 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 50 mm dia. tube well with topenlargement of 100 mm dia. |
| 10 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (d) For depth upto 150 metre for 100 mm dia. tube well with topenlargement of 100 mm dia. |
| 11 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes 50 mm dia |
| 12 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes 100 mm dia |
| 13 | Supplying PVC strainer of approved make with adapter conforming toI.S.12818 specifications. ii) 50 mm dia |
| 14 | Supplying, fitting and fixing steel cutter piece upto 450 mm long withsockets. |
| 15 | Supply of long screw (150 mm long) of TATA make with sockets (TATAmake) and jamnut. 40 mm dia |
| 16 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer (b) 1000 litre capacity |
| 17 | Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L. |
| 18 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 19 | Supplying, fitting and fixing heavy type bell mouth reducing socket. (i) 50 mm X 100 mm |
| 20 | Supplying, fitting and fixing chech valve (vertical) G.M. tested to 21 kg per Sq.cm 50 mm |
| 21 | Supplying, fitting and fixing plug of approved make conforming to I.S.specifications.50 mm |
| 22 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approvedquality. |
| 23 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.i) For structural members of specified sections weighing less than22.5 Kg./m |
| 24 | Supplying, fitting and fixing CPVC (ChlorinatedPolyvinyl Chloride) pipes of approved make conformingto IS-15778: 2007 . with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including costof all necessary fittings as required,jointing materials inany position above ground. (Payment will be made onthe centre line measurements of total pipe line includingall specials. No separate payment will be made foraccesories, specials. (ii) CPVC Pipes Class-2,SDR-13.5 25 mm dia |
| 25 | Supplying, fitting and fixing alloy iron with brass spindle bib cock/stop cock of approved brand and make, spray painted and tested to 21 kgper sq. cm. i) 15 mm |
| 26 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. On steel or other metal sursace |
| 27 | Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc.including using of approved putty etc. on the surface, if necessary : b) On steel or other metal surface : With super gloss (hi-gloss) - Except white in shade |
| 28 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.(SAIL/TATA/RINL) |
| 29 | 125mm thick brick work with 1st class bricks in cement mortar (1:4) in ground floor |
| 30 | Supplying, fitting and fixing 1st quality ceramic tiles in walls and floors…(a) Area of each tile upto 0.09 sqm (i) Coloured decorative |
| 31 | Supplying fixing commissioning and testing Solar Voltaic Module 250 WP 40V on existing iron frame structure each 156 mm Monocrystalline sillicon Solar cell laminated between sheet of Ethyline Vinyl Acilate (EVA) and high transmissivily 3 mm tempered glass. Confirming to IEC 61215 (Revised) specification or equivalent National of International Standards. The power output of the module under STC should be minimum of 250W . The operating voltage corresponding to the powder output mentioned above mentioned above should be at least 57.0 Volts. The terminal Box IP 65 Protection level on the module should have a provition for opening or replaceing the module (Havells/TATA/Waree make) |
| 32 | Supplying fitting Fixing & Installation of Iron Removing Filter Plant Capacity 1500 LHPIR Media Filter Working -DownilowMax Flow Rate -3m3/hr Working Pressure -1-3 kg/cm2 Size- 14\" X 65\" Make Pentair (BIS Standards & Including 1 Year Warranty) |
| 33 | Supply and fixing round 2-core 4 sq-mm PVC multi core FR wire for aray connecting |
| 34 | Supply and fixing MC4 connector for panel loop |
| 35 | Earthing with 50mm (2\") dia G.I. pipe 3.64 mm thick x3 mts. Long and 1x4 SWG G.I wire (4 mts. Long) 13mm dia x 80 mm long G. pipe protection (1mtr,long) to be filed with bitumen partly under the ground level and partly under the ground level and partly above ground level driven to an average depth of 3.65 ms. Below the ground level & restoring the surface duly rammed . for soft soi |
| 36 | Connecting the all equipment to earth busbar including GI (Hot Dip)wite of size as below on wall floor……as required and making connection to equipment with bolts,nuts,washers cable lugs as required and mending good damages No. 4 SWG |
| 37 | Providing and fixing conductor made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick copper base plate including holes etc .complete as required . |
| 38 | Supply, Installation testing & lowering of 1.5 HP oil soler submersible pump motor set complete having suitable discharge as per yieled test of well.Submersible cable of 30 mtr 3-core 2.5 sq-mm cable with MDC bar chart and necessary control panel and starter asper manufacturer specification .(Kirloskar/Waree Make) |
| 39 | GST |
| 40 | LABOUR CESS |
AI Tender Summary
Tender Timeline
Jan 22, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 07, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 10, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender