Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Un, Udhampur-Jammu And Kashmir

Power Development Department has published Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Un. Submission Date for this Tender is 06-02-2024. Electrification Work Tenders in Udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

41666983
Tender For Survey,Supply, Transportation, Carriage, Erection,Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Un
Open Tender
Indian
Jammu And Kashmir
Udhampur
06-02-2024

Tender Details

Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 2X250 Kva Sub Station Alongwith Erection Of 11 Kv Line On 9 Mtr. Longst Poles, 30Mm Sqacsrweasel Conductor & Lt Line On 8 Mtr. St Poleat Wss Jandrari Under Jjm On Turnkey Basis- 1 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wssjandraristage Zero. 2 9 Mtr. Long St Pole ( St-410 Sp-33 ) 3 Gi V Cross -Arm With Top Bracket Including Clamps 4 Gi Channel X-Arm Including Clamps And Angle For Braces 5 30Mm² Acsr Weasel Conductor 6 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 7 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 8 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 9 Galvanized Nuts And Bolts 10 Danger Plates With Clamps 11 Anti Climbing Device With Clamps 12 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 13 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 14 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 15 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 16 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 250 Kva Sub Stn. At Wss Jandraristage Zero. 17 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 18 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 19 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 20 11 Kv Horn Gap Fuse Set 3 Phase 200 A 21 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 22 9 Mtr. Long St Pole ( St-410 Sp33 ) 23 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 24 Gi Channel / Angle / Flat Of Sizes Including Clamps 25 Galvanized Nuts And Bolts. 26 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 27 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 28 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits Box For 29 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 30 Pg Clamps 31 Danger Plates With Clamps 32 Gi Barbed Wire For Anticlimbing 33 3-Phase Ht Trivector Meter With Ct Pt Unit 34 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 35 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 36 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wssjandraristage Zero. 37 8 Mtr. Long St Poles ( St-410 Sp15 ) 38 Gi M Clamps For Shackle Insulator 39 50Mm²acsr Rabbit Conductor 40 Shackle Insulator 41 Galvanized Nuts And Bolts. 42 Danger Plates With Clamps 43 Anti Climbing Device With Clamps 44 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 45 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 46 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 47 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 48 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 11 Kv Line On 9 Mtr. Long St Poles, 30Mm² Acsr Conductor At Wss Jandraristage First. 49 9 Mtr. Long St Pole ( St-410 Sp-33 ) 50 Gi V Cross -Arm With Top Bracket Including Clamps 51 Gi Channel X-Arm Including Clamps And Angle For Braces 52 30Mm² Acsr Weasel Conductor 53 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 54 Pg Clamps 55 11 Kv Polymer Composite Pin Insulator 12 Kv, 5 Kn, Lighting Impulse 75 Kv Positive And 80 Kv Negative, Creepage Distance 320Mm. 56 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Kvpositive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 57 Galvanized Nuts And Bolts 58 Danger Plates With Clamps 59 Anti Climbing Device With Clamps 60 Earthing Complete Bygi Rod 20 Mm, 2.5 Mtr Long Through G.I. Strip 25X3 Mm 61 Painting Of 9 Mtr St Poles With Two Coats Of Aluminiumpaint. 62 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 63 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 64 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Creation Of 250 Kva Sub Stn. At Wss Jandrari Stage First. 65 11 / 0.433 Kv, 3-Phase Distribution Transformer 250 Kva With Bimetallic Terminal Connectors Energy Level-2 Copperwound, & With Lv Cable Box Having Detachable Aluminium Gland Plate 66 Gapless Surge Arrestor, 9 Kv, 10 Ka , La With Polymer Housing Stn. Type 67 11 Kv Go Ab Switch 3 Phase, 3 Pole, 200 Amp, Vertical 68 11 Kv Horn Gap Fuse Set 3 Phase 200 A 69 300Mm² 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 70 9 Mtr. Long St Pole ( St-410 Sp33 ) 71 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45 Kn, Lightening Impulse 75Positive And 80 Kv Negative, Creepage Distance 320Mm With Fitting 72 Gi Channel / Angle / Flat Of Sizes Including Clamps 73 Galvanized Nuts And Bolts. 74 Earthing Of Sub Stn. Excavation Of Earth Pit Of Dia 650Mm & Depth 3000Mm Installation Of Earthing Pipe Of 40Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr. Long As Per Is 1239. G.I Strip For Neutral Earthing Of Size 25Mmx3mmfor Connection Of Transforemr Body, Go Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts Refilled With Earth Enhancement Materials And Earth Chamber With Rcc Slab Cover 75 11 Kv Polymer Composite Pin Insualtor, 12 Kv, 5Kn Lightening Impulse 75 Kv Positve And 80 Kv Negative, Creepage Distance 320Mm 76 Lt Distribution Box For 250 Kva Dtr With Mccb For Incormer And SfuS For Outgoing Circuits Box For 77 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete 78 Pg Clamps 79 Danger Plates With Clamps 80 Gi Barbed Wire For Anticlimbing 81 3-Phase Ht Trivector Meter With Ct Pt Unit 82 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 83 Painting Of St Poles 9 Mtr. Long With 2 Coat Of Al. Paint 84 Survey, Supply, Transportation, Carriage, Erection, Testing And Commissioning For Erection Of 3 Phase 4 Wire Lt Line On 8 Mtr. St Poles At Wss Jandraristage First. 85 8 Mtr. Long St Poles ( St-410 Sp15 ) 86 Gi M Clamps For Shackle Insulator 87 50Mm²acsr Rabbit Conductor 88 Shackle Insulator 89 Galvanized Nuts And Bolts. 90 Danger Plates With Clamps 91 Anti Climbing Device With Clamps 92 Earthing Complete Bygi Rod 20Mm 2.5 Mtr. Long Through Gi Strip 93 Painting Of 8 Mtr St Poles With Two Coat Of Aluminium Paint 94 Cement Bottoming 1:2:4 Mix As Per Rec Standard 0.5 Cum Per Pole 95 Galvanised Stay Set With 50X8mm Stay Clamp, Guy Insulator ( 2Nos. ) , Anchor Plate ( 200X 200 X 6 Mm ) , Nut-Bolts, 2 Nos Turn-Buckles, 1.8M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Complete

Key Value

Document Fees
INR 1000 /-
EMD
INR 77100.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Survey,Supply, Transportation, Carriage, Erection,Testing and Commissioning for Creation of 2x250 KVA Sub station alongwith erection of 11 KV Line on 9 mtr. longST poles, 30mm SqACSRweasel conductor & LT line on 8 mtr. ST poleat WSS Jandrari under JJM on turnkey basis.
Sl. No. Item Description
1Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSSJandrariStage Zero.
29 mtr. Long ST Pole (ST-410 SP-33)
3GI V Cross -arm with top Bracket including clamps
4GI Channel X-arm including clamps and Angle for braces
530mm² ACSR Weasel Conductor
611 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
711 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
811 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting
9Galvanized Nuts and Bolts
10Danger Plates with Clamps
11Anti climbing device with clamps
12Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
13Painting of 9 mtr ST poles with two coats of Aluminiumpaint.
14Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
15Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
16Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 250 KVA Sub stn. at WSS JandrariStage Zero.
1711/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 CopperWound, & with LV Cable box having detachable Aluminium Gland plate
18Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
1911 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
2011 KV Horn gap fuse set 3 phase 200 A
21300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
229 mtr. Long ST pole (ST-410 SP33)
2311 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting
24GI Channel /Angle/flat of sizes including clamps
25Galvanized Nuts and Bolts.
26Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
2711 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
28LT Distribution box for 250 KVA DTR with MCCB for incormer and SFU"s for outgoing circuits box for
29Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
30PG Clamps
31Danger Plates with Clamps
32GI Barbed wire for Anticlimbing
333-phase HT Trivector meter with CT PT Unit
34Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
35Painting of ST poles 9 mtr. long with 2 coat of Al. paint
36Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSSJandrariStage Zero.
378 mtr. Long ST poles (ST-410 SP15)
38GI M Clamps for shackle insulator
3950mm²ACSR Rabbit Conductor
40Shackle insulator
41Galvanized Nuts and Bolts.
42Danger Plates with Clamps
43Anti climbing device with clamps
44Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip
45Painting of 8 mtr ST poles with two coat of Aluminium Paint
46Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
47Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
48Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. long ST poles, 30mm² ACSR Conductor at WSS JandrariStage First.
499 mtr. Long ST Pole (ST-410 SP-33)
50GI V Cross -arm with top Bracket including clamps
51GI Channel X-arm including clamps and Angle for braces
5230mm² ACSR Weasel Conductor
5311 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
54PG Clamps
5511 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
5611 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting
57Galvanized Nuts and Bolts
58Danger Plates with Clamps
59Anti climbing device with clamps
60Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
61Painting of 9 mtr ST poles with two coats of Aluminiumpaint.
62Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
63Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
64Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for creation of 250 KVA Sub stn. at WSS Jandrari Stage First.
6511/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 CopperWound, & with LV Cable box having detachable Aluminium Gland plate
66Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
6711 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
6811 KV Horn gap fuse set 3 phase 200 A
69300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
709 mtr. Long ST pole (ST-410 SP33)
7111 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75Positive and 80 KV Negative, creepage distance 320mm with fitting
72GI Channel /Angle/flat of sizes including clamps
73Galvanized Nuts and Bolts.
74Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
7511 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
76LT Distribution box for 250 KVA DTR with MCCB for incormer and SFU"s for outgoing circuits box for
77Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
78PG Clamps
79Danger Plates with Clamps
80GI Barbed wire for Anticlimbing
813-phase HT Trivector meter with CT PT Unit
82Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
83Painting of ST poles 9 mtr. long with 2 coat of Al. paint
84Survey,supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS JandrariStage First.
858 mtr. Long ST poles (ST-410 SP15)
86GI M Clamps for shackle insulator
8750mm²ACSR Rabbit Conductor
88Shackle insulator
89Galvanized Nuts and Bolts.
90Danger Plates with Clamps
91Anti climbing device with clamps
92Earthing complete byGI Rod 20mm 2.5 mtr. Long through GI Strip
93Painting of 8 mtr ST poles with two coat of Aluminium Paint
94Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
95Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete