Repairing, Servicing And Spare For 33Tr Voltas Make Air Cooled Chiller , Repairing And Servicing , Supply And Fixing Of Panel With Controller For Control Of T& Rh For Ahu No.1, 2, 3. Standalone Controller With Enclosure-Tm171 Make:-Schneider / Equivalent , Supply And Fixing Of Duct Mounted Temperature & Rh Sensors Make:-Honeywell / Greystone / Equivalent , Removing Of Exiting Defective Chiller Sensor .Supply And Fixing Of Chilled Water Sensor In Unit No. 1, 2, 3 Make:- Voltas , Supply And Fixing Of Relief Valve 1 / 20-450 Psi In Unit No.1, 2&3 , Removing Of Existing Defective Compressor. Supply And Fixing Of Sm185 Compressor. Pressure Testing Vacuumizing Gas Charging Testing And Commission Of The System , Removing Of Existing Defective Contactor. Supply And Fixing Of L&T Contactor In Ahu No. 1, 2, 3 , Removing Of Existing Defective Heaters. Supply And Fixing Of Strip Heater In Ahu No.1, 2 3 Including Rectification Of Control Wiring. Make: Dasspass / Escort / Equivalent , Supply And Fixing Of Digital Ammeter In Electrical Panel Make:- Ae / Equivalent , Supply And Fixing Of Voltmeter In Electrical Panel Make:- Ae / Equivalent , Dismantling Of Exiting Defective Steam Generator. Supply And Fixing Of 12 Kw Steam Generator Including Float Valve Etc. Make:- Rapid Cool / Equivalent , Dismantling Of Exiting Defective Steam Generator. Supply And Fixing Of 3 Kw / 6Kw Steam Generator Including Float Valve Etc Make:- Rapid Cool / Equivalent , Supply And Fixing Of Pressure Gauge With Fitting Make:- Hguru / Fiebig / Equivalent , Supply And Fixing Of Stem Type Thermometer With Fittings. Make:-Hguru / Fiebig / Equivalent , Supply And Fixing Of Siemens Contactor In The Chilling Unit Including Checking Of Control Wiring , Supply And Fixing Hp / Lp Switch In The Chilling Unit No.1, 2, 3 Including Fittings Make:- Indfoss / Danfoss / Equivalent , Supply And Fixing Of Catch All Drier In The Chilling Unit , Supply And Fixing Of V-Belt In Ahu No1, 2, 3 , Supply And Fixing Of Siemens Contactor In The Chilling Unit Including Checking Of Control Wiring , Removing Of Existing Expansion Tank. Supply And Fixing Of Expansion Tank Including Providing Of Structure And Fittings Etc , Supply And Fixing Of Drain Pipe Of Size 2 Inch Including Fittings , Overhauling Of 7.5 Hp Monoblock Pump Including Replacement Of Worn Out Part , Pressure Testing Of The System And Leak Rectification By Brazing. Pressure Testing Of The System For Any Leak. Flushing Of Complete System With Dry Nitrogen , Vacuumizing The Complete System. Supply And Charging Of R-22 Gas In Unit No.1, 2, 3 , Servicing Of Ahu And Cleaning Of Cooling Coil With Chemical Including Checking Of All Control And Safety Device For Smooth Operation Of Ahu , Servicing Of Units And D-Scaling Of Chillers, Cleaning Of Condenser Coil With Chemical Including Checking Of All Control And Safety Device For Smooth Operation Of Chilling Units