Tender For Repair / Replacement And Maintenance Of Street And Solar Light Pole, Ug Cable Links, Feeder Pillar And Allied Works At Ins Sardar Patel And Naval Air Enclave Under Ge Navy Porbandar, porbandar-Gujarat

Military Engineer Services-MES has published Tender For Repair / Replacement And Maintenance Of Street And Solar Light Pole, Ug Cable Links, Feeder Pillar And Allied Works At Ins Sardar Patel And Naval Air Enclave Under Ge Navy Porbandar. Submission Date for this Tender is 15-02-2024. Feeder Pillar Tenders in porbandar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

41713035
Corrigendum : Tender For Repair / Replacement And Maintenance Of Street And Solar Light Pole, Ug Cable Links, Feeder Pillar And Allied Works At Ins Sardar Patel And Naval Air Enclave Under Ge Navy Porbandar
Open Tender
Indian
Gujarat
porbandar
15-02-2024

Tender Details

Repair / Replacement And Maintenance Of Street And Solar Light Pole, Ug Cable Links, Feeder Pillar And Allied Works At Ins Sardar Patel And Naval Air Enclave Under Ge Navy Porbandar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jan-2024 Corrigendum BOQ 08-02-2024
2 08-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR / REPLACEMENT AND MAINTENANCE OF STREET AND SOLAR LIGHT POLE, UG CABLE LINKS, FEEDER PILLAR AND ALLIED WORKS AT INS SARDAR PATEL AND NAVAL AIR ENCLAVE UNDER GE NAVY PORBANDAR
Sl. No. Item Description
1Taking down unservisable U/G cable from trenches, wall, floor etcupto 25 sqmm
2Taking down unservisableU/G cable from trenches, wall, floor etcabove 35 opto 120 sqmm
3S& F XLPE insulated armoured and pvc sheated heavy duty electric cable , aluminium conductor 1100 volt grade as per IS 7098 (Part-1) 1988 with latest amendmentlaid in tranches passing through pipes /ducts including testing complete for following size : Note - rate is inclusive of cable gland & cable lugs.
42 core 6 Sqmm cross sectional area
52 core 10 Sqmm cross sectional area
62 core 16 Sqmm cross sectional area
72 core 25 Sqmm cross sectional area
84 core 10 Sqmm cross sectional area
94 core 16 Sqmm cross sectional area
103-1/2 core 25 Sqmm cross sectional area
113-1/2 core 35 Sqmm cross sectional area
123-1/2 core 50 Sqmm cross sectional area
133-1/2 core 70 Sqmm cross sectional area
143-1/2 core 95 Sqmm cross sectional area
153-1/2 core 120 Sqmm cross sectional area
163-1/2 core 150 Sqmm cross sectional area
173-1/2 core 185 Sqmm cross sectional area
183-1/2 core 240 Sqmm cross sectional area
19Excavation intrenches in hard /densesoil not exceeding 1.5 mtrdeep and not exceeding 1.5 mtrwide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
20Returning, filling in including spreading, leveling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
21Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
22S& F in replacement oflaying of Double Walled Corrugated(DWC) HDPE pipe of following size of conforming to IS 16205 Part -24including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge.
2340/32 mm outer/inner dia
2450/38 mm outer/inner dia
2563/50 mm outer/inner dia
2675/63 mm outer/inner dia
2790/75 mm outer/inner dia
28110/95 mm outer/inner dia
29M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe all as directed.
30M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed.
31Supply & fix Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 50 mm dia along with necessarycalmp nut bolt etc complete allas specified and directed.
32Supply & fixSteel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessarycalmp nut bolt etc complete allas specified and directed.
33Taking down of faulty LT under ground cable of size upto 3.5x25sqmm from trenches /pole/wall etc for detecting fault including repair andjointing at site including relaying at the same location complete.Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
34Taking down of faulty LT under ground cable of size above 3.5x25sqmm up to150 sqmmfrom trenches /pole/wall etc for detecting fault including repair andjointing at site including relaying at the same location complete. Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
35Supply & Joint cable jointing kit heat shrinkable 1.1KV XPLE straight through jointof size 10 sqmm 4core to 16 sqmm 4 core cable size complete.
36Supply & Joint cable jointing kitheat shrinkable 1.1KV XPLE straight through jointof size 25 sqmm 3.5 core to 50 sqmm 3.5 core cable size complete.
37Supply & Joint cable jointing kit heat shrinkable 1.1KV XPLE straight through joint of size 70 to 150 sqmm 3.5 core cable size complete.
38Relaying dismentaled Brick covering perpendicular to axis of cable as a mechanical protection to cable complete all as specified and as directed.
39M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth strip 32x6mm size by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No. 2 of SSRPart-I all as specified and directed.
40Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete.
41S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
42Dismantling of existing U/S HT/LT poleof any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demolation of concrete, disconnection of conductor fom pole etc. complete all as directed.
43supply and install steel, tubular swaged poles complete with cast iron base plate, nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long).
44M& L Plain cement concrete 1:4:8type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
45M & L for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole complete all as specified and directed.
46Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site all as directed & specfied at site
47Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 40 cm above floor mounted ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
48(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f)Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:-(a) MCCB 250 A TPN 25 KA (LEGRAND- 4202 19) -01 No (b) Onload Manual Change Over Switch Open execution type 250 A ,4 Pole (L &T Model No- CO32500OOOO) -01 No (c) MCCB 160 A TP 25 KA (LEGRAND- 4200 47) -01 No (d) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -01 (e) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -02 No (f) DOL Starter with push button 5 HP ,415 V (Havells- IHPDOLK1 )-2 Nos(g) All out going LTfeeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
49Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
50(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 57) -01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:-(a) MCCB 100A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 45) -01 Nos(b) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos(b) All out going LTfeeders name with radium stickers -05 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
51Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
52(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a) MCCB 100A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 45) -02 Nos (b) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos(c) All out going LTfeeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
53Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
54(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100A TPN 25 kA with thermal magnetic release( Legrand Cat No 4200 55) -01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos , (b) MCCB 40 A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 42) -01 Nos (c) All out going LTfeeders name with radium stickers -05 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
55Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
56(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 55) -01 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a)MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos, (b) MCCB 40 A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 42) -02 Nos (d) All out going LTfeeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
57Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 100 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 30 cm above and 30 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
58(A) Incoming:- (a) Copper bus bar TPN 100 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 55) -01 Nos(g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a)MCB 63A TP ( Legrand Cat No 4086 61) -04 Nos(b) All out going LTfeeders name with radium stickers -04 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
59Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor typefloor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with airinsulated PVC sleeved Copper bus bar of rating 500 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, includingNeoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 45 cm above and 45 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glandsand PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
60(A) Incoming:- (a) Copper bus bar TPN 500 Amps - 01 Set (b) Voltmeter 3 phaseclass .5(L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter3 phaseclass1(L &T Model No-WL132020OOOO ) -01 Nos(d) Phase indicating lamp R, Y, B LED(L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 500X5 - 3 Nos (f) MCCB 630 A TPN 36 kA with thermal magnetic release ( Legrand Cat No 4220 09) -02 Nos (g)Danger notice plate/ sticker of suitable size on front panel board -01 No(B) Outgoing:- (a)Onload Manual Change Over Switch Open execution type 630 A ,4 Pole (L &T Model No- CO463000OOOO) -01 No (c) All out going LTfeeders name with radium stickers -02 NosNote:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
61S& F in replacement ofMCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
62S& F in replacement ofMCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
63S& F in replacement ofMCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
64S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
65S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
66S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
67Taking down partly unserviceable / unserviceable street / security light fittings from pole / tower/wall/hanger for necessary repaire toAGE E/M office and make serviceable in Store of office and note down the items required in the register as per complaints given by dept. through job card / complaint register on day to day basis & all as specified and directed by Engr-in Charge.
68Fixing only repaired serviceable street / security light fitting in the yard of AGE E/M NRC of any size & any make on pole / tower /wall of the Hanger of 20 meter height/ Water Tank at 25 Meter height/on bldg of any heightetc. complete. Note:- No ladder/T &P will be provided for fixing street light on pole/ wall/ hanger.
69Supply & fix in repare digital time switches - Multifunctional digital time switches of Make- Legrand/L&T/SIEMENS
70Supply & fix Power contactor ML-3, 3 pole rating not less than 40 A 230 coil Make : L&T / Siemens
71Supply & fix in replacement ofLed outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 Watt . Make:-As suitable in LED fittings of existing make
72Supply & fix in replacement ofLed outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 -100 Watt . Make:-As suitable in LED fittings of existing make
73Supply & fix in replacement ofLed outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 100-150 Watt . Make:-As suitable in LED fittings of existing make
74Supply & fix in replacement of Surge protection device ofRATING 5KVsuitable for LED street light /LED flood light fititngs of capacity upto 75 Watt . Make:-As suitable in LED fittings of existing make
75Supply & fix in replacement of Surge protection device ofRATING 5KVsuitable for LED street light /LED flood light fititngs of capacity upto above 75 Watt & upto 150WMake:-As suitable in LED fittings of existing make
76Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light fromjunction boxto streetlight fititng including making necessaey hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting as specified & directed. etccomplete all as specified and directed. Make:- Polycab/Havells/Gloster
77Supply & fix PVC junction box of size inside dimenssion 250x200x100 mm complete with industrial connector, including clamp made out of MS flat iron 30x5 mm, nut, bolts, washer ,glands etc, MCB 6-10Amps complete allas specified & directed.
78M & L for Preparation of surface of LT pole i.e. scrapping by brushes, emery paper, caustic soda etc of LT pole 9m/11m long with all connected channel, cross arms caps etc painting one coat of aluminium paint over a coat of anti rusted paint as a primer on steel surfaces and One coat of primer and two coat ofexterior acrylic emulsion paint (wheather coat) on Concrete surfaces including numbering by using white paint over a surface of black paint base of size 15cm x 15cm complete all as specified and as directed by Engineer-in-Charge. Note :-Manpower will be provided by contractor per pole per tradesman for scraping of pole for one shut down & for outer rust painting for pole for second shut down the period will only one hour per shut down in various period and timing and day which will be framed by the department.
79Taking down the High Mast light of any heightincluding bracket by the means of crane and reinstallation to site after servicing, greasing of pulley ,chain, repalcement of rusted nut boltsto have smooth functioning of wire rope mechanismwith help of high-capacity Hydraulic crane.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail