Power Development Department has published Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Un. Submission Date for this Tender is 06-02-2024. Electrification Work Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSSJandrariStage Zero. |
2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
3 | GI V Cross -arm with top Bracket including clamps |
4 | GI Channel X-arm including clamps and Angle for braces |
5 | 30mm² ACSR Weasel Conductor |
6 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
7 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
8 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
9 | Galvanized Nuts and Bolts |
10 | Danger Plates with Clamps |
11 | Anti climbing device with clamps |
12 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
13 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
14 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
15 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
16 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 250 KVA Sub stn. at WSS JandrariStage Zero. |
17 | 11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 CopperWound, & with LV Cable box having detachable Aluminium Gland plate |
18 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
19 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
20 | 11 KV Horn gap fuse set 3 phase 200 A |
21 | 300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
22 | 9 mtr. Long ST pole (ST-410 SP33) |
23 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
24 | GI Channel /Angle/flat of sizes including clamps |
25 | Galvanized Nuts and Bolts. |
26 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
27 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
28 | LT Distribution box for 250 KVA DTR with MCCB for incormer and SFU"s for outgoing circuits box for |
29 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
30 | PG Clamps |
31 | Danger Plates with Clamps |
32 | GI Barbed wire for Anticlimbing |
33 | 3-phase HT Trivector meter with CT PT Unit |
34 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
35 | Painting of ST poles 9 mtr. long with 2 coat of Al. paint |
36 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJandrariStage Zero. |
37 | 8 mtr. Long ST poles (ST-410 SP15) |
38 | GI M Clamps for shackle insulator |
39 | 50mm²ACSR Rabbit Conductor |
40 | Shackle insulator |
41 | Galvanized Nuts and Bolts. |
42 | Danger Plates with Clamps |
43 | Anti climbing device with clamps |
44 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
45 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
46 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
47 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
48 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS JandrariStage First. |
49 | 9 mtr. Long ST Pole (ST-410 SP-33) |
50 | GI V Cross -arm with top Bracket including clamps |
51 | GI Channel X-arm including clamps and Angle for braces |
52 | 30mm² ACSR Weasel Conductor |
53 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
54 | PG Clamps |
55 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
56 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting |
57 | Galvanized Nuts and Bolts |
58 | Danger Plates with Clamps |
59 | Anti climbing device with clamps |
60 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
61 | Painting of 9 mtr ST poles with two coats of Aluminiumpaint. |
62 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
63 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
64 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 250 KVA Sub stn. at WSS Jandrari Stage First. |
65 | 11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 CopperWound, & with LV Cable box having detachable Aluminium Gland plate |
66 | Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
67 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
68 | 11 KV Horn gap fuse set 3 phase 200 A |
69 | 300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
70 | 9 mtr. Long ST pole (ST-410 SP33) |
71 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting |
72 | GI Channel /Angle/flat of sizes including clamps |
73 | Galvanized Nuts and Bolts. |
74 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
75 | 11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
76 | LT Distribution box for 250 KVA DTR with MCCB for incormer and SFU"s for outgoing circuits box for |
77 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
78 | PG Clamps |
79 | Danger Plates with Clamps |
80 | GI Barbed wire for Anticlimbing |
81 | 3-phase HT Trivector meter with CT PT Unit |
82 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
83 | Painting of ST poles 9 mtr. long with 2 coat of Al. paint |
84 | Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS JandrariStage First. |
85 | 8 mtr. Long ST poles (ST-410 SP15) |
86 | GI M Clamps for shackle insulator |
87 | 50mm²ACSR Rabbit Conductor |
88 | Shackle insulator |
89 | Galvanized Nuts and Bolts. |
90 | Danger Plates with Clamps |
91 | Anti climbing device with clamps |
92 | Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip |
93 | Painting of 8 mtr ST poles with two coat of Aluminium Paint |
94 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
95 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |