Urban Development And Housing Department has published Tender For Infrastructure Development Of Govt. Sec. School At Ranglua. Submission Date for this Tender is 29-01-2024. Infrastructure Work Tenders in Longding Arunachal Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Academic cum Administrative Building |
2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
3 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
4 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
5 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
6 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
7 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
8 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
9 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
10 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement:1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
11 | Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
12 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
13 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
14 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
15 | e) Column, pillars, posts and struts etc. |
16 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars. |
17 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
18 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
19 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
20 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
21 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I |
22 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I |
23 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill. |
24 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm |
25 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. a) 300 x 10 mm |
26 | c) 150 x 10 mm |
27 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm |
28 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
29 | Polycarbonate sheet roofing [This versatile thermoplastic maintains its properties over a wide range of temperatures, from -40”F to 280”F. It has the highest impact resistance of any Thermoplastic, transparent up to 2” in special grades, outstanding dimensional and thermal stability, exceptional machinability, stain resistant and non-toxic while having low water absorption |
30 | Providing and fixing Durasr,ine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutling hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer"s specification, effective Measurable length wi be (4 x 3.05) - (3 Q..15) = 11.75m |
31 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
32 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood. |
33 | Extra for chamfered edges in beading |
34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. d) size of tiles 1000x1000mm |
35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete. d) size of tiles 1000x1000mm |
36 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
37 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
38 | Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes upto 6 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of :a) Light shades using white cement |
39 | Chequered terrazzo tile_s 22 mm lhick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: a) Light shades using white cement |
40 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
41 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
42 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
43 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
44 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade |
45 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade |
46 | Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand). |
47 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
48 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
49 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore |
50 | b) 20 mm nominal bore |
51 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 15 mm nominal bore |
52 | b) 20 mm nominal bore |
53 | d) 32 mm nominal bore |
54 | Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore |
55 | Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore |
56 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan |
57 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain inenamelledflushband,20mmoverflowpipewithspecialsandmosquitoproof coupling of approved municipal design complete including cutting and making good the walls and floors where required. a) WC pan with white plastic seat and lid. |
58 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality. |
59 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. a) 250 x 130 x 30 mm |
60 | Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete. |
61 | Providing and fixing 100 mm sand PVC grating for gulley, floors or nahni trap. |
62 | Providing and fixing sand UPVC/PVC (spun) soil, waste and vent pipes. a) 100 mm dia |
63 | c) 50 mm dia |
64 | Providing and fixing UPVC/PVC heel rest sanitary bend. a) 100 mm dia |
65 | Providing and fixing PVC single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm |
66 | Providing and fixing PVC trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet |
67 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: |
68 | ExternalElectrical service connection |
69 | Add Carriage Charges |
70 | Addinternal electrification |
71 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
72 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
73 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
74 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
75 | 2 X 4 sq. mm +1 X 4 sq. mm earth wire |
76 | 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
77 | 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
78 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
79 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
80 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
81 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
82 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
83 | 25 mm |
84 | 32 mm |
85 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
86 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
87 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
88 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
89 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
90 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as reqd. |
91 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm X 75mm) |
92 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
93 | Cat6 RJ45 socket outlet |
94 | Supply & fixing of telephone tag blocks with gas tight connecton with self- cleaning "KRONE" terminal connectors fixed in minimum 1.2mm thick powder coated, hinged, lockable door, sheet steel dust proof indoor enclosure including mounting frame and label holder including civil work such as chase cutting, fixing / concealing the box and making good as required including terminations: 10 pair tele tag block |
95 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
96 | 2 run of cable |
97 | 3 run of cable |
98 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
99 | DISTRIBUTION BOARDS: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 12 way (4 + 36), Double door |
100 | Supplying and fixing 5A to 32A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
101 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
102 | Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
103 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
104 | Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. For 12 way, Double door TPN MCBDB |
105 | Supplying and fixing of 160A Four Pole MCCB, 415 V, Breaking capacity of 16 kA (Ics= 100%Icu), Compact sized Din mountable, snap fitted Moulded Case Circuit Breaker (MCCB) with inbuilt adjustable Overload settings, conforming to IS/IEC: 60947-2 and IEC 60947-2, in the Enclosure complete with connections, testing and commissioning etc. as required. |
106 | SUPPLY OF LIGHT FIXTURES AND FANS: Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge. Supply of 20W 1200mm LED fitting batten light. |
107 | Supply of 12W round surface sleek LED fitting . |
108 | Supply of 1200mm dia ofceiling fan complete withdouble ball bearing, motor,blades,downrod,canopy,capacitoretc.suitableforoperationon 230 volt, 50 Hz, A.C. supply complete as required. |
109 | Supplying, installation and fixing of 250mm sweep energy saving PVC exhaust fans with low power consumption etc complete with base frame and mounting arrangement with lovers complete as required. |
110 | INSTALLATIONS OF LIGHT FIXTURES AND FANS: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
111 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
112 | Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc as required. |
113 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
114 | EARTHING SYSTEM: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
115 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
116 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
117 | FIRE DETECTION AND ALARM SYSTEM ( CONVENTIONAL) Supplying, installation, testing & commissioning ofsmoke detector with builtin LED and mounting base complete with all connections etc. as required. |
118 | Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
119 | Supplying, installation, testing & commissioning of response indicator on surface/recesss MS box having two LEDs metallic cover complete with all connections etc. as required. |
120 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
121 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 Zone |
122 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm |
123 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
124 | BUSBAR BOX BUBASR BOX-WALL MOUNTED Busbar 200Amp, 4P, 25kA, Aluminium busbars Outgoing 4 Nos. Holes in 3 phase and Neutral busbar with hardwares suitable for outgoing cable connections upto 4Cx16 Sqmm Al Arm Cable. BUBASR BOX-WALL MOUNTED as described above and shown in SLD. |
125 | Fire Fighting |
126 | Supplying andfixing first-aidHoseReelwithMS constructionspraypaintedinpostofficered, conformingtoIS884completewiththefollowingas required. 20mmnominalinternaldiawaterhosethermoplastic (Textile reinforced) type -2 as per IS: 12585 20mmnominalinternaldiagunmetalglobevalve& nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
127 | Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications. |
128 | Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications. |
129 | Under Ground Sump |
130 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t All kind of Soil |
131 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
132 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
133 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
134 | Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement: 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size). |
135 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
136 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
137 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
138 | Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. a) Cold twisted bar. |
139 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
140 | 15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall |
141 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade |
142 | Supplying and laying under layer of bitumen saturated felt type-I. |
143 | Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/and residual bitumen applied hot @ 1.45 Kg. per Sq.m. of area for each courses, second course of roofing felt type-3 grade-I (hessian base self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per sqm.including preparation of surface excluding grading complete. |
144 | Providing and Placing in position suitable PVC water stops conforming to IS:12200for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb ( 225mm wide, 8-11mm thick). |
145 | Supplying & Fixing CI Covers for manholes w/o frames, 560 mm dia (Heavy Duty), the weight of the cover to be not less then 108 kg. |
146 | Add Carriage Charges |
147 | Add Side Development |
148 | Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.) Girth from 300 mm to 600 mm |
149 | Clearing Grass and Removal of Rubbish 50 |
150 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.) |
151 | Excavation in ordinary rock by manual means (Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres ) |
152 | Add Septic Tank(150 User) |
153 | Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.0.00-1.50m |
154 | Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.1.50-3.00m |
155 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
156 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
157 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
158 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete. |
159 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick. |
160 | Edges of slabs and breaks in floors and walls. Under 20 cm wide |
161 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. |
162 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement :4 coarse sand) |
163 | 62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
164 | Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement. 20mm cement plaster |
165 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450 mm internal dimension |
166 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
167 | Providing and fixing soil, waste and vent pipes 100 mm dia. Centrifugally cast (spun) iron socketed pipe as per IS: 3989. |
168 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of class designation 75 and S. W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With F.P.S. bricks |
169 | Add Carriage Charges |
170 | Retaining Wall |
171 | Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I)Ordinary soil A)Manual Means (i) Upto 3.0m. |
172 | PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) |
173 | Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications C RCC Grade M20 Case I Using concrete mixer |
174 | Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications |
175 | Back filling behind abutment,wing wall and return wall complete as per drawing and Technical specification |
176 | Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications |
177 | Supplying of quick setting cement compound as per specification. |
178 | Carriage Charge of Material |
179 | ASSEMBLY SHED |
180 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
181 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
182 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
183 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
184 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
185 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
186 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
187 | e) Column, pillars, posts and struts etc. |
188 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars. |
189 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
190 | Steelworkinbuiltuptubulartrussesincludingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
191 | ProvidingcorrugatedG.I.sheetroofingfixedwithgalvanisedironJorL hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpetwashers filledwith whiteleadcomplete,excludingthecost of purlins, rafters and trusses. (a) 0.63 mm thick GI sheet |
192 | Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately). First floor |
193 | Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood. |
194 | Extra for chamfered edges in beading |
195 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. b) size of tiles 600x600mm |
196 | Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand). |
197 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
198 | Add internal electrification |
199 | Add Carriage Charges |
200 | Entrance Gate with Guard Room & Boundary wall |
201 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
202 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
203 | Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
204 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
205 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
206 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
207 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
208 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
209 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
210 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
211 | e) Column, pillars, posts and struts etc. |
212 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars. |
213 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
214 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
215 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
216 | Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position. |
217 | Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I |
218 | Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm |
219 | Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessaryscrews etc complete. a) 300 x 10 mm |
220 | Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm |
221 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. b) size of tiles 600x600mm |
222 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
223 | Painting two coats with oil type wood preservative of approved brand and manufacture on new work. |
224 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
225 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
226 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade |
227 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade. |
228 | Steel work riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. b) In Tees, Angles, Flats and Channels |
229 | Add internal electrification |
230 | Add Carriage Charges |
231 | BOUNDARY WALL |
232 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t |
233 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
234 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcementin : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
235 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
236 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
237 | Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete. |
238 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
239 | e) Column, pillars, posts and struts etc. |
240 | Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars. |
241 | Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand). |
242 | Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth. |
243 | Extra for half brick masonry in superstructure above plinth level and up to floor two level. |
244 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill. |
245 | 12 mm cement plaster 1 : 4 (1 cement : 4 fine sand). |
246 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
247 | Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade |
248 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade. |
249 | Add Carriage Charges |
250 | Up-gradation of playground |
251 | Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto 1000 metres.) |
252 | Removal of Unserviceable Soil with Disposal upto 1000 metres (Removal of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per clause 305.) |
253 | Seeding and Mulching (Preparation of seed bed on previously laid top soil, furnishing and placing of seeds, fertilizer, mulching material, applying bituminous emulsion at the rate of0.23 litres per sqm and laying and fixing jute netting, including watering for 3 months all as per clause 308) |
254 | Grassing with " Doobs" Grass (Grassing with "Doobs" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) a)In rows 15 cm apart in either direction |
255 | Repairs & Maintenance including paiting works of existing school structure |
256 | Repairs to plaster in patches of 2.50 Sq.m. and under including cutting the patch to proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead. a) With cement mortar 1 : 4 (1 cement : 4 fine sand) |
257 | Fixing door chowkhat in existing opening including embedding chowkhats in floor, cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm shingle size), painting two coats of coal tar to sides of chowkhats and making good the damages to wall and floors complete including disposal of rubbish to the dumping ground within 50 m lead. |
258 | Fixing window chowkhats in existing openings including cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks with cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm single gauge), painting two coats of coal tar to sides of chowkhats and making good the damge to walls complete including disposal of rubbish to the dumping ground within 50 m lead. |
259 | Providing and fixing wooden cleats to doors and windows with approved fittings including removal of old cleats where necessary including painting, polishing or bees-waxing to match the existing shades. a) 1st class teak wood cleats with iron hinges and screws |
260 | Supplying and fixing glass panes with putty and nails including removal of broken glass panes where necessary. b) Glass panes 3 mm thick and area 0.1 Sq.m. each |
261 | Renewing wooden beams (not exceedng 4 m in length) in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete including removal of rubbish to the dumping ground within 50 m lead. a) Timber Plank Class A - IV |
262 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete b) Size of Tile 600x600 mm |
263 | Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. a) 0.80 mm thick GI sheet |
264 | Extra for straight cutting and waste in CGI sheet roofing for making opening of area exceeding40 Sq.dm. for chimney stacks, sky lights etc. a) 0.80 mm thick sheet |
265 | Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) |
266 | White washing with lime on old work to give an even shade. a) In two or more coats |
267 | Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
268 | Wall painting (one or more coats) with plastic emulsion paint of approved brand and manufacture on old work to give an even shade. |
269 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
270 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade |
271 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws a) Plain grill |
272 | Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work. |
273 | Painting two or more coats on GI sheets with superior ready mixed paint of approved brand and manufacture in white, grey or green shades on new work to give an even shade |
274 | Painting one or more coats on GI sheets with superior ready mixed paint of approved brand and manufacture in white, grey or green shades on old work to give an even shade |
275 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete |
276 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore |
277 | Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore |
278 | Providing and fixing brass stop cock of approved quality a) 15 mm nominal bore |
279 | Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required a) Long Pan patten WC Pan |
280 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) One urinal basin with 5 Litres CI automatic flushing cistern |
281 | Providing and fixing kitchen sink including making all connection excluding cost of fittings a) White glazed fire clay sink size 600x450x150 mm |
282 | Add Carriage Charges |