Tender For Repair And Maintenance Of Summer Appliances With Connected Accessories Under Ge Saugor., saugor-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances With Connected Accessories Under Ge Saugor.. Submission Date for this Tender is 13-02-2024. AMC of Air Condition Tenders in saugor Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

41689424
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances With Connected Accessories Under Ge Saugor.
Open Tender
Indian
Madhya Pradesh
saugor
13-02-2024

Tender Details

Tender For Repair And Maintenance Of Summer Appliances With Connected Accessories Under Ge Saugor.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2024 Corrigendum No. 02 Other 06-02-2024
2 06-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINT OF SUMMER APPLIANCES WITH CONNECTED ACCESSORIES UNDER GE SAUGOR
Sl. No. Item Description
1AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER) Carry out day to day complaintrectification and periodical service maintenance as per manual recommendation at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube alongwith insulation pipe, drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, air filter, Swing motor, over load relay, PVC grill, PCB circuit board along with remote control, Condensor motor & fan blade , industrial metal plugtop and bottom, Plug nut, Suction pipe, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring ,etc., complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately as Supply only.(ii)If required shifting of Split /Window AC shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). AC Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day
2Supply only following items suitable for AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER):-
3Compressor suitable for window/Split AC of capacity 1.5 TonMake:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
4Compressor suitable for window/Split AC of capacity 2.0 Ton Make:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
5Compressor Suitable for Split ACof Capacity 3.0 TonMake:GODREJ/L&T/BLUE STAR/WHIRLPOOL/VOLTAS
6Capacitor of capacity 25 MFD
7Capacitor of capacity 30 MFD
8Capacitor of capacity 35/36 MFD
9Capacitor of capacity 40/45 MFD
10Capacitor of capacity 50 MFD
11Capacitor of capacity 55/60 MFD
12Capacitor of capacity 65 MFD
13Capacitor of capacity 30+2 MFD
14Capacitor of capacity 30+4 MFD
15Capacitor of capacity 35/36+2.5 MFD
16Capacitor of capacity 35/36+4 MFD
17Capacitor of capacity 35/36+6 MFD
18Capacitor of capacity 40/45+2.5 MFD
19Capacitor of capacity 40/45+4MFD
20Capacitor of capacity 40/45+6 MFD
21Capacitor of capacity 50+2.5 MFD
22Capacitor of capacity 50+4 MFD
23Capacitor of capacity 50+6 MFD
24Capacitor of capacity 55/60+2.5 MFD
25Capacitor of capacity 55/60+4 MFD
26Capacitor of capacity 55/60+6 MFD
27Cooling Coil suitable for 1.5 Ton Capacity Window AC
28Cooling Coil suitable for 2.0Ton Capacity Window AC
29Cooling Coil suitable for 1.5 Ton Capacity Split AC
30Cooling Coil suitable for 2.0 Ton Capacity Split AC
31Cooling Coil suitable for 3.0 Ton Capacity Split AC
32Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner as per existing sample
33Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner as per existing sample
34Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample
35Swing motor blades suitable for 2.0 Ton Capacity Split type Air Conditioner as per existing sample
36Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
37Swing motor blades suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample
38Over load relay suitable for 1.5/2.0 Ton Window type AC
39Over load relay suitable for 1.5/2.0 Ton Split type AC
40Over load relay suitable for 3.0 Ton Split type AC
41PVC Frontgril suitable for Window type AC of any Make suitable for 1.5/2.0Ton windowAC
42AC indoor blower motor fan suitable for 1.5 Ton Capacity Window type AC
43All as per Srl item No. 2.41 here in before butsuitable for 2.0 Ton Capacity Window type AC
44All as per Srl item No.2.41 here in before but suitable for1.5 Ton Split AC
45All as per Srl item No. 2.41 here in before but suitable for2.0 Ton Split AC
46All as per Srl item No. 2.41 here in before but suitable for3.0 Ton Split AC
47Blower motor fan blade suitable for 1.5/2.0 Windowtype AC
48Blower motor fan blade suitable for 1.5/2.0 Split type AC
49Blower motor fan blade suitable for 3.0 Split type AC
50Condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC
51Condenser motor with fan blade suitable for 2.0Ton capacity Window type AC
52Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC
53Condenser motor with fan blade suitable for 2.0 Ton capacity for Split type AC
54Condenser motor with fan blade suitable for 3.0 Ton capacity for Split type AC
55Thermostat switch with knob suitable for AC of any capacity.
56Air Filter Suitable for1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner
57Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner
58PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC
59PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 Ton capacity split type capacity Air Conditioner .
60PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Ton capacity inverter type Air Conditioner
61Metal top with bottomsuitable for 16 Amps Capacity1.5/2.0/3.0 Ton Capacity Air conditionerMake:Anchor/Havells/Philips/Polycab and as per site requirement.
62Suction/Drain out pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample
63Insulation of size 1/4, 3/8for Split AC complete as per existing sample
64Insulation of size 1/2 5/8for Split AC complete as per existing sample
65Rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioneras per existing sample
66Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample
67Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner
68Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner
69Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner
70AC indoor AC unit back plate suitable for 1.5/2./3.0 Ton capacity Air conditioner
71Power relay Contactor suitable for 1.5 Ton AC
72Power relay Contactor suitable for 2.0 Ton AC
73Power relay Contactor suitable for 3.0 Ton AC
74AC indoor Main board suitable for 1.5 Ton Capacity Air Conditioner
75Refrigerent Gas R-22
76Refrigerent Gas R-32 ( C)
77Refrigerent Gas R-134(a)
78NRV Suitable for Any Capacity& any Make Air conditioner
79Dry cell 1.5V suitable for Different type of remote as per sample
80M&L for preparation of new steel surfaces of any description over 10 cmwidth or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed.
81M&L for dismantling of indoor and outdoor unit and disconnect the electric and gas connection ,cleaning the internal and portion of split AC indoor and outdoor unit checking serviceability transport to new location and fixing the indoor and outdoor unit connect gas and electric connection testing and commissioning complete all as specified and directed arge. Note:- (i) Rate shall be deemed included for outdoor stand, copper tube alongwith insulation,cable as per site requirement any size any length.point wiring shall be measured separately. (ii) Rate shall be deemed included for M&L for making good the disturbed wall portion during installation/shifting of AC by using plaster of Paris material and finishing to match with the existing surface
82WATER COOLER Carry out day to day rectification any Make,any capacity ofWater Cooler complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, GI grill, , industrial metal plugtop and bottom, Suction pipe etc., complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately as Supply.(ii)If required shifting of Water cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).Water coolerMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day
83Supply only following items suitable forWATER COOLER:-
84Compressor suitable for 60/120 Water cooler capacity
85Compressor suitable for 40/80 Water cooler capacity
86Compressor suitable for 150/150 Water cooler capacity
87Compressor suitable for 40/40Water cooler capacity
88Compressor suitable for 150/180 Water cooler capacity
89Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
90Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
91Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
92Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
93Thermostat switch with knobsuitable for compressor of water cooler 150/180,60/120 and 40/80 capacity
94PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia . Make: Prayag/waterman/leader or equalvent
95Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacityas per sample Make: Waterman/Leader
96Air Filter Suitable forwater cooler 150/180,60/120 and 40/80 capacity
97Capillary tube of suitable length as per existing size for water cooler150/180,60/120 and 40/80 capacity
98PVC Drain out pipe as per sample
99PVC Flexible extension pipe 15 mm dia, Make Prayag/V Guard/Leader
100Cooling Coil suitable for 150/180,60/120 and 40/80 capacity Water Cooler
101Cooling coil Motor suitable for 150/180,60/120 and 40/80 capacity Water Cooler
102Cooling coil Motor fan blade suitable for 150/180,60/120 and 40/80 capacity Water Cooler
103Sheet metal enclosures with flush mounted type plug and socket with 240 V SP MCB 20 AmpsCapacity Make:ABB/Legrand/Havells
104M&L for water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition including replacement of Bolt,nut with washers and testing complete all as directed
105REFRIGERATOR Carry out day to day rectification any Make,any capacity ofRefrigerator complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Vegitable tray, Magnetic gasket, Freezer, PVC Plugtop and bottom, etc., complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of Refrigerator shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv).RefrigratorMechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day
106Supply only following items suitable forREFRIGERATOR:-
107Compressor suitable for 195to 210 Ltrs Capacity Refrigerator
108Compressor suitable for225 to 250 Ltrs Capacity Refrigerator
109Compressor suitable for 260to 310 Ltrs Capacity Refrigerator
110Magnetic door gasket suitable for 165to200 ltrs capacity Refrigerator as per sample
111Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door)
112Freezer suitable for165 to 200 ltrs capacity Refrigerator
113Freezersuitable for 286/310 Ltrs capacity Refigerator
114Relay current typeand over load protector suitable for compressor complete Make:Ranutrol/Voltas/LG
115Thermostat auto defrost type suitable for any make and any capacity Refrigerator
116Air Filter suitable for for any make and any capacity Refrigerator
117Capillary tube of suitable length as per existing size for refrigerator any make and any capacity
118Vegitable tray with Glass cover and bottle rack as per sample and suitable for refrigertator any type and any make
119PVC Stand for Refigerator capacity any make and any capacity as per sample
120PVC top 16 Amps Suitable for any capacity and any make Refrigerator as per sample
121PVC Nylon Roller as per sample
122Contensor Coil suitable for any model and capacity Refrigerator as per sample
123Evaporator Coil suitable for any model and capacity Refrigerator as per sample
124Expansion valve suitable for any model and capacity Refrigerator as per sample
125DEEP FREEZER Carry out day to day rectification any Make,any capacity ofDeep Freezer complaints at Area I & Area IIlike testing of gas leakegefrom line any Capacity, replacement of defective any capacity of capacitor/Condensor,any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay, Magnetic gasket,PVC Plugtop and bottom, Door Lock, MS Hings, Trolley Nylon roller alingwith bracket etc complete allas directed by the Engineer-in-ChargeNote:(i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of Deep Freezer shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Deep Freezer Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day
126Supply only following items suitable for DEEP FREEZER:-
127Compressor Suitable for 300 Ltrs Capacity Deep Freezer
128Compressor Suitable for 500 Ltrs Capacity Deep Freezer
129Relay current type and over load protector suitable for compressor
130Thermostat auto defrost type suitable for any make and any capacity Deep Freezer Make:Danfos/Ind Foss/Renutrol
131Drier filter complete set suitable for any make and any capacity Deep Freezer
132Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete
133Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity
134Starting relay suitable for310/320 ltrs capacity Deep freezer
135Condenser motor (Rotary fan) suitable for any type and any capacity deep freezerMake;AUE/Cool Blow/Universal
136Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer
137DESERT COOLER Carry out day to day rectification any Make,any capacity of Desrt Cooler Complaints at Area I & Area IIlike testing of desert cooler any Capacity, replacement of defectivecapacitor, selector switch., Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector, PVC Hose,woodnen wool with mesh, Bolt,nuts along with washers, Water pumpalongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of desert cooler shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Desert cooler Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II .(vi).Attending the complaints not less than min three complaints per day
138Supply only following items suitable for DESERT COOLER:-
139Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories Make- Khaitan/Cool Blow/CG/Bajaj
140Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hrMake:Indo/Summer Cool
141Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size
142PVC Flexible hose suitable for desert coolercooling system
143PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample
144Selector switch as per existing model& size and three varient speed control
145Bolt, nut with washers as per sample
146PVC Connector i.e (Elbow, Tee,4 way etc)
147Switch 5 Amps
148Indication lamp
149Front Panel as per existing size and model
150PVC swirtch box as per sample and size
151GI Chicken Mesh
152PVC Insulated copper conductor and PVC over all coverd cord cable copper conductor 3 core of size 2.5 Sqmm Make :Plaza/Havells/ Finolex
153M&L for Sub main wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2x2.5Sqmmand 1x2.5 Sqmm Warth wire PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches including taking down as specified and directed. complete all as specified and as directed .(Note :- PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.)
154Carry out day to day rectification any make, any capacity of Air Curtains complaints at Area I & Area IIlike testing of Air Curtain any Capacity, replacement of defectivecapacitor, , Indication lamp, 5 Amps switch , Fan blade, Fan Motor, PVC Connector,alongwith bracket, wiring etc complete allas directed by the Engineer-in-ChargeNote (i) .Replacement of Spares and fitting shall be measuredand paid separately.(ii)If required shifting of Air curtain shall be measured and paid separtely.(iii).Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department (iv). Air curtain Mechanic along with Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day.(v).Rate included with transport vehicle provided by the contractor to attending the complaints Area I&II
155M&L for mild steel frame work such as in cooler stand ,water tanks/ desert cooler stand and similar work con-forming to FE 290 Gde E-165 including mounting on wall with suitable size nut bolt and grouting and making good disturb surface including taking outold rusted mild steel desert cooler standcomplete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail