Tender For Day To Day Maintenance Or Repairs To External Water Supply, Thiruvananthapuram-Kerala

Military Engineer Services-MES has published Tender For Day To Day Maintenance Or Repairs To External Water Supply. Submission Date for this Tender is 03-02-2024. Water Supply Project Tenders in Thiruvananthapuram Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

41648611
Corrigendum : Tender For Day To Day Maintenance Or Repairs To External Water Supply
Open Tender
Indian
Kerala
Thiruvananthapuram
03-02-2024

Tender Details

Day To Day Maintenance Or Repairs To External Water Supply Day To Day Maintenance Or Repairs To External Water Supply , External Electric Supply, Dg Sets , Lighting Protection System , Security Or Treet Lights , Chlorinator At Coast Guard Station Vizhinjam, Trivandrum

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jan-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 54000.0 /-
Tender Value
INR 27 Lakhs /-

BOQ Items

NAME OF WORK : DAY TO DAY MAINTENANCE/REPAIRS TO EXTERNAL WATER SUPPLY , EXTERNAL ELECTRIC SUPPLY,DG SETS , LIGHTING PROTECTION SYSTEM ,SECURITY /STREET LIGHTS ,CHLORINATOR AT COAST GUARD STATION VIZHINJAM, TRIVANDRUM8907/E8 Call-2
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottomsurfaces to required level complete all as specified and directed.
2Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil complete all as specified and as directed.
3Removing excavated soil to a distance n.exc 50m, and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
4Material and labour for providing dry screened river sand as in sand cushioning to under groundcable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
5Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection complete all as specified laid perpendicular to cable as per directed.
6Supply and fix XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed grade, 3 core cross sectional area 185 sq. mm including taking out complete all as specified and directed.
7Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
8Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 25 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
9Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 16 Sqmm 4 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
10Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 6 Sqmm 2 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
11Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed.
12Supply & Fix 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
13Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
14Supply and Fixing MCCB 4 pole 415 Volts, 50Hz, 3 phase of capacity 63 Amps, C curve 10 KA breaking capacity, fixed properly in DB and connecting/testing complete all as specified and as directed.
15Supply & Fix in replacement of MCCB 100 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
16Supply & Fix in replacement of MCCB 160 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
17Supply & Fix in replacement of MCCB 200 Amps,4 pole, 415 Volt adjustable type with breaking capacity 25 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
18Supply & Fix in replacement of MCCB 250 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
19Supply & Fix in replacement of MCCB 400 Amps,4 pole, 415 Volt adjustable type with breaking capacity 50 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Havells/ L&T / Legrand
20Supply and Fixin repairs drop out explusion fuse assembly with fuse carrier, triple pole for 11KV,current rating 100A outdoor type having tow nos post insulator mounted on MS channel for each pole completed all as specified and directed.
21Supply and fix in repair aluminium strip 25mmx3mm complete with saddles epoxy base and fixing screws for fitting the strip all as specified and directed.
22Supply and fixin repair for earth contunity conductor of size 32x6mm GI strip all as specified and directed.
23Supply and fix in repairs GOD Triple pole mechanically operated,mounted on insulator and steel frame wiht operating mechnism worked from ground level for current rating up to 200 Ams 11KV complete all as specified and directed.
24Supply and fix in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 Kilo Amps suitable for 11000V supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed.
25Dehydration / filtration of transformer oils of transformer/switch gears to achive die-electric strength not less than 40kv for 1 miniute at 4mm gap as per relevent IS using portable filteration plant including testing of oil for die electric strength before and after filtration complete all as specified and directed. Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electricity for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
26Supply and topping up new transformer oil into conservator tank/body tank of transformer using portable filtration plant and directed. Note:- (i) The transformer oil for topping up shall be with di electric strength more than 40kv for 1 miniute at 4mm gap. (ii) Oil shall be supplied at site in sealed barrel.
27Supply and fix in repairs LED Street light fitting 60 Watt Out door type, made of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protectioncomplete all as specified and as directed. Make: Crompton/Havells/Philips
28Taking down existing unsv terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No MCB of 6 AMP with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed.
29Cleaning and preparation of old painted surface of steel pole 11 mtr long excluding planting depth completeand painting with one coat of aluminium paintand makingblack and white strips with synthetic enamel paint30 cm height,each alternative strips ,up to 1.5 mtr height and writing poleNos and applying one coat of cement base paint on PCC coping complete all as specified and as directed.
30M & L for painting of HT/LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
31Supply and fixing post top lantern LED type 40 watt 230 watts volts AC outdoor type with decorative post top for 360 deegree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete Make: LPTO-40-CDL-M of Crompton Greaves/ Havells/Philips.
32Supply and fix LED bollard light with pole 10 watt, 240 volt with aluminium body pressure die cast powder coated housing with PC diffuser IP-65 protection with inbuilt LED chip and driver, accessoriesprewiredand fixingaccessories complete all as specified and directed. Make: 824.075L10H.NHG of Jaquar or equivalent in Crompton Greaves/ Havells/Philips.
33Supply, fixing, laying & testing galvanised iron water tubing of 25 mm dia, medium grade, ISI marked with and including all GI fittings such asunions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid intrenches/floor including taking out unserviceable pipe, complete all as specified and directed:-
34Supply, fixing, laying & testing galvanised iron water tubing of 40 mm dia, medium grade, ISI marked with and including all GI fittings such asunions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. laid intrenches/floor including taking out unserviceable pipe, complete all as specified and directed:-
35Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed.
36Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 40 mm bore complete all as specified and directed.
37Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50 mm bore complete all as specified and directed.
38Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
39Supply and fix in repairs CI Foot Valve, of 50 mm dia flanged / Screwed with GM working parts as per IS - 4038with nuts bolts and gaskets etc…, complete all as specified and directed
40Supply and fix in repairs CI Foot Valve, of 80 mm dia flanged / Screwed with GM working parts as per IS - 4038with nuts bolts and gaskets etc…, complete all as specified and directed
41Dismantling, Cutting and removingburnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductorwinding wire of existing size and capacity including insulating materials, varnishing baking etc andreinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 5.0 HP complete all as specified and directed.
42Material and labour for servicing of pump sets including replacement of Ball bearing, mechanical seal and greasing etc for the pump set capacity 5 HP complete all as specified and directed.
43Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 20mm bore complete all as specified and as directed.
44Supply and fix in repairs Float valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe suitable for 25mm bore complete all as specified and as directed.
45Material and Labour forcleaning underground sump of50000 Ltrs capacity by draining/ pumping out complete water from sump, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the sump, flushing out , washing of inner surface using lime and bleaching powder and clean water with the help of pump or drain out as required, applying a coat of white wash for all surfaces of the UG sump from inside, painting and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
46Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etcthrough drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleanedyearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakagesof tankof capacity 500 Ltrs. complete all as directed. Note: Tank shall be cleanedyearly as directed by Engineer-in-Charge.
47Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etcthrough drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleanedyearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakagesof tankof capacity 750 Ltrs. complete all as directed. Note: Tank shall be cleanedyearly as directed by Engineer-in-Charge.
48Material and labour for Cleaning of overhead tank by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etcthrough drain pipe or by manually and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleanedyearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakagesof tankof capacity 1000 Ltrs. complete all as directed. Note: Tank shall be cleanedyearly as directed by Engineer-in-Charge.
49Material and Labour for cleaning of static water tank of 50000 Litre capacity by draining/pumping out complete water from the tank, cleaning with wire brush for removing scales, algae etc from inside and removing silt accumulated at the bottom of the tank,flushing out with bleaching powder, washing of inner surface using lime and clean water with the help of pump or drain out as required, applying a coat ofwhite wash to all concrete surfaces of the tank from inside, painting of all metal parts and writing the date of cleaning and capacity etc in bold letters complete all as specified and directed.
50Dismantling, cutting and removingburnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductorwinding wire of existing size and capacity including insulating materials, varnishing baking etc andreinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 7.5 HP complete all as specified and directed.
51Dismantling, cutting and removingburnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductorwinding wire of existing size and capacity including insulating materials, varnishing baking etc andreinstalling in existing position, testing etc for three phase, 440 volts motors of capacity 1 HP complete all as specified and directed.
52Material and Labour for general servicing of Electrical Driven main pump of 7.5 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland,packing, capacitors, terminal blocks etc complete all as specified and as directed.
53Material and Labour for general servicing of Electrical Driven main pump of 1.0 HP capacity including replacement of Ball bearing, mechanical seal, cleaning, greasing, checking alignments, meggaring, with and including replacing gland,packing, capacitors, terminal blocks etc complete all as specified and as directed.
54Periodical maintenance / servicing of diesel Gen set of 200 KVA capacityt DG set kirloskar at ICGS Jetty Vizhinjamfor smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etcfor the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed. Engine Servicing /Gen overhauling :- (a) Checking the lubricant oil, topping up & changing filters if required (b) Checking the lubricant level and replacing if required (c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required
55(d) Checking/adjusting of sensers / controls of the Engine (e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc (f)Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters (g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required (h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers
56(i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal (j) Cleaning of air filter assembly (k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc (l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance (n) Removing unserviceable spares and fixing of new spares including testing etc
57Periodical maintenance / servicing of diesel Gen set of 62.5 KVA capacityt DG set kirloskar at ICGS Vizhinjamfor smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etcfor the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed. Engine Servicing /Gen overhauling :- (a) Checking the lubricant oil, topping up & changing filters if required (b) Checking the lubricant level and replacing if required (c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required
58(d) Checking/adjusting of sensers / controls of the Engine (e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc (f)Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters (g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required (h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers
59(i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal (j) Cleaning of air filter assembly (k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc (l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance (n) Removing unserviceable spares and fixing of new spares including testing etc
60Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 100 to 250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make :Kirloskar / Cummins/Crompton Greaves.
61Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 62.5KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make :Kirloskar / Cummins/Crompton Greaves.
62Supply only lubrication oil filter element with "O" ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed.
63Supply only lubrication oil filter element with "O" ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 200 KVA capacities of DG Sets complete all as specified and as directed.
64Supply only fuel filter element with "O" ringas required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
65Supply only fuel filter element with "O" ringas required at site for 200 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
66Supply only Air filter elementinner and outer as required at site with "O" ringas required at site for 62.5 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
67Supply only Air filter elementinner and outer as required at site with "O" ringas required at site for 200 KVA capacities of DG Sets complete all as specified and as directed. Make: MICO / Kirloskar / Ruston / Greaves Power cotton
68Supply only Governor control cable inner and outer for the 15 to 250 KVA cap/make gen set complete all as specified and as directed.
69Supply only Solenoled shut off valveassembly complete suitable to operate with 12/24 volts DC complete all as specified and as directed.
70Supply only Lube oil pressure sensor for Engine complete all as specified and as directed.
71Supply only Ammeter 0-100 Amps complete all as specified and as directed.
72Supply only Speedo meter cable including outer and inner cable complete all as specified and as directed.
73Supply only Push button switch complete all as specified and as directed.
74Supply only Ignition switch heavy duty with keys complete all as specified and as directed.
75Supply only AMF relay and replacement of micropocessor 12V/24 complete all as specified and directed.
76Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset of capacity 62.5 KVA to 250 KVA complete all as specified and as directed.
77Supply only "V" Belts/pump "V" belts dynamo "V" belts for 62.5 KVA DG set complete all as specified and as directed.
78Supply only "V" Belts/pump "V" belts dynamo "V" belts for 200 KVA DG set complete all as specified and as directed.
79Supply only Flexible over flow pipe steel armoured/braided flexible with suitable end sockets of size 15 mm dia of suitable length complete all as specified and as directed.
80Supply only lub oil SAE 15 W - 40for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling complete all as specified and as directed. Make :Castrol/Power Supreme
81Supply only distilled water to be filled in batteries complete all as specified and as directed.
82Supply only coolant suitable for Diesel generating sets complete all as specified and as directed. Make: Castrol/HP/IOC
83Supply and fix in repairs 400 A contactor 4 polecomplete all as specified and as directed.
84Taking down existing self motorof capacity 62.5 KVA to 200 KVAand servcing includingreplacment of unserviceable spare parts, Brush, holder, solonoid switch, armature bush, filed coil complete all as specified and directed.
85Dismantling andremovingfuel injection pump (FIP) of cap 62.5 KVA to 200 KVA andtaking out to authorised workshop andreplacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge
86Repairs to dynamo / alternator including removing from position remove the burntout armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as directed
87Supply and replacement of radiator hose of any capacity complete all as specified and directed.
88Supply and repalcement of fuel hose set nylon type of any capacity complete all as specified and directed.
89Supply and replacement of radiatorfan belt of any capacity complete all as specified and directed.
90Supply and fix in repairs control unit for DG set of any capacity complete all as specified and as directed.
91Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge.
92Repairs to 24 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
93Repairs to 12 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge.
94Supplyand fix in replacement of Dry cell tubular type 12 V / 110- 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixingas required at site to the concerned DG Set all as directed by engineer-in-charge. Make : EXIDE/AMRON
95Painting of 200 KVA capacity DG setinstalledat Jetty ICGS Vizhinjam after preparing the external surface apply one coat of spray painting by superior quality synthetic enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
96Painting of 62.5 KVA capacity DG setinstalledat ICGS Vizhinjam after preparing the external surface apply one coat of spray painting by superior quality synthetic enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed
97Supply and fix Aluminium Air termination rod 12 mm dia single pointed 300mm longalong withbase plate welded at bottom of termination rod, of size 10 cm longfabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners (wooden block) complete all as specified and as directed.
98Note:-(a) Contractors representative / engineer shall report to concerned JE E/M incharge of AGE E/M office at fore noon and after noon to collect routine/urgent works related to internalelectric supply till completion of work. The work shall be attendedby the contractor immediately. The contractor shall ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screwes, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure as availability of every type of requiste T&P items to his trades man.All routne / urgent job slip will be repaired and gotsignature of user"s and will be deposited to JE E/M with in 24hrs.In case of any delayin attending the complaint more than 8 hrs after handing over of routine / urgent work,the contractor shall be liable to pay the penalty as described in penalty caluse given here as under.
99(b)The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than eight hrs after handing over works of urgent nature to the contractor. The Engr-in-Chargeshall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 8 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of8 hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the Engineer-in-charge. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 200/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.The decision of the Accepting Officer is this regards shall be final and binding. (c) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
100Schedule of Credit (Minus) Rs.60440.00 NOTE: Bidder shall insert credit amount of Rs. 60440.00 as ratein Green field under Col-13.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail