| 1 | Supplyof PVC Insulated and PVC Sheathed/ XLPE Power Cable of 1.1 KV grade of 3.5 Core 300 Sq mm Aluminum Conductor cable on wall surface as required. |
| 2 | Laying & fixing of PVC Insulated and PVC Sheathed/ XLPE Power Cable of 1.1 KV grade of 3.5 Core 300 Sq mm Aluminum Conductor cable on wall surface as required. |
| 3 | Supply & Installation of Main Distribution Board Panel, comprising of 2 Nos 400 A, I/Comer 6 Nos 200 Amp O/g feeder with 4 pole MCCB\"s, Bus Bar, 1 No 3 LCD Phase Energy Meter along with CT suitable for above, 8 Nos of 3 Phase Multifunctional meters along with CT suitable for above, 3 Nos LED Phase indicators etc. as required, (as per drawing enclosed) |
| 4 | Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. |
| 5 | Providing and fixing 100 A, 16kA, TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 6 | Supplying and fixing 16 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 7 | Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 8 | Supplying and fixing Single Pole 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 9 | Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 16 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 12 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 13 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 14 | Supplying & Drawing UTP- 4 Pair Cat 6 LAN Cable in the surface/recessed PVC conduit medium class PVC conduit as required |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (GROUP C) |
| 16 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch & 1 Nos 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 17 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Nos 5/6 amps modular socket outlet and 3 Nos 5/6 amps modular switch, connection etc. as required. |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 No RJ-45 Jack Cat 6(for LAN) modular socket outlet, connection etc. as required. |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 1 Nos 5/6 amps modular socket outlet and 1 Nos 5/6 amps modular switch, connection etc. as required. |
| 20 | Supply & Installation of exhaust fan-12\" in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing Modular Stepped type electronic Fan Regulator including connection etc. as required. |
| 22 | Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 300 sq. mm (70 mm) of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 23 | Supply and fixing 63 Amp rating, double pole single phase and neutral) 240 Volt resudual current circuit breaker(RCCB) having the 30 Main the exisiting MCB DB complete with connection, testing and commissioning etc. as required. |
| 24 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
| 25 | Earthing with copper earth plate 600mmX600mm x 3 mm thick including accesories and providing masonary enclosure with cover plate with locking arranment with watering pipe with 2.7 mtr longh. |
| 26 | Providing and fixing 25 mmX 5 mm copper strip on surface or in receces and connection as required. |
| 27 | Supply and fixing PVC batten/angle holder including connection etc as required. |