Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #41655054

Tender For Purchase Of Spectro Photo Meter

Issued by Boards / Undertakings / PSU · palakkad, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Jan 2024
0 days left
EMD
5000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
palakkad → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Purchase Of Spectro Photo Meter Specification Details Given In Tender Notice , Uv-Vis Spectrophotometer Type -117Ts (190-1100Nm,1Nm B/W) ,Uv-Vis Spectrophotometer • Mode Of Operation: Instrument Can Operate Standalone And Pc Based • Wavelength: 190-1100Nm,Wavelength Accuracy : ± 0 .5 Nm, Wavelength Resolution: 0.1 Nm,Bandwidth : 1Nm, Absorbance Range: -0.040 To 4 Abs, Absorbance Accuracy: ± 0.005,Photometric Repeatability: ±0.002 Abs At 1 Abs, Display: 10 Inch With 1200 X 800 Resolution With Touch Screen, Sample Holder: 5 Position Automatic Sample Holder. • Stray Light: =0.1% T At 220 Nm And 340 Nm • Mode Of Operation: Single Wavelength, Multi Wavelength, Scan, Time Scan, Dna & Protein • Measuring Mode : %T, Abs, Concentration • Special Provision For Nitrate And Fluoride Analysis • Source:Tungsten Halogen Lamp And Deuterium • Inbuilt Smart Station With Windows 10 Or Higher Version • Printer :Support All Printerssupporting Windows 10 Or Higher Version • Connectivity :Usb, Bluetooth, Wifi • Memory: Min 128Gb • Software Should Have Audit Trial Functionality. • Accessories: 1 Pair Quartz Cuvette, Pc Controlling Software. • Oem Should Have Service Center In Kerala • Bidder Should Submitminimum 5 Users List In Kerala For The Quoted Model.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 23-Jan-2024 Tender Notice Other 27-Jan-2024

BOQ

Name of Work: Purchase Computer Accessories
Sl. No. Item Description
1UV-Vis SpectrophotometerType -117TS (190-1100nm,1nm B/W) ,UV-VIS Spectrophotometer • Mode of operation: Instrument can operate standalone and Pc based• Wavelength: 190-1100nm,Wavelength accuracy : ± 0 .5 nm, Wavelength resolution: 0.1 nm,Bandwidth : 1nm, Absorbance range: -0.040 to 4 Abs, Absorbance accuracy: ± 0.005,Photometric Repeatability: ±0.002 Abs at 1 Abs, Display: 10 inch With 1200 X 800 Resolution with touch screen, Sample holder: 5 position automatic sample holder.• Stray light: =0.1% T AT 220 nm and 340 nm• Mode of operation: single wavelength, Multi wavelength, Scan, Time scan, DNA & Protein• Measuring mode : %T, Abs, Concentration• Special provision for Nitrate and Fluoride analysis• Source:Tungsten halogen lamp and Deuterium• Inbuilt smart station with windows 10 or higher version• Printer :support all Printerssupporting windows 10 or higher version• Connectivity :USB, Bluetooth, WiFi• Memory: Min 128GB • Software should have audit trial functionality. • Accessories: 1 pair Quartz cuvette, PC controlling software.• OEM should have service center in Kerala• Bidder should submitminimum 5 users list in Kerala for the quoted model.

AI Tender Summary

OUR REF NO 41655054
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 27-01-2024
Authority
Authority Name NSS College of Engineering
Work Description Purchase Of Spectro Photo Meter Specification Details Given In Tender Notice , Uv-Vis Spectrophotometer Type -117Ts (190-1100Nm,1Nm B/W) ,Uv-Vis Spectrophotometer • Mode Of Operation: Instrument Can Operate Standalone And Pc Based • Wavelength: 190-1100Nm,Wavelength Accuracy : ± 0 .5 Nm, Wavelength Resolution: 0.1 Nm,Bandwidth : 1Nm, Absorbance Range: -0.040 To 4 Abs, Absorbance Accuracy: ± 0.005,Photometric Repeatability: ±0.002 Abs At 1 Abs, Display: 10 Inch With 1200 X 800 Resolution With Touch Screen, Sample Holder: 5 Position Automatic Sample Holder. • Stray Light: =0.1% T At 220 Nm And 340 Nm • Mode Of Operation: Single Wavelength, Multi Wavelength, Scan, Time Scan, Dna & Protein • Measuring Mode : %T, Abs, Concentration • Special Provision For Nitrate And Fluoride Analysis • Source:Tungsten Halogen Lamp And Deuterium • Inbuilt Smart Station With Windows 10 Or Higher Version • Printer :Support All Printerssupporting Windows 10 Or Higher Version • Connectivity :Usb, Bluetooth, Wifi • Memory: Min 128Gb • Software Should Have Audit Trial Functionality. • Accessories: 1 Pair Quartz Cuvette, Pc Controlling Software. • Oem Should Have Service Center In Kerala • Bidder Should Submitminimum 5 Users List In Kerala For The Quoted Model.
Basic Detail
Tender No A6/CE/SPM/2023-24/NSSCE
Bidding Type Tender
Location
City palakkad
State Kerala
Key Dates
Publish Date 23 Jan 2024
Submission Date 27 Jan 2024
Open Date 30 Jan 2024
Finance
Tender Value Ref. Documents
Tender Fee 590
EMD 5000
Exemption Not Available
Document List
Tendernotice_1.pdf
ae34ee04-52d1-4648-b087-55074c0bfe06.html
BOQ_984402.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 23, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 27, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 30, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

ae34ee04-52d1-4648-b087-55074c0bfe06.html

xls

BOQ_984402.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders