Tender For Additional/Alternator To 32 X Or Accn In Stn Hq Unchibassi Under Ge (S) Pathankot, pathankot-Punjab

Military Engineer Services-MES has published Tender For Additional/Alternator To 32 X Or Accn In Stn Hq Unchibassi Under Ge (S) Pathankot. Submission Date for this Tender is 26-02-2024. Mobile Generator Tenders in pathankot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41649005
Corrigendum : Tender For Additional/Alternator To 32 X Or Accn In Stn Hq Unchibassi Under Ge (S) Pathankot
Open Tender
Indian
Punjab
pathankot
26-02-2024

Tender Details

Tender For additional/alternator To 32 X Or Accn In Stn Hq Unchibassi Under Ge (S) Pathankot

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2024 corrigendum3 Date 22-02-2024
2 12-Feb-2024 amendment Date 26-02-2024
3 13-Feb-2024 Amendment BOQ 26-02-2024
4 13-Feb-2024 amendmentspages Other 26-02-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 229000.0 /-
Tender Value
INR 1.54 Crore /-

BOQ Items

Name of Work: ADDN / ALTN TO 32 X OR MD ACCN IN STN HQ UNCHIBASSI UNDER GE (SOUTH) PATHANKOT
Sl. No. Item Description
1Demolition of brick work/stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
2M& L for Brick work with sub class "B" (old size) brick, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified.
3M&L Brick work with sub class "B" bricks, straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 complete all as specified.
4Taking down cement plaster of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
5M & L for Rendering 15mm thick in CM 1:4 using liquid water proofing compound on brick work or concrete surfaces on wall, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid separately under respective item) all as specified and directed.
6M & L for rendering 10mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
7M & L for rendering 10mm thick in cement and sand mortar 1:3 using liquid water proofing compound on brick work or concrete surfaces of wall/floor in sunken portion, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid separately under respective item)
8M & L for rendering 10mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling/Top and sides of chajjas/facia of roof projection incl necessary formwork including finishing the surface even and smooth without using extra cement and complete all as specified and directed.
9Supply only liquid water proofing compound (ISI marked)
10M & L for Preparation of newly plastered/prepared surfaces of walls and applying 1mm thick wall care putty with two coats of oil bound distemper over a coat of primer to match the shade as per existing colour scheme/pattern complete all as specified and directed.
11M & L for complete removal of existing surfaces incl washing, rubbing down and stopping of distempered and painted surface of walls and applying 1mm thick wall care putty with two coats of oil bound distemper on wall to match the shade as per existing colour scheme/pattern complete all as specified and directed.
12Material and labour for preparation of newly plastered external surfaces of wall and applying two or more coats of 100% premium acrylic emulsion paint (Weather coat) having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10sqm (weather proof/weather coat ) without any brush marks on the surface in any colour over including necessary scaffoling up to three storeys height of bldgs, Shade/colour shall be approved by GE, All painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete as as specified and directed.
13Material and labour for complete removal of existing treatment surface externally of wall and applying two or more coats of 100% company premium acrylic emulsion paint (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Complete Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coate of exterior primer applied @ 0.90 litre/10 sqm (weather proof/weather coat) without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs, shade/colour shall be approved by GE, All painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and directed.
14Material and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all specified and as directed.
15Material and labour for complete removal of existing treatment from ceiling surface and applying two coat of white wash on undecorated surfaces without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and directed.
16Demolition of cement concrete ( un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
17Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided as slab, RCC water Tank, cover etc. for complete all as specified and directed (reinforcement cut as required to facilitate demolition).
18Filling of sunken floor with PCC 1:5:10 type-E2 using 40mm graded crushed stone aggregate including breaking and removal of existing filling of lime concrete/PCC/brick bats and rubbish out off the premises, etc complete all as specified and directed.
19M & L for two coats of Hot bitumen on newly plasterd surface of sunken portion complete all as specified and directed.
20S & F for steel water tubing light grade 40mm dia, galvanised, including short lengths fixed as spout as in walls of sunken portion of toilets complete all as specified and directed.
21M & L for 75mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregates) as in sub base for pavement, path etc, complete all as as specified and directed.
22M & L for 75mm thick PCC (1:3:6) type C-2 using 40m graded stone aggregates as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified.
23M & L for 25mm thick PCC 1:2:4 type B-0, using 12.50 mm graded stone aggregate, including finishing surface of concrete topping even and rough complete all as specified.
24Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified.
25S & L for Non-skid coloured ceremic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified.
26S & F for Glazed coloured ceramic tile 450 X 300 X 7 mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified.
27M & L for Non- skid ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6 complete all as specified.
28M & L for Non- skid ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4 complete all as specified.
29Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified.
30M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified.
31Round chamfering, to the edges of marble slabs complete all as specified and directed.
32Dismantling of bricks (laid flat or on edge) or brick tiles in floors, etc. (each layer) laid, bedded and pointed in any mortar complete all as specified and directed.
33Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00kg of cement per sqm complete all as specified and directed.
34M & L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate on roof slab including finishing the top surface even & smooth without using extra cement complete all as specifed and directed.
35M & L for Rendering 10 mm thick in CM 1:3 on flat roof surface mixed with liquid water proofing admixture as per manufacturer instructions when concrete surface is green, finished even and smooth without using extra cement complete all as specified and directed.
36M&L APP modified roof treatment over existing accessible RCC roof slab/chajjah/canopy/parapet wall to be executed through approved applicator of the membrane manufacturer with following specification including dismantling existing water proofing treatment of any description complete all as specified and directed:-(a) Cleaning existing surface properly.(b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufacture by the same agency as that of APP with adensity of 0.87-0.89 kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not les than 3.60 kg/Sqm reinforced with non-woven polyaster fiber of wieght not less than 160gsm/sqm using butane torch by torch application with 10 cm side laps and 15 cm end lap. Laying of membrane and physical property of membrane shall be as under:-(i) Membrane weight not less than 3.60kf/Sqm.(ii) Non woven polyester weight not less than 160 gsm/sqm. (iii) Softening point of membrane not less than 150 degree celcius.(iv) Joint tensile strength-lingitudinal not less than 650 sqcm and transverse not less than 450 sqcm at 230 degree celcius. (v) Tear strength-longitudinal not less than 300 N and transeverse not less than 250 N.(vi) Elongation and reinforcement not less than 30%.(vii) Impermeability under water pressure not less than 3kg/sqcm.(d) APP membrane shall be laid using butane Torch by Torch application with minimum 10 cm side overlap and 15 cms end lap.
37M & L for cement concrete tiles 25cm X 25cm X 20-22mm thick with grey cement and no pigment, machine pressed, set, jointed and pointed in white or coloured cement to match the shade of tiles over and including 20 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
38Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and directed.
39All as per Srl item No 38 here-in-before, but area exceeding 1.5 sqm and not exceeding 4.00 sqm each, complete all as specified and directed.
40S & F for Pressed steel frames of size 105 x 60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of PCC 1:3:6 type type C-1 using 12.5 mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
41S & F for Pressed steel frames of size 125 x 60 mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of PCC 1:3:6 C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
42S & F for Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S, Square tube, fixing in opening as per specification & drawing, complete all as specified and directed.
43S & F for factory made solid panel PVC door shutter 30 mm thick both side prelaminated with coloured paint (style) consisting of frame made out of M.S tubes for top & bottom rails complete all as specifed and directed.
44S & F for factory made 35 mm thick, 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
45S & F for factory made 35 mm thick, 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, suppllied and fitted to chowkhats complete all as specified and directed.
46S & F 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
47M & L 2nd class hard wood, plain fillets, square, rectangular or triangular in section, bullnosed, wrought, secured with nails or breads, sectional area ends 13.0 sqcm but n. exc 25 sqcm complete all as specified and directed.
48S & F for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, door shutters, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, complete all as specfied and directed.
49M & L Anodised aluminium powder coating (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
50M & L Anodised aluminium powder coating (thickness of powder coating not less than 50 micron) window and ventilator shutters, side hung type without sash bars, Aluminium sections weighing 0.55kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no) hinges type B-12 long 100mm long (2 no) suitable handle (1 no) and tower bolt 100mm long complete all as specified and directed.
51M & L Anodised aluminium powder coating (thickness of powder coating not less than 50 micron) window and ventilator shutters, fixed type with sash bar, aluminium section weighing 0.55 gk/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. peg stays 150mm long (1 No) hinges type B-21 long 100mm long (2 No) suitable handle (1 No) and tower bolt 100mm long complete all as specified and directed.
52S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC) of approved design/pattern, with approved standard section and fixed to the existing window frame with c.p brass/stainless steel screws @200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engr-in charge and all as specified.
53S & F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps (cooler stand) including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified.
54M & L Painting to newly surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
55Preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed.
56M & L for painting to old painted surfaces of wood or wood based surfaces of any description not othewise described over 10 cm in width or girth including preparation of surfaces, with two coats of synthetic enamel paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
57M & L for preparation of old painted steel surfaces of any description exc 10 cm width or girth and painting with two coats of synthetic enamel paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
58Supply only for stainless steel Butt Hinges, 100 mm long medium weight, complete all as specified and directed.
59S & F for 300 mm long stainless steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 volts and nuts, four on bolt plate and and fixed with hasp & staple staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section complete all as specified and directed.
60S & F for 150 mm long, stainless steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
61S & F stainless steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
62S & F for continous (Piano) type hinges stainless steel bright finish or electrogalvanised with width of flaps 40 mm, complete all as specified and directed.
63S & F for 300mm size stainless steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and directed.
64S & F 150 mm overall length of cover plate floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
65S & F for 40 mm dia, cupboard knobs fixed with nut, screw and washer of stainless steel, bright finished complete all as specified and directed.
66S & F Hasp and staple of size 100 mm safety type, stainless steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
67Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new pins/springclips glazed with oil putty fixed with beads or in wooden shutters complete all as specified and directed.
68S & F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and directed.
69S & F for 03 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in squae not exceeding 0.5 square metre in each pane complete all as specified and directed.
70S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
71All as per the description of item No. 70 here in before but fixed in repair complete all as specified and directed.
72S & F rotational moulded polythiene water storage tanks of capacity 500 litres three layers(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of existing PVC tank of any capacity complete all as specified and directed.
73S & F 20 mm dia for Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
74Taking up or down steel tubing and connections, including cleaning for refixing or removal to store for 15mm bore complete all as specified and directed.
75All as per Item No 74 above but 20 mm bore.
76S & F for steel water tubing medium grade, galvanised, including short lengths, fixedto wall/conceales in wall/ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, union etc, of 15mm bore complete all as specified and directed.
77All as per Item No 76 above but 20mm bore.
78Refixing of old steel water tubing and connections in new or old position medium grade, galvanised, including short lengths, fixed to wall/concealed in wall/ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, cap sand plugs, union etc, of 15mm bore complete all as specified and directed.
79As as per Item No 78 above but 20mm bore.
80S & F for vitreous china squatting pan "Orissa pattern" size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI "P" trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes etc fixed in rapairs, complete all as specified and directed.
81S & F for PVC low level flushing cistern, valveless, symphonic action, type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed in repairs, completeg all as specified and directed.
82S & F for vitreous china wash hand basin (flat back or angle back type), size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand incl waste pipe fixed in repairs complete all as specified and directed.
83S & F for CP Brass Centre Hole, wash basin Mixture tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nits, screwed for iron pipe and fixed for 15mm bore complete all as specified and directed.
84S & F for CP Brass Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore fixed in repair complete all as specified and directed.
85S & F for Stop valves, cast copper alloy, screwed down, high pessure, with crutch or butterflly handle, screwed both ends for iron pipe or for unions and fixed in repairfor 15mm bore complete all as specified and directed.
86S & F for Stop valves, cast copper alloy, Chromium plated with long shank and cup (Concealed type) screwed down, high pressure, with crutch for butterfly handle, screwed both ends for iron pipeor for unions and fixed in repair for 15mm bore complete all as specified and directed.
87S & F for Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair for 20mm bore complete all as specified and directed.
88S & F for Grating doom 100 mm dia with waste hole of PTMT. (minimum weight 25gms) complete all as specified and directed.
89S & F for Grating doom 1250 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
90S & F for PVC connection 15 mm size, of length 450 mm, with PTMT nuts complete all as specified and directed.
91S & F for 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6mm thick commercial quality ply-wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
92S & F for Staniless steel towel rail 20mm dia D-type 60cm long between flanges, including brackets and fixed to walls, complete all as specified and directed.
93S & F for Soap dish, stainless steel, approximate size 160 x 160 x 90mm complete all as specified and directed.
94S & F for Shower Rose Swivel shower of PTMT any colour for fixing with 15mm base pipe, (Minimum weight 40gms) complete all as specified and directed.
95S & F Waste pipe of low or high density PVC, 32 mm dia for Kitchen Sink & Wash basin complete all as specified and directed.
96S & F for Shelf of PTMT, fixed with and including Chromium plated brass screws and wooden/plastic cleats in repair complete all as specified and directed.
97S & F 20 mm bore stainless steel curtain rod with 1 mm thick wall thickness and each length not more than 1.8 metre including a pair of brackets and knobs with each length/piece, fixed on doors and windows opening for hanging curtains complete all as specifed and directed.
98S & F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in trenches/floors/walls for 75 mm bore of pipe fixed in repair complete all as specified and directed.
99All as per Srl Item No 98 above but 110mm bore of pipe.
100S& F for PVC (SWR) floor bend, plain including jointing with solvent cement 75 mm bore in repairs complete all as specified and directed.
101All as per Srl Item No 100 above but 110mm bore of pipe.
102S & F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore as in repairs complete all as specified and directed.
103Cutting holes in brick walls built in cement mortar or cement lime mortar and making good the dismantled portion in cement, mortar 1:3 or cement concrete 1:2:4 type B-1 as required for exc half brick but n exc one brick thick wall complete all as specified and directed.
104M & L Providing cement concrete type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in landings, Parapet walls, facia, cover slabs upon drainage system incl mecessary form work etc, complete all as specified and directed.
105Material and labour for coloured machine pressed precast concrete interlocking paver block any shape & size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade rubber moulded glossy finish with grey cement and pigment complete all as specified and directed. Note:- Shapes of interlocking block shall be triangular/Zigzag/Haxagon/or other colour of paver blocks & laying pattern shall be approved by GE.
106Meterial and labour for sand filling under floors or in foundations including watering and consolidation for layer of sand cushioning below interlocking paver black complete all as specified and directed.
107M&L reinforced cement concrete type B-1, 1:2:4 (20 mm graded crushed stone aggregate)as in slabs supported on walls, landings, balconies, canopies, deck slabs and in shelves and the like incl necessary form work etc, complete all as specified and directed.
108S & F for bath cabinet of size not less than 300mmx 450mm x 75mm deep with standard size of glass complete all as specified and directed.
109S & F sinks with drainage board made of staniless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing with cantilever brackets and connectiong union to pipe overall size 915 mm x 460mm bowl size 410mm x 330mm x 160mm fixed in rapair incl waste coupling and excluding waste pipe complete all as specified and directed.
110S & F for Stainless steel plate rack of size 900 x 600mm not less than 1mm thick fixed with brackets, screw and necessary arrangements fixed in repair complete all as specified and directed.
111M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in surface channels and drains complete all as specified and directed.
112Material and labour for extra for forming fair finished drain or channel30 cm inner girth in cement concrete, using extra cement, including forms, mould, mitred/stopped ends etc complete all as specified and directed.
113Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and n exc 1.5 depth and getting out in soft/loose soil, Note: (1) The excavation work will be carried out by mannualy or by mechanical means in any loation/area as directed by Engr-in charge. (2) Any damage ocur to water supply pipe line/electric cable/existing drain/sewage line during excavation work will be made good up to satisfaction of Engr-in Charge.
114Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
115Removing excavated soil material exc. 250m but n exc. 500 m and depositing where directed by Engr-in Charge.
116M & L 150mm Reinforced concrete pipes, class NP-3 laid and jointed complete with collars including demolition and breaking up drain pipes in cement mortar including demolition of PCC bedding and haunching complete all as specified and directed.
117M & L concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate for Bore of pipe 150mm complete all as specified and directed.
118Meterial and labour for Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and as directed.
119Material and labour for precast reinforcement cement concree 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and directed. Note: Reinforcement shall be measured and paid separately).
120Taking down carefully point wiring of any type, size and description from hard/teak wood batten/through pipes capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, ceilng roses, light fittings etc. complete and making good the disturbed surface to match with existing all as directed by Engr-in Charge.
121Taking down carefully sub main wiring of any nos of wire and size with earth wire from wooden batten/surfaceconduit/casing caping complete with its all accessories.
122Taking down main switches, distribution boards and cut outs etc. of any type and capacity along with the existing boards and removing the same from site and making good the disturbed surface/portion of walls all as directed by Engr-in Charge.
123Taking down exhaust fan keeping in safe custody for fixing against relevant schedule items complete all as specified and directed.
124Taking down electric water heater complete with all accessories such as safety valve, themostate, NRV, connection piece etc and keeping in safe custody for fixing under relevant schedule item complete all as specified and directed.
125M & L for modular point wiring with 1.5 sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volots grade drawn through and including PVC rigid concealed conduit of suitable size not less than 1.8 mm thick (ISI marked) with all accessories including suitable mdular plate (inner +outer) and sunken boxes of suitable sizes including 1.5 sqmm PVC FRLS insuated unsheathed copper conductor multistranded cable for continuous earth conductor connected to common earth dolly, complete all as specified and directed for following:- 1. Proper colour coding is to be followed as per IS Specification. 2.Cutting chases for point wiring concealed PVC rigid conduit shall be deemed t o be included in the qouted rate of item.
126One light controlled by one switch 5amp, SP, one way 240 volts.
127One Ceiling/Exhaust fan point controlled by one switch SP, one way, 5 Amp, 240 Volts.
128One multi pin socket 5 Amp independent.
129One multi pin socket 5 Amp one same board.
130One bell/buzzer controlled by one bell push.
131One light point controlled by two 2- way switch, with cables 1.5 sq. mm size.
132Ditto, all as per item No 126 hereinbefore but using 2.5 sqmm (nominal area) nultistranded copper conductor cable & 2.5 sqmm size PVC insulated FRLS and unsheathed copper conductor cable FRLS for earth coninuity (green colour) for one 3pin socket outlet 15 amp multi purpose independent point controlled by 16 Amp, switch, SP one way, 240 Volts for socket, complete all as specified and directed.
133Supply, fixing, stringing and drawing submain wiring with 2 run of single core, 4 sqmm PVC insulated and unsheathed, multi stranded copper conductor cable FRLS using colour code for phase red and neutral black with and including 4 sqmm PVC insulated and unsheathed FRLS conductor multi stranded cable in green colour connected to common earth point and connected to earth dolly drawn through PVC rigid conduit of suitable size, heavy grade (ISI marked) with and including all accessories, fixed to surface/recessed complete all as specified and directed. Note: 1Proper colour coding is to be followed as per IS Specfication.2 Two runs of single core cable with one run of earth cable of conduit shall be measured as one RM. 3. Cutting chases for submain wiring concealed PVC rigid conduit shall be deemed to be included in the qouted rate of item.
134S &F Mdular switch 1 way 6A, 1 module single, (ISI Marked) complete all as specified and directed.
135S & F Modular Bell push 6A, 1 module single, (ISI marked) complete all as specified and directed.
136S & F Modular switch 16A, 1 module single, (ISI marked) complete all as specified and directed.
137S & F Modular switch 2 way 6A, 1 module single, (ISI marked) complete all as specified and directed.
138S & F socket, 6A-2/3 pin combined 2 module, (ISI marked) complete all as specified and directed.
139S & F socket 6A/16A-2/3 pin combined 2 module, (ISI marked) complete all as specified and directed.
140S & F in modular power unit with 25 amps MCB & Plug for geyser complete all as specified and directed.
141S & F ceiling rose surface bakelite 65 x 50mm, three terminals (ISI marked) complete all as specified and directed.
142S & F Buzzer, Ding Dong AC, 230 volts, single pole complete all as specified and directed.
143Supply and fixing of Lamp holder, PVC/Polycarbonate type with back plate complete all as specified and directed.
144S & F Fan regulator modular type suitable for BLDC fan complete all as specified and directed.
145S & F LED Lamp 230 volts, 50 Hz, inverter LED 10 watt, lumen 900 lm, rated current 0.045A, CRI less than 80, Charging time 8 to 10Hrs, operating temperature-10 to 50 degree celcius , back time 04 Hrs, complete all as specified and directed.
146Supply and fixing LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up gwith three core flexible copper conducctor cable of suitable size from ceiling orse complete all as specified and directed.
147Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable odf suitable size complete all as specified and directed.
148S & F LED light fitting 1x9xW/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
149Supply and fixing decorative wall light, stainless steel, rust free fixture with glass diffusere suitable for 9 watt LED lamp E27 base including fixing of LED bulb of 9 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
150Taking down existing serviceable ceiling fan along with accessories and refixing the same after completion of B/R works and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
151Refixing only exhaust fan retrived from item No 124 and connecting up including provision of cable ceiling rose/connector to fan complete all as specified and directed.
152Supply and fix exhaust fan made of sturrdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, copper winding of sweep 250mm.
153Refixing onlye electric water heater retrived form item No 125 complete with all accessories such as safety valve, thermostate, NRV, commection piece etc. complete all as specified and directed.
154S & F High perfomrmance IP66 LED Street light 20 watt, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, and 20W LED light etc. drawn through and including 32mm bore GI light grade protection pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and directed.
155S& F 240V, 10 KA "B" curve miniature cicuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
156S& F 240V, 10KA "C" curve miniture circuit breaker (MCB) of SPN 40 Amp current carrying capacity 40 amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
157S & F SPN 8 way sheet metal enclosures factory made DB double door 230V AC, 50 Hz AC 200 Amp rated bus bar complete all as specified and directed.
158Supply and fixing sheet metal enclosure for double door MCB DBs, phosphatised, powder coated, triple pole & neutal (TPN), suitable for 4 way, 240 volts, IP 43 & IK 09 fixed on wall with din rail, neutral and earth br, in proper position and taking down old noe all as directed by the Engr-in Charge.
159Supply & fixing MCB triple pole and neutral (TPN) of capacity 40 to 100 Amps, 240 Volts, breaking capacity 10 KA, "C" series, fixed in proper position and taking down old one all as directed by the Engr-in Charge.
160Disconnecting and taking down existing tamper proof electric meter single phase, Re-assembling and refixing to the same location alongwith replacement of meter fixing bod made out of thermoplastic grey colour with transparent cover, cable enty cover, hinged flap, protection cover including cable enty integrated elastic membrane suitable to accomodated two single phase KWH mete and fixing meter box to flush wall and making connection with proper thimbles, good disturbed surfaces, refixing seals and wires of the fixing the existing meter in mete box complete all as specified and directed.
161Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connectiong with galvanized iron GI earth wire 4mm dia by means of bolt nit check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked) of size 15mm for protection of GI earth wire up to test point, 20mm dia GI light size grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C-1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation, earth work in nay type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 odf SSR Part-I and all as specified or indicated including testing on completion. Note: Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip up to 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
162Note: The schedule of credit has been attached in tender in Pdf format and amount of credit schedule i.e. Rs 181881.00 shall be deducted from the total amount of BOQ to arrive at the contract sum.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail