Supply Of Double Pigtail Biliary Stent, Biliary Stent Straight, Pancreatic Stent , Biliary Metal Stent, Oesophageal Metal Stent, , ( Sr Ph Code-293102 ) Double Pigtail Biliary Stent. Should Be Made Up Of Polyethylene With Teflon Coated . The Stent Should Be Available In The Sizes From 5 To 10 Fr And Length 3 To 18 Cm. Unit:No , ( Sr Ph Code 293101 ) Biliary Stent Straight. Should Be Made Up Of Polyethylene With Teflon Coated . The Stent Should Be Available In Sizes From 5 Fr To 11.5 Fr And Length 3 To 21 Cm. Unit: No , ( Sr Ph Code 293103 ) Pancreatic Stent Single Pigtail Made Up Of Polyethylene With Spiral Side Holes Ranging In Sizes From 4 To 10Fr And Length From 2 To 20 Cm Unit: No , ( Sr Ph Code 293112 ) Biliary Metal Stent-It Is A Fully Covered Removable Metal Stent Should Be Made Of Alloy Material To Allow Greater Flexibility And Use In Tortuous Anatomy. Stent Lengths 4 Or 6 Or 8Cm With Retrieval String. Removability Indication Up To 12 Months After Placement For The Fully Covered Stent And Should Be Reconstrainable Even After 80% Of Deployment. Unit:No Page 1 Of 8 Run Date / Time: 17 / 01 / 2024 11:46:11Stores / Southern Rly Tender Document , ( Sr Ph Code 293104 ) Pancreatic Stent Straight Should Be Made Up Of Polyethylene And Available In Sizes From 3 To 11.5 Fr And Length From 2 To 20 Cm Unit :No , ( Sr Ph Code 293114 ) Biliary Metal Stent-It Is A Uncovered Metal Stent Should Be Made Of Alloy Material To Allow Greater Flexibility And Use In Tortuous Anatomy, Should Have Dual Deployment Mechanism Of Thumb Wheel & Pull Grip. Stent Should Have 6Fr Tip And Lengths 6 Or 8 Or 10Cm. Should Be Reconstrainable Even After 80% Of Deployment. Unit:No , ( Sr Ph Code 293115 ) Biliary Metal Stent-10Cm. It Is A Uncovered Metal Stent Should Be Made Of Alloy Material To Allow Greater Flexibility And Use In Tortuous Anatomy. Should Have Elongated, Tapered Tip 8Fr ( 2.67Mm ) Catheter 30Fr ( 10Mm ) Lumen Stent. Unit: No , ( Sr Ph Code 293130 ) Oesophageal Metal Stent-Fully Covered Removable Stent Should Have A Coaxial Delivery System With 25-30 Mm Flare, 20-25 Mm Body And Lengths 10 Or 12 Or 15Cm. It Should Be Reconstrainable Even After 75% Deployment. Unit: No , ( Sr Ph Code 293131 ) Oesophageal Metal Stent-Partially Covered Stent Should Have 20-23 Mm Flare, 18-20 Mm Body And Lengths 10 Or 12 Or 15Cm. Unit: No
BOQ
| Sl. No. | Item Description |
| 1 | Double Pigtail Biliary Stent, Biliary Stent Straight, Pancreatic Stent , Biliary Metal Stent, Oesophageal Metal Stent, |
| 2 | ( SR PH CODE-293102 ) DOUBLE PIGTAIL BILIARY STENT. SHOULD BE MADE UP OFPOLYETHYLENE WITH TEFLON COATED . THE STENT SHOULD BE AVAILABLE IN THE SIZES FROM 5 TO10 FR AND LENGTH 3 TO 18 CM. Unit:NO |
| 3 | (SR PH CODE 293101) BILIARY STENT STRAIGHT. SHOULD BE MADE UP OFPOLYETHYLENE WITH TEFLON COATED . THE STENT SHOULD BE AVAILABLE IN SIZES FROM 5 FR TO11.5 FR AND LENGTH 3 TO 21 CM. Unit: NO |
| 4 | (SR PH CODE 293103) PANCREATIC STENT SINGLE PIGTAIL MADE UP OF POLYETHYLENEWITH SPIRAL SIDE HOLES RANGING IN SIZES FROM 4 TO 10FR AND LENGTH FROM 2 TO 20 CM Unit: NO |
| 5 | (SR PH CODE 293112) BILIARY METAL STENT-IT IS A FULLY COVERED REMOVABLE METALSTENT SHOULD BE MADE OF ALLOY MATERIAL TO ALLOW GREATER FLEXIBILITY AND USE INTORTUOUS ANATOMY. STENT LENGTHS 4 OR 6 OR 8CM WITH RETRIEVAL STRING. REMOVABILITYINDICATION UP TO 12 MONTHS AFTER PLACEMENT FOR THE FULLY COVERED STENT AND SHOULDBE RECONSTRAINABLE EVEN AFTER 80% OF DEPLOYMENT. Unit:NOPage 1 of 8 Run Date/Time: 17/01/2024 11:46:11STORES/SOUTHERN RLYTENDER DOCUMENT |
| 6 | (SR PH CODE 293104) PANCREATIC STENT STRAIGHT SHOULD BE MADE UP OFPOLYETHYLENE AND AVAILABLE IN SIZES FROM 3 TO 11.5 FR AND LENGTH FROM 2 TO 20 CM Unit :NO |
| 7 | (SR PH CODE 293114) BILIARY METAL STENT-IT IS A UNCOVERED METAL STENT SHOULDBE MADE OF ALLOY MATERIAL TO ALLOW GREATER FLEXIBILITY AND USE IN TORTUOUS ANATOMY,SHOULD HAVE DUAL DEPLOYMENT MECHANISM OF THUMB WHEEL & PULL GRIP. STENT SHOULDHAVE 6FR TIP AND LENGTHS 6 OR 8 OR 10CM. SHOULD BE RECONSTRAINABLE EVEN AFTER 80% OFDEPLOYMENT. Unit:NO |
| 8 | (SR PH CODE 293115) BILIARY METAL STENT-10CM. IT IS A UNCOVERED METAL STENTSHOULD BE MADE OF ALLOY MATERIAL TO ALLOW GREATER FLEXIBILITY AND USE IN TORTUOUSANATOMY. SHOULD HAVE ELONGATED, TAPERED TIP 8FR (2.67MM) CATHETER 30FR (10MM) LUMENSTENT. Unit: NO |
| 9 | (SR PH CODE 293130) OESOPHAGEAL METAL STENT-FULLY COVERED REMOVABLE STENTSHOULD HAVE A COAXIAL DELIVERY SYSTEM WITH 25-30 MM FLARE, 20-25 MM BODY AND LENGTHS 10OR 12 OR 15CM. IT SHOULD BE RECONSTRAINABLE EVEN AFTER 75% DEPLOYMENT. Unit: NO |
| 10 | (SR PH CODE 293131) OESOPHAGEAL METAL STENT-PARTIALLY COVERED STENTSHOULD HAVE 20-23 MM FLARE, 18-20 MM BODY AND LENGTHS 10 OR 12 OR 15CM. Unit: NO |