Irrigation And Public Health Department has published Improvement Of Lis Kangru Padhru In Gp Baggi, Lis Beenat Patyani In Tehsil Balh Distt. Mandi (H.P) (Sh:- Providing, Laying, Jointing, Tesing & Carriage Ofms Pipe 200 Mm Dia (Phase-I) & Laying Jointing, Tesing & Carriage Of Gms 150Mm Dia (Phase-Ii)For Risi. Submission Date for this Tender is 29-01-2024. Pumping Machiney Tenders in Mandi Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Excavation in foundation,trenches (for pipes and pits) up toall depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing and pumping out water, blasting soft/hard rock or chiseling soft/hard rock where blasting is prohibited in all lifts including trimming & dressing of sides, levelling of beds to correct grade i/c shoring/ strutting,planking, timbering & dewatering wherever required, stacking theuseable of unuseable material/ soilseparately &after excavated soil clear from the edge of excavation returning the excavated soil after laying jointing testing of pipes in trenches in 15 Cm layers including consolidating of each deposited layer by ramming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of diversion for traffic,night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect with in all leads & lifts as per the entire satisfaction & directions of Engineer- in- Charge. |
2 | Providing and laying cement concrete 1:4:8 ( 1cement:4 sand: 8 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth complete in all respect with in all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. |
3 | Providing form work with steel plates 3.15mm thick welded with angle iron in frames 30x30x5mm so as to give a fair finish including centering, shuttering, propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for-in-situ reinforced concrete and plaiin concrete work in:- |
4 | Vertical surface such as walls (any thickness) partitions and the like includingattached pillasters, butteresses, plinth and string courses and the like complete in all respect. |
5 | Providing and laying Reinforced cement concrete work 1:2:4 (1cement: 2sand : 4 gradedstone aggregate 20mm nominal size) and curing complete excluding cost of form work in Foundation & plinth complete in all respect with in all leads and lifts as per the direction and satisfaction of Engineer-in-Charge. |
6 | Foundations, footings, bases of columns, etc. for mass concrete complete in all respect. |
7 | Providing Mild steel/Tor steel reinforcement for RCC work including bending, binding and placing in position complete up to floor two level in all respect with in all leads and liftsas per the direction and satisfaction of Engineer-in-Charge. |
8 | Rising Main :- (Phase-I) Providing, laying, fixing,jointing and testing in trenches MS pipe of following diameters confirming toconfirming to BIS 3183-2007, of following grade and having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in Charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
9 | 200 mm dia -MSERW -Pipe 4.00 mm thickness- F.T-17 (Grade L-290 or A) |
10 | Providing , laying,jointing (by way of circumfrential butt welded jointsby electrical arc welding) and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below(latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
11 | 200 mm dia -MSERW -Pipe 4.00 mm thickness (Grade L-290 or A) |
12 | Phase II- Laying,jointingand testing of GMS pipe of following diameters confirming to BIS 1239 (Part-1),grade specified below(latest with upto date ammendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes .providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
13 | 150 mm dia -GMS -Pipe(M) 4.80 mm thickness- F.T-28 |
14 | 150 mm dia -GMS -Pipe(M) 4.80 mm thickness- F.T-17 |
15 | Laying, jointing ( by way of circumfrential butt welded jointsby electrical arc welding ) and testing of GMS pipe of following dia meters confirming to BIS 1239 (Part-1),grade specified below(latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in Charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in Charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). |
16 | 150 mm dia -GMS Pipe(M) 4.80 mm thickness |
17 | Pumping machinery (Centrifugal Pump Set) Phase IInd - Supply of horizontal spindle horizontal radial split casing / and suctions (back pull out arrangement) Single / double / multistage centrifugal pumps or combination of pumps in series / parellel of KSB / Mathur & Platt / Jyoti / Kirloskar / BE / Maxflow / Beaconweir Sabar make conforming to BIS 5659-1970) pump (Latest with upto to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with bronze / Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring TEFC of electic induction motor/motor of standard make such as Kirloskar / NGEF / Cromption / Siemen / Jyoti / BHEL / GEC / ABB conforming to BIS 325-1978) read as BIS 900- 1972 and IS:12615:2011 with IE-2 specifications (latest upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the data given as below :- |
18 | DisCharge(Q) - 15.12 LPS for each pump, Total Dynamic heads:-192.07 Meter, a) LWL in sump well(h) - 843.46 Meter, b) Shaft Level- 842.86 Meter, c) Level at DisCharge point- 1007.79 Meter, d) Suction Lift - +ve, e) DisCharge Head -164.93 Meter, f) Static head - 164.93, Rising Main- a)Length - 2500 Meter, b) Dia- 150 mm, Pumping Hours - 20.00hrs, Altitude of installation above MSL - 840 Meter, Characterstics of water-Clear Water with turbidity up to 100 PPM |
19 | Supply , Installation, Testing and Commissioning of Star Delta Starter panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 1 Nos. pumps (1working) of the suitable rating through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: JSV approved |
20 | Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for suitable starter. Make:- JSV Approved |
21 | Voltage Protection device to protect panel from over voltage and under voltage Make:- JSV Approved |
22 | Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage. |
23 | Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication.Make:- JSV Approved |
24 | Main incomer MCCB ofsuitable capacity of L&T / Schnieder/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition). |
25 | Individual Starter incomer MCCB/MCB ofsuitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition). |
26 | LED three phase indicating lamps complete with ogg d switches for individual motors confirming to BIS 3452 ( part ammendments) |
27 | LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc. |
28 | Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges. |
29 | Control Transformer to provide a stable control volatge to safegaurd the control circuit of all the components from the voltage surges and spikes. |
30 | Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T |
31 | Providing double flanged CI sluicevalve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartarmake and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date ammendments) |
32 | Providing double flangedcast steel sluice valve, ASA-150 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Foursesmake and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
33 | Providing double flanged swing type cast steel reflux valve, ASA-150 of Leader/BHEL/ Kirlosker/Kilburn /GLEd/Foursesmake andhaving bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
34 | Providing double flanged cast steel reflux valves class,ASA-150 of Leader/BHEL/ Kirlosker/Kartar/Kilburn /GLEd/Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
35 | Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments. |
36 | Providing disCharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in Charge as per Is:2373:1981 with upto date ammendments. |
37 | Installation of all the items apparing as per the schematic drawing. |
38 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in Charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessoriesincluding rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under: |
39 | a) Suction pipe: One dia higher then the suction of pump offeredand suitable to keep thevelocity of flow from 1 to 1.5M/second in the suction pipe |
40 | b) Delivery pipe: One dia higher then the delivery of the pump offeredand suitable to keep thevelocity of flow from 1.5 to 2M/secondin the delivery pipe. |
41 | Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size andcapacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/ GLOSTER / IEC/ ICC/ EICO/ NATIONAL/ GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor. |
42 | (a) Motor side 3 core (From switch to starter and starter to motor) |
43 | (b) Supply side 3.5 core (From Meter of HPSEB to bus bar and switch) |
44 | Providing and fixing double loop earthing with GIplate 600mmx600x3mm thick electrode completewith material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
45 | PLC (Programmable logic controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter PanelMake : JSV Approved |
46 | Electronic relay card 8 channel |
47 | SMPS 4.5 Amps to energise PLC system |
48 | HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumpsMake:JSV Approved/Bechoff Automation/Rockwell |
49 | Control MCB for Automation System |
50 | Level Sensor to indicate the water level of tank remotely |
51 | Shielded Data Cable for Communication of Level Sensor with PLC |
52 | (Centrifugal Pump Set) Phase- Ist- Supply of horizontal spindle horizontal radial split casing / and suctions (back pull out arrangement) Single / double / multistage centrifugal pumps or combination of pumps in series / parellel of KSB / Mathur & Platt / Jyoti / Kirloskar / BE / Maxflow / Beaconweir Sabar make conforming to BIS 5659-1970) pump (Latest with upto to date ammendments, read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with bronze / Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling sliperring TEFC of electic induction motor/motor of standard make such as Kirloskar / NGEF / Cromption / Siemen / Jyoti / BHEL / GEC / ABB conforming to BIS 325-1978) read as BIS 900- 1972 and IS:12615:2011 with IE-2 specifications (latest upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the data given as below :- |
53 | DisCharge(Q) -19.20 LPS for each pump, Total Dynamic heads:- 126.31 Meter ,a) LWL in sump well(h)- 835.60 Meter ,b)Shaft Level - 835.00 Meter, c) Level at DisCharge point-955.80 Meter,d)Suction Lift -+ve, e) DisCharge Head- 120.80 Meter, f) Static head- 120.8Meter, Rising Main -a) Length - 740 Meter, b) Dia-200 mm, Pumping Hours- 20.00hrs, Altitude of installation above MSL - 830 Meter |
54 | Supply , Installation, Testing and Commissioning of Star Delta Starter panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 1 Nos. pumps (1working) of the suitable rating through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: JSV approved |
55 | Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination forsuitable starter. Make:- JSV Approved |
56 | Voltage Protection device to protect panel from over voltage and under voltage Make:- JSV Approved |
57 | Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage. |
58 | Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication.Make:- JSV Approved |
59 | Main incomer MCCB ofsuitable capacity of L&T / Schnieder/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 (Latest edition). |
60 | Individual Starter incomer MCCB/MCB ofsuitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition). |
61 | LED three phase indicating lamps complete with ogg d switches for individual motors confirming to BIS 3452 ( part ammendments) |
62 | LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc. |
63 | Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges. |
64 | Control Transformer to provide a stable control volatge to safegaurd the control circuit of all the components from the voltage surges and spikes. |
65 | Independent Control Panel with Switch Fuse Unit and Fuses of Suitable Amperage to eliminate the KItKat fuses of HPSEB Make: Siemens/Schnieder/L&T |
66 | Providing double flanged CI sluicevalve PN-1 of Leader/BHEL/ Kirlosker / GLED/Kilburn /Fourses /Kartarmake and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS:780:1984 with up to date ammendments) |
67 | Providing double flangedcast steel sluice valve, ASA-150 of Leader/ BHEL/Kirlosker/ Kilburn / GLEd/ Foursesmake and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
68 | Providing double flanged swing type cast steel reflux valve, ASA-150 of Leader/ BHEL/Kirlosker/ Kilburn / GLEd/ Foursesmake andhaving bye pass arrangements of one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
69 | Providing double flangedcast steel reflux valves class,ASA-150 of Leader/ BHEL/Kirlosker/ Kartar/ Kilburn / GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date ammendments) |
70 | Providing 100mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date ammendments. |
71 | Providing disCharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in Charge as per Is:2373:1981 with upto date ammendments. |
72 | Installation of all the items apparing as per the schematic drawing. |
73 | Providing and fixing double flanged MS/GI piping work (Layout to be approved by the Engineer in Charge) for suction and delivery pipes suitable to pump(s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with companions flanges matching with the relevant specifications of the accessoriesincluding rubber/asbestos gasket of minimum 3mm thckness as per IS:2712:1979 and required number of nuts and bolts as per Is:1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No.12. The size of the various components to be as under: |
74 | a) Suction pipe: One dia higher then the suction of pump offeredand suitable to keep thevelocity of flow from 1 to 1.5M/second in the suction pipe |
75 | b) Delivery pipe: One dia higher then the delivery of the pump offeredand suitable to keep thevelocity of flow from 1.5 to 2M/secondin the delivery pipe. |
76 | Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size andcapacity to motors and all other electircal equipments as per IS:1554 (P-I) 1988 or latest ith upto date ammendments of siemens/ GLOSTER / IEC/ ICC/ EICO/ NATIONAL/ GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor. |
77 | (a) Motor side 3 core (From switch to starter and starter to motor) |
78 | (b) Supply side (From Meter of HPSEB to bus bar and switch) complete in all respects as per the entire satisfaction of Engineer-in- Charge. |
79 | Providing and fixing double loop earthing with GIplate 600mmx600x3mm thick electrode completewith material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect. |
80 | Low Cost Automation (For 60 HP)- PLC (Programmable logic controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make JSV Approved complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
81 | Electronic relay card 8 channel complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
82 | SMPS 4.5 Amps to energise PLC system complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
83 | HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumpsMake:JSV Approved/Bechoff Automation/Rockwell complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
84 | Control MCB for Automation System complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
85 | Level Sensor to indicate the water level of tank remotely complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
86 | Shielded Data Cable for Communication of Level Sensor with PLC complete in all respect as per the entire satisfaction of Engineer-in- Charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy