Tender For Repair And Maintenance Of Summer Appliances And Connected Equipment At Dappar., dappar-Punjab

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances And Connected Equipment At Dappar.. Submission Date for this Tender is 06-02-2024. Air Conditioner Tenders in dappar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

41646750
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances And Connected Equipment At Dappar.
Open Tender
Indian
Punjab
dappar
06-02-2024

Tender Details

Tender For Repair And Maintenance Of Summer Appliances And Connected Equipment At Dappar.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-02-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair and maintenance of summer aplliances and connected and equipment at Dappar under AGE (I) Dappar
Sl. No. Item Description
1Servicing of solar water heating plant capacity of 500 to 1500 Ltr capacity at site complete, opening of all tubes descaling and replacing broken/ u/s panel making good surface and fixing in original position, opening of water heating tank cleaning, replacing heating element of 3 x 3KWas per existing model/size and making leak proof and testing to the entire satisfaction of Engr-in-Charge all as specified and directed by Engr-in-Charge.
2Supply and fix in replacement heating element with capacity 3 KW suitable for500 to 1500 Ltr capacity solar water heating plant all as specified and directed by Engineer-in-charge.
3M&L for MS pipe 40mm dia connecting, welding , smoothing and making leak proof and including insulation with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 gauge aluminium super quality sheet including clamping/ binding material as per site requirement/directed and testing entire work to be carried out providing material strictly of existing specifications and to the entire satisfaction of Engineer-in Charge, including dismantling of old MS pipe complete all as specified and directed by Engr-in-Charge.
4Taking down carefully ceiling/ exhaust/ wall mounted fans (of any size/make) from site, transporting the same to the store for repair complete all as directed by Engineer-in-charge. Note :-Repairs will be measured and paid separately under respective items.
5Hanging / fixing only ceiling fan and connecting including provision of cable from ceiling rose or connector to fan all as specified and directed by Engr-in-Charge.
6Fixing only exhaust fan/ wall mounted fan and connecting including provision of cable from ceiling rose or connector to fan all as specified and directed by Engr-in-Charge..
7Strip opening toceiling fanofany make / type / size for repair, re-assembling after replacement of defective parts and testing after repair Completeall as specified and as directed by Engineer-in-chargeNote :-Parts will be measured and paid for separately as supply only under respective items repair shall and light shall be done at the MES store yard.
8M&L for rewinding toceiling fan motor of1200mm sweep windedwith winding machinewith super enameled copper winding wire of existing size gauge & design includinginsulated sleeves & paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cableof copper conductor of size 23/.0076upto connector block ( winding wireexc 300 gm and n-exc 350gm ) Complete the above work shall be done at the MES store yard all as specified and as directed by Engineer-in-charge.
9M&L for rewinding to ceiling fan motor of 1400/ 1500mm sweep windedwith winding machine with super enamelled copper winding wire of existing size gauge & design includinginsulated sleeves& paper, varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cableof copper conductor of size 23/.0076upto connector block ( winding wireexc 350 gm and n-exc 400gm ) Completeall as specified and as directed by Engineer-in-charge. The repair shall be carried out at the MES store yard.
10Supply only the under mentioned Ball bearing suitable for 1200/ 1400/ 1500 mm sweep ceiling fans and sweepExhaust / Padestal/ Wall mounting fan :-(a) Ball Bearing No 6201 Make : SKF/NBC/TATA.
11(b) Ball Bearing No 6202 Make : SKF/NBC/TATA
12(c) Ball Bearing No 6203 Make : SKF/NBC/TATA
13(d) Ball Bearing No 6204 Make :SKF/NBC/TATA
14Supply only gun metal bushsuitable for 1200/1400/1500 mm sweep ceiling fans, all as specified and as directed by Engineer-in-charge.
15Supply onlyMild steel shaft of existing specifications suitable for 1200/1400/1500 mm sweep ceiling fans all as specified and as directed by Engineer-in-charge.
16Strip openingto exhaust fan/padestal fan / wall mounted fan of any size / make / sweep to carry outrepairs from store yard of AGE E/M to contractor’s workshop and vice vrsa and re-assembling and testing after the repairs in store yard of AGE E/M Completeall as specified and as directed by Engineer-in-charge. The above shall be done at the MES store yard
17M&L for rewinding to Exhaust / Padestal/ Wall mounting fanmotor of225mm to 300mm sweep winded with winding machinewith super enamelled copper winding wire of existing size gauge & design includinginsulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cableof copper conductor of size 23/.0076up to connector block(winding with exc 400 gm and n-exc 450 gm) Completeall as specified and directed by Engineer-in-charge. the above shall be done at the MES store yard.
18Description all as per Srl item No 17 here-in –before but Exhaust Fan350/450 mm sweep Notes:- For Srl item No 17 & 18 here-in before -(i) The cost of cutting & taking out to existing old winding wire shall be deemed tobe included in the unit rate of these items. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings, Bush & shafts etc shall be measured &paid as Supply onlyseparately under respective items.Fixing charges of these spare parts shall deemed to be included in the unit rate quoted for these items.
19Supply only gun metal bush of existing specifications suitable for 225/300/350/450 mm sweepExhaust / Padestal/ Wall mounting fan all as specified and as directed by Engineer-in-charge.
20Supply onlyMild steel shaft of existing specifications suitable for 225/ 300/ 350/ 450 mm sweepExhaust / Padestal/ Wall mounting fan all as specified and as directed by Engineer-in-charge..
21M&L for lath work to any type of fan for taking out bush from the lower body part of ceiling fan and replacing it with suitable size of ball bearingas per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Completeall as specified and as directed by Engineer-in-charge.Note : - Supply & fixing to Bearing shall be measured and paidseparately under respective item of this Schedule.
22M& L in replacement of Exhaust fan louvers metal body of suitable for 250to 350 mm sweep exhaust fanfix at a hight of 10 mtr Completeall as specified and as directed by Engineer-in-charge.
23M& L in replacement of Exhaust fan louvers metal body of suitable for 450 mm sweep exhaust fanfix at a hight of 10 mtr Completeall as specified and as directed by Engineer-in-charge.
24Replacement of unserviceable capacitor4 MFD suitable for 415 volt AC Completeall as specified and as directed by Engineer-in-charge.Make :-DENFOS/ INDOFOS
25Replacement of unserviceable capacitor 3.15 mfd suitable for 415 volt AC Completeall as specified anddirected by Engineer-in-charge. Make :-DENFOS/ INDOFOS
26M&L for painting to ceiling fan complete,with synthetic enamel paint by spray painting including filling cavities with filler, one coat after cleaning all dustpainting with MES NO /SM NO on fans etc , complete all as specified and directed by Engineer-in-charge.
27Replacement of fan blades (set of three blades) suitable for 1200/1400/1500mm sweep fanCompleteall as specified and as directed by Engineer-in-charge.
28Supply and fix in replacement M.S rodof length of 450 mm and dia 15 mm including clamp , nut & split pinsuitable for 1200/1400/1500mm sweep fan Completeall as specified and directed byEngineer-in-charge.
29Supply and fix in replacement rubber real suitable for 1200/1400/1500mm sweep fan completeall as specified and directed by Engineer-in-charge.
30Supply and fix in replacement PVC canopysuitable for 1200/1400/1500mm sweep fan completeall as specified and directed by Engineer-in-Charge.
31Supply and fix in replacement of unserviceable electronic Modular step regulator (as per site requirement) suitable for 1200/1400/1500mm sweep fan as existing completeall as specified and directed by Engineer-in-Charge.
32Supply and fix in replacement of unserviceable electronic step type switch suitable for 1200/1400/1500mm sweep fanas existing (modular/piano) completeall as specified and directed by Engineer-in-Charge.
33Supply and fix in replacement fan blade set suitable for Exhaust fan 300 to 450 mmsweep completeall as specified and directed by Engineer-in-charge.
34Taking down desert cooler of any make & size at different site / location and carrying out necessary repairs as to stop leakage and replacement of rusted nuts bolts washers etc and scrapping of old paint and removing scales from internal & external surfaces top and bottom complete and providing two coats of synthetic enamel (hammer tone) paint by spray machine over one coat of red oxide primer including writing of MES/SM NO in 3 cm height and re fixing in existing position after greasing ,oiling and servicing of fan motors pumps and making good and serviceable condition all as specified and directed byEngineer-in -Charge.
35M&L for rewinding toDesert cooler motor of450/500 mm sweep winded with winding machinewith super enamelled copper winding wire of existing size gauge & design includinginsulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cableof copper conductor of size 23/.0076up to connector block(winding with exc 400 gm and n-exc 450 gm) Completeall as specified and directed by Engineer-in-charge. the above shall be done at the MES store yard.
36Supply and fix in replacement Desert cooler fan motor of copper winding of capacity 200W, 1300 RPM 50HZ 240 Volts, winding material- Copper, single phase, 500 mm sweepAC Make: Orient,Khetan
37Supply and fix in replacement pump 18 watt 220 volts AC electric driven suitable for 4 meter head all as specified and directed byEngineer-in -Charge. .Make : Usha/Khetan
38Supply and fix in replacement dusty/worn out wool/grass pad (set of 3 nos) all as specified and directed byEngineer-in -Charge.
39Supply and fix in replacement Honey bee pad (set of 3 nos) synthetic all as specified and directed byEngineer-in -Charge.
40Supply and fix in replacement polyethylene pipe of 15mm bore high density of existing specifications all as specified and directed byEngineer-in -Charge.
41Supply and fix in replacement selector switch (3 speed) of existing specifications & make
42Supply and fix in replacement PVC ELBOW (Set of three) and Tee (One) Right angle of existing specifications all as specified and directed byEngineer-in -Charge.
43Supply and fix in replacement PVC top plug 3 pin 5Amp 230 Volts all as specified and directed byEngineer-in -Charge. Make : Anchor/ SSK.
44Supply and fix in replacement flexible copper conductor size 23/0.0076 3 core pvc insulated sheet
45Supply and fix in replacement of worn out capacitor 4MFD , 230volts, 50Hz all as specified and directed byEngineer-in -Charge.
46Taking out to unserviceable MSpart body of any capacity including existing fan, motor, blades, water lifting pump and electric wiring, fitting switches etc complete all as specified and directed by Engineer-in –Charge
47M& L GI steel body of desert cooler of capacity 3000cum duly painted with two coats synthetic enamelled paint on external surface and black painting with MES NO /SM NO on internal surface over one coat of red oxide primer with spray gun machine.The body of desert cooler will be fabricated as under mentioned complete all as specified and directed by Engineer-in –Charge (a) Top and bottom made out of 1.25 mm thick GI sheet. (b) side panels(set of 3) made out 1.00 mm thick GI sheet with wood wool pads and wire mesh of GI wire 1.4 mm dia 2.5 mm mesh for holding pads. (c) Front grill of suitable size and approved quality GI sheet. (d) Re fixing serviceable existing fan water lifting pump, fan, motor, blades, wiring, fittings etc . NOTE: Unserviceable parts shall be replaced with new serviceable parts and shall be paid as supply only under respective items of this schedule.
48Supply and fix in replacement desert cooler side panels(set of 3) as per existing approx. size 60x70 cm made out of 22 SW9 GI sheet with handle all as specified and directed by Engr - in Charge.
49M&L in replacement front show grill approx. size 55x60 cm for any make type of desert coolers having provision for rotary selector switch and toggle switch complete all as specified and directed by Engineer-in -Charge.
50Servicing of Window/ Slipt AC capacity of 1.5 to 2 ton capacity at site complete, with washing clenaing of indoor and out door complete cleaning, repair of minor part as per existing model/size and testing to the entire satisfaction of Engr-in-Charge all as specified and directed by Engr-in-Charge.
51Disconnecting to unserviceable sealed compressor of 1.5/2 Ton capacity window type AC and M& L replaced with new company sealed compressor of existing capacity& model including soldering of liquid /gas pipe ,cleaning the system & testing the leakingwith gas charging etccomplete all as specified and directed by Engineer-in-charge.Make : LG / Hitachi/ Voltas
52Description all as per above item No 46here-in-before but 1.5/2 Ton capacity split type AC. Make : LG / Hitachi/ Voltas.
53M& L Recharging of gas R-22 in air conditioner unit window type 1.5/2 ton complete including testing of leakage and testing & servicing the unit for satisfactory performance Complete all as specified and directed by Engineer-in-Charge.
54Supply and fix inreplacement thermostat switch suitable for window type AC 1.5/2 Ton capacity.Complete all as specified and as directed by Engineer-in-Charge. Make :Renutrol/ Indfos
55Supply and fix in replacement starting capacitor 100-200 mfd suitable for window/split type AC of anycapacity complete all as specified and as directed by Engineer-in-Charge. Make : Usha / SIEMEN
56Supply and fix replacement runningcapacitor 36 MFDsuitable forwindow/ split type ACof anycapacity complete all as specified and directed by Engineer-in-Charge.Make : Usha / SIEMEN
57Supply and fix in replacement thermo-stat switch suitable for split type AC 1.5/2Toncapacitycomplete all as specified and as directed by Engineer-in-Charge.Make : Rentrol/ Indfoss.
58Supply and fix in replacement over load protector suitable for split type AC 1.5/2Ton capacity complete all as specified and directed by Engineer-in-Charge Make : Renutrol/ Indfoss.
59Disconnecting and taking out worn out/unserviceable sealed compressor of water cooler of capacity 40/80/120 ltrs and M& L replacing with new sealed compressor of existing capacity and size including soldering of suction and discharge line gas pipe and flushing the complete system and making leak proof all as specified and directed by Engineer-in-charge. Make : LG/ HITACHI/ VOLTAS.
60Cleaning the system with CRC and charging the refrigerant gas R-22/M22including replacement of strainer filter suitable for water cooler of 40/80/120litrescapacitycomplete all as specified and directed by Engineer-in-charge.
61Supply and fix in replacement Startingrelay assemblysuitable forwater cooler of 40/80/120 ltr capacityComplete all as specified and directed by Engineer-in-Charge
62Material & Labour internal wiring forwater coolers 80/40 ltr capacity with PVC insulatedunsheathed flexible copper conductor cablesingle core size 40/0.0076fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and directed by Engineer-in-charge.Make :Kalinga/Finolex/Plaza.
63Supply and fix in replacementStarting capacitor 40-60 mfd assembly all as specified and directed by Engineer-in-Charge
64Supply and fix in replacement Running capacitor 10 mfd assembly all as specified and directed by Engineer-in-Charge.
65Supply and fix in replacement over load protectorcomplete all as specified and directed by Engineer-in-Charge Make :-- Renutral/ Indfos
66Supply and fix in replacement drain hose pipe 40mm diasuitable forwater cooler of 40/80 liter capacitycomplete all as specified and directed by Engineer-in-Charge Make : Renutral/ Indfos
67Supply and fix in replacement clamp for fan motor of 1/16 to 1/32 hp hose pipecomplete all as specified anddirected by Engineer-in-Charge Make : Renutral/ Indfos
68Supply and fix in replacement fan blade plastic for fan motor 1/32 hp complete all as specified and directed by Engineer-in-Charge.
69Supply and fix inreplacement clamp for hose pipe complete all as specified and directed by Engineer-in-Charge.
70Supply and fix in replacement fan motor with new one suitable for water cooler of capacity 40/80/120ltrs complete all as specified and directed by Engineer-in-Charge. Make : Cool home/ AUE
71Supply and fix in replacement self closing tap push type 15 mm bore of cast copper alloy chromium plated fixed to water cooler as in repair complete all as specified and directed by Engineer-in-Charge.
72Dismantling of unsv float valve assy and supply and fixing PVC float valves complete assy 15 mm size complete all as specified and directed by Engr-in-Charge.
73Supply and fix in PVC connectionpipe with male female sockets 45 cm long for water cooler 40/80/120 ltr capacity complete all as specified and directed by Engineer-in-charge.
74Supply and fix in replacement thermo-stat switch with new one complete all as specified and directed by Engineer-in-Charge. Make :-- Renutral/ Indfos/Dasspass
75Disconnecting to unserviceable sealed compressor for 330 ltr capacity ofrefrigerator and M & L replaced with new company sealed compressor of existing capacity& model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge Make : Godrej/ LG/ VOLTAS.
76Disconnecting to Unserviceable Freezer door of capacity 300 ltr refrigerator andM & L Replace the Freezer door plastic with tension spring of existing modelsuitable 300 liter cap refrigerator.
77Disconnecting to unserviceable freezer chamber of refregerator of capacity 300/350 ltr and M& L replaced with New freezer chamber of refrigerator of capacity 300/350 ltr of existing capacity& model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge.
78M & L Cleaning the system with CRC and charging the refrigerant gas R-134 including replacing strainer and rectification of leakage in the system from refrigerator 330 litrescapacitycomplete all as specified anddirected by Engineer-in-charge.
79Supply and fix in replacementstartingrelay assemblysuitable forrefrigerator 330 litrescapacitycomplete all as specified and directed by Engineer-in-Charge.
80Supply and fix in replacement Starting capacitor 40-60 mfd assembly suitable forrefrigerator 330litres capacityComplete all as specified and directed by Engineer-in-Charge
81Supply and fix inreplacement over load protector suitable forrefrigerator 330 litrescapacityComplete all as specified and directed by Engineer-in-Charge Make : Renutral/ Indfoss.
82Supply and fix in replacement thermo-stat switch suitable for refrigerator anycapacityComplete all as specified and as directed by Engineer-in-Charge. Make :-- Renutral/ Indfoss
83Supply and fix in replacement heating element with capacity 2KW suitable for geyser 50ltrs all as specified and directed by Engineer-in-charge.
84Supply and fix in replacement heating element with capacity 1KW suitable for geyser 25ltrs all as directed by Engineer-in-charge.
85Supply and fix in replacement Thermostat suitable for geysers 25 to 50 Ltrs complete all as specified and directed by Engineer-in-charge.
86Supply and fix in replacement Pressure release valve of existing specification & make for geysers of cap 25 to 50 Ltrs complete all as specified and directed by Engineer-in-Charge.
87Preparation surface for painting and painting of geysers cap 25/50Ltrs with 2 coats of synthetic enamel painting with MES NO /SM NO in situ complete all as specified and directed by Engineer-in-Charge
88Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 25 ltrs geyser complete all as specified and directed by Engineer-in-Charge.
89Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 50 ltrs geyser complete all as specified and directed by Engineer-in-Charge.
90Supply and fix in replacement Gun Metal non return valve size of 15 mm of existing make for geysers of cap 25 / 50 Ltrcomplete all as specified and directed by Engineer-in-Charge.
91Supply and fix in PVC connectionpipe with male female sockets 45 cm long for geyser 25/50 ltrs capacity complete all as specified and directed by Engineer-in-charge.
92Supply and fix in replacement Sheet metal enclosure with socket plug top and MCB SPN cap 32 Amps with a 2 pin,earth plug and socket complete all as specified and directed by Engineer-in-Charge. Make : Indo Asian/ Havells/ Legrand
93Dismaintling of voltage stablizer and various components of automatic voltage corrector of any rating but cap not exceeding 5 KVA, single phase , 50 Hz including locating the faults complete all as specified and directed by Engineer-in-Charge.
94Dismaintling of burnt U/S main transformer copper wound and stamping and material and labour for re-assembling the stemping and re-winding of main transformer, single phase, 50 Hz with super enamelledcopper winding wire of existing size, design & weightSWG turns / tapping and varnishing complete of voltage stablizer cap up to 4 KVA, complete all as specified and directed by Engineer-in-Charge.
95Description all as per Ser item No 94 here-in-before but 5 KVA all as specified and directed.
96Description all as per Ser item No94 here-in-before but 3 KVA all as specified and directed Engineer-in-Charge.
97S&F (in replacement) voltage regulator PCB for voltage stabliser for power rating 5KVA complete all as specified and directed by Engr -in-Charge.
98Description all as per Ser item No 91 here-in-before but for power rating 4 KVA all as specified and directed by Engr -in-Charge.
99Description all as per Ser item No 91 here-in-before but for power rating 3 KVA all as specified and directed by Engr -in-Charge.
100Material & Labour PVC cable flexible 3 core size 70 / 0.0076 all as specified and directed by Engr -in-Charge.
101Material & Labour 3 pin plug top 15 Amp, 250 Volt, complete all as specified and directed by Engr -in-Charge. Make : Anchor / SSK / Fine.
102Disconnecting to unserviceable sealed compressor ofdeep freezer of capacity 300 liter and M& L replaced with New sealed compressor of existing capacity& model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge Make :-- Sri-Ram/ Tikamshah/ Kirloskar
103M& L Cleaning the system with CRC and charging the refrigerant gas R-134 including replacing strainer and rectification of leakage in the system from deep freezer of 300 litrescapacitycomplete all as specified and as directed by Engineer-in-charge.
104M& L for Cleaning tointernal surfaces of deep freezer of 300 litres capacity suitable repairs tobody to stop leakage etc, replacing unserviceable nuts bolts & washers etc including preparation of external surfaces ofbodyandpainted withanticorrosive synthetic enamel paint withhelp of spray gunmachine over a coat of red oxide and writing SM / MES No in 3cm height Complete all as specified and as directed by Engineer-in-Charge.
105S&F in replacement startingrelay assembly suitable for deep freezer of 300 litrescapacitycomplete all as specified and as directed by Engineer-in-Charge
106Material & Labour internal wiring for deep freezer of 300 litres capacity with PVC insulatedunsheathed flexible copper conductor cablesingle core size 40/0.0076fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and as directed by Engineer-in-charge.Make :-- KALINGA/ FINOLEX/PALAZA
107Supply and fix in replacementStarting capacitor 40-100 mfd assembly suitable fordeep freezer of 300 litrescapacityComplete all as specified and as directed by Engineer-in-Charge
108Supply and fix in replacement Running capacitor 10-20 mfdsuitable fordeep freezer of 300 litrescapacityComplete all as specified and as directed by Engineer-in-charge
109Supply and fix in replacement over load protector suitable fordeep freezer of 300 litrescapacityComplete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfoss
110Supply and fix in replacement Drain hose pipe 40mm dia suitable fordeep freezer of 300 litrescapacityComplete all as specified and as directed by Engineer-in-Charge Make : Renutral/ Indfoss
111Supply and fix in replacement Clamp for fan moter for 1/16 to 1/32 hp hose pipe suitable for Clamp for hose pipe deep freezer of 300 litrescapacityComplete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfos
112Supply and fix in replacementfan blade plastic for fan moter 1/32 hp suitable forfan blade plastic for fan moter 1/32 hpdeep freezer of 300 litres capacityComplete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfos
113Supply and fix in replacementclamp for hose pipe suitable for clamp for hose pipe deep freezer of 300 litres capacity complete all as specified and as directed by Engineer-in-Charge Make :-- Renutral/ Indfoss
114Supply and fix in replacement fan motor suitable fordeep freezer of 300 litres capacityComplete all as specified and as directed by Engineer-in-Charge.Make :-- Cool home/ AUE
115Supply and fix in replacement condensor coilsuitable fordeep freezer of 300 litres capacitycomplete all as specified and as directed by Engineer-in-charge.
116Supply and fix in replacement thermostat switch with new thermostat switch suitable for deep freezer anycapacitycomplete all as specified and as directed by Engineer-in-charge. Make :-- Renutral/ Indfoss
117Supply and fixing in replacementMCBSP 6 -32 Amps,10 KA, "C" series 240 V ISI marked complete all as specified and directed by Engineer-in-charge. MAKE : Legrand/ABB/Schenider
118Supply and fixing in replacement MCB SPN 06-32Amps,10 KA "C" series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. Make: Legrand/ABB/Schenider
119Supply and fixing in replacement MCB TPN 63Amps,10 KA "C" series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. Make: Legrand/ABB/Schenider
120Taking down existing old unserviceable puf insulation from MS pipe and Material and labour for insulation over a existing MS pipe of size 80mm dia with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 guage alluminium super quility sheet including clamping/ binding material, testing as per site requirment and directed by Engr-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail