Textiles Statutory Bodies & Commissions/Committees Closing in 0 days TDR #41652907

Tender For Renovation Of Parking Area At Khadi Tower Kaloor In Ernakulam District

Issued by Statutory Bodies & Commissions/Committees · ernakulam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Jan 2024
0 days left
EMD
36000
Bank guarantee accepted
Document Fee
2400
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Renovation Of Parking Area At Khadi Tower Kaloor In Ernakulam District

BOQ

Name of Work:Renovation of Parking Area at Khadi Tower Kaloor in Ernakulam District
Sl. No. Item Description
1APPENDIX-A
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R2016 ,15.7.4 )
3Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - inChargeNominal concrete 1:4:8 or leaner mix (i/c equivalent design Mix) ( D S R2016 ,15.2.2. )
4Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(D S R2018,- 15.3 )
5Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(D S R 2016,15.56 )
6Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres leadOf area 3 sq. metres and below( D S R15.12.1.)
7Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm( D S R2016,15.23.1)
8Dismantling Aaluminium/Gypsum Partitions,doors, windows, Fixedglazing and False ceiling including disposal of unserviceable surplusmaterial and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (D SR 15.57)
9Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).( 2018D S R, 4.1.8.)
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).(D S R4.1.5)
11Providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc. ( Observed Data 50.4.1.1.)
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo - Mechanically Treated bars of Grade Fe 500 Dormore . ( 2018D S R,5.22A.6)
13Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)( 2018D S R , 5.2.2. )
14Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts. (2018D S R , 5.9.6. )
15Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.2.)
1612 mm cement plaster of mix :1:4 (1 cement: 4coarse sand)(D S R13.4.1.)
1712 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)D S R13.7.1 )
18Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4coursesand). ( D S R14.1.2)
19Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.( D S R10.2.)
20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(D S R9.48.2)
21Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1)
22Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work.( D S R13.61.1 . )
23Wall painting with plastic emulsion paint of approved brand and manufactureto give an even shade : One or more coats on old work(2018 D S R 13.98.1)
24Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. ( 2018D S R,13.99.1 )
25Engaging Labour For Cleaning works / Repair WorksBeldar(D S R0115)
26Engaging Labour For Cleaning works / Repair WorksMASON(D S R0115)
27Engaging Labour For Maintenance works / Repair WorksFitter /PlumberGr I(D S R0116)
28DismantlingExistingInterlockPavingTiles
29Engaging Labour For Maintenance works / Repair WorksCarpenter
30Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade ( OBSEVEDDATALSGD51.2.3)
31Providing and layingDepartmentalcement concrete Interlocking paver block , laid in requiredpattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge.
32Providing and laying 60mm thick faciory made cement concrete Interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sandetc. all complete as per the direction of Engineer-in-charge.( 2018D S R,16.68)
33Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster ( D S R2018 , 13.9.2. )
34Floor painting with floor enamel paint of approved brand andmanufacture of required colour to give an even shade : Two or more coats on new work ( D S R2018 13.66.1)
35Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigmentetc., complete. (DS R 2018,11.37 )
36Fixing chowkhats in existing opening including embedding chowkhats in floors or walls, cutting masonry for cement concrete blocks of size 15 x 10x 10 cm with cement concrete 1 : 3 : 6 ( 1 Cement :3 Course Sand : 6 Graded Stone Aggregate 20 mm nominal size ), Painting two coats of approved wood preservative to sides of Chowkhats and making good the damages to walls and floors as required complete, includingdisposal of the rubbish to the dumping ground within 50 m lead Door chowkhats( D S R 14.2.1.)
37Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. topslab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand), finished smooth with a floating coatof neat cement on walls and bed concrete etc. complete as perstandard design: Inside dimensions 610x610 mm and 45 cm deep for singlepipe line :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5( D S R19.30.2.1.)
38Disposal of building rubbish / malba / similar unserviceable, dismantledor waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or asapproved by Engineer-in-charge, beyond 50 m initial lead, For all leadsincluding all liftsinvolved. ( D S R201615.60)
39Cutting holes up to 30x30 cm in walls including making good thesame: With common burnt clay F.P.S. (non modular) bricks( D S R 2016 18.76.1 )
40Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required :W.C. pan with ISI marked white solid plastic seat and lid( DSR2016 17.2.1)
41Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550 X 400mm with a single 15 mm C.P. brass pillar tap. (D S R17.7.4. )
42Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.40 mm dia ( D S R17.28.2.2. )
43Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length, 15 mm nominal bore(D S R2018,18.21.2.1)
44Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore (DSR2018 18.51.1)
45Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved qualityconforming to IS: 893115 mm nominal bore(DSR201818.53.1)
46Providing and fixing PTMT bib cock of approved quality and colour15 mm nominal bore, 122mm long, weighing not less than 99 gms( D S R18.54.2)
47Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating(D S R 18.58.2.1.)
48Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge( ODBUILDINGS50.17.1.1)
49Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. (50.17.1.3OD Buildings).
50Supplying and fixing CP Health Faucet superior quality (Jaguar or equivalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. ( ODBUILDINGS 50.17.1.5.)
51Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 ( ODBUILDINGS 50.18.8.2.1)
52Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2( OD 50.18.9.9.1)
53Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2( OD50.18.9.9.2. )
54Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mmdia 6 Kgf/cm2 ( ODBUILDINGS50.18.9.10.1)
55Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 20 mm dia12Kgf/cm2 - External work - Exposed on wall(OD50.18.9.12.1)
56Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. Thisincludes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete asper direction of Engineer-in-Charge 50 mm dia10Kgf/cm2 - External work - Exposed on wall(OD50.18.9.16.1)
57Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall( OD BUILDINGS50.18.9.17.2)
58Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia6Kgf/cm2 - External work - Exposed on wall( ODBUILDINGS50.18.9.18.2)
59Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall( OD BUILDINGS 50.18.9.19.2)
60Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow( OD50.19.9.20.1 )
61Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow ( OD50.18.9.20.2. )
62Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow( OD50.18.9.20.3 )
63Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x63x63 mm dia Door Tee ( OD 50.18.9.20.6 )
64Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVCsolvent cement - 63 mm dia vent cowl(OD50.18.9.20.7 )
65Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow ( OD50.18.9.22.1 )
66Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia45digree Elbow ( OD50.18.9.22.2 )
67Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow(ODBUILDINGS50.18.9.22.3)
68Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend (ODBUILDINGS50.19.9.22.4)
69Providing and fixing PVC moulded fittings / accessoriesforRigidPVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee(OD BUILDINGS 50 .18.9.22.6)
70Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3)
71Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12)
72Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21)
73Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( D S RELECTRICAL1.21.1)
74Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25MM( D S RELECTRICAL1.21.2)
75Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1)
76Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3)
77Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4)
78Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 )
79Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26)
80Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1)
81Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)( D S RELECTRICAL1.27.2)
82Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6Module( D S RELECTRICAL1.27.4)
83Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12Module (200mmX150mm)(D S RELECTRICAL1.27.6)
84SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS (od15443/2021_2022)

AI Tender Summary

OUR REF NO 41652907
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 23-01-2024
Authority
Authority Name Kerala Khadi And Village Industries Board
Work Description Tender For Renovation Of Parking Area At Khadi Tower Kaloor In Ernakulam District
Basic Detail
Tender No KB5968/22/Engg
Bidding Type Tender
Location
City ernakulam
State Kerala
Key Dates
Publish Date 12 Jan 2024
Submission Date 23 Jan 2024
Open Date 25 Jan 2024
Finance
Tender Value Ref. Documents
Tender Fee 2400
EMD 36000
Exemption Not Available
Document List
40bf91d4-504a-42f6-a632-5239f3375cd3.html
BOQ_984921.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 12, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 23, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

40bf91d4-504a-42f6-a632-5239f3375cd3.html

xls

BOQ_984921.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders