Tender For D/O Vill S (Providing Distribution Line Network In Vill-Bishanpura) Sector-58, Noida, noida-Uttar Pradesh

New Okhla Industrial Development Authority-NOIDA has published Tender For D/O Vill S (Providing Distribution Line Network In Vill-Bishanpura) Sector-58, Noida. Submission Date for this Tender is 01-02-2024. Pipe Laying Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41732517
Tender For D/O Vill S (Providing Distribution Line Network In Vill-Bishanpura) Sector-58, Noida
Open Tender
Indian
Uttar Pradesh
noida
01-02-2024

Tender Details

D/O Vill S (Providing Distribution Line Network In Vill-Bishanpura) Sector-58, Noida

Key Value

Document Fees
INR 5310 /-
EMD
INR 380700.0 /-
Tender Value
INR 1.90 Crore /-

BOQ Items

Name of Work:-: D/o Vill"s (Providing Distribution line network in Vill-Bishanpura) Sector-58, Noida.
Sl. No. Item Description
1Supply, Insallation, Testing and Commissioning of 185 Sq.mm. 3 Coretype high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment required for proper completion of the work. (KEI/Diatron/Gloster/Universal/Havells.Polycab make) (UPERC)-2019 P-41
2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of upto 120 sq.mm to 400 sq.mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (DSR-2018) 8.1, P-31 above 120 sq.mm upto 400 sq.mm
3S/F of jointing of 185 sq.mm outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson/ Make)Outdoor Type. (UPERC ) P-41
4Supply and fixing of following type plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer- Incharge. UPPWD-2019 (PS No. 504) -1. 185 Sq.mm.
5S/F of Steel Tubular Pole 11 M long designated 410-SP-56 in 1:3:6 Cement, Concrete graded stone aggregate of 40 mm. Nominal size & foundation including excavation back filling etc. complete in all respects as per direction of E/I.(UPERC-2019 Pg-44)
6Supply and burying earth electrode for lighting conductor of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineerin- charge complete in all respect. UPPWD-2018 PS-706
7S/F of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects as per direction of E/I UPPWD-2018 (PS-716)
8Painting of the electric pole with 2 coats of aluminium paint after cleaning of pole. Complete in all respects as per direction of E/I. UPPWD-2018 P.S. No. 634
9Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete in all respects. UPPWD-2018 PS-627
10S/F of 11 KV pin 12" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39
11Providing & Laying of 200 mm dia 6 mm thickness thorugh trenchless method including joints of pipe, excavation of thrust pit and receiving pit of required size, cutting and repairing of road with all T & P and the GPS report submitted by the tendere before excavation & back filling with compaction complete as per specification by H.D.D. machine method. Pipe will be installed at minium depth 2 M to 3M below the ground surface or download as per site condition in required slope.(AOR)
12Supply and fixing of 150 mm. dia. G.I. Pipe B Class for cable duly clamped with supports by 1 Nos. with clamps of 20x3 mm. M.S. Flat, bolts, nuts and washer required for proper completion or work. UPERC-2019 Page-30
13S/Laying of Heavy density poly ethylene Pipes ISI marked anti radiant grade OD -160 mm dia PN-8 PE 100 grade as per IS Code 4984 with excavation at the depth of 1.20 mtr below ground level i/c the cost of cutting of pipes for making up to length and making jointcomplete in all respects. As per direction of E/I. Rex/Duraline/Time make (AOR)
14Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Complete in all respect as per direction of E/I. Above 10 Mtr and 12 Mtr DSR-2018(Electrical) 11.3.4
15S/L of Al. armoured cable PVC insulated Ar. served & sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I.Complete in all respects . The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Make -Polycab/Plaza/ Havells. (PS No. 501) UPSR -2018 -a)- 16 sq. mm 2 core
16(r) 240 sq. mm 3-1/2 core
17b)- 400 sq. mm 3.5 core
18S/F of Plain or Pin type copper tin plated cable socket (Lug)to the cable lead, insulating with tape and making connector etc. Complete in all respects as per Direction of E/I (PS No. 504) UPSR-2018 -a)- 16 sq. mm
19b)- 400 sq. mm
20Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. E/I. UPPWD-2018 PS No. 1423 Catt-AAA
21Supply and fixing 15A TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPNcomplete in all respects including painting with aluminium paintUPPWD-2018, PS-807
22Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. DSR-18 (Elect.) Item No-14.16 -a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR-18 (Elect.) Item No-14.16.1
23b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR-18 (Elect.) Item No-14.16.2
24Supply and burying of 600 mm x 600 mm x 6.0 mm GI plate, vertically for eathing with its top at least 3 meters below ground level complete with 20 mm dia. GI Pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG GI wire in 12 mm. dia. GI Pipe up to switch board (from appron to switch board the cost of GI pipe and GI wire will be extra) 30 cm. square GI Frame with hinged cover, masonry housing, alternate layers of charcoal/coke and salt at least 150 mm. thick alround etc. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-702
25Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.. as per direction of Engineer-in-charge complete in all respects (This will apply for earthing of poles also). UPPWD-2018, PS-725B
26Supplying and embedding following dia G.I. pipe 32 mm dia(medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. DSR-2018, 11.6.1
27S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.24 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. UPERC-2019 P-24
28S/F of 11 KV TPMO Relco/Rama make 9 Nos. insulator of Jai shree/BHEL/Rama/ Rastriya make complete in all respects as per direction of E/I UPERC-2019 Page No-48
29S/F of out door type 11KV fuse set with insulator Jai shree/ BHEL make complete in all respects as per direction of E/I. Relco/ Rama/Rastriya /UPPCL approved make (AOR)
30S/F of 11 KV Disc insulator 70 KN or 7000 Kg. and fitting B&S heavy duty with clamp of cross arm fixed on HT Pole.UPERC-2019 Page no-48
31Supply & erection of "D" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paintUPPWD-2018, PS-623
32S/E testing & commissioning of 400 KVA copper wound outdoor type distribution transformer as per ISS : including inspection fees etc. complete in all respect Make: Crompton/Alstom/ABB/ Schneideras per direction of E/I. (UPER-2019) pg-51
33M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53
34FRP Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53
35Plinth of Transformer as per direction of E/I. (UPER-2019) pg-53
36Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3 mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect.P.S. No-641
37Supply & Fixing of XLPE Insulated Al. unarmoured Cable for working voltage for energizing the distribution boxes & Street light size of 1x16 sq.mm. complete in all respect as per direction of E/I. AOR
38Providing and fixing ofM.S. Special such as Tee, Bends, collars, Tapers, Gap pieces including Flange ends as required, painting, cutting, welding as per site requirement of MS pipe thickness etc. complete in all respect as per direction of E/I. (AOR)
39Cement concrete with 4 cm gauge approved stone ballast coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & Plants etc. Required for proper completion of the work. (SOR)
40Excavation in foundation in ordinary soil (Loam, clay or sandy) including lift upto 1.50 M and lead upto 30 M. And including filling watering and ramming of excavated earth into the tenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E/I upto a distance of 30 M. from the foundation trenches (Where machine con not reach/move) For Building work only as in item 251A P.W.D. (SOR)
41Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR-2018 12.34
42Supply of PCC pole 9 Mtr UPERC-2019 Page No-43
43Supply of Danger Borad with Clamp UPERC-2019 Page No-45
44Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories forhigh mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor platesetccomplete in all respect as per direction of E/I. UPPWD-2018, PS-651
45Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection. UPPWD-2018, PS-1455 CAT-AAA
46Supply & Laying of 1100 V grade Aerial Bunched Cable. Power Cable : Standed compacted circular aluminium conductor, XLPE insulated 1 Messenger conductor, Standed compacted..direction of E/I. AOR
47Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&Pcomplete in all respect as per direction of E/I. UPPWD-2018, PS-647
48Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR)
49Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I. (AOR)
Disclaimer :