Tender For Provn Of Aluminium Door, Windows, Improvement To Electrical Wiring And Water Supply Pipe Lines Of Smqs And Internal Electrification Work At Bldg No T-695 Under Ge Af Srinagar., srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provn Of Aluminium Door, Windows, Improvement To Electrical Wiring And Water Supply Pipe Lines Of Smqs And Internal Electrification Work At Bldg No T-695 Under Ge Af Srinagar.. Submission Date for this Tender is 08-02-2024. Electrification Work Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41670071
Corrigendum : Tender For Provn Of Aluminium Door, Windows, Improvement To Electrical Wiring And Water Supply Pipe Lines Of Smqs And Internal Electrification Work At Bldg No T-695 Under Ge Af Srinagar.
Open Tender
Indian
Jammu And Kashmir
srinagar
08-02-2024

Tender Details

Provn Of Aluminium Door, Windows, Improvement To Electrical Wiring And Water Supply Pipe Lines Of Smqs And Internal Electrification Work At Bldg No T-695 Under Ge Af Srinagar.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jan-2024 Corrigendum No 2 Other 08-02-2024
2 29-Jan-2024 Corrigendum No 1 Date 08-02-2024
3 29-Jan-2024 Corrigendum No 1 BOQ 08-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: PROVN OF ALUMINIUM DOOR, WINDOWS, IMPROVEMENT TO ELECTRICAL WIRING AND WATER SUPPLY PIPE LINES OF SMQs AND INTERNAL ELECTRIFICATION WORK TO BLDG NO T-695 UNDER GE (AF) SRINAGAR.
Sl. No. Item Description
1Schedule "A" Part-I (Building Works)
2Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each, complete all as specified and directed. Note: The damaged portion of the tiles/rendering shall be made good with the same materials to mach with the adjacent surface without any extra cost.
3Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each, complete all as specified and directed. Note: The damaged portion of the tiles/rendering shall be made good with the same materials to mach with the adjacent surface without any extra cost.
4Taking down Shutters of any description exc 1.00 Sqm but n exc 2.00 Sqm each, complete all as specified and directed.
5M&L for Pressed steel frames made out mild steel sheet 1.25 mm thick, with size of frame 125mm x 60 mm for doors with one or more rebates including necessary fixing lugs, lock strike plates etc and applying a coat of red oxide primer including providing PCC 1:3:6 type C-0 (using 12.5 mm graded crushed stone aggregate) for back filling of chowkhats, complete all as specified and diredted.
6S&F35mm thick, Second class hardwood, Factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded,fitted with cut and mitred beds for securing glassetc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a), supplied and fitted to chowkats, complete all as specified and directed.
7S&F 35 mm thick, Second class hardwood, Factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, Complete all as specified and directed by Engineer-in-Charge.
8S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixing in opening, complete all as specified and directed.
9S&F 30mm thick (Style) Factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
10S&F 125 mm long Aluminium anodised, handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
11S &F for125mm long aluminum, anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed
12S&F for 100mm size butt hinges medium weight , cold rolled MS and fixed, complete all as specified and directed.
13Supply, fabricate & fix in position aluminium power coated (minimum thickness of power coating 50 mircon of approved colour) three track window (two shutters glazed & one shutters wire gauge) with frame, glazed with 4mm thick tinted glass and, wire guage with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining coleat for fixing in posotion, concealed type lock for all three shutter, PVC roller etc as specified blelow, complete all as specified and directed Note:- (a) Frame (top & side) section shall of size 92.00x31.75x1.50mm (Section No 20831). (b) Frame (bottom) section shall of size 92.00x31.75x1.50mm (Section No 20832). (c) Top & side Members of shutter Section shall be of size 18.00x40.00x1.55mm (Section No 20738). (d) Shutter interlock Section shall of size 18.00x40.00x1.45mm (Section No 20737). (e) Bottom Members of shutter Sectionshall be of size 18.00x40.00x1.55mm (Section No 20736). Section No given above are of make Jindal, Contractor may use similar section of other make as mention in CA.
14S&F Powder Coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and directed.
15S&F powder coated of any colour (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, side hung type without sashbars / Sliding windows, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 No.), hinges type B-21 100mm long (2 No.), suitable handle (1 No.), complete all as specified and directed.
16S&F 5.5 mm thick sheet glass, ordinary quality and glazing with oil putty / wooden beads and aluminium beading in square not exceeding 0.5 sqm in each pane, complete all as specified and directed.
17S&F Stainless steel wire cloth0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and directed.
18S&F5mm thick Figured Glass pin head type, n exc 0.5 Sqm, and glazing with oil putty,Complete all as specified and directed.
19S&F powder coated aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minium anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening,complete all as specified and directed.
20Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing debries from site, complete all as specified and directed.
21M&L for Brick work with sub class "B" (using old size bricks) straight or curved of on plan exceeding 6 mean radius built in CM 1.6, complete all as specified and directed.
22All as per Ser item No. 1.20 here in above but except bricks.
23Taking down cement plaster of any description on brick or stone masonary wall, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
24M&L for 10mm thick Rendering in CM 1:6 on fair faces of brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement, complete all as specified and directed.
25M&L for 15mm thick Rendering in CM 1:4 on fair faces of brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement, complete all as specified and directed.
26Preperation of new plastered surface of walls and applying two coats of distemper oil emulsion including thin layer of wall care putty and & one coat of primer, complete all as specified and directed.
27Preoeration of new surface of wall and applying two coats of snowcem over one coat of primer, complete all as specified and directed.
28M&L for complete removal of existing treatment of walls and applying thin layer of wall care putty and prepare the smooth surface with sand paper and applying two coats of distemper oil emulsion (OBD) paint on walls, complete all as specified and directed.
29M&L for Complete removal of existing treatment from brick walls or concrete surfaces including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or un lastered surfaces) and applying two coat of cement based paint over a coat of cement primer including preparation of surfaces on walls, complete all as specified and directed.
30Schedule "A" Part-II (Intermal Electrification Works)
31Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces as per existingcomplete all as specified and directed.
32M & L for Point wiring for one light/fan/Exhausr fan controlled by one switch on Independent boardwith 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour code for phase and neutralas per IS code drawn through non metallic PVC rigidconcealed conduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thickand minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessories suitable formodular/conventionaltype fitment,provision for fixing of modular flush boxes of appropriate size and dimensionsfor fixing ofpiano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earthlead wire connected to common earth and earth dollycomplete all as specified and directed by Engr-in-Charge. Note: (i) For concealed point wiring cutting chases for conduit shall be measured and paid seperately (ii) For sinking boxes cutting chases for conduit shall be measured and paid seperately
33All as per Ser Item No 2.02 here in above but for One bell /Buzzer point controlled by one way switch.
34All as per Ser item No 2.02 here in above but for 05 amp socket outlets point controlled by one switch on Independent board.
35All as per Ser item No 2.02 here in above but for 05 amp socket outlets point controlled by one switch on same board.
36All as per Ser item No 2.02 but for 15 amp socket outlets point controlled by one switch on Independent socket outletusing 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour codeforphase andneutral as per IS code drawn through non metallic PVC rigid surface conduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thickand minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc fixed concealedwith all accessories suitable formodular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensionsfor fixing ofpiano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continous earthlead wire connected to common earth and earth dollycomplete all as specified and directed by Engr-in-Charge.
37S&F Modular switch, 1 way 6 Amp, 230 volts ,1 Module, complete all as specified and directed.
38S&F Modular switch, 2 way 6 Amp, 230 volts ,1 Module, complete all as specified and directed.
39S&F Modular Switch 1 way 16/20 Amp, 230 volts, 1 Module, complete all as specified and directed.
40S&F Modular Socket6 Amp, 230 volts,2/3 Pin universal, 2 Module, complete all as specified and directed.
41S&F Modular Socket, 16 Amp, 230 volts,2/3 Pin combined, 2 Module, complete all as specified and directed.
42S&F Modular fan step regulator 100 watt 2 Module, complete all as specified and directed.
43S&F Modular Bell push 6 Amp, 230 volts, 1 way, 1 Module , complete all as specified and directed.
44S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed.
45S&Fbell electric AC, 230V, single phase ,ding dong type, complete all as specified and directed.
46M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed.
47All as per Ser item No. 2.16 here in above for exc 10 cm but not exc 20 cm girth, complete all as specified and directed.
48S&F Module cover plate with frame as per site requirement for following module:-
49(a) 3 Module
50(b) 4 Module
51(c) 6 Module
52(d) 8 Module
53S&F Modular metal Flush box as per site requirement for following module:-
54(a) 3 Module
55(b) 4 Module
56(c) 6 Module
57S&F energy efficient LEDintegrated batten type luminairessuitable for wall or ceiling mounting with built in LED Chip & integral LED driver 20 watt, Aluminiumchannel housing & Polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500 K or as directed,Luminaire efficacy not less 100 lm/W with all accessories, fixing arrangement internally pre-wired, making all connection using 1.5 sqmm copper conductor multistarnd PVC insulatedcable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting, complete all as specified and directed.
58S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt,220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistarnd PVC insulatedcable from ceiling rose to fitting drawn through PVC flexible conduit, complete all as specified and directed.
59S&F LED light fitting surface type 600x600mm, 35/36 watts, 220V AC including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated cable from ceiling rose to fitting drawn through PVC flexible conduit, complete all as specified and directed.
60S&F LED Bulk Headtype with high out put , 10 watt ,220 V AC,Color temperature 6500 K or as directed,Lumens 1000 lm with all accessories ,IP 65 protection dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser ,LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface/wall mountedwith driver holder including connecting up using 1.5 sqmm copper conductor multistarnd PVC insulatedcable of suitable size, complete all as specified and directed.
61M &L for Disconnecting all water and electric connections of geysers and taking down carefully installed storage type electric geysers of any capacity of any make/type/size (horizontal/vertical) lowering and place at site , examine the parts including preparing inventory for each geyser separately in presence of Engineer-in-Charge and cleaning andde-scaling of deposited material from inner tank, outer tank and heating elements by HCL or aqua clear pedilite solution,checking electrical connection forthermostat and indicator lamp, repair to minor leaking by soldering/brazing of the inner copper tankif noticed and andpainting of geyser of any capacityafter scraping, cleaning, knotting and stopping including preparation of surface of geyser and rubbing with emery paper for painting with one coat of duco paint by spray paintingof approved make first quality and re write MES No. on the body of geyser with black synthetic enamel paint (letters and figures 2cm high ) &reassembling andre-fixing ofgeyser in its original location including hoisting, connecting to water & electric connection and testing for proper functioning of geysers including earthing to the entire satisfaction of the Engineer-in-Charge
62S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and directed.
63Taking down carefully ceiling fan any type, sweep and make for overhauling including dismantling of blades frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts complete all as specified and directed.
64Hanging only ceiling fan (M.D. supply)including replacement of rubber real insulator,split pin,nut,bolt, washer and connecting up including provision of cable 3 core flexible from ceiling rose or connector to fan complete all as specified and as directed.
65M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and markingMES No. with black paint, complete all as specified and directed.
66S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor, complete all as specified and directed.
67Taking down carefully Exhaust fan 300mm sweep, or overhauling including dismantling of blades frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts complete all as specified and as directed by Engr-in-charge. complete all as specified and directed .
68Fixing only exhaust fan (M.D.supply) and connecting up including provision of cable 3 core flexible from ceiling rose or connector to fan complete all as specified and as directed.
69S&F of Exhaust fan 300mm sweep, made of sturdy Engineering plastic complete with louvers shutter,voltage 230V, 50 Hz, RPM 1200, copper winding, includuing connection 1.5sqmm mutistrand copper conductor fiexible wire from ceiling rose, including oustsied louvers with proper hole, and necessary fixing arrangement and making good to disturbed surface, complete all as specified and directed .
70S&F LED Street Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt,PF-0.95 minimum, IP66 protection, 5700CCT(K),CRI between 80-85,confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012,for estimated life span ofminimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution,weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and directed.
71S&F bracket made out of GI, light grade, pipe of size 40 mm dia 1.5 m long bend to an angle of 120 degree with 02 Nos MS clamp 50 mm x 50 mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer, complete all as specified and directed.
72S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed.
73S&F Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size 200 amps bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed.
74S&F MCB single poles, 240V, 10 KA "B" curve and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissionincomplete all as specified and directed.
75S&F MCB single poles and neutral, 240V, 10 KA "B" curve and current carrying capacity32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
76S&F MCB single poles and neutral, 240V, 10 KA "B" curve and current carrying capacity40-63 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
77M & L for distribution board (DB), double door type, as per IEC 61439-3 made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCB DB, TPN 4 way with 200 Amps rated copper busbar, 415 Volts with in built MCCB 125 Amps, 16KA, 2 neutral bar and 2 earth bar IP 54 protection,cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall, complete all as specified and directed.Note : Rates are inclusive for flush(Concealed) mounting of DB and MCCB 125Amp TPN is included under respected items.
78S&F MCCB TPN, 440V, 25 KA "B" curve and current capacity 100 Amp, complete with connection testing and commissiong, complete all as specified and directed.
79Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includesmain earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
80M&L for Sub main wiring usingPVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded coppercable confirming to IS:694(2010) using approved colour code for phase and neutralas per IS code drawn through non metallic PVC rigidconduitheavy mechanical stress (HMS) grade inaccordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and external dia as underbut shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessoriescomplete all asspecified and as directed by Engr-in-chargeof the following sizes of cables as under .
81(a) Using two single corePVC insulatedFRLSH cable 4.0 sqmm copper conductor multi stranded ( Phase and neutral) and4.0 sqmm copper conductor PVC insulatedFRLSHcable as earth wiredrawing in and including concealed PVC conduitnot less than 2.00 mm thick , 25 mm outer dia(ISI marked)with all accessories Note :2 runs of 4.0 sqmm copper cable & 1 run of 4.0 sqmm copper cable and including 25mm PVC conduit shall be measured as one unit
82(b) Using two single corePVC insulatedFRLSH cable 6 sqmm copper conductor multi stranded ( Phase and neutral) and6 sqmm copper conductor PVC insulatedFRLSHcable as earth wiredrawing in and including concealed PVC conduitnot less than 2.00 mm thick ,25 mm outer dia(ISI marked)with all accessories Note :2 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable and including 25mm PVC conduit shall be measured as one unit
83S&F ultra moderen designed architectural LED luminaire which provides soft light and glaire free symmetrical illumination suitable for Armstrong/Grid Ceiling of size (595x595x65)mm 2"x2," complete all as specified and directed by Engr-in-Charge..
84Schedule "A" Part-III (External Water Supply Works)
85Excavation in trenches in soft loose soil n.exc 1.5m wide & n.exc 1.5m in depth and n. exc.10sqm on plan for laying pipe in trenches and getting out, complete allas specified and directed.
86Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in soft loose soil, complete all as specified and directed.
87Removing of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point, complete all as specified and directed.
88Taking out unserviceable/defective/damaged/blockage GI pipe 25mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. Note: Exacavation and earhwork shall be measured and paid for separately.
89Taking out unserviceable/defective/damaged/blockage GI pipe 50mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. Note: Exacavation and earhwork shall be measured and paid for separately.
90S&F 25mm bore GI tubing, medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends , elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing, complete all as specified and directed.
91S&F 50mm bore GI tubing, medium grade, ISI Marked conforming to IS 1239 Part-I 2004, including all fittings such as bends , elbows, tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing, complete all as specified and directed.
92Fixing only serviceable25mm bore steel water tubing and including new fitting conforming to IS 1239 Part-II: 2011 such as bends , elbows,tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed .(Old serviceable pipe obtained from taking downshall be used)
93Fixing only serviceable50 mm bore steel water tubing and including new fitting conforming to IS 1239 Part-II: 2011 such as bends , elbows,tees, short length , socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed .(Old serviceable pipe obtained from taking downshall be used)
94M &L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades , shelves, inlets, etc and cutting chases for concealed water tubing or concealed conduit wiring etc making good cutting not exc 10 cm girth, complete all as specified and directed by Engr-in-charge.
95S&Fgun metal/bronze gate valve for 25mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed.
96S&F gun metal/bronze gate valve for 50mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, complete all as specified and directed.
97M &L for provn of new valve chamber including necessary earth work in any type of soil, PCC 1:3:6 in bed concrete ,brick work in CM 1:6 with 10 mm thick plaster internally & 15 mm thick externally in CM 1:4, 3mm thick MS cover with himges and locking arrangement fixed to angle iron frame made out of 50mmx50mmx6mm MS angle complete with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on all metal works and applying two coats of white wash on all plastered surfaces, complete all as specified and drected.
98Deduction to be made from BOQ for Schedule "A" Part-IV (Credit Schedule from dismentling/taking down items) worth Rs 1,00,826.00 during AOC. Note :- Tenderers shall not quote for this Schedule.