Power Government Departments Closing in 0 days TDR #41763342

Tender For Smp-Pampa-Refurbishment Of Guest House At Pampa And Parking Facilities (Tractor And Official Parking) Re-Tender

Issued by Government Departments · Pathanamthitta, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Feb 2024
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Smp-Pampa-Refurbishment Of Guest House At Pampa And Parking Facilities ( Tractor And Official Parking ) Re-Tender

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-Jan-2024 Notice for extension of date of submission and opening of etenders Date 01-Feb-2024

BOQ

Name of Work: SMP-Pampa-Refurbishment of Guest House at Pampa and Parking Facilities (Tractor and Official Parking) - Re-tender
Sl. No. Item Description
1APPENDIX I - Demolishing Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
2Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
3Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres
4Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of:G.S.Sheet
5Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of usefulmaterials near the site and disposal of unserviceable materials within 50 metres lead
6Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
712 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
8Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800x 800 mm
9Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
10Providing and laying Polished Granite stone flooring in required design andpatterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed withcement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing , curing and polishing etc. all complete asspecified and as directed by the Engineer-in- Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
11Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building all completeas per the architectural drawings with 18 mm thick stone slab over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid andjointed with cement slurry and pointing with white cement slurry admixed withpigment of matching shade including rubbing, curing and polishing etc. allcomplete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.
12Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622(thickness to be specified by the manufacturer), of approved make, in all colours,shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,in skirting, risers of steps and dados, over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per sqm, including pointing in white cement mixed with pigment of matchingshade complete.
13Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mmlong dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm havingapprox. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer\"s specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.
14Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete
15Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
16Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
17Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
18Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
19Providing and fixing factory made uPVC door frame, made of uPVC extruded section, of size 65 mm x 55 mm with wall thickness 2.0 mm (? 0.2mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm ( ? 0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer\"s specification and direction of Engineer-incharge.
20Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm ( ± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (± 02. mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer\"s specification and direction of Engineer -in- charge.
21Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
22Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak woodProviding and fixing panelled or panelled and glazed shutters for doors, windowsand clerestory windows fixing with butt hinges of required size with necessaryscrews, excluding panelling which will be paid for separately, all complete as perdirection of Engineer-in-charge. (Note:- Butt hinges and necessary screws shallbe paid separately)Second class teak wood35 mm thick shutters
23Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
24Providing and fixing wall mounted wash basin with VIKING 9601 RACK BOLT, :Jaquar wall mounted wash basin,(White) model no:ARS-WHT-39803
25Providing and fixing white wall mounted water closet with seat and lid, concealed flushing cistern,cover etc. with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, of good quality. JaquarWhite wall mounted water closet . Model no:VGS-WHT-81953UF,JCSWHT- 2400FS, Single Piece Slim Concealed Cistern with Floor Mounting Frame, Installation Kit and “SType” Drain Pipe Connection Set for Wall Hung WC (without Flush Control Plate)- model no:JCS-WHT- 2400FS, Control Plate Opal model no:JCP-CHR-152415
26Providing and fixing white CASCADE water closet with seat and lid, flushing cistern, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, of good quality. (Jaquar- model no:CNS-WHT-853S300SPPSM)
27Supplying and fixing body of C.P Single lever concealed mixer and Divertor for bath and shower system with divertor assembly and catridge sleeve but without exposed parts kit of good quality (Jaquar-Model no:FUS-CHR-29273UPR) including cutting and making good the walls wherever required, fitting charges all complete as per direction of Engineer In charge.
28Supplying and fixing C.P Single lever divertor exposed part kit . (suitable for item no:23 above) of good quality.( Jaquar-Model no:VGP-CHR-81079NK S/LEVER) including fitting charges all complete as per direction of Engineer In charge.
29Supplying and fixing C.P pillar cock of good quality for wash basin.(Jaquar-Model no: VGP-CHR-81001) including fitting charges all complete as per direction of Engineer In charge.
30Supplying and fixing C.P brisk health faucet with , 1.50m long SS flexible tube of good quality ( Jaquar- Model no: ZMS-CHR-027N for faucet&Model no: SHA-CHR-549 for tube) including fitting charges all complete as per direction of Engineer In charge.
31Supplying and fixing C.P shower, shower arm and flange of good quality ( Jaquar-model no- OHS-CHR- 1605 for shower&SHA-CHR-455L400 for shower arm )including fitting charges all complete as per direction of Engineer In charge.
32Supplying and fixing Hand shower including wall bracket of good quality ( Jaquar-model no- HSH-CHR- 1655 for hand shower square shape 95x95 mm &CHR-555, wall bracket for hand shower) including fitting charges all complete as per direction of Engineer In charge.
33Supplying and fixing Bathset (5 pieces) including soap dish,towel rod,towel ring,brush holder,Double coat hook etc of good quality including fitting charges all complete as per direction of Engineer In charge.
34Supplying and fixing Bath tub spout of good quality ( Jaquar- model no:SPJ-CHR-81463 )including fitting charges all complete as per direction of Engineer In charge.
35Supplying and fixing waste coupling 32 mm of good quality ( Jaquar-Model no:ALD-CHR-709 ) including fitting charges all complete as per direction of Engineer In charge.
36Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
3750 m mm thick ashlar stone flooring over 20 mm average thick base of cement mortar 1:4 (1 cement :4 course sand) with joints finished flush
38Necessary labour charges for shifting the materials
39Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes
40Supplying and fixing water heater of good quality.(Jaquar digital water heater(6 litre)-model no:METWHT- V006) including fitting charges all complete as per direction of Engineer In charge.
41Providing shingle sheet for Entrance porch .
42Supplying and providing new wooden cot single (rubco) furnitures As per the instructions from the Engineer in charge
43Supplying and providing Foam bed mattresses As per the instructions from the Engineer in charge
44Supplying and providing Rubber mats , etc some urgent needs

45Rectangular shape 1500x450 mm Mirror with Plastic moulded frame
46Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
47Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. Thisincludes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
48Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6Kgf/cm2 - Internal work - Exposed on wall
49Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
51Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
52Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
53Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
54Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mm diameter of the inner hinged round grating
55APPENDIX II - Refurbishment of Guest House at Pampa and parking facilities (Tractor and Official Parking) - Providing ElectificationDismantling and removing the existing damaged electrical installations and stacking carefully-Labour Engageda. Wireman
56b. Wireman Helper
57c. Man Mazdoor
58Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
59Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B)
60Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
61Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
62Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5 /6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
63Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
64Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) 25A SP switch with indicator
65Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant) 25A 3pin Shuttered socket
66Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant) 25A 3 pin plug top with indicator
67Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
68Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
69Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
70Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
71Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm 1X20W LED Lamp with box type fixture
72Supply,installation,testing and commssioning of 1500 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree /Osram /lumilled /Nichea
73Supply,installation,testing and commissioning of Mirror light (crompton Linea) LED batten 5W Dimesions 1 Ft
74Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
75Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
76Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm
77Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
78Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm
79Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
80Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 4 sq mm with factorymade clamp
81Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
82Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required. 4 core 16 sq mm with factory made clamp
83Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed inrecess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
84Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc.as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
85Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)
86Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
87Supply, installation, testing and commissioning of 40 A to 63 A, TPN MCB (C curve), 10 kA breaking capacity
88Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps
8963 Amps
90Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
91Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps.
92Supply, installation, testing and commissioning of 16 A-100A, 25 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
93Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
94Supplying and fixing extra conduit down rod of 10 cm length G.I.pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
95Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
96Supply and drawing bare earthing conductors of the following sizes along with wiring/cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
97Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
98Supply, installation, of 25x3mm brass bolt with hexagonal/square head, nut and washer
99Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
100Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 50x50mm Cable Management System with base and lid a. 50x50mm Cable Management System with base and lid
101b. Flat angle 90 Degree /Tee
102c. Internal angle 90 degree
103d. End cap
104e. Joint cover
105Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.a. 100 x 50 mm CMS with base and lid
106b. External angle 90 degree
107c. Flat angle 90 degree
108d. End cap
109e. Joint cover
110Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
111Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
112Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays,indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA
113Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
114Supply and providing copper earth bus in the panel board
115Supply and providing 4mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
116Supply and providing heavy duty \"A\" section neoprene gasket in the panel board U\" section rubber beeding suitable for 1.60/ 2.00 mm sheet
117Supply, installation, of Anchor bolt 12mm
118Supply, installation, and fixing of 160, HRC Fuse Base with HRC Fuse link
119Supply, installation, and fixing of 100 A, 2 Way neutral links mounted on DMC/SMC base
120Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp TP & N
121Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp TP&N
122Supply & Fixing of indication lamp in existing panel board
123Supply and fixing following Multifunction meter to read VAF 3 phase accuracy class 1 including drilling holes in cubical panel ,making connections etc.
124Supplying, installing, testing and commissioning of following capacity 63A FP Automatic change over (INSTAPRIME) with auto and manual operation EB,DG & OUT Poing incomer 63,4. FP MCB, indicator for EB,DG&Load, control MCB2A, SPP, with enclosure made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with connections, earthing etc. as required.
125Supply and Fixing of 1.5 Tr Air conditioner
1264 KVA Stablizer
127ODU Stand
128Installation charge
129Supply and fixing of Water Heater 10L

AI Tender Summary

OUR REF NO 41763342
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-02-2024
Authority
Authority Name High Power Committee
Work Description Tender For Smp-Pampa-Refurbishment Of Guest House At Pampa And Parking Facilities ( Tractor And Official Parking ) Re-Tender
Basic Detail
Tender No T-22/HPC/SMP/2023-24
Bidding Type Tender
Location
City Pathanamthitta
State Kerala
Key Dates
Publish Date 29 Jan 2024
Submission Date 01 Feb 2024
Open Date 03 Feb 2024
Finance
Tender Value Ref. Documents
Tender Fee 2500
EMD 50000
Exemption Not Available
Document List
Tendernotice_1.pdf
8d9a1873-05b3-49d2-ac9d-ae077c88038b.html
BOQ_991357.xls
Preliminaryagreement.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 29, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 01, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 01, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 03, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

8d9a1873-05b3-49d2-ac9d-ae077c88038b.html

xls

BOQ_991357.xls

pdf

Preliminaryagreement.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders