| 1 | Dismentling of ACSR condutor from pole627 LR |
| 2 | Dismentling ofG.I. wire from pole 628 LR |
| 3 | Reflexing of ACSR condutor on pole 627 LR |
| 4 | Reflexing ofG.I. wire on pole628 LR |
| 5 | Supply & erection of overhead line with ACSR conductor on poles / service bracket including binding etc. complete inall respects.627 |
| 6 | Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect.628 |
| 7 | Supply & erection of \"D\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint . 623 |
| 8 | Supply & fixing of 100 mm x 110 mmshackle insulator /100 mm x 80 mm pin insulator including G.I. Bolts / spindlenuts etc. complete in all respect.621 |
| 9 | Supply & fixing of 230 mm x 32 mm x 1.5 mm galvanised steel strips including holes for shakcle insulators pins andbolts etc. complete in all respect. 622 |
| 10 | Supply & erection of hexagonal / cradle type gaused of G.I.wire no. 8 to 4 SWG including binding etc. complete in all respect. 629 |
| 11 | Supplyand burying safe earthing Electorde T-19 (HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25,terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12swg withHotDipGavanized up to 100 mirconfilled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitchboard , cost of 25 x 3 G.I. strip will be extra) Make:As approved in U.P.P.W.D. & C.P.R.I. Certified 725 A |
| 12 | Supply and fixing of one number 8 SWG G.I. wire in 15 mm. dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.721 |
| 13 | Supply & erection of stay set at 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator,19 mm 600 mm double screw tightener,7/3.5 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in allrespect631 |
| 14 | Supply & fixing steel tubular pole 9.50 Metre long designated 410 SP-38 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect.616 |
| 15 | Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 65 and aboveProtection complete in all respect.Cat AAA1424 |
| 16 | Supply and laying of aluminum conductor PVC insulator armoured, served sheathed cable 1100 grad at dept of 750mm below ground level over a cushion of 75mm thick and sand alround and protected with burnt bricks on sides and the top. On surface, the cable runs should be fixed on M.S. clamps etc. of suitable size as directed by Engineer-in-charge, complete in all respects. The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 16 Sq mm 4 core501 I |
| 17 | Supply and laying of aluminum conductor PVC insulator armoured, served sheathed cable 1100 grad at dept of 750mm below ground level over a cushion of 75mm thick and sand alround and protected with burnt bricks on sides and the top. On surface, the cable runs should be fixed on M.S. clamps etc. of suitable size as directed by Engineer-in-charge, complete in all respects. The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 185 Sq mm 3-1/2 core501 Q |
| 18 | Supply and laying of aluminum conductor PVC insulator armoured, served sheathed cable 1100 grad at dept of 750mm below ground level over a cushion of 75mm thick and sand alround and protected with burnt bricks on sides and the top. On surface, the cable runs should be fixed on M.S. clamps etc. of suitable size as directed by Engineer-in-charge, complete in all respects. The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 120 Sq mm 3-1/2 core501 O |
| 19 | Supply and laying of aluminum conductor PVC insulator armoured, served sheathed cable 1100 grad at dept of 750mm below ground level over a cushion of 75mm thick and sand alround and protected with burnt bricks on sides and the top. On surface, the cable runs should be fixed on M.S. clamps etc. of suitable size as directed by Engineer-in-charge, complete in all respects. The armoring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sq mm 3-1/2 core501 J |
| 20 | Supply and fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads insulated with tap and making connection etc. complete in all respect as per directionof E / I.120 Sq mm504 J |
| 21 | Supply and fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads insulated with tap and making connection etc. complete in all respect as per directionof E / I.95 Sq mm504 I |
| 22 | Supply and fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads insulated with tap and making connection etc. complete in all respect as per directionof E / I.185 Sq mm 504 L |
| 23 | Supply and fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads insulated with tap and making connection etc. complete in all respect as per directionof E / I.70 Sq mm504 H |
| 24 | S/F of 100 Dia G.I. PipeDSR 2022 14.13.3 |
| 25 | Cement Conceret with 4 Cm. (1.5\") Guage approved Stone Ballast, Approved coarse sand and cement in the proportion of 4:2:1 including Supply of all materials, Labour and T&P etc. Required for propeer completion of the work. 279 |
| 26 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. 634 |
| 27 | Supply and fixing of 63 Amp. 415 volts TPN metel clad rewirable type switch fuse unit on angie iron bracket complete in all respects. 316 B |
| 28 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve6 - 32 amps.Cat. A1002 A |
| 29 | Supply and fixing of 63 Amp 4 pole Isolator 1007 B |
| 30 | S/F of bunch conductor 3 x 120 sq mm + 1 x 95 sqmm + 1 x 16 sq mm etc UPPCL |
| 31 | S/F of DistributionUPPCL |
| 32 | Supply and Erracetion of factory fabricated and wired metal clad dust and vermin proof floor mounting M.S. channel Base with bottom and top cable entreis Electrical control panel with TNP MCCB’ s [ Four Pole 36 KA with thermal magnetic release] Switches Complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage current and other parameters [ KVA; P.F; KW etc] in each phase with touch type selector switches for different readings instrument fuses current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC\BMC support withdeteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes; compression glands and indicating lamp on incomingetc.The job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panle board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm\2mm. Cubicle type switch board shall be of cat A and B Only.Incoming.200Amp. MCCB –1No. Out going.100 Amp.MCCB -2 N0. Cat. B. Pannel Cubical Type.812 A |