| 1 | Replacement of old/frayed conductors |
| 2 | Reconductoring of LT Line |
| 3 | with ABC 3X95+1X70+1X16 sqmm, 3X70+1X50+1X16 sqmm,3X50+1X35+1X16 sqmm & 2x50 sqmm |
| 4 | Aerial Bunched Cable LT 3x95 + 1x70 + 1x16 sq.mm (Insulated Messenger) |
| 5 | Aerial Bunched Cable LT 3x70 + 1x50 + 1x16 sq.mm (Insulated Messenger) |
| 6 | Pole PSC 8 M |
| 7 | Pole PSC 9 M |
| 8 | Suspension Clamp Assemblysuitable for insulated messenger of sizes70 sq.mm, 50 sqmm & 35 Sqmm. |
| 9 | Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes70 sq.mm, 50 sqmm & 35 Sqmm. |
| 10 | Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement |
| 11 | Pre-insulated Bi metallic lug for 95 sqmm with brass nut and bolt |
| 12 | Pre-insulated Bi metallic lug for 70 Sqmm with brass nut and bolt |
| 13 | Pre-insulated Bi metallic lug for 50 Sqmm with brass nut and bolt |
| 14 | Pre-insulated Bi metallic lug for 16 Sqmm with brass nut and bolt |
| 15 | 1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable |
| 16 | Distribution Box for service connection |
| 17 | Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way) |
| 18 | Insulation Piercing Connector ( IPC Connector): For ABC to Distribution box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm |
| 19 | Insulation Piercing Connector (IPC Connector): For ABC to ABC/BareMain 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm |
| 20 | Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/EarthingMain 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm |
| 21 | 11 kV COMPOSITE POLYMERIC PIN INSULATOR |
| 22 | 11 kV V cross arm with GI Clamps, Bolt & Nuts with washers |
| 23 | Pole Top Bracket -F Type GI -11 kV |
| 24 | Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers |
| 25 | GI Stay Set includes (LT)1. Stay Insulator Porcelain 11 k V - 1 No2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI)3. STAY TIGHTNER LT4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod)6. Helically formed Guy-Grip LT7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work. |
| 26 | GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos2. Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI)3. STAY TIGHTNER HT4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)5. Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod)6. Helically formed Guy-Grip LT7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work. |
| 27 | G.I.WIRE. 4MM (8 SWG) |
| 28 | Coil Earth set includes1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm.3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work. |
| 29 | GI Pipe Earthing set includes1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe)2. Earth Chamber (RCC) With RCC Covering Slab3. Earth Connector suitable for Messengers size ranges from 35 Sqmm to 70 Sqmm.4. Crimping Socket Palm Type suitable for insulated stranded conductor-Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work. |
| 30 | RDSS Sign Board as per approved spec |
| 31 | Provision for Convertion ABC: |
| 32 | Replacement of old/frayed conductors |
| 33 | Conversion of LT Sph line to 3 Ph lines with ABC using 3X95+1x70+1x16sqmm, 3X70+1X50+1X16 sqmm & 3X50+1x35+1x16sq.mm |
| 34 | Aerial Bunched Cable LT 3x95 + 1x70 + 1x16 sq.mm (Insulated Messenger) |
| 35 | Pole PSC 8 M |
| 36 | Pole PSC 9 M |
| 37 | Suspension Clamp Assemblysuitable for insulated messenger of sizes70 sq.mm, 50 sqmm & 35 Sqmm. |
| 38 | Anchoring /Dead end Clamp Assembly suitable for insulated messenger of sizes70 sq.mm, 50 sqmm & 35 Sqmm. |
| 39 | Stainless Steel Strap 20mmX0.7mm along with Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm] shall also be supplied as per requirement |
| 40 | Pre-insulated Bi metallic lug for 95 sqmm with brass bolt & nut |
| 41 | Pre-insulated Bi metallic lug for 70 Sqmm with brass bolt & nut |
| 42 | Pre-insulated Bi metallic lug for 50 Sqmm with brass bolt & nut |
| 43 | Pre-insulated Bi metallic lug for 16 Sqmm with brass bolt & nut |
| 44 | 1.1 kV 1C X 25 sqmm unarmoured PVC Al Cable |
| 45 | Distribution Box for service connection |
| 46 | Satellite connector for service connection Main:16sqmm to 95sqmm,Tap:2.5 sqmm to 35sqmm(4 way) |
| 47 | Insulation Piercing Connector ( IPC Connector): For ABC to Distribution box & other service connection Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm |
| 48 | Insulation Piercing Connector (IPC Connector): For ABC to ABC/BareMain 16 sq mm to 95 sq mm; Tap 16 sq.mm to 95 sq.mm |
| 49 | Insulation Piercing Connector ( IPC Connector): For ABC to service connection/street light/EarthingMain 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm |
| 50 | 11 kV COMPOSITE POLYMERIC PIN INSULATOR |
| 51 | 11 kV V cross arm with GI Clamps, Bolt & Nuts with washers |
| 52 | Pole Top Bracket -F Type GI -11 kV |
| 53 | Channel cross arm GI 75x40x6mm 1.8M- with GI- Clamp Bolt & Nut with washers |
| 54 | GI Stay Set includes ( LT)1. Stay Insulator Porcelain 11 k V -1 No2. Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI)3. STAY TIGHTNER LT4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)5. Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod)6. Helically formed Guy-Grip LT7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work. |
| 55 | GI Stay Set includes ( HT) 1. Stay Insulator Porcelain 11 k V - 2 Nos2. Anchor Plate 200 x 200 x 8 mm GI (LT Stay Plate GI)3. STAY TIGHTNER LT4. Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)5. Stay Rod (Anchor Rod) GI 20 mm dia (LT Stay Rod)6. Helically formed Guy-Grip LT7. Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)8. Stay clamp (GI ) etc as required as per technical specification, approved drawings and scope of work. |
| 56 | G.I.WIRE. 4MM (8 SWG) |
| 57 | Coil Earth set includes1. Earthing Coil GI 115 Turns 50 mm internal Dia 2. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm.3. Ferrules 5 SQ.MM - GI etc as required as per technical specification, approved drawings and scope of work. |
| 58 | GI Pipe Earthing set includes1. Pipe GI 40 mm dia -2.5 m Length( Earth Pipe)2. Earth Chamber (RCC) With RCC Covering Slab3. Earth Connector suitable for Messengers size ranges from 35 Sqmm to 70 Sqmm.4. Crimping Socket Palm Type suitable for insulated stranded conductor-Al(Cable Lug) 5. Stainless Steel strap and Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm. etc as required as per technical specification, approved drawings and scope of work. |
| 59 | RDSS Sign Board as per approved spec |