Tender For Additional/Alternator To Bldg. No P-180 In Tech Area At Afs Yelahanka And Certain Minor Works At Afs Yelahanka, yelahanka-Karnataka

Military Engineer Services-MES has published Tender For Additional/Alternator To Bldg. No P-180 In Tech Area At Afs Yelahanka And Certain Minor Works At Afs Yelahanka. Submission Date for this Tender is 15-02-2024. Mobile Generator Tenders in yelahanka Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

41648864
Corrigendum : Tender For Additional/Alternator To Bldg. No P-180 In Tech Area At Afs Yelahanka And Certain Minor Works At Afs Yelahanka
Open Tender
Indian
Karnataka
yelahanka
15-02-2024

Tender Details

Tender For additional/alternator To Bldg. No P-180 In Tech Area At Afs Yelahanka And Certain Minor Works At Afs Yelahanka

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-02-2024
2 10-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 36220.0 /-
Tender Value
INR 18.11 Lakhs /-

BOQ Items

Name of Work: ADDN/ALTN TO BLDG. NO P-180 IN TECH AREA AT AFS YELAHANKA AND CERTAIN MINOR WORKS AT AFS YELAHANKA
Sl. No. Item Description
1Demolition of brick or stone work built in cement mortar including all quoins, arches, pillar etc complete all as specified and directed.
2Dismantling structural steel work including doors, gates but excluding framed truss etc. all as directed.
3Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
4Dismantling of plain or corrugated roof steel sheet of any description complete all as specified and directed
5Demolition and breaking up Salt glazed stone ware/ AC Reinforced concrete pipes 200mm dia,laid in trenches set in cement mortar including PCC bedcomplete all as directed.
6Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deepin soft/loose soil and getting out complete all as specified and as directed.
7Excavation in trenches n exc 1.50m deep and 1.5m in wide and getting out in soft /loose soil complete all as specified and as directed
8Rough excavation not exceeding 1.5 m deep and gettining out in soft/ loose soil completeall as specified and directed
9Rough excavation exceeding 1.5 m deep and not exceeding 3m deep and gettining out in soft/ loose soil complete all as specified and directed.
10Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, anholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard / dense soil complete all as specified and directed.
11Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
12Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as sepcifed and as directed.
13M&L for Sand filling under floors or in foundations including watering and consolidation complete all as sepcifed and as directed. Note : Consolidated thickness will be considered for measurement and payment.
14M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to the measured) complete all as specified and as directed.
15M&L for treating the top surface of filled earth at the rate of 5 lites of emulsion per square metre of surface complete all as specified and as directed.
16M&L for treating the soil under plinth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed.
17M&L for Hard core, broken stone/boulder to gauge n exc 63mm as in sub base complete all as sepcifed and as directed.
18M&L for Plain Cement Concrete type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
19M&L for Plain Cement Concrete 1:4:8 type D - 2 (using 40 mm graded crushed stone aggregate) in foundation, filling and mass concretecomplete all as sepcifed and as directed.
20M&L for Plain Cement Concrete type B-1 ,1:2:4 (using 20mm graded stone aggregate) as in benching of manholes including forming centre channel half round or 1/4 section complete all as specified and directed.
21M&L for Plain Cement Concrete type C-1 (using 20mm graded stone aggregate) as in copings, band including necessary form work complete all as specified and directed.
22M&L for Pre-cast Cement Concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar type C1 1:3:6 and set in CM 1:6 , complete all as sepcifed and as directed.
23M&L for Precast Cement Concretetype B1 1:2:4 (using 20 mm graded stone aggregate) blockmasonary with solid blocks exc 10cm in width and setting in CM 1:6 complete all as specified and directed.
24M&L for Precast Reinforced Cement Concrete slab type B-1, 1:2:4 (using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including use of form work complete all as specified and directed.
25M&L for Reinforced Cement Concrete M-25 (Design Mix) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
26M&L for Reinforced Cement Concrete M-25 (Design Mix) in slab complete all as specified and directed
27M&L for Reinforced Cement Concrete M-25 (Design Mix) in Beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
28M&L for Reinforced Cement Concrete M-25 (Design Mix) in Columns, pillars, piers,posts and struts all as specified and directed.
29M&L for Reinforced Cement Concrete M-25 (Design Mix) in Chajjas complete all as specified and directed
30M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends all as specified and directed.
31Supply only liquid water proofing compound complete all as specified and directed.
32M&L for providing 40 mm thick damp proof course to horizontal or vertical surface including necessary formwork using plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) complete all as specified and as directed.
33Cutting openings through walls in cement mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for under pinning including providing, fixing and removing, shoring,cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and directed.
34Cutting holes in stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exe half brick but n exe one brick complete all as specified and directed.
35M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to flat complete all as specified and directed.
36M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, wall and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
37M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams etc complete all as specified and directed.
38M&L for use and waste of formwork to sides of pillars, posts, struts, piers, columns and stachions complete all as specified and directed.
39Taking down door chowkats or frames not exceeding 1.5 sqm with shutters (without taking off shutters from the frame) of any description all as directed.
40Taking down of shutters of any description exe 2 sqm each complete all as specified and directed.
41M&L for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in single side prelam PVC sheetused instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet all as specified and directed.
42M&L for Factory Made Solid PVC Moulded Door Shutter, with particle board core 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face including fixing in frame at site etc complete as specified and directed.
43S&F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
44S&F 150mm stainless steel (304 grade) butt hinges all as specified and directed.
45S&F 100mm butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and directed.
46S&F mild steel 150mm barrel tower bolts long, stove enameled black, with bright bolt and fixed complete all as specified and directed.
47S&F mild steel 300mm long sliding door bolts, stove enameled black, with bright bolt not less than 12mm dia with andincluding a minimum of 6 bolts and nuts, four on bolt pipe and two on staple plate and fixed complete all as specified and directed.
48S&F of powdered coated aluminium anodised, barrel tower bolt of length 200mm of extruded section complete all as specified and directed.
49S&F of aluminium anodised, barrel tower bolt of length 150mm of extruded section complete all as specified and directed.
50S&F of aluminium alloy anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheets , cast or extracted section and fixing bolt and sliding bolts of extracted section complete all as specified and directed.
51S&F of aluminium alloy anodised, sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clips of sheets , cast or extracted section and fixing bolt and sliding bolts of extracted section complete all as specified and directed.
52S&F of Butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type C-21 all as specified and directed.
53S&F of aluminium handle of size 150mm cast type anodised complete all as specified and directed.
54S&F of chromium plated towel rail 600 mm long fixed with chromium plated brass screws and wooden /plastic cleats fixed complete all as specified and directed.
55S&Fof floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor 150 mm size of cover plate all as specified and directed
56S&F Aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed all as specified and directed.
57S&F of Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed
58S&F of stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm and fixed with stainless steel wire staples all as specified and directed.
59M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking bending spirallv for hopping for columns, hooking ends and binding with and includingMS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
60All as per item No 59 above, but 6mm to 8mm dia.
61All as per item No 59 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
62M & L forRoof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe-410 gde 250 (quality "B") complete all as specified and directed.
63M&L for mild steel framed work as in door or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, door, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing confirming Fe-290 Gde 265 complete all as specified and directed.
64S&F of box type hinge steel windowswith double shutter with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded complete all as specified and as directed
65M&L for Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed to wall complete all as specified and as directed.
66S&F of powder coated anodised aluminium framewith all fixing arrangementsfor doors, windows andventilators with one or more rebates including joing cleat for fixing etc aluminium section of powder coating not less than 50 micron all as specified and directed.
67S&F of powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed.
68S&F of powder coated aluminium door/Windows/ventiliator shutters aluminium section weighing 0.55kg/m including necessary joining, fixed type, cleats, glazing clips, rubber neoprene packing, roller in each window, anodised alumnium snap beading, screw etc, complete all as specified and directed.
69S &F powder coated aluminium work forpartitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS :1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling,C.P brass/stainless steel screws all complete as per architectural drawing and the direction of Eng-in-Charge
70S&F of pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
71S&F of 9 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame work complete all as specified and directed.
72M&L for granite (of any type) tiles 20mm thick machine cut with miror polished, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completes in floors etc. set and jointed in neat cement slurry and jointed in white or coloured cement to match & including 10 mm thick screed bedin cement mortar (1:4) over 50mm thick PCC 1:2:4 type B1(using 20 mm graded aggregate) and pointed in white cementwith pigment to match the colour of tiles complete all as specified and directed.
73M&L for granite (of any type) tiles 20mm thick machine cut with miror polished, as in skirting bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing completes in floors etc. set and jointed in neat cement slurry and jointed in white or coloured cement to match & including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed.
74M&L for 75 mm thick Plain Cement Concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/hard standing and plinth protection complete all as specified and directed.
75M&L for 100mm thick Plain Cement Concrete1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base, floor and like complete all as sepcifed and as directed.
76M&L for 75mm thick Plain Cement Concrete 1:5:10 (using 40mm graded stone aggregate)as in sub base complete all as specified and directed.
77M&L for glazed ceramic coloured tiles in vertical surface of size 300mm x 200mm x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in cement mortar (1:4) and pointed in white cementwith pigment to match the colour of tiles complete all as specified and directed
78M&L for non skid ceramic white tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick screed bed in cement mortar (1:4) over 50mm thick PCC 1:2:4 type B2 (using 20 mm graded stone aggregate) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed
79M&L for non - skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed in CM 1:4 over 50mm thick plain cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) complete all as specified and directed.
80M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness,M-35 Grade with grey cement and pigment complete all as specified and directed.
81Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
82M&L for rendering 15mm thick in two layers (10mm and 5mm respectively) in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer"s instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
83M&L for Glazed coloured Ceramictiles of size 300x450X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchas in skirting/dadoincluding matching PVC corner beading and 10 mm thick rendering in CM 1:4 finished as in toilets and kitchen complete all as specified and directed
84M&Lfor rendering 15mm thick in cement morter 1:4on fair faces of brick work or concrete surfaces and surface to be finished even and smoooth with out using extra cement all as specfied and directed.
85M&Lfor rendering 15mm thick in cement morter 1:6on fair faces of brick work or concrete surfaces and surface to be finished even and smoooth with out using extra cement all as specfied and directed.
86M&L for rendering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
87M&L for cement rendering 5mm thick in cement mortar 1:3 on brick work for concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
88M&Lfor Non skid coloured Ceramic tiles 7 to 8 mm thick and area of each tiles exc 0.11 sqm but not exceeding 0.18 Sqmas inflooring including 15mm thick screed bed in CM 1:6complete all as specified and directed.
89M&L for preparation of newly plastered surfaces of interior wall and applying 02 coats of oil bound distemper over a coat of interior wall primer as recommended complete all as specified and directed.
90M&L for preparaton of newly plastered external walls/RCC surfaces/soffits of chajjas/roof projections/ cantilevers/ balcony etc and applying 02 coats of cement base paint over a coat of primer complete all as specified and directed.
91M&L for preparation of newly plastered ceiling surface and applying 03 coats of whitewash complete all as specified and directed.
92M&L for preparation of the old decorated wall surfaces andapplying one coat of weather proof paint complete all as specified and directed.
93M&L for preparation of old decorated wall surface and applyingone coat of oil bound distemper complete all as specified and directed.
94S&F of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m ineach pane complete all as specified and as directed
95S&F of sheet glass4.80 mm thick ordinary quality ,frosted both side,as in doors,window, ventilator,showcase aluminium frame work & similar work with or without glass roller any size including neoprime gasket and all necessary fixtures to fix complete all as specified and directed.
96S&F of5.5mm sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
97All as per item No 96 above but 4 mm thick figured glass pin head type
98Hacking out old broken glass (any thickness, size, quality or description) from Aluminium, steel, wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as directed.
99M&L for preparation of new steel surface of any description not exceeding 10cm in width or grith, not otherwise described andapplying two coats of synthetic enamel paint over a coat of zinc primer, red oxide complete all as specified and as directed.
100M&L for preparation of new wooden surface of any description not exceeding 10cm in width or grith, not otherwise described andapplying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
101S&F of GI tubing light grade 40 mm bore for mounting of garden lights complete all as specified and as directed.
102Taking up or down 15mm steel tubing and connections all as specified and directed.
103Taking up or down 20mm steel tubing and connections all as specified and directed.
104Taking up or down 25mm steel tubing and connections all as specified and directed.
105S&F CPVC pipes20 mm SDR 11 & Plain CPVC SDR 11 on walls, ceiling orlaying including fitting in floors all as specified and as directed.
106S&F CPVC pipes25 mm SDR 11 & Plain CPVC SDR 11 on walls, ceiling orlaying including fitting in floors all as specified and as directed.
107S&F in repair Bib taps chromium plated 15 mm dia fancy type with capstan head handle screwed both ends for iron pipe or for union complete all as specified and directed.
108S&F Pillar tap 15mm bore fancy type chromium plated, with capstan head screwed down high pressure with or without lettered “Hot or cold” with long screwed shanks fly nuts ,screwed for iron pipeand fixed in under counter wash basin completed all as specified and directed.
109S&F 15mm dia, stop valve concealed type chromium plate fancy type with long shank and cup complete all as specified and directed.
110S&F 25 mm boreball valves high pressure of PTMT withepoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
111S&F in repair PTMT Nipple 25 mm suitable for HDPE water tank (Minimum weight 20mm- 45gms ) complete all as specified and directed.
112S & FPTMT Shower arm 15 mm size, 195 mm long with bend of 45 degree with flangeas specified .
113S & F PVC connection pipe 15mm bore with PTMT Nut of length 600mm etc complete all as specified and as directed .
114S&F Modular 8mm thick beveled edge wall mounted frameless mirror of selected quality glass(single piece) all as specified.
115S&Fchromium plated health fauccet of including neccessary holding arrangements with screws etc all as specified and directed.
116S&F 15mm dia angle valves, cast copper alloy,chromium plated, screwed down, high pre-ssure, with crutch, screwed both ends for iron pipe or for unions
117S&F 15 mm dia two waybib taps with wall flange (fancy type), cast copper alloy with crutch or butter fly handle screwed down, screwed for iron/CPVC pipe or forbrass ferrule complete with check nut 15mm bore complete all as specified.
118S & F of 32/40mm waste pipe for wash hand basin all as specified and as directed
119S&F chromium plated grating size 100 / 75 mm fixed with white cement all as specified and directed
120S&F Stainless steel Soap dish fix to wall all as specified and directed.
121S&F Paper holder with Flap Recessed Type (Stainless steel)all as specified and directed.
122S&F110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including flat iron claim for proper fixing complete all as specified and directed.
123S&F75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including flat iron claim for proper fixing complete all as specified and directed.
124S&F PVC(SWR) bends 110mm dia complete all as specified and directed
125S&FPVC(SWR) bends 75mm dia complete all as specified and directed
126S&F PVC (SWR) ‘S’/"P" trap 110mm bore all as specified and directed.
127S&F PVC floor trap 75mm dia, including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
128M&L cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) bed to drain pipes of 200mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
129M&L for 200mm dia reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
130M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 200mm dia bore pipes complete all as specified and directed.
131Dismantling old urinal from toilets and making good the surface all as directed.
132S&F in repair vitreous china wash down water closet pan (pedestal pattern), white premium quality (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
133S&F 10 litre capacity PVC syphonic action type for low level flushing cistern including all fittings and including flushing pipe fixed all as specified and as directed.
134S& FBrass chromium plated shower rose of dia 125mm with swivel joints including fixing to steel pipe or union of 15mm bore all as specified.
135S&F plastic pedestal pattern seat cover with flat bottom and cover and MS chormium plated hanging type device all as specified and directed.
136S&F in repairvitreous china wash basin, white or coloured of size 550 x 400 mmwith padestal including bracketsall as specified and as directed.
137S&F 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
138S& F in repair for aluminium powder coated drapery rod 25mm dia fixed with suitable bracket complete. Note: Bracket will be measured and paid separately
139S& Fin repair aluminium powder coatedfancy type suitabe brackets fixed atboth endsof openings fixed over 1st class hard wood rounded wooden blocks 0f 65mm dia and 20mm thick fixed to stone wall/Brick wall using screws inclnecesary drilling & finished with polishingEach opening shall have two fillets at both ends all as specified and directed.
140Supply and FixPulley operated clothes drying system, 04 Nos pipe, 8 feet length consisting of anodized aluminium pipes, each of outer dia 22mm and inner dia 19.8mm , pulleys made up of Delrin with rope guide mounted on channel pair of length 24" and locking system to hide rope knot. Rope will be 4mm dia HDPE double core and self tapping screws complete all as specified and directed . Make: Pull-it 8Feet(4pipe) of Easy dry or equivalent
141M&L for water proofing treatment shall be comprising for the following complete all as specified and directed: - (a) 10mm thick cement plaster (1:3) using coarse sand mixed with acrylic based water proofing compound shall be provided while the concrete of roof slab is green and finishing surface even and smooth with steel trowel. (b) The surface shall be painted with one coat of cold applied bituminous primer @ 0.40 litre per sq. m, all as described in paras 11.44.5 of MES Schedule Part-I. (c) A layer of Atactic polypropylene polymer (APP) modified prefabricated membrane shall be applied over primed surfaces all as described in paras 11.44.5 of MES Schedule Part-I. (d) Benching (gola) at junctions of roof / terrace with parapets / side walls in concave shape of 80 mm radius with PCC (1:2:4), Type B-0, shall be laid. (e) Treatment mentioned in para 11.2A.1 (a), (b) & (c) shall also be provided over side walls/parapetsupto a height of 150 mm above roof slab. (f) APP modified polymeric membrane shall be covered with bituminous based aluminum paint @ 0.2 Kg per sqm in two coats. Note : The rate quoted by the contractor deemed to be inclusive of all the above applications.
142M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) single core PVCinsulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including non metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealedin existing brick/stone wall and provision of PVC Insulated heavy duty ISI marked, FRLS, unsheathed copper conductor, 1.5 sqmm for earth continuity conductor including modular type terminal boxes made out of Galvanised sheet of thickness should be not less than 0.9mm thick for fixing of modular swtches, modular fan regulators, modular socket outlets etc alongwith suitable modular plate for housing switches etc complete all specified and directedfor the following: -
143One light point controlled by one 6 Amps switch.
144One ceiling fan/Exhaust fan controlled by one 6 Amps switch.
145One socket 6 amp on Same Board with other switches.
146One socket 6 amp on independent board.
147All as per item No 142 above butwiring with 2.5 sq mm FRLS copper cable including earth continutyconductor with 2.5 sq mm FRLS copper cable for one6 pin 15 Amps socket outlet on independent board controlled by 16 Amps switch.
148Supply and fixing LED retrobar 20 Watt light fitting alongwith LED 1x 20W lamp complete, lumen efficacy 100Lm/W, 2.5 kV surge protection, power factor > 0.9, polycarbonate housing, CCT 6500K, 220V, AC with driver including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including dismantling old unsv fittings complete all as specified and directed.
149Supply and fixing LED light fitting (mirror light) with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
150Supply and fix switch piano flush type, single pole, one way 6 Amps all as specified and directed.
151Supply and fix fan speed regulator, electronic step type, suitable for single phase AC, 240 volts, 50 Hz, 100 watts all as specified and as directed.
152Supply and fix socket outlet 2 in 1, 3 pin, 6 Amps flush type all as specified and directed.
153Supply and fix switch socket combination 5 pin 6 Amps with box, multi pin flush type all as specified and directed.
154Supply and fixswitch socket combination 6/16 Amps with box, multi pin flush type all as specified and directed.
155S&F of metal clad socket outlet with Triple pole and neutral enclosure with two pin and earth plug socket complete with one triplepole MCB 32 Amps "C" Curve, 10 KA rupturing capacity complete all as specified and directed.
156Supply and fix sheet metal enclosures forMCB distribution board 230 Volts Single pole and neutral 8 way Double doorcomplete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified completeand directed
157S&F of Air termination, single pointed alluminium rod 12mm dia and 900mm long including floor coupling for joint the lightening conductor complete all as specified and directed. Note : The conductors and termination point should not touch the buildings surface and quoted rate is deemed to the inclusivee of fixingarrangements.
158S&F of Test Point Terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw including removing the existing u/s test point terminal bloch complete all as specified and directed by Engineer-in-charge. .
159S&F of Aluminium strip 25x3 with saddles and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
160S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete all as specified and directed
161S&F ofLT underground cableof size 4 core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc. on floors, roof and fixing using clamps, saddle for pole, wall complete all as directed.
162M&L for sub-main wiring with two runs of 1.5 sqmm unsheathed PVC insulated, single core cable with copper stranded conductor FRLS drawn through and including suitable dia metallic PVC conduit red conduit and conduit accesories concealed/fixed to wall/roof/floor and including suitable steel conduit with 1.5 sqmm FRLS copper earth wire and all as specified and directed Note: 2 runs of cable and one run earth wire and PVC conduit will be measured as one length.Three run of 1.5 Sq mm cable and steel conduct is measured as one Run or one Meter.
163M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated heavy duty ISI Marked, FRLS unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 25 mm dia non matallic rigid PVCconduit and condit accessories concealed and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 4 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface all as specified and as directed by Engineer-in-charge. Note:- Two run of cable and one run of earth wire and PVC conduct is measured as one lenth.
164Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete without fan regulator all as specified and directed
165Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed .
166Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed.
167Supply and fixing SPN 32 AMP rating 240V, 10KA "C" curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning all as specified and directed.
168Supply and fixLED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
169Supply and fix in repair including taking down building security light LED street light fitting 20 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed.
170M&L for boring of holes under roof, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including HDPE pipe of 75mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
171M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed
172Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanised iron earth strip 25x3mm thick by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip for lightning arrester shall be provided with HDPE pipe excavation earth work, PCC chamber RCC cover slab charcoal, salt watering pipe wiremesh water funnel etc all applicable and as per plate No 5 and all as specified.(Note (i) : The rate is inclusive of earth work and excavation PCC chamber in PCC (1:3:6) type C1 RCC Cover slab 50mm thick with RCC (1:2:4) type B1, with 8mm CTD bards re-inforcement both ways at 140mm centre to centre. Note (ii): Earthing lead from earth plate to test point upto 7.5 Mtr is deemed to be included.
Disclaimer :