Tender For Repair And Maintenance To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Coolers, Refrigerators, Ac Plant And Voltage Stabilizers Etc At Military Station Fazilka., fazilka-Punjab

Military Engineer Services-MES has published Tender For Repair And Maintenance To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Coolers, Refrigerators, Ac Plant And Voltage Stabilizers Etc At Military Station Fazilka.. Submission Date for this Tender is 16-02-2024. Air Conditioner Tenders in fazilka Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41734525
Corrigendum : Tender For Repair And Maintenance To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Coolers, Refrigerators, Ac Plant And Voltage Stabilizers Etc At Military Station Fazilka.
Open Tender
Indian
Punjab
fazilka
16-02-2024

Tender Details

Tender For Repair And Maintenance To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Coolers, Refrigerators, Ac Plant And Voltage Stabilizers Etc At Military Station Fazilka.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
INR 12 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT TO SUMMER APPLIANCES SUCH AS AIR CONDITIONERS, WATER COOLERS, DESERT COOLERS, REFRIGERATORS, AC PLANT & VOLTAGE STABILIZERS ETC AT MILITARY STATION FAZILKA.
Sl. No. Item Description
1M & L for annual servcing of split AC/Window AC/Water Cooler/Refrigerator/Deep Frezzer any capacity by disconnecting electric connection from its stabilizer or its electric supply board and cleaning it with pressurised water and nylon brush then apply one coat of descaling solution and cleaning with nylon brush to the condensing coil shall be properly carried out damaging other parts, cheking and making serviceable electrical connection of DB, stabiliser,and tightening of loose connection complete.
2Taking down old and unserviceable sealed compressorand Supply & fixing ofnew sealed compressor hermetically of capacity 150/150 Ltrs,Suitable for water cooler , including cleaning ,Vaccumizing, Gas charging of adequate qty with Testing on load complete all as specified and directed by Engr-in-Charge.make : Kirloskar/Tecumsah/LG/Godrej.
3All as per description of Srl item No2 above here-in-before but sealed unit compressor suitable for water cooler capacity 120 Ltrs,all as directed by Engr-in-Charge.
4All as per descrirtion of Srl item No 2 above here-in-before but sealed unit compressor suitable for water cooler capacity 40/80 Ltrs,all as directed by Engr-in-Charge.
5Labour only for attending complaints of Air Conditioner/Water Cooler/refrigerator/deep Freezer carried out by manufacture"s authorised mechanic from servicing center without any delay with rectified the defects by carefully opening and check the Acs for smooth functioning complete all as specified and directed. Note :- Items shall measure and paid seperatrly under respective item of BOQ.
6Supply & fixing in replacement of Fan motor of as existing capacity and as per site rquirement of water cooler. Make : Danfoss/Ranutrol/Anapurna complete all as specified and directed by engr-in-charge.
7Material & labour for charging of refrigerant gas in Water cooler of capacity 150/150 ltrs including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
8Material & labour for charging of refrigerant gas in Water cooler of capacity 60/120 ltrs including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
9Supply & fixing in replacement Water taps brrass chromium plated heavy duty Internal thread / outer thread for 15mm bore pipe, all as specified and directed by Engr-in-Charge. Make : Jindal/Johnson.
10Material and Labour for Replacement of thermostat switch with knob for water cooler any cap.
11Material and Labour forReplacement of starting capacitor 60 Mfd oil filled240 volt AC Supply.
12Material & labour for charging of refrigerant gas in Water cooler of capacity 40/80 ltrs including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
13Material and Labour for Replacement of copper filter and capillary tube of water cooler any capacity.
14Material and Labour for Replacement of running capacitor of 10 Mfd oil filled.
15Material and labour for replacement of fan blade for condensing fan motor (as per sample) suitable for water cooler any cap.
16Material and Labourforcondenser unit complete suitable for 150/150 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing,welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
17Material and Labourforcondenser unit complete suitable for 60/120 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing,welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
18Material and Labourforcondenser unit complete suitable for 40/80/ Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing,welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge
19Taking down old and unserviceable sealed compressor and Supply and fixing new hermetically sealedcompressor suitable for 1.5 ton window type AC complete including accessories and cleaning , vaccumizing ,gas charging of adequate qtyin the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge.Make :Gujral /Carriar/Voltas/Sidhwal/Tecumsah.
20All as per description of srl item No 19 here-in-before but suitable for split type AC of 1.5 Ton.
21Material & labour for charging of refrigerant gas in Window type / Split type Ac 2.0 Ton cap including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
22Material & labour for charging of refrigerant gas in Window type / Split type Ac 1.5 Ton cap including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
23Supply & fixing indoor unit of Split Type AC of capacity 1.5 Ton Including cooling coils fan motor, PCB plate, drain out pipe and connecting items,complete all as specified and directed by Engr-in charge. Make : Voltas/Blue Star/Gujral/LG.
24Supply and installation of Insulation pipe highly flexible pipe closed cellnitrile rubber Suitable forsuction /discharge copper tubes of 1.5 TR/2 TR split AC including PVC self adhesive whit mansoon tap overthe insulation tap Complete .Make Armacell
25Supply & fixing outdoor unit for Split Type AC of capacity 1.5 Ton Including compressor , fan motor, copper pipe of 6 mtr length and connecting items,complete all as specified and directed by Engr-in charge. Make : Voltas/Blue Star/Gujral/LG.
26Material and labour for replacementof copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing
27Material and labour for replacementof copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing
28Material and labour for repairing of PCB card for split AC /Window type AC of cap 1.5 TR all as specified and directed.
29Material and labour for repairing of PCB card for split AC /Window type AC of cap 2.0 TR all as specified and directed.
30S&F Condensor fan motor of Speed 900 RPM of window/Split Air conditioner of cap 1.5/2.0 TR
31S&F Swing motor for indoor unit of window/Split Air conditioner of cap 2 TR
32S&F Swing motor for indoor unit of window/Split Air conditioner of cap 1.5 TR
33S&F running capacitor clip type of cap. 50/2+4+6 MFD, 240 volts 50 cycles for window type/Split typeair conditioner 1.5/2.0 TR.
34S&F Over load protector with relay for 1.5 Ton cap for window/Split type AC.
35S&F Over load protector with relay for 2.0 Ton cap for window/Split type AC.
36S&F Thermostat switch for window/Split AC cap.1.5TR.
37S&F Thermostat switch for window/Split AC cap.2.0 TR.
38S&F Blade of condensing fan motor for window/split type (outdoor unit) AC cap1.5 TR.
39S&F Blade of condensing fan motor for window/split type (outdoor unit) AC cap2.0 TR.
40S&F Display unit for 1.5 Ton Split/Window AC.
41S&F Display unit for 2 Ton Split/Window AC.
42S&F blower motor of indoor unit of split type of cap 1.5 TR
43S&F blower motor of indoor unit of split type of cap 2 TR.
44S&F Compresser Capacitor as per existing for 1.5 Split type AC
45S&F Compresser Capacitor as per existing for 2.0 Split type AC
46S&F Drain pipe as per existing for 1.5/2.0 Split type AC
47Supply and fix voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.Make: V guard VND 500 or equivalent in blue bird or microtech.
48Supply and fixing new hermetically sealedcompressor suitable for Refrigerator of capacity 286/310 Ltrs complete including accessories and cleaning , vaccumizing ,gas charging of adequate qtyin the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge.Make:-Kirloskar/Teccum Sah/Sriram/Godrej/Samsung/whirlpool /LG
49All as per item No 48 above but for Refg of capacity 190/220 Ltrs.
50S & F cooling coil of Refrigerator Capacity 280 Ltrs including connected works complete all as specified and directed by Engr-in-charge.
51Material & labour for charging of refrigerant gas in Refrigerator of 286/310 ltrs size including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
52Material & labour for charging of refrigerant gas in Refrigerator of 190/220 ltrs size including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
53All as per item no. 52 but for cap. 280 lts complete all as specified and directed by Engr-in-charge.
54All as per item no. 52 but for cap. 310 lts complete all as specified and directed by Engr-in-charge.
55Supply and fixing new hermetically sealedcompressor suitable for Deep Freezer of capacity 500 Ltrs complete including accessories and cleaning , vaccumizing ,gas charging of adequate qtyin the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engr-in-Charge.Make:-Kirloskar/Teccum Sah/Sriram.
56All as per item No 55 above but for D Freezer of capacity 300 ltrs complete all as specified and directed by Engr-in-charge.
57All as per item No 55 above but for D Freezer of capacity 200 ltrs complete all as specified and directed by Engr-in-charge.
58Material & labour for charging of refrigerant gas in D freezer of any size including pressure/leak testing etc complete all as specifiedand directed by Engr-in-charge.
59Supply & Fixing in Replacement of Fan motor of capacity 1/8 HP,1400 RPM, three speed suitable for desert cooler .
60Supply & Fixing in Replacement of Submersible water pump (Tullu pump) single phase ,220 V for desert cooler complete all as specified and directed by Engr-in-charge.
61Supply & fixing Wood wool pad for desert cooler of any sizecomplete set of three superior quality as approved by Engr-in-Charge.
62Replacement outer body of desert cooler of standard size made of GI sheet 2 mm thickness including fan motors,tullu pump, side Shutters, legs and front grill with (Selector switch,and piano type switch) accessories, nuts and bolts complete all as specified and directed by Engr-in-Charge.
63Removing Old paint of Desert Cooler internally and externally, preparing new galvanized surface for painting and applying two coats of synthetic enamel paint over a coat of red oxide using spray gun complete all as directed by Engr-in-Charge.
64Supply and fixing Starting Capacitor mfd 80-100 Mfd for water cooler and D freezer. Make Bhel/Keltron/Tibcon.
65Supply and fixing Running capacitor 10 to 20 Mfd for"D" Freezer.
66Supply and fixing over load protector suitable for Deep freezer and Refrigerator , Complete all as specified and directed by Engr-in-charge.
67Supply and fixing Thermostats switch as per site rquirement for water cooler and Acs of any capacity complete all as specified and directed by Engr-in-charge.
68Supply and fixing Thermostats switch Suitable for D freezer and Refrigerator complete all as specified and directed by Engr-in-charge.
69Supply and fixing Starting relay Suitable for Refrigerator and Deep Freezer complete all as specified and directed by Engr-in-charge
70Supply and fixing Biometal fuse suitable for Refrigerator complete all as specified and directed by Engr-in-Charge.
71Supply and fixing Timer suitable for Refrigerator complete all as specified and directed by Engr-in-Charge.
72Supply and fixing PVC pipe ( 15 mm ) for desert cooler complete all as specified and directed by Engr-in-charge.
73Supply and fixing Starting capacitor 4 mfd heavy duty.Make : Usha/Tibeon/Keltron
74Supply and fixing Metal Clad Industrial Plug ( Male) 2 Pole + Earth,250 Volts for Acs & Geyser,
75Supply and fixing Metal Clad IndustrialSocket ( Female) 2 Pole + Earth,250 Volts for Acs & Geyser,
76Supply and fixing water distributer for desert cooler of size 1/2" Make ISI Mark
77Supply and fixing elbow (PVC) set for desert cooler of size 1/2" Make ISI Mark
78Supply and fixing PVC connection of 15mm bore &600 mm length for connecting main pipe line suitable for Desert coolerwith PTMTMake ISI mark.
79Supply and fixing 3 Pin Triangular Plug Top 6 Amp ,240 Volts.
80Supply and fixing 3 Pin Triangular Plug Top15/16 Amp ,240 Volts.
81Supply and fixing sheet Metal enclosure with socket plug top and MCBs 20 Amp single pole (AC box) Make : Indoasian/Havells
82Repair/Replacement of cooling coil copper type of window type AC including connected work complete all as specified and directed by Engr-in-charge.
83Repair/Replacement of condenssor coil copper type of window type AC including connected work complete all as specified and directed by Engr-in-charge.
84REPAIR/MAINT FOR CEILING/EXHAUST FANS
85Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweepdown rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan,cutting the unserviceable winding of starter, rotor and taking out ball bearing, gun metal bush etc. complete to carry out the following repairs:-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as specified and directed and re-assembling complete ceiling fan fixing only with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- 1. Ball bearing, Gun metal bushand condensor are measured and paid separately as supply only rates and minor spares like rubber bush shackle,holder deemed to beinclude in quoted rates). 2.Repair/Rewinding of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
86All as per Item No.85 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
87All as per Item No.85 here-in-before but pedestal/Air circulator fan of size 400/450/600 mm sweep.
88Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bush, bearing, condenser complete all as specified and directed and writing MES number as as directed by Engr-in-Charge. (Note :1. Bush, condensor, ball bearing are measured and paid separately as supply only rates and minor spares like , rubber bush shackle,holder deemed to be include in quoted rates ) 2.Repair/Servicing of fan shall be carried out in MES yard/User site to bring adequate serviceable condition winding machine,tools & plants and necessary motor winder at site as directed.
89All as per item No 88 here in before but exhuast fan 220/250/300/380/450 mm sweep complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge
90Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweepdown rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, including filling the cavities with filler material and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge. Note: 1.painting of fan shall be carried out in MES yard/User site to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
91All as per Item No.90 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
92All as per Item No.90 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep.
93Supply and fixing in replacement of PCB (Panel circuit board) suitable for BLDC ceiling fan of 1200 mm sweep ISI marked duly housing in side ceiling fan body after taking down and fixing the ceiling fan after serviceble position complete all as specified and directed.
94Supply and fixing in BLDC ceiling fan of 1200 mm sweep complete all as specified and directed.Make : Havells/Bajaj/Crompton
95Supply only ball bearing number of 6201/6202/6203/6204 as required complete all as specified and directed. (Make : SKF/NBC).
96Supply only gun metal bush as per existing specification and make as per sample and confirming to ISI complete all as specified and directed.
97S&F for Condenser 2/2.5/3.15.4.0 MFD with PVC housing as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed.(Make : Universal/Standard/Jyoti/Usha)
98S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
99S&F for twin core twisted copper flexible wire/cable of size 23/0.0076 complete all as specified and directed(Make : Finolex/Nicco/KDK/KEI/Havells/HPL)
100Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make
101Supply only canopy top/bottom with U clamp suitable for ceiling fan 1200/1400mm sweep suitable matching color as exising complete all as specified and directed
102Supply only down rod 300 mm long of size 20 mm dia for ceiling fan complete all as specified and directed.
103Supply only ceiling fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
104Supply only Exhasust fan blades suitable for 240/300 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
105Supply only exhaust fan canopy suitable size as per exising size of fans 220/250/300/380/450 mm suitable to matching color complete all as specified and directed
106Supply only exhaust fan Louvers MS suitable to size as per exising fans 220/250/300/380/450 mmcomplete all as specified and directed