Tender For Repair/Maintenance Of Apfc Panel, Earthing, Lighting Arrester, Electric Cabling For Certain Location And Other Connected Works Under Ge (West) Bareilly, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Apfc Panel, Earthing, Lighting Arrester, Electric Cabling For Certain Location And Other Connected Works Under Ge (West) Bareilly. Submission Date for this Tender is 27-02-2024. Electrification Work Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41762344
Corrigendum : Tender For Repair/Maintenance Of Apfc Panel, Earthing, Lighting Arrester, Electric Cabling For Certain Location And Other Connected Works Under Ge (West) Bareilly
Open Tender
Indian
Uttar Pradesh
bareilly
27-02-2024

Tender Details

Tender For Repair/Maintenance Of Apfc Panel, Earthing, Lighting Arrester, Electric Cabling For Certain Location And Other Connected Works Under Ge (West) Bareilly

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Feb-2024 Date Date 20-02-2024
2 20-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 97980.0 /-
Tender Value
INR 48.99 Lakhs /-

BOQ Items

Name of Work:REPAIR/MAINT OF APFC PANEL, EARTHING, LIGHTING ARRESTER, ELECTRIC CABLING FOR CERTAIN LOCATION AND OTHER CONNECTED WORKS UNDER GE (WEST) BAREILLY
Sl. No. Item Description
1Taking/out old Unsv copper/GI/Alminium strip of any description from its oroginal position complete all as specified and directed.
2Taking/out old Unsvair terminal of any descriptionfrom its oroginal position complete all as specified and directed.
3Taking/out old Unsvtest terminal block of any description from its oroginal position complete all as specified and directed.
4Supply and fixing Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed.
5Supply and fixingTest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
6Supply and fixing Copper strip 20 x 3.15 mm with saddles and fixing screws etc.for roof conductors and down conductors above ground complete all as specified and directed.
7Supply and fixing copper strip 32x6 mm with burried in to ground for ring conductor and necessary jointiong work shall be carried out by brazing work complete all as specified and directed.
8Supply and fixing Galvanisedstrip 32x6 mm with burried in to ground for ring conductor and necessary jointiong work shall be carried out by brazing work complete all as specified and directed.
9Supply and fixing Aluminiumstrip 25x3 mm with burried in to ground for ring conductor and necessary jointiong work shall be carried out by brazing work complete all as specified and directed.
10Earthing complete with using copper plateplate electrode 60×60cm×3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to copper strip of size 20x3mmby means of boltsnuts, check nuts and washers of SS/ brass all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed..
11S&F in replacement ofMCCBDPX 630 MCCB with electronic Sg (Lsig)with protection unit415 Volts 4 pole 630 Amps 50 Hz with breaking capacity50 KAalongwith spreader terminalwithincluding lugs/thimbles of suitable size in existing panels complete all as specified and directed. (Note :- Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor.)
12All as per Item Ser No 11 here-in-before but of MCCB 400 Amps 4 pole 50 Hz 415 V, 50 KA complete all as specified and directed.
13All as per Item Ser No11 here-in-before but of MCCB 320 Amps 4 pole 50 Hz 415 V, 36 KA complete all as specified and directed.
14All as per Item Ser No 11here-in-before but of MCCB 250 Amps 4 pole 36 Hz 415 V, 25 KA complete all as specified and directed.
15All as per Item Ser No11 here-in-before but of MCCB 160 Amps 4 pole 50 Hz 415 V, 25 KA complete all as specified and directed.
16All as per Item Ser No11 here-in-before but of MCCB 100 Amps 4 pole 50 Hz 415 V, 25 KA complete all as specified and directed.
17M& L for replacementof Air circuit breaker 4 pole with microprocessor release of capacity800 Amps 50 kA415 V, DMX SP 2500 with manual operation , neutral overload protection OFF-50% -100%by removing out theexisting after taking proper electric shut downand commissioningthe same incl all minor parts as reqd for fixingnew ACBcomplete all as specified and directed.
18Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and directed.
19Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
20Removing of excavated soft/loose soil not exc 50 m & depositing where as directed at a level n.exc 1.5 m above from starting point completed all as specified and directed.
21M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches, punning complete all as specified and directed (Note:- Punning thickness of 18 cm will be considered for payment.)
22M & L for brick protection to cable using old size fly ash bricks, laid flat/length wise perpendicular to the axis of cable complete all as specified and directed.
23Laying only oldbricks for protection of cablecomplete all as specified and directed.
24Supply and laying in replacement ofXLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area240 Sq mm 3.5 core complete all as specified and directed. ( Note :- Rate deemed to be inclusive of connection including cable glands and lugs.)
25All as per Ser item No 24 here-in-before but 185 Sq mm 3.5 core complete all as specified and directed.
26All as per Ser item No 24 here-in-before but 150 Sq mm 3.5 core complete all as specified and directed.
27All as per Ser item No 24 here-in-before but 120 Sq mm 3.5 core complete all as specified and directed.
28All as per Ser item No24 here-in-before but 95 Sq mm 3.5 core complete all as specified and directed.
29All as per Ser item No 24 here-in-before but 25 Sq mm 4 core complete all as specified and directed.
30Taking up, down LT UG cable and relaying only serviceableLT UG Cable of any size and discription includingnecessary cable lugs complete all as specified and directed. (Note :- All relevent items like excavation, earth work etc shall be paid and measured seperately)
31M&L for PCC type B1, 1:2:4 (using 20 mm graded satone aggregate) as in coping to the poles complete all as specified and directed.
32S & F in replacementGI pipe light grade of following dia for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed. (a)50 mm dia complete all as specified and directed.
33(b) all as per item No. 32 but of size80 mm dia complete all as specified and directed.
34(c) all as per item No. 32 but of size 100 mm dia complete all as specified and directed.
35M&L for earthing complete with galvanised iron steel earth plate of size600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below ground level connected to thick electrode and 32x6 mm GI strip as earthingby means of nuts bolts check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore (medium grade) and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 precast RCC cover slab 54 x 54 cm x 5 cm with reinforcement with 8 mm TMT bars @ 150 C/C with one handle and funnel for watering charcoal or coke and salt in alternate layers & necessary earth work in soft/loose soil complete all as shwon in electrical plate No 3 of SSR Part-I including testing on completion all as specified and directed.
36M&L for replcement of Intelligent power factor controller1001-108-90V/550 Vac complete with all necessary connection and remoing of old existing complete all as specified and directed.
37M&L for replcement of CT suitable for APFC panel of cap 200A/5A Cl 1.5 VAcomplete with all necessary connection and remoing of old existing complete all as specified and directed.
38M&L for replcement ofsuper heavy duty MPP capacitors gas filled suuare type of cap10 kVAr complete with all necessary connection and remoing of old existing complete all as specified and directed.
39M&L for replcement ofsuper heavy duty MPP capacitors gas filled suuare type of cap15 kVAr complete with all necessary connection and remoing of old existing complete all as specified and directed.
40M&L for replcement ofsuper heavy duty MPP capacitors gas filled suuare type of cap 20 kVAr complete with all necessary connection and remoing of old existing complete all as specified and directed.
41M&L for replcement ofsuper heavy duty MPP capacitors gas filled suuare type of cap 25 kVAr complete with all necessary connection and remoing of old existing complete all as specified and directed.
42M&L for replcement ofsuper heavy duty MPP capacitors gas filled suuare type of cap 30 kVAr complete with all necessary connection and remoing of old existing complete all as specified and directed.
43M&L for replcement ofMCB triple pole 415 V for AC application 40 Amps C curve 10 kA completewith all necessary connection and remoing of old existing complete all as specified and directed.
44M&L for replcement ofMCB triple pole 415 V for AC application32 Amps, C curve, 10 kA completewith all necessary connection and remoing of old existing complete all as specified and directed.
45M&L for replcement ofMCB triple pole 415 V for AC application63 Amps, C curve, 10 kA completewith all necessary connection and remoing of old existing complete all as specified and directed.
46Disconnection of electric connection fromAPFCPanel of any size dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt etc complete including all inter connection withcopper cablesuitable current ratingincluding painting of Panels incl welding workif reqdcomplete with inner & outer with two coats ofsynthetic enamelled paintover a coat of primer including excavation & earth work required for taking out & refixing the incoming and out going cable etc complete allas directed. ( Note :-Replacement of unserviceable accessoriesie capacitors, MCCBs etcshall be measured and paid separately under relevent items.)
47Supply, installation, commissioning and testing in replacement of APFC panel of capacity 120 KVAR ( 25 KVAR X 2, 20 KVAR X 2, 10 KVAR X 2, 5KVAR X 2,)( FAFA) powder coated factory made outdoor type of suitable size made of CRCA sheetmade from min 3.15 mm thick sheet CPRI manufactureswith countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:- (a) Incoming MCCB 4 pole 250 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nos (b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No. (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor. (e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank) (f) Auto/Manually switch of capacitor bank (g) PCC 1:2:4 for installation of panel
48Supply, installation, commissioning and testing in replacement of APFC panel of capacity 150 KVAR( 25 KVAR X 2, 20 KVAR X 3, 10 KVAR X 3, 5 KVAR X2,) ( JAT HOUSE) powder coated factory made outdoor type of suitable size made ofCRCA sheetmade from min 3.15 mm thick sheet CPRI manufactures with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay complete panel prewired with suitable size of copper cable not less than 2.5 sqmm and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, PCC (1:2:4) type C-1 with 20mm graded stone aggregate.Panel comprising with following:- (a) Incoming MCCB 4 pole 350 Amp 35 KA alongwith Spreader terminals with adjustable thermal setting– 01 Nos (b) Multifunctional 4 in 1 meter like Amp,Voltage, frequency, powerfactor as per capacity of panel = 01 No. (c) Phase Indicator Lamp RYB with sheds LED Type - 01 Set of three (d) Capacitor MPPH type with suitable size 3 phase power contactors and with individual 3 pole 415 volt MCBs of suitable capacity including indication lamp of each capacitor. (e) Microprocessor based 3 phase current transformer sencing relay 8 stage = 01 No( for operating of capacitor bank) (f) Auto/Manually switch of capacitor bank (g) PCC 1:2:4 for installation of panel
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail