Tender For Repair/Maintenance Of Ac Plants, Ahu, Vrf, Acs Cold Storage, Icr And Other Allied And Connected Works In Tech And Domestic Area At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda, kalaikunda-West Bengal

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Ac Plants, Ahu, Vrf, Acs Cold Storage, Icr And Other Allied And Connected Works In Tech And Domestic Area At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda. Submission Date for this Tender is 22-02-2024. Air Handling Unit Tenders in kalaikunda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

41648031
Corrigendum : Tender For Repair/Maintenance Of Ac Plants, Ahu, Vrf, Acs Cold Storage, Icr And Other Allied And Connected Works In Tech And Domestic Area At Air Force Station Kalaikunda Under Ge (Af) Kalaikunda
Open Tender
Indian
West Bengal
kalaikunda
22-02-2024

Tender Details

Repair / Maintenance Of Ac Plants, Ahu, Vrf, Acs Cold Storage, Icr And Other Allied And Connected Works In Tech And Domestic Area At Air Force Station Kalaikunda Under Ge ( Af ) Kalaikunda Repair / Maintenance Of Ac Plants, Ahu, Vrf, Acs Cold Storage, Icr And Other Allied And Connected Works In Tech And Domestic Area

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Jan-2024 AMENDMENT FOR REPAIR/MAINTENANCE OF AC PLANTS, AHU, VRF, ACS COLD STORAGE, ICR AND OTHER ALLIED AND CONNECTED WORKS IN TECH AND DOMESTIC AREA AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA Other 10-02-2024
2 02-Feb-2024 REVISED BOQ AND REVISED SCHEDULE OF CREDIT BOQ 10-02-2024
3 10-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-02-2024
4 17-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-02-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 103000.0 /-
Tender Value
INR 52 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINTENANCE OF AC PLANTS, AHU, VRF, ACS COLD STORAGE, ICR AND OTHER ALLIED AND CONNECTED WORKS IN TECH AND DOMESTIC AREA AT AIR FORCE STATION KALAIKUNDAUNDER GE (AF) KALAIKUNDA
Sl. No. Item Description
1S&F in repair expansion valve suitable for 5.5 TRPackage type AC plant ofexisting Model ACDPU ASC 55R407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified. Make : Danfoss model TCBE R22/ R407C (068U4202) orVoltas model No. AC153000283
2S&F in repair expansion valve suitable for 8.5 TRPackage type AC plantof existing modelModel ACDPU ASC 875DR407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified. Make : Danfoss modelTCBE3 R22/ R407C (068U4203/AAE8 061186)orVoltas model No. AC153000283
3S&F in repair expansion valve suitable for 11 TRPackage type AC plantof existing modelModel ACDPU ASC 110R407as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified. Make : Danfoss modelTCBE2 R22/ R407C (068U4203/AAE8 061186) orVoltas model No. AC153800289
4S&F in repair expansion valve for suitable for 14 TR compressor of central type water cooled AC plant of capacity 14 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.complete all as specified and as directed.
5S&F in repair expansion valve for suitable for 28 TR compressor of central type water cooled AC plant of capacity 28 TRas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
6Supply and charging R-22 gasas as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
7Supply and charging R-407C gas as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
8M&L for descaling of shell & tube type condensers of Central AC plant of capacity 3 x 14 TR with the help of descaling chemicals and nylon wire brush as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
9All as per item No 8.00 here in before but for central AC plant of capacity 3 x 28 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
10All as per item No 8.00 here in before but for central AC plant of capacity 4 x 28 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
11M&L for descaling air cooled type condensers of package AC plant of capacity 5.5 TR with cleaning acid by forced feed method to remove thedust particles formed on the coil and fins as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
12All as per item No 11.00 here in before but for package AC plant of capacity 8.5 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
13All as per item No 11.00 here in before but for package AC plant of capacity 11 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
14M&L for Cleaning of evaporator coil of package typeAC plant of capacity 5.5 TR with dilute HCL by forced feed method to remove the dust particles formed on the coil and fins ,cleaning of liquid lines, strainer, expansion valve complete all as specified and as directed.
15All as per item No 14.00 here in before but capacity 8.5 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
16All as per item No 14.00 here in before but capacity 11 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
17All as per item No 14.00 here in before but for central AC plant of capacity 3 x 14 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
18All as per item No 14.00 here in before but for central AC plant of capacity 3 x 28 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
19All as per item No 14.00 here in before but for central AC plant of capacity 4 x 28 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
20M&L for taking out burned winding ofupto 3HP blower motor out door and rewinding with new winding as per existing guage of super enamelled copper wire including shaft, bearing, coupling complete s per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
21All as per item No 20.00 here in before but for above 3 HP and upto 7 HP as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
22All as per item No 20.00 here in before but for above 7 HP and upto 10 HP as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
23S&F V belt of size A-28 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
24S&F V belt of size A-36 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
25S&F V belt of size B-63 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
26S&F V belt of size B-65 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
27S&F V belt of size B-68 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
28S&F V belt of size B-79 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
29S&F V belt of size B-82 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
30S&F V belt of size B-84 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
31S&F in repair Airfilter for AC plant of capacity 5.5 TR, model ACDPU ASC 55R407, as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
32S&F in repair Air filterfor8.5 TR Package type AC of size390 x 605 x 36 mm complete for Voltas make Package type AC plantof Model ACDPUASC875DR407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
33S&F in repair Air filterfor 11 TR Package type AC of size 1016x774x5 mm complete for Voltas make Package type AC plantof Model ACDPUASC110R407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
34S&F in repair Air filterforAHU of central type AC plant of14 to 28 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
35S&F in repair Low pressure switch ( MW FL LP W/C switch YK 01L000- 035G050G) suitable forVoltas make Package type AC plant capacity 5.5 to 28TR includingwiring,copper tubing of the existing length as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
36S&F in repair High pressure switch ( MW FL A/C HP switch YK 01H000- 450P350R) suitable forVoltas make Package type AC plantofcapacity 5.5 to 28 TR (Make : Voltas, Part No AC 1505229HF450) includingwiring,copper tubing of the existing length as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
37S&F in repair High pressure gauge 0-300 Psi as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
38S&F in repair Low pressure gauge 0-150 Psi as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
39S&F in repair Pressure gauge 0-100 kg/cm2 suitable for condenser water pipe line as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
40S&F in repairmeter gauge for temperaturesuitable for water pipe line as per sampleas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
41S&F canvas cloth in between AHU and cold air duct of AC plant after removing the unserviceable cloth as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
42Supply, Fixing and testing in repair Microprocessor with & including display,relay circuit, sensors & display cable for Package units of capacity 5.5 TR to 11 TRincluding making all electrical connectionsas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
43Supply, Fixing and testing in repair Microprocessormodel EC, type M2VPD, 50 30 Amps 230 voltwith & including display, display cable for central AC plants of capacity for suitableupto 28 TRwith and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
44Supply, fixing in repair and testing controller model 22TR scroll V2A, type Delux, and Aux supply 15 AC including making all electrical connections as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
45Supply, fixing in repair and testingSMPS for central AC plant 14 TR to 28 TR including making all electrical connections as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
46S&F in repair ofMNX 25, 3 Pole Power contactor (AC 3 Rating 25Amp, AC 1 Rating 45 Amp)with aux 1 NO contact & 1 NC contact including making all necessary connections as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
47S&F in repair of MNX 32, 3 Pole Power contactor(AC 3 Rating 32 Amp, AC 1 Rating 55 Amp) with aux 1 NO contact & 1 NC contact as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
48S&F in repair of MNX 40, 3 Pole Power contactor (AC 3 Rating 40 Amp, AC 1 Rating 55 Amp) with aux 1 NO contact & 1 NC contact as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
49S&F in repair of MNX 80, 3 Pole Power contactor (AC 3 Rating 80 Amp, AC 1 Rating 100 Amp ) with aux 1 NO contact & 1 NC contactas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
50S&F in repair of 5.5/11 TRblower, shaft, bearingand motor assy complete ( Blower assly KAT15X15SCW 180D25)for 11 TR Voltas make Package type AC plantof Model ACDPUASC110R407as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
51S&F in repair of 8.5 TRblower, shaft , bearing and motor assy complete (Fan scroll assly)for 5.5/8.5TR Voltas make Package type AC plantof Model ACDPU ASC 55R407/ ACDPU ASC 875DR407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
52S&F in repair of Pillow block bearing for shaft approx 50mm suitalble for existingblower drum shaft assembly of AC plant of capacity 5.5 TR to 28 TR,as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
53S&F in repair of existing streamer for 5.5/8.5 28 TR including heating element, electrical connections and painting as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
54S&F in repair of Fan blade suitable for air cooled condensor of AC plant of capacity 5.5 / 8.5 TR as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
55Supply, fixing in repair, testing and commissioning Fan motor 0.75 HP, suitable for Package type AC plant 5.5 TR of Model ACDPUASC 55R407as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
56Supply, fixing in repair, testing and commissioning of Fan motor 1 HP, 3 Phase, 415 volts,suitable for Package type AC plant 8.5 TR of Model ACDPUASC875DR407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
57Supply, fixing in repair, testing and commissioningof Fan motor 2 HP, suitable for Package type AC plant 11TR of Model ACDPUASC110R407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
58S&F in repair Polycarbonate Connector for 40 A, 440 VoltSP, DP, TP & TPN as per existing model as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
59S&F in repair MCB TP 6 to 32 Amps, 415 Volts, 10KA, ‘C’ series complete all as specified and as directed.
60S&F in repair MCB TPN 6 to 32 Amps, 415 Volts, 10KA, ‘C’ series complete all as specified and as directed.
61S&F in repair MCB TP 40 to 63 Amps, 240 Volts, 10KA, ‘C’ series complete all as specified and as directed.
62S&F in repair MCB TPN 40 to 63 Amps, 240 Volts, 10KA, ‘C’ series complete all as specified and as directed.
63Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 3 pole, with current rating 160 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In,complete all as specified and directed.[Schneider /Legrand / ABB/Hager.]
64Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting:6-10 x In,complete all as specified and directed.[Schneider Model : Easy Pact CVSCat Part No.LV516343 or equivalent Model of Make Legrand / ABB/Hager.]
65S&F in repairMCCB with Thermal - magnetic release of 160-200 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit settingconforming to IEC 60947-2& IEC 60947-2 including all accessories like spreader terminals and separator, etc. complete all as specified and as directed. [Schneider /Legrand / ABB/Hager.]
66S&F in repair Voltmeters / Ammeters digital type 0 to 500 Volt AC +0.1 accuracy, 3 phase, 415 V including making necessay connections complete all as specified and as directed.
67S&F in repair selector switch for ammeter, voltmeter and necessay connections complete all as specified and as directed.
68M&L for wiring single core FR PVC insulated unsheathed cable, 1100 volts, grade having stranded copper conductor of nominal cross sectional area 16 Sqmm 4 core including taking out old unserviceable wiring complete all as specified and as directed. (Note: - The quoted rate shall be deemed to include for the cost of epoxy/PVC connection and copper terminal lugs as required.)
69S&F in repair stop valves 20 mm bore, cast copper alloy, screwed down high pressure with crunch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
70S&F in repair ball brass valves high pressure, with polythelne float and fly nut complete screwed for iron pipe of size 20 mm bore complete all as specified and as directed.
71S&F in repair gland packing, as per existing sample, for unions complete all as specified and as directed.
72M&L for applying two coats of synthetic enamal, anti rust /anti crossive for suction / discharge pipe ofAC plant and panel board etc in red / yellow/ blue /half white including preparation of surfaces complete all as specified and as dierected.
73Supply, fixing in repair, testing and commissioning of condensor assy for 5.5 / 11 TR Voltas make Package type AC plantof Model ACDPU ASC 55R407 / ACDPUASC110R407, connecting all copper pipes, electric connections as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
74Supply, fixing in repair, testing and commissioning of condensor assy for 8.5 TR Voltas make Package type AC plantof Model ACDPU ASC 85R407, connecting all copper pipes, electric connections as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
75Supply, fixing in repair, testing and commissioning of14 TR Shell & Tube type condensor unitsuitable for Voltas Centralised AC plant including making all necessary connections by brazing of copper pipes, pressure testing and vaccumising complete including charging the system with fresh refrigerent R-22 and re-commissioning of the same (Make of Condensor : Voltas) as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified. Note : (i) Contractor shall submit the purchase voucher and test certificate of condensor unit before incorporting in work. Payment shall be release after obtaing the same. (ii) Cost of refrigerant gas shall be paid separately under relevant item.
76Supply, fixing in repair, testing and commissioning ofup to 28 TR Evaporator coil for shell & Tube type condensor unit suitable for Voltas Centralised AC plant including making all necessary connections by brazing of copper pipes, pressure testing and vaccumising complete including charging the system with fresh refrigerent R-22 and recommissioning of the same as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.. Note : (i) Evaporator coil unit should be approved by GE before incorporting in work. (ii) Contractor shall submit original purchase voucher and manufacturer test certificate of Evoporator coil unit. Payment shall be released after obtaing the same. (iv) Cost of refrigerant gas shall be paid separately under relevant item.
77Supply, fixing in repair, testing and commissioning of 5.5TRScroll compressor HLP072T4LC6/121L1753 suitable for 5.5 / 11 TR Voltas make Package type AC plantof Model ACDPU ASC 55R407 / ACDPUASC110R407 as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
78Supply, fixing in repair, testing and commissioning of14 TR scroll compressor unitsuitable for Voltas Centralised AC plant including making all necessary connections by brazing of copper pipes, pressure testing and vaccumising complete including charging the system with fresh refrigerent R-22 and recommissioning of the same (Make of Compressor : Voltas/Danfoss) as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified. Note : (i) Contractor shall submit the purchase voucher and test certificate of compressor unit before incorporting in work. Payment shall be release after obtaing the same. (ii) Cost of refrigerant Gas paid separately under relevant item.
79M&L for cleaning of cooling tower of central type AC plant of capacity 8.5 TR to 28 TR, removal of water tray, pipe line and cleaning of cooling tower fins by using brush, painting of external body with spray paint as per exisitng colour as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
80S&F in repairshaft approx upto 50mm for blower drum for suitable arrangement like cutting, filing to lathe etc existing AC plant of capacity 5.5 TR to 28 TRas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
81S&F in repairAC plant control Panelof capacity 5.5 TR to 11 TR (Make : Voltas AC1590625003P) as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
82S&F repair to AC plant control Panelof capacity 5.5 TR to 28 TR andrewiring of the defective wiring of panel, as per existing, by proper connection using thimble, connector and replacement of unserviceable accessories refixing all the items as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..(Note :-The quoted rate shall deemed to be included for the cost of minor parts, wire required for making the panel fully functional.)
83S&F in repair Condenser sefety valve or high/low pressure valve of size 7/8" as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
84S&F in repair Butterfly valve of size 80mm bore, as per existing, for CI/GIwater pipe line inlet/outlet as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
85S&F in repair Copper pipe of size 7/8" with elbow and sockets as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
86S&F in repair Copper pipe of size 5/8" with elbow and sockets as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
87S&F in repair Copper pipe of size 1/2" with elbow and sockets as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
88S&F in repair Copper pipe of size 1" with elbow and sockets as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
89M &L for taking out the damaged glass wool insulation portion of existing wall of AHU room, cleaning the wall, andfixing the glass wool aluminium foil insulation size of 25mm thick, (1x30) mtrsuitable arrangement for fixing to wall and making good the disturbed portions as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
90M &L for taking out the damaged insulation portion of existing, duct out side , copper pipe etc, cleaning the duct, applying two coats of CPRX or suitable compound to cleaned portion of duct, fixing of 15 mm thick nitrile rubber along with out side aluminium coating and making good the disturbed portions as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
91S&F in repair Battery valve suitable for existing Temperature/ Humidity meter as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
92S&F in repair and calibration of existing Temperature/ Humidity meter as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
93M&L for repairing ofcorroded sheet metal body ofindoorunit of Package type AC plantof 5.5/8.5/11 TR capacity, with newCRCA sheet of 2.0 mm thick including painting of sheet with two coats of senthetic enamel paint (seimens grey paint) over a coat of red oxide primer including preparation of surfaces, as per exisiting, includingwelding, cutting, fixing work as required, including taking down and refixing spares of plantsas per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
94M&L for repairing ofcorroded sheet metal body ofindoorunit of Package type AC plantof 5.5/8.5/11 TR capacity, with newCRCA sheet of 0.6 mm thick including painting of sheet with two coats of senthetic enamel paint (seimens grey paint) over a coat of red oxide primer including preparation of surfaces, as per exisiting, includingwelding, cutting, fixing work as required, including taking down and refixing spares of plants as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
95M&L for repairing of duct of GI sheet, of existing size with newCRCA sheet of suitable existing size, fabrication work, includingwelding , cutting , fixing work as required including taking down old duct any type/size as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
96Supply and fix FR PVC insulated, sheathed copper conductor cable 1100 volt of size 10 Sqmm 4 core, fixed to wall etc as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
97Supplying & fixing towalls , ceiling and laid in trenches20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
98S & F in repairs 20 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
99Supplying & fixing towalls , ceiling and laid in trenches50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
100M&L submersible cable FR PVC insulated unsheathed cable, 6 Sqmm, 3 core 1100 volts, grade having stranded complete all as specified and as directed.
101S&F in repair Thermal relay 15 Amp to 32 Amps as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified..
102S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A complete all as specified and as directed.
103M & L for copper earth continuity conductorof size 25x3.15 mmstrip with insulator fixed to wall (porcelin insulater 10 BM heavy duty, ceramic bus bar supportinsulator off whitecolour of min size of 50 mm width x 70 mm length with 50 mmwidth bus bar mounting base) for fixing strip or drawn in conduit/pipe as required, including taking down old GI rusted strip complete all as specified and as directed. Note: Insulator to be fixed on every 50cm distance and cost of insulator is deemed to be included in unit rate of item.
104M&L for POP (Plaster of parris) on 150 mm CI pipe of AC palnt,provision of chicken wire mesh including removel of old POP and make good as distrubed surfaces complete all as specified and as directed.
105M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete with and including demolition of concrete of any description and in any position not otherwise specificallyand removing unserviceable material exc 1500 mtrout side of MOD land complete all as directed as specified.complete all as specified and directed.
106Supply, fixing, testing and commissioning monoblock pump 5 HP, suitable for central type AC plant upto 28 TR and taking out old unserviceable pump as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
107Supply, fixing, testing and commissioning self priming monoblock pump 0.5 HP, suitable for central type AC plant upto 28 TR including taking out old unserviceable pump as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.
108Comprehensive maintenance as per Original Equipment Manufacturer"s (OEMs) reccommendations for a period of ninemonths and repair including renewal/replacement of defective parts of all existing defective parts of VRF AC PLANT of Cap 30HP Make of samsung MODEL AM300KXUANH,complete indoor-24 Nos and out door units - 02 nos installed at Logistic section, including carrying out the Physical and health check up and service, gas pressure, electrical connections, etc. During the check up ofVRF AC PLANT, including minor/major parts if found defect/unserviceable then the same to be replaced and rateshalldeemed to be included in the unit quoted rateswith and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.NOTE : (i) OEM Rep will visit afterevery 03 months for routine maintenance . However, during any emergncy or breakdown , Rep of OEM shallvisitthe site within 24 hrs for minor repair and within 72 hrs for Major repair. If rep of OEM not atteneded within the time frame as mentioned then penal recovery of Rs 1000/-per hrs shall be recovered from the contractor . So, tenderer"s are advised to keep this aspect while quoting the rate. (ii) Minor repair include PCB replacement , Pump replacement etc .(iii) Major repairs include compressor replacement, gas charging & any refrigerant circuit part replacement .(iv) AMC period shall be of 09 months and include replacement of Compressor , Fan Motor, PCB , Gas charging , Magnetic Switch , transformer , Electronic Expansion Valve, Sensor etc. (v) Contractor"s rep(OEM)shall visit after every 03 months for periodical maintenanceto check all the complete system of VRF units,to check its functionility and to make them functional. (vi)Servicing of VRF units shall be carried out through OEM only . Contractor shall have to submit the MoU with the concerned OEM for maintenance of VRF ACs before theissue of work order .(vii) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing(VIII) Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of AC plantincluding maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentmanufacturer"s instructions. (Viii) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencieswill carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDAofficials or their representatives, The OEM"s authorised service representative or OEM certified agencies or approved will carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (IX) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.200.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (X). Each maintenance job shall be covered period of 09 Months (XI)Cost ofmajor/ minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & boltsPCB replacement , Pump replacement ,compressor replacement, gas charging & any refrigerant circuit part replacement and like shall be deemed to be inclusive of the quoted rate.
109Comprehensive maintenance and repair including renewal / replacement of minor defective parts of VRF AC PLANT 14 HP Make of samsung MODEL AM140KXMDGH complete indoorcassette type -06 Nos and out door units - 02 nos installed at DWR, including carrying out the Physical and health check up and service, gas pressure, electrical connections, etc. During the check up ofVRF AC PLANT, including minor/major parts if found defect/unserviceable then the same to be replaced and rateshalldeemed to be included in the unit quotedrate as per quotation/aggrement attach . NOTE : (i) OEM Rep will visit afterevery 03 months for routine maintenance .(ii) Minor repair include PCB replacement , Pump replacement etc .(iii) Major repairs include compressor replacement, gas charging & any refrigerant circuit part replacement .(iv) AMC period shall be of 09 months and include replacement of Compressor , Fan Motor, PCB , Gas charging , Magnetic Switch , transformer , Electronic Expansion Valve, Sensor etc. (v) Contractor"s rep(OEM)shall visit after every 03 months for periodical maintenanceto check all the complete system of VRF units,to check its functionility and to make them functional. (vi)Servicing of VRF units shall be carried out through OEM only . Contractor shall have to submit the MoU with the concerned OEM for maintenance of VRF ACs before theissue of work order .(vii) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing .(VIII) Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of AC plantincluding maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentmanufacturer"s instructions. (Viii) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencieswill carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDAofficials or their representatives, The OEM"s authorised service representative or OEM certified agencies or approved will carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (IX) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.2000.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (X). Each maintenance job shall be covered period of 09 Months (XI)Cost ofmajor/ minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & boltsPCB replacement , Pump replacement , replacement of Compressor , Fan Motor, PCB , Gas charging , Magnetic Switch , transformer , Electronic Expansion Valve, Sensor etc and like shall be deemed to be inclusive of the quoted rate.
110Comprehensive maintenance and repair including renewal / replacement of minor defective parts of Cold Room Servicing, fan motor Compressor Oil Charging, Suctionnitile rubber ,Liquid Line Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed. Make Blue star (02 Unit) or in equivalent. Note : (i) OEM Rep will visit afterevery 03 months for routine maintenance .(ii) AMC period shall be of 09 months and included replacement of necessary Spare parts ,compressor ,refrigerant ,controller ,contactor ,capacitor ,filter,copper insulation etc . (iii) Contractor"s rep (OEM)shall visit after every 03 months for periodical maintenanceto checkthe complete system ,to check its functionility and to make them functional. (iv)Servicing of walk in cooler unit (cold room) units shall be carried out through OEM only . Contractor shall have to submit the MoU with the concerned OEM for maintenance of walk in cooler unit (cold room)before theissue of work order .(v) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing .vii) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing .(VIII) Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of AC plantincluding maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentmanufacturer"s instructions. (Viii) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencieswill carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDAofficials or their representatives, The OEM"s authorised service representative or OEM certified agencies or approved will carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (IX) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.2000.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (X). Each maintenance job shall be covered period of 09 Months (XI)Cost ofmajor/ minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & boltsPCB replacement , Pump replacement , replacement of Compressor , Fan Motor, PCB , Gas charging , Magnetic Switch , transformer , Electronic Expansion Valve, Sensor etc and like shall be deemed to be inclusive of the quoted rate.
111Comprehensive maintenance and repair including renewal / replacement of minor defective parts of Ice Lined refrigerator indoor and out door units installed including carrying out the Physical and health check up and service, gas pressure, electrical connections, etc. During the check up ofIce lined cold refrigerator, including minor parts required shall be deemed inclusive ofrate and if any major parts found unserviceavle to be replaced and then item paid separately under respective item. NOTE : OEM Rep will visit the 1st week of every month.ii) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing .(III) Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of AC plantincluding maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentmanufacturer"s instructions. (IV) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencieswill carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDAofficials or their representatives, The OEM"s authorised service representative or OEM certified agencies or approved will carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (V) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.2000.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (X). Each maintenance job shall be covered period of 09 Months (XI)Cost ofmajor/ minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & boltsetc and like shall be deemed to be inclusive of the quoted rate.
112Comprehensive maintenance and repair including renewal / replacement of minor defective parts of Dehumidifier units installed at including carrying out the Physical and health check up and service, gas pressure, electrical connections, etc. During the check up of Dehumidifierif any parts found unserviceavle to be replaced and then item paid separately under respective item. NOTE : OEM Rep will visit the 1st week of every month.NOTE : OEM Rep will visit the 1st week of every month.ii) After servicing, OEM has to submit the serviceability certificate duly sign by OEM, User and shall have to submit to Dept for Payment purpose and warranty for the replaced items for one year from the date of servicing .(III) Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of AC plantincluding maintenance of all mechanical, electrical and electronic parts /sub-assemblies. Thepreventive maintenance report will be as per the Original Equipmentmanufacturer"s instructions. (IV) Breakdown Maintenance : The Authorised ServiceEngineer of OEM or OEM Certified Agencieswill carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) KALAIKUNDAofficials or their representatives, The OEM"s authorised service representative or OEM certified agencies or approved will carry out the required repairs of theunits and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during maintenence period including defect liablity period . (V) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.2000.00 (Rupees Two Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (X). Each maintenance job shall be covered period of 09 Months (XI)Cost ofmajor/ minor items like teflon tape,insulation tape, metal washers, fibre/rubber washers, screws, small nuts & boltsetc and like shall be deemed to be inclusive of the quoted rate.
113Supply only Distrilled water for ICR complete all as specified and directed.
114Supply only RH controller as per Original Equipment Manufacturer"s (OEMs) reccommendations with and including all connected accessories through Authorised Original Equipment Manufacturer"s Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified.