Employees State Insurance Corporation-ESIC has published Tender For Special Repairs To Esi Hospital Mg Kavu, Thrissur.. Submission Date for this Tender is 31-01-2024. Water Pipe Line Tenders in mulamkunnathukavu Kerala. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m, as directed by Engineer-in-Charge. |
2 | All kinds of soil |
3 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
4 | All kinds of soil |
5 | Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. |
6 | All kinds of soil. |
7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
8 | 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
9 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
10 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification. |
11 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: |
12 | Foundations, footings, bases of columns, etc. for mass concrete. |
13 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
14 | Suspended floors, roofs, landings, balconies and access platform. |
15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
16 | Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
18 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
19 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : |
20 | With F.P.S.(non modular) bricks |
21 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
22 | 12 mm cement plaster of mix : |
23 | 1:4 (1 cement: 4 fine sand) |
24 | 15 mm cement plaster on rough side of single or half brick wall of Mix: |
25 | 1:4 (1 cement: 4 fine sand) |
26 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
27 | 1:4 (1 cement: 4 fine sand) |
28 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
29 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
30 | Painting with synthetic enamel paint of approved brand and Manufacture to give an even shade : |
31 | Two or more coats on new work |
32 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
33 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
34 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing surface |
35 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
36 | In cement mortar |
37 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : |
38 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
40 | 50 mm nominal outer dia Pipes. |
41 | 80 mm nominal dia Pipes |
42 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
43 | 50 mm nominal bore |
44 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : |
45 | 50 mm nominal bore : Horizontal |
46 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
47 | L D- 2.5, Rectangular shape 600x450 mm internal Dimensions |